COMBlNATlON

AlR ELlMlNATOR-STRAlNER GENERAL SPECIFICATION


08 0 GS.No.GCC007-4-E
MODEL AS1011-1
15 2

GENERAL
This device is an air release valve combined with a strainer
in a sing1e housing and is intended to eliminate air
entrained in the liquid while preventing foreign solids from
getting into the meter, which could present a serious
problem.
By installing this device immediately upstream of the
meter, or as close to the inlet as possible, accurate and
precise flow measurements can be made.

FEATURES
1. Simple design and easy to service.
2. Small pressure loss.
3. Sturdy construction and long service life.

GENERAL SPECIFICATIONS
Item Description GUIDE TO SELECTION
Model AS0811-0 AS1011-1 ASl011-2 AS1511-1 Choose one that best suits your
Size.mm(inch) 80 (3˝ ) 100 (4˝ ) 100 (4˝ ) 150 (6˝ ) particular application, observing the
Flange Ratings JIS 10K RF, JIS 10K FF, JPI 150 RF, ANSI 150 RF following points:
Max. Operating Pressure 0.97 MPa
1. Select your moe1, the pressure loss
Hydraulic Test Pressure 1.46 MPa
of which is normally held with
Operating Temp. Range 0~110˚C
Max. Working Flowrate (m3/h) 90 100 150 170 49kPa at the maximum flowrate in
Strainer Net 40 in mesh number your particular application, referring
Air Release Max. Allowable Pressure 0.97 MPa to the pressure loss graph on page 2.
Valve (Type Max. Venting Capacity 9m3/h NOTE:The maximum allowable
WS-III) SP.Gr.Range 0.7~1.1 pressure drop across the strainer is
Body Carbon steel casting (SCPH2) rated 98kPa.
Valve Housing Steel plate (SS400)
Materials 2. Always maintain a spare strainer
Strainer Net Stainless steel (SUS304)
net (S).
Air Release Valve Stainless steel (SUS304) (valve seat : Viton)

OPERATlNG PRlNClPLE Exhaust port Rc1/2˝


Included air in the liquid is separated and collected in upper
part of the strainer, and when it will reach the given volume
the liquid level is lowered. Release valve
Following the liquid level, float is lowered, release valve is
Float
opened by linked float, and collected air is exhausted out of
the strainer.

Inflow

Drain port Rc1˝


Strainer body

Strainer net

OVAL Corporation http://www.oval.co.jp

Head Office: Tokyo; Tel. 81-3-3360-5121. Fax 81-3-3365-8605


Beijing Office: Tel., Fax. 86-10-6525-3601. Tel. 86-10-6513-3516
Overseas Branch Offices: Seoul. Singapore. Taipei
PRESSURE DROP

50

•s
Pa P Pa Pa
1m 3 30m 0m
•s
40

Pressure Drop kPa

10

•s a•s
30

m
20 •s
m Pa
0.3
10

0
Model
AS0811-0 0 50 90
AS1011-1
0 30 50 80 100
AS1011-2
0 30 75 105 150
AS1511-1
0 34 85 119 170
Flowrate Qm 3/h

DIMENSIONS

Strainer Net
Flow direction

60 Exhaust port Rc 1/2


D H

D
F
A
B

Unit in mm
Ratio of Open Area
Model D F H Mesh
to Pipe Area
AS0811-0 135 276 478 40 4.2
AS1011-1 135 276 478 40 2.7
AS1011-2 170 383 648 40 4.6
AS1511-1 170 383 648 40 2.0
H

Drain port Rc 1 X 2

Model d L H A B D Approx. Mass, kg Inner Capacity, L

AS0811-0 80 450 330 508 838 310 97 24

AS1011-1 100 445 330 508 838 310 102 24.5

AS1011-2 100 600 455 526 981 310 159 46

AS1511-1 150 640 455 526 981 310 192 48

2
TYPICAL PIPING LAYOUT

Bypass Line

Space
Min. 500mm
Vent line

Vent tank Riser head


h2
h1
Flow Direction
h1 h2
Valve C

Flowmeter
Combination AS

To maintain the stated performance of your combination atmosphere, small quantities of petroleum products or
AS throughout its service life, observe the following vaporized products contained in the discharged gas are
instructions: hazardous. From a safety viewpoint, installing a vent
1. Sequence of component installation-Install, from the inlet tank to hold it is suggested (available upon request).
side, the combination AS and flowmeter,in this order. 5. Provide as long a straight pipe section as circumstances
2. The basic unit must be installed vertically. permit ahead of the combination AS. Avoid turbulence
3. Air pressure inside the combination AS must be higher causing objecst in the stream, e. g. partially open valves.
than the atmospheric pressure to effect venting. Gate valves are recommended.
To fill the flowmeter piping system with liquid, provide 6. Control through-put with valve C on the discharge side
a riser pipe downstream of the meter. of the flowmeter.
A riser head is not necessary in a case where a storage 7. In handling fluids having a tendency to solidify hence
tank is installed downstream of the meter and its tank requiring heating, or highly viscous products, allow the
head acts on the combination AS. valve to open upon confirmation that the temperature has
4. Vent tank installation-In the case the vent is open to the reached the desired level after heating.

When You Make lnquiries,Plase Supply The Following lnformation:


1. Application Unloading Loading Process Control Others ( )

2. Applicable Liquid __________________

3. Applicable Meter Size _______________

4. Bore _______________ mm ( ˝)

5. Flange Rating JIS 10K FF, JIS 10K RF, JPI 150 RF, ANSI 150 RF

6. Strainer Ne Mesh _______________ Mesh

7. Max. Operating Pressure _______________ MPa

8. Max. Operating Temperature _______________ °C

9. Fluid Viscosity _______________ • mPa


s

10. Physical and/or Chemical Properties and


Quantities of Foreign Solids Contained

11. Description of Location for Installation (layout with pump, combination AS, flowmeter, valves, etc.)

12. Quantity Desired _______________ Units

13. Accessories Desired _____________________

3
The specification as of Jan., 2002 is stated in this GS Sheet. Specifications and design are subject to change without notice.

Sales Representative:

89. 2 初版
02. 1 改訂
05. 6 印刷

You might also like