Pump Performance Datasheet

Customer : Quote number :


Customer enquiry : Pump Size : DB 65/32
Project : Stages :1
Item number : Default Based on curve number : HD10217B0 Rev 0
Usage - Tertiary : Date last saved : 24 Apr 2020 4:19 PM
Quantity :1 Note - Only duty point is guaranteed as per testing standard.
Operating Conditions Liquid
Flow, rated : 207.0 USgpm Liquid Type/ Application : Water
Differential Head (requested) : 25.00 m Additional liquid description :
Differential Head (actual) : 25.00 m Solids diameter, max : 0.00 mm
Suction pressure, rated / max : 0.00 / 0.00 bar.g Solids/Bagasse/Stock consistency by : 0.00 %
NPSH available, rated : Ample volume
Frequency : 50 Hz Temperature, max : 20.00 deg C
Performance Fluid density rated : 998.3 kg/m3
Speed, rated : 1450 rpm Viscosity, rated : 1.00 cSt
Impeller diameter, rated (approx.) : 286 mm Vapor pressure, rated : 0.02 bar.a
Impeller diameter, maximum : 329 mm Material
Impeller diameter, minimum : 255 mm Material selected : 16 MOC-CI260(012)/
Efficiency : 59.34 % CI260(012)/SS410(253)
NPSH required / margin required : 0.84 / 0.50 m Pressure Data
nq (imp. eye flow) / S (imp. eye flow) : 14 / 157 Metric units Maximum working pressure : 2.67 bar.g
Minimum Continuous Safe Flow (MCSF) : 57.24 USgpm Maximum allowable working pressure : 16.00 bar.g
Head, maximum, rated diameter (approx.) : 27.29 m Maximum allowable suction pressure : 1.96 bar.g
Head rise to shutoff (approx.) : 9.17 % Hydrostatic test pressure : 18.34 bar.g
Flow, best eff. point : 240.6 USgpm Driver & Power Data (@Max density)
Flow ratio, rated / BEP : 86.03 % Driver sizing specification : Rated Power
Diameter ratio (rated / max) : 86.93 % Margin over specification : 20.00 %
Head ratio (rated dia / max dia) : 70.10 % Service factor : 1.00
Cq/Ch/Ce/Cn [HI2010] : 1.00 / 1.00 / 1.00 / 1.00 Power, hydraulic : 3.20 kW
Selection status : Acceptable Power, rated : 5.39 kW
Performance testing standard : ISO 9906 / ANSI-HI 14.6 Power, maximum, rated diameter : 6.45 kW
Gr 2B Minimum recommended driver rating : 7.50 kW / 10.06 hp

8
Power - kW

6 Power

30 100
286 mm Minimum Continuous Safe Flow (MCSF)
27 90

24 80

21 70
Efficiency - %

18 60
Head - m

15 Efficiency 50

12 40

9 30

6 20

3 10

0 0
NPSHr - m

2
NPSHr
1

0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360
Flow - USgpm

· · ,