Professional Documents
Culture Documents
2.SV Maintenance Technology Practice
2.SV Maintenance Technology Practice
2.SV Maintenance Technology Practice
Inspur group
2019/8/29
2
Course Content
Motherboard Architecture
Recognition of CPU, memory, fan slots, and their installation and removal
Clear CMOS operation
Introduction to the front and rear panels of the machine
BIOS basic settings
Date and time
Boot sequence
CPU and memory parameters
Onboard SATA settings
Power-on self-start setting
BMC configuration
BIOS/BMC version check
Basic BMC Management function
BIOS/BMC/FRU update
Raid card configuration
客户服务中心 2019/8/29
Show and practice
3
PCIe* 3.0 x8
PCIe* 3.0 x8
PCIe* 3.0 x8
PCIe* 3.0 x8
PCIe* 3.0 x8
PCIe* 3.0 x8
PCIe* 3.0 x8
PCIe* 3.0 x8
PCIe* 2.0 x4
PCIe* 3.0 x8
Intel® AMT Technology
DMI2
(for SVR)
2019/8/29
10
(1)Lightly squeeze the dust cover (2)Align the triangular mark on the plastic clip to the triangular
and lift straight up to remove the dust mark on the CPU. Install the PUSH side first, then slightly lift the
cover. Check the CPU socket to see if two corners of LATCH side. Press down the clip with thumb to
there are any bent pins or damages. secure the CPU into the clip.
(4)Install the assembled heatsink module (3)Match the location of the “1” position on the heatsink
perpendicularly to the CPU socket, matching the “1” to the triangular mark on the CPU clip, then align the
on the heatsink module to the triangular marking positioning holes of the heatsink perpendicularly to the
on the CPU socket. Screw in the mounting screws CPU clip. Press to assemble the two parts. Caution:
in 1 to 4 sequence with one hand while slightly Remove the protective film on the heatsink if present.
holding the heatsink module down with the other
hand.
11
CPU bent pins
12
Memory Installation and removal
Step 1: Open the lock tabs on both ends of memory slot, remove the memory
vertically.
Step 2: Align the bottom key on the memory with the receptive point on the slot,
press both ends of the memory with even force, to insert the memory into the
slot completely, and the lock tabs will automatically secure the memory, locking
it into place.
13
Fan Installation
Please note:
The fans’ power lines can’t be
connected at will, and should be
connected according to the
corresponding relations in the
knowledge base of intranet.
14
Fan Installation
15
Clear the CMOS
When need to clear the CMOS
No significant power
Hardware is identified abnormal
客户服务中心 2019/8/29
16
Clear the CMOS
Steps to clear CMOS using the jumper method
1.Power off the system.
2.Open up the system so you can see the motherboard.
3.Locate the CMOS jumper by referring to the motherboard manual and how to clear the
CMOS. In general, the CMOS jumper is three pins located near the battery.
4.In general, CMOS jumper has positions 1–2 and 2–3. Move the jumper from the default
position 1–2 to position 2–3 to clear CMOS. Wait 1–5 minutes then move it back to the
default position.
5.Power on the system. In some systems, you might need to enter BIOS to reset to the
factory defaults.
客户服务中心 2019/8/29
17
Clear the CMOS
Steps to clear CMOS using the battery method
1.Turn off all peripheral devices connected to the server.
2.Disconnect the power cord from the AC power source.
3.Remove the server cover. Example of battery onboard:
4.Find the battery on the board. The battery may be in a
horizontal or vertical battery holder, or connected to an
onboard header with a wire.
Remove the battery:
If the battery is in a holder, note the orientation of
the + and – on the battery. Gently pry the battery free from
its connector.
If the battery is connected to an onboard header with a wire,
disconnect the wire from the onboard header.
Wait 1–5 minutes, then reconnect the battery.
5.Put the server cover back on.
6.Plug the server and all devices back in.
客户服务中心 2019/8/29
18
M4/M5 Front Panel Introduction
Front panel of NF5280M4
19
attention:
NIC1 port is used as multiplex
port of BMC commonly
21
客户服务中心 2019/8/29
22
BIOS Introduction
BIOS(Basic Input Output System)--The BIOS is the most basic program code loaded
on the computer motherboard. It holds the most important basic input and output
programs of the computer, the self-test program after booting, and the system self-
starting program. Its main function is to provide the lowest level of the computer with
the most direct hardware settings and control, look for boot devices, boot systems or
other pre-boot environments, etc. It can read and write specific information of system
settings from CMOS.
CMOS is often used to store a computer's basic boot information (such as date, time,
boot settings, etc.).Sometimes people will mix CMOS and BIOS. In fact, CMOS is a
readable and writable parallel or serial FLASH chip on the motherboard. It is used to
save the BIOS hardware configuration and user settings for certain parameters.
The BIOS of Inspur Purley platform server is developed based on AMI's Codebase. It
supports Legacy and UEFI environment operations. It has rich in-band and out-of-band
configuration functions and rich and scalable features to meet the needs of different
customers.
23
客户服务中心 2019/8/29
24
BIOS Setup Interface control key description table
25
Main Interface description
26
Advanced Interface description
27
Chipset Interface description
28
Processor Interface description
29
Server Mgmt Interface description
Interface
Function Description Defaults
parameter
BMC Self Test
BMC Self-test status ----
Status
BMC Firmware Current motherboard BMC
----
Version firmware version number
FRB-2 Clock switch settings, option
FRB-2 Timer parameters are: Enabled
Enabled Disabled
FRB-2 Clock timeout setting, option
FRB-2 Timer
parameters are: 6 minutes
timeout
3-6 minutes
FRB-2 After the clock expires, the
FRB-2 Timer policy settings are as follows:
Power Cycle
policy Do Nothing/Reset/Power Down
/Power Cycle
OS Watchdog clock switch settings,
OS Watchdog
option parameters are: Disabled
Timer
Enabled Disabled
OS Watchdog clock timeout setting,
OS Wtd Timer BMC network configuration BMC Network configuration submenu
option parameters are: 10 minutes
timeout BMC User Settings BMC User settings submenu
5-20 minutes
OS The policy settings after the VLAN Configuration VLAN Configuration submenu
watchdog clock times out, the
OS Wtd Timer View FRU information View FRU information submenu
option parameters are: Reset
policy
Do Nothing/Reset/Power Down
/Power Cycle
30
Boot Interface description
31
Save & Exit Interface description
32
Basic BIOS settings
客户服务中心 2019/8/29
33
Basic BIOS settings
Hyper-threading: hyper-
threading on-off switch
客户服务中心 2019/8/29
35
Basic BIOS settings
① Chipset->Advanced Power
Management Configuration-
>Power Technology:[Custom]
② Chipset->Advance Power
Management Configuration-
>CPU C State Control-
>Monitor/Mwait
Support:[Disabled]
客户服务中心 2019/8/29
36
BMC Network parameter viewing and settings
客户服务中心 2019/8/29
38
Add BMC username and password
客户服务中心 2019/8/29
39
Add BMC username and password
客户服务中心 2019/8/29
40
Add BMC username and password
客户服务中心 2019/8/29
41
Add BMC username and password
客户服务中心 2019/8/29
42
Add BMC username and password
客户服务中心 2019/8/29
43
Add BMC username and password
客户服务中心 2019/8/29
44
Add BMC username and password
客户服务中心 2019/8/29
45
You need get into this interface to confirm whether the FRU is
refreshed right or not only after finish refreshing the FRU fw.
客户服务中心 2019/8/29
47
View the sensor information
客户服务中心 2019/8/29
48
UEFI/Legacy Mode switching
客户服务中心 2019/8/29
52
Introduction to BMC
BMC is a control unit for server management and is compatible with the industry standard
IPMI 2.0 specification. 。
functional module:
IPMI module, command line module, remote control module, web module, SNMP module
53
BMC WEB Management function
log in:
In your browser and enter "ipaddress". (Where ipaddress is the IP address of the
management network port)
The default user name: admin and default password: admin
login
interface
WEB
interface
54
BMC WEB Management function
From the part of information, mainly view the system information, Bios
setup options, FRU information.
55
BMC WEB Management function
From the part of storage, mainly view the storage controller information,
physical drives, logical drives.
56
BMC WEB Management function
From the part, control the power supply, server power and change the fan speed.
58
BMC WEB Management function
BMC Setup Module: Contains "BMC Network", "Service Settings", "NTP Settings",
"SMTP Settings", "Alarm management" 10 pages.
59
BMC WEB Management function
Log module: "System Event Log", "BMC System Log", "black box log", "Event Log
Settings", "BMC system audit log settings" on page five
60
BMC WEB Management function
This part lead us to update BIOS and BMC from BMC web
61
BIOS/BMC/FRU updating
客户服务中心 2019/8/29
62
BIOS/BMC/FRU updating
You can refer to the website to update BIOS/BMC/FRU
FW refreshing(SOP):
Knowledge base: http://218.57.146.166:8443/display/H
User: overseas password: overseas
Tool : U disk inserted with DOS system
Steps :
1. Check the customized instruction number
2. Download the BIOS/BMC upgrade files from the knowledge base
3. Put the files into the U disk (pay attention to modify the file name less than
eight characters) )
4. Start the U disk into the DOS environment
5. Enter the U disk directory under C:
6. Execution of upgrade instructions
客户服务中心 2019/8/29
63
BIOS/BMC/FRU updating
1. Check the customized instruction number
客户服务中心 2019/8/29
64
BIOS/BMC/FRU updating
2. Download the BIOS/BMC upgrade files from the knowledge base
客户服务中心 2019/8/29
65
BIOS/BMC/FRU updating
2. Download the BIOS/BMC upgrade files from the knowledge
base
客户服务中心 2019/8/29
66
BIOS/BMC/FRU updating
3. Put the Decompressed files into the U disk (pay attention to
modify the file name less than eight characters) )
客户服务中心 2019/8/29
67
Inspur group
89
BMC refresh with BMC webpage
System Maintenance -> BMC FW Update
Inspur group
90
BMC refresh with BMC webpage
Press “Enter Firmware Update Mode”
91
BMC refresh with BMC webpage
Press “OK”
92
BMC refresh with BMC webpage
Click the button shown with the red line
93
BMC refresh with BMC webpage
Select the file to refresh
94
BMC refresh with BMC webpage
Select the file to refresh,then press “Upload”
95
BMC refresh with BMC webpage
Press “Upload”
96
BMC refresh with BMC webpage
Press “Proceed to update”
97
BMC refresh with BMC webpage
98
BMC refresh with BMC webpage
BMC firmware update complete.
99
客户服务中心 2019/8/29
100
RAID configuration
客户服务中心 2019/8/29
117
客户服务中心 2019/8/29
118
客户服务中心 2019/8/29
119
客户服务中心 2019/8/29
120
客户服务中心 2019/8/29
121
客户服务中心 2019/8/29
122
PMC (Microsemi) Series Raid Card-BIOS
Enter configuration
123
PMC (Microsemi) Series Raid Card-BIOS
Configuration main interface
124
PMC (Microsemi) Series Raid Card-BIOS
Array configuration menu
125
PMC (Microsemi) Series Raid Card-BIOS
Create an array
126
PMC (Microsemi) series Raid card-Configuration interface
Enter the Raid card configuration interface
127
PMC (Microsemi) series Raid card-Configuration interface
Raid card main interface
128
PMC (Microsemi) series Raid card-Configuration interface
Array configuration interface
129
PMC (Microsemi) series Raid card-Configuration interface
Create an array
130
PMC (Microsemi) series Raid card-Configuration interface
Create an array
131
PMC (Microsemi) series Raid card-Configuration interface
Create an array
132
Thank you!