Programmable Counter/Timer

Flow chart for function setting mode (A)


Photo
electric
sensor
Run mode
(B)
Fiber
optic
3sec. 3sec. 5sec. 3sec. sensor

(C)
Parameter group1 ,
Parameter group2 Door/Area
sensor
(GRp1) (GRp2)
※3
Counter Timer (D)
(COUN) Counter/Timer (T1ME) Proximity
sensor
(C-T) Communication
※3 ※3 (E)
Input mode Time range Com. address Pressure
sensor
(IN) (HOUR/MIN/SEC) (ADDR)
※3 ※2 ※3 (F)
Rotary
Output mode Up/Down mode Com. speed encoder

(ㅐㅕㅆOUtM) (U-D) (BPS)


Indication mode ※1 ※3
(G)
Connector/
(DSpM) Socket
※1 Indication mode Com. parity
※3 (DSpM) (PRTY) (H)
Max. counting speed Temp.
controller
(CPS)
Memorize Com. stop bit
※2 ※3 counting value (STP) (I)
SSR/
(DATA) Power
OUT2 output time ※3 controller
(OUT2)
Function setting mode

Output mode Response


※3 (OUtM) waiting time (J)
Counter
OUT1 output time (RSwT)
※3
(OUT1)
OUT2 output time (K)
※3 (OUT2) Com. writing Timer

Decimal point ※3
(COmW)
(DP) (L)
OUT1 output time Panel
meter
(OUT1) ※1: Indicator
Min. reset time ※2: Output type (M)
(RST) ※3: If changing the setting Tacho/
Input logic Speed/ Pulse
(SIG) value of function, OUT1, meter

Input logic OUT2 will turn OFF and


(SIG) return to Run mode, then (N)
Display
Input signal time present value resets. unit
※3 (InT)
Prescale decimal (O)
point Sensor
controller
(ScDP) Lock key
(LOCK)
※3 (P)
Switching
mode power
Prescale value supply
(RST) ※Counter
※3 - Single preset model has no "OUT1 output setting time" setting function (Q)
Stepper
mode and OUtT is displayed in "OUT2 output time" setting function mode. motor&
Start Point value - In case of DN, DN-1, DN-2 input mode, there is no "Start Point value" setting Driver&Controller

(STRT) function mode. (R)


- In case of F or N output mode, there is no "OUT2 output time" setting function Graphic/
Logic
mode.(Fixed to HOLD) panel
Memorize counting value - In case of S, T or D output mode, there is no "OUT2 output time" setting
(DATA) function mode. (S)
Field
※Timer network
device
- In case of FLk1, FLk2 or INtG output mode and OND, OND1, OND2 output
Lock key mode of single preset model, OUtT is displayed in "OUT2 output time" function
(LOCK) setting mode and there is no "OUT1 output time" function setting mode. (T)
Software
- The output modes except for OND, ONd1, ONd2 and INt2 output mode there is no
"OUT1 output time" function setting mode.
(U)
※If changing setting value of parameter group1, display value and output will be initialize. Other

※Press key over 3sec./5sec. in RUN mode to enter into parameter 1 group/ parameter 2 group.
Press key over 3 sec. in function setting mode to return RUN mode.
※Input operation and output control can be set in function setting mode.
※If changing set value of ※3 marked parameters in function setting mode, OUT1 and OUT2 output will be turned OFF and
then the current value is reset.
※Parameter 2 group is not available to non-communication models.

J-17
CT Series

Parameter setting(Counter)
( key: To select setting mode, or key: To change setting value)
Setting mode How to set
Counter/Timer ※CONE: COUNTER
ㅊㅊC-T COUN TIME TIME: TIMER

Input mode UD-C UP UP-1 UP-2 DN DN-1 DN-2 UD-A UD-B


IN

● UP, UP-1, UP-2 or DN, DN-1, DN-2 input mode


F N C R K P Q A
Output mode
※In case that output mode is F, N there is no "OUT2 output time" setting mode. (Fixed to HOLD)
OUtM ※If output mode is set to D when max. counting
● UD-A, UD-B, UD-C input mode
F N C R K P Q A S T D speed is set to 5Kcps, 10Kcps, max. counting
speed is automatically set to 30cps. (Factory
Indication mode default setting)
DSpM ● In case of the indicator
HOLD TOTAL ※In case of the indicator, indicate mode selection (DSpM)is displayed.
※It is added that the function which can set the preset value when selecting
HOLD.(Refer to J-22 page 'Counter operation of the indicator'.)

※Counting speed is that of one by one(1:1) duty ratio of INA or INB input signal,
Max. counting speed
30 1K SY 10K 1 and it is applied in INA and INB at thesame time.
CPS ※In case of setting D in output mode, you can choose 1cps, 30cps, 1Kcps.

: To shift flashing digit position of OUT2 ※Set OUT2 one-shot output time.
OUT2 output time
output time value. ※Setting range: 0.01 to 99.99 sec.
OUT2
: To change OUT2 output time value. ※It does not appear if F, N output mode is selected.
: To shift flashing digit position of OUT1 ※Set OUT1 one-shot setting time
OUT1 output time ※Time range: 0.01 to 99.99 sec., Hold
output time value.
OUT1 ※HOLD is displayed by pressing key 4 times.
: To change OUT1 output time value.
● 6digit type
------ -----.- ----.-- ---.--- --.---- -.-----
※1
Decimal point
● 4digit type ※Setting the decimal point is applied same to counting
DP ---- ---.- --.-- -.--- value and setting value.

Min. reset time


1 20 unit: ms ※Set the min. external RESET signal width.
RST

Input logic NPN: No-Voltage input


※Check input logic value(PNP, NPN).
SIG PNP: Voltage input

● 6digit type
※1
Prescale
decimal point ● 4digit type ※Prescale decimal point position is not set below the decimal
ScDP point setting digits (DP).

※Setting range of prescale value


Prescale value : To shift the flashing digit. 6digit type: 0.00001 to 99999.9
SCL : To change the prescale value. 4digit type: 0.001 to 999.9
※Refer to the J-20 page ' Prescale function'.
※Setting range of Start Point value (Connected with decimal point setting)
Start Point Value : To shift the flashing digit. 6digit type: 0.00000 to 999999
STRT : To change the Start Point value. 4digit type: 0.000 to 9999
※Refer to the J-20 page ' Start Point function'.
Memory protection ※CLR: Initializes count value when power is off.
CLR REC
DATA ※REC : Memorizes count value at the moment of power off.

LOFF LOc1 ※LOFF:Cancellation of the lock mode.


Lock key LOc1: Locks key.
LOCK LOc2: Locks , , keys.
LOc3 LOc2 LOc3: Locks , , , keys.

※1. Explanation of decimal point and prescale decimal point setting


- Decimal point setting : Set decimal point of the display value on front indicator.
- Prescale decimal point setting : Set prescale decimal point of counting regardless of decimal point of display value
on front indicator.

J-18