Bk2q-9k546-Ag 20190701 112041 PDF

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Continental PST marine

Injector type
BK2Q-9K546-AG
Reference Number
Old Grading Data
New Grading Data 9DDKEG
Date and Time 01/07/2019 11:20:41

Calibration
Test comments ford ranger#1

Electrical
Parameter Min. Max. Value Units Status
Capacitance 0.75 2.1 1.19 μF

Flush

Purge
Parameter Min. Max. Value Units Status
Pressure 1584 1616 1599 bar
Response 0 0 384 µS
Delivery 0 0 60.06 mm3/st
Back leak flow 0 0 24.8 mL/min

TP1
Parameter Min. Max. Value Units Status
Pressure 1584 1616 1600 bar
Response 304 456 386 µS
Delivery 55.61 63.73 60.27 mm3/st
Back leak flow 0 80 25.8 mL/min

TP2
Parameter Min. Max. Value Units Status
Pressure 1386 1414 1400 bar
Response 292 438 373 µS
Delivery 37.17 42.72 39.54 mm3/st
Back leak flow 0 55 17.9 mL/min

TP3
Parameter Min. Max. Value Units Status
Pressure 1188 1212 1199 bar
Response 280 420 339 µS
Delivery 1.22 5.65 2.86 mm3/st
Back leak flow 0 45 9.1 mL/min

TP4
Parameter Min. Max. Value Units Status
Pressure 990 1010 999 bar
Response 264 396 328 µS
Delivery 7.49 13.06 10.29 mm3/st
Back leak flow 0 45 2.6 mL/min
TP5
Parameter Min. Max. Value Units Status
Pressure 740 760 751 bar
Response 258 386 323 µS
Delivery 5.33 10.13 6.84 mm3/st
Back leak flow 0 30 5.8 mL/min

TP6
Parameter Min. Max. Value Units Status
Pressure 290 310 300 bar
Response 0 0 0 µS
Delivery 2.51 6.66 5.16 mm3/st
Back leak flow 0 30 3.6 mL/min

Static leak
Parameter Min. Max. Value Units Status
Pressure 990 1010 999 bar
Response 0 0 0 µS
Delivery 0 0 0 mm3/st
Back leak flow 0 30 3 mL/min

NOP
Parameter Min. Max. Value Units Status
Injector pressure 57 157 0 bar
Delivery 0.2 2 0 mm3/st

Grading code

Sv = 4.00 : T v = Issue-11 : F p = A262A902 : F v = 1.25 : Rv = 1.05 : Lv = 2.06 :

You might also like