EJ 604269 IDD For Varidor Commissioning/Diagnostic

You might also like

Download as pdf
Download as pdf
You are on page 1of 35
COMMISSIONING / DIAGNOSTICS IDD for Varider 30/ Varidor 30 AP J Varidor 50 Summary This manual provides detailed instructions for the IDD, Medication [| O1 Prepared [06002006] hub KANe | 70864 Reviewed [28082006] _ehratu Kabat [1609006 Nowe Chi] 20.08.2006| patio IDD for Varidor 30 / Varidor 30 AP / Varidor 50 —_____ Commissioning / Diagnostics ve Classfcaton | Lead Offce INVENTIO AG CH-6052 Hergiswil 11530 EB3 EJ 604269 | EN Tvs Manuals the propor of RVENTIO.AG nnd sho ony be used by SOMINDLER personel or nuonzes SANDLER agents for purposes when aren the Incest of SCHINDLER. Ths ces ane mori Is ur niclerual rosery. tho arte conser k must mathe be cased ay anne ne ed or ‘Rarufacung. ner cormancoteso t¥ parise. Apslaston fx sucheoteant chou bo aaaroeses ta: AWVENTIO NG, Potash CH sd Horgowl NV Page 1/35 Table of Contents 1 Safety Advice 3 1.1. General 3 4.2. Symbols Used 3 1.3 Product Speafic Safety 3 2 General Notes 4 3. Prerequisites 6 4 SSMOperation ......... 8 5 Commissioning Using SSM 12 5.1. Preparation 12 5.2 Initial Startup 13 5.3 Synchronization 6 5.4 Setting of Opened and Closed Positions 18 5.5. Fine Adjustment 20 56 Setting Closing Force Limiter 2 5.7 Check Statistics st 8 Commissioning Using HMI 33 7 Diagnostics 24 ID for Varidor 30 / Varidor 30 AP / Varidor 50 Eisoes | ai ‘Commissioning / Diagnostics OB RWENTIONS 2185 1 Safety Advice 1.1 General Safety All persons involved must know and follow all company and local safety regulations, with Requirements special attention to the following: + Make sure that there Is enough light to work safely. + Immediately replace damaged or lost safely equipment + Keop all fools in good eondition, + Follow instructions when using tools, In addition to protective clothing, the following safety equipment must be used: Description Safely Equipment Salely Shoes Hardhat Protective ere ~~ 1.2 Symbols Used gS This symbol indicates a high risk of serious injury. Follow instructions to prevent serious injury or even death. prevent injury or property damage. eS Nate This symbol indicates special or additional information. 1.3 _ Product Specific Safety >—IEEEE + The door drive power supply must be switched off. + The DC linkin the power electronics may have a voltage of up to 400 Vp. x Note ‘Only those personnel familiar and qualified through training are authorized to carry out these procedures, IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Commissioning / Diagnostics EJ 604269 01 CCopyratt© 2006 INVENTIO AS 3/35 2 General Notes Small Service Module 530000839 SSM Description ‘Arrow keys for navigation in menu or for changing parameters Back to previous menu Numeric keypad. ‘SSM*On" Display Red LED: communication error between SSM and door contral Groen LED: SSMis in infrared beam, in communication IR interface Confirms input values FA 2 Z]e]e|~]o]a] a} en] =/2 Esc + Enter: SSM OFF 10D 2 Connectors Da interface ILON service HMI en} | ca} ns] Emergency switch IDD for Varidor 30 / Varidor 30 AP / Varidor SO Commissioning / Diagnostics EJ 604269 at 4/35 Area of Implementation 8 2 8 Implementation Area 4 Receiver and transmitter 2 Rotary switch for IR beam direction 3. IRboam Val rer va0 | va0 | vs0 Function | untae | Range | ela |Win Twin ace Passive | With Aci Cluten Closing Position mm 0.60 2 2 fia lie Opening Position | mm | —350..2000 350 E Efe Closing Speed mmis | 0.800 300 300 | 350] 300 ‘Opening Speed mavs | 0.1000 450 450 | 600 800 Closing Force N 0...200 130 730 | 130] 130 Control = [OforLittconirat| 4 =i 1 for SSM Motor Rotation ~ | Let o 0 [alo Direction + Right Locking Distance | mm 0.50 16 15 | 30 | 30 ‘Closing Locking mms | 0.100 20 2 | «| 40 Speed Opening Locking | mmis | 0..100 40 40 | 50 | 50 Speed Decoleration mms? | 0.1600 300 300 | 350| 200 Acceleration mms? | _ 0.1600 500 500 | 600| 800 IDD for Varidor 30 / Varidor 30 AP / Varidor 50 mimes (idk Commissioning / Diagnostics Copy 00 NVENTIO RS 55 3 Prerequisites Required Hic Components ‘Overview IDD Module 32.001 Emergency Switch ‘Sensor Magneton Belt |+ Varidor 30 + Varidor 30AP and Varidor 50 IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Commissioning / Diagnostics EJ 604269 ot Copyright® 2006 INVENTIO AG Spageninos Tool image Description ‘SSM Tool yp ‘Small service module Multimeter Multimeter with > 25 KON sensiiviy and bad measuring range up to 1000 VDC plus diode test and continuity test. test leads with insulated probe tips Procedure Execute the commissioning steps in the predefined sequence, and do not go to the next step until the work detailed in the previous step has been successfully completed. Decumentation RES: Fe raisia702 Instruction, Specialist Manual [sa1s07205 TDD Wiring Diagram Serial/Parallel aiai3an9 Installation and Commissioning, V30/50 10D speeviatone ‘Abbreviation Description aH Main switch JHCT Door drive switch BKE Clear width of car entrance IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Commissioning / Diagnostics EJ 604269 01 CConsright® 2006 NVENTIO RG 7735 4 SSM Operation SSM Operation _ SSM Operation is performed on two levels: + Use the arrow keys to navigate through the menus, + Input the parameter values by using the numerical keyboard. + Change the parameter in steps by the arrow keys. - Diagram Description _— z 5 Motion control for door and display of ® ® current door status Inspecion Door movement in steps (by ® ® millimeters). Sei Give pos CLOSING_POSITION (66) Set the position, where the panels ® ® have their final losing position or OPENING _POSITION (68) we Set the position, where the panels ® ® are aligned with the door frame. CLOSING_SPEED (29) Bel Cosi spaed Set the maximum speed in the closing direction e Saws) ® ® OPENING_SPEED (28) = Set the maximum sped in the Seta opening direction CLOSING_FORCE (65) This is the representative for the Set Gonna fore maximum closing force allowed 6 g Enter "Special Function’ menu ‘Special funeten_ }-— CONTROL Define who has the control over the door drive Conor IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Commissioning / Diagnostics EJ 604269 01 Copyright© 2006 NVENTIO RG 8/35 ‘Submenu Description ox +} Ky e+ —— ‘Sot drive para No=-< 1022 > mm ‘Solect parameters e- qo ago eo o MOTOR_ROTATION_DIR (21) ‘Set the motor rotation direction. ENCD Set the encoder phases parameter. LOCKING_DISTANCE (67) The zone near the closing position, where the door moves with slow locking speed CLOSING_LOCKING_SPEED (27) ‘Set the locking speed in closing positions OPENING_LOCKING_SPEED (38) Set the locking speed in opening position DRIVE_PARAMETERS Are specialist parameter settinas. STATISTIC Show the Error Log and the counters for opening and obstacle direction. DECELERATION (33) Set the maximum deceleration (Closing and Opening) ‘ACCELERATION (32) Setthe maximum acceleration (Closing| and Opening). IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Commissioning / Diagnostics EJ 604269 ot Cony 2006 INVENTIO AG = 3 For the “Commissioning” and “Diagnostic” procedures are repeatod to switch ON the JHCT and the SSM and to switch OFF the SSM and JHCT. ‘These procedures are described in the following tables. Procedure to No Action Description ‘SSMLED/ SSM Display / Overview Switeh ON th: SHCT and SSM 400, | Switch ON the JHCT. N 401_ | Switch ON the SSM ‘SCHINDLER SSM 1.X + Red LED: OFF +__Green LED: OFF. 402__| Hold the SSMin receiving range of infrared beam. ‘SCHINDLER SSM 1.x + Red LED: OFF + Groen LED: ON. 403 |W. Closed” mode appears. ‘Sas: stopped 404_ | Satine “Control made to "SSM. IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Ev6o4z69 | on Commissioning / Diagnostics CConyrght © 2006 NVENTIO AG 10/35 Procedure to ‘Switch OFF the No Action Description: SSMLED/ SSM Display / Overview| Sater onthe! MRM ccno conor meen rr as in asain SRO mie aa Dos on xeon 406. | Tum OFF the SSM. Foo 407 | Switch OFF the JHCT. IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Commissioning / Diagnostics EJ 604269 1 Cosynght © 2008 INVENTIONS 11135 5 Commissioning Using SSM 5.1 Preparation Preparation Steps No Description Overview 500 | Switch OFF the JH and JHCT. 501 | Plug in the control connectors: + Direct connection with serial or parallel interface: — X58: LON 1/0 with 24VDC = X5P: Parallel !O — Xd: RPHT = X3:JR 45 LUST drive ‘manager — X2: Sensor = X1:230V, + With controller interface LONIOS16 Side switch on 1 — XS: LONIOS = X4: RPHT over bridged — X3:JR-45 LUST drive manager — X2: Sensor — X41! 230 V as prepared =] coorneas 1 Connectors for seria! 2 Connectors for parallel 3 1DD 802 | Switch ON the JH and JHCT. IDD for Varidor 30 / Varidor 30 AP / Varidor 50 : EJ 604269 01 Commissioning / Diagnostics Comsat BOG INVENTIOAAS 12/35 5.2 Initial Startup ke Note + “Initial Sartup’ needs to be performed only during the initial commissioning, + Confirm on ail initial menus (see "Set close pos.” to "Set closing force") until the menu "Status: closed’ appears. If you go past this menu, redo the same operation. Initial Startup No. Action Deseription ‘SSMLED/ SSM Display / Overview| 903. | Turn the JREC to INSPECTION’ 504" | Switch ON the SSM. SCHINDLER SSM 1X + Red LED: OFF + Green LED: OFF. 505. | Hold the SSMin receiving range of infrared beam. SCHINDLER SSM 1.x + Red LED: OFF + Green LED: ON. 506 | Wait until “Status: stopped” or "Status: closed’ mode appears. ‘Status: sepped B07_| Set the *Contror mode to "SSM". Contos <0> Oni 195M SO Coniol= A nas, Oni 1*S3M IDD for Varidor 30 / Varidor 30 AP / Varidor 50 erences | wr ‘Commissioning / Diagnostics Copii ©2008 INVENTIO NG 13/35 No ‘Action Description ‘SSM LED / SSM Display / Overview| 508 | Confirm door closed position. 509 | Confirm door open position: * Telescopic door:x = SFO = $10 | Confirm door closing speed, parameter VLC (1028). 7 os 511 | Confirm door opening speed, parameter] VOP (1028) y ‘Set openg speed @ xa < 450>mmis, IDD for Varidor 30 / Varidor 30 AP / Varidor 50 EJ 604269 o1 Commissioning / Diagnostics Conynant © 2006 INVENTIO AG 14/36 No. ‘Action Description SSMLED/ SSM Display / Overview| $12. | Confirm closing force. SO © 513. | Finish initial startup. IFthe display does not appear as shown, all steps must be repeated, SS ‘Status: stopped z= Te After this procedure. the SSM and JHCT could be switched OFF, see the procedure in the table above "Procedure to Switch OFF the SSM and JHCT’ Set closg force x= 130>N IDD for Varidor 30 / Varidor 30 AP / Varidor 50 ‘Commissioning / Diagnostics EJ 604269 01 5.3 Synchronization = Ta The system must be synchronized following every power failure, The system can perform a synchronization automatically in normal operation, The door is moved until it strikes a mechanical objec. During the synchronization, car and landing door have to be engaged. <= = To start this procedure, switch ON the JHCT and the SSM (if they are switched OFF). ‘See the procedure in the table above “Procedure to Switch ON the JHCT and the SSM”. Synchronization No ‘Action Description SSMLED/ SSM Display | Overview] $14 | Open the menu “Special functions’ Special = functions J 815. | Check the direction of the motor rotation Motor roation ‘Set motor rot 2 ight? #9 + Th door: left "2 ™ ©) =~ TR = # B16 | Check the encoder phase: Encoder Phases: xe (1/820) J + TL/C2/C4: x= <0> TR e IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Ey 604269 Commissioning / Diagnostics a1 (Copyright® 2006 NVENTIO RG 16/35 No. ‘Aation Description ‘SSMLED SSM Display / Overview! B17 | Go back to the “Status” menu. ‘Status: siopped » ED x= <-> mm 518 | Perform “Opening” synchronization travel ‘Slaius open =< 350> mm $19 _| Perform “Closing” synchronization travel. ‘Sialus: closed a) x= < _2>mm Note Alter this procedure, the SSM and JHCT could be switched OFF, see the procedure in the table above “Procedure to Switch OFF the SSM and JHCT” IDD for Varidor 30 / Varidor 30 AP / Varidor 50 ‘Commissioning / Diagnostics EJ 604269 ot Copy © 2008 INVENTIO.NG 17/35 Setting of Opened and Closed Positions 5.4 _ Setting of Opened and Closed Positions Note ‘To start this procedure, switch ON the JHCT and the SSM (if they are switched OFF) ‘See the procedure in the table above “Procedure to Switch ON the JHCT and the SSM”. No ‘Action Description SSMLED/ SSM Display / Overview] 520 ‘Set the door closed position. oy The door must not be blocked by mechanical components. Maintain a gap of 1...2 mm. PBag ‘Set close pos. 2> mm 524 Set the door open position. SO Opening motion must not be synchronized. + Telescopic door: x = + Central door: x = . " Bx, © ‘Set open pos. x= < 350>mm 522 Ghesk door open position. 2 Car door panels (2) must be open flush with the car door jambs (1). Ifnecessary, adjust door opened Position by increasing or decreasing value "X’ by the measured difference. rc 1 Door jambs 2. Car door panels IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Commissioning / Diagnostics EJ 604269 01 (Copyright® 2006 NVENTIO RG 18/35 No ‘Action Description SSMLED/ SSM Display / Overview] 523 Check the mechanical interlock setting, Bie 4 1 Door jambs 2__Car door panels Ifnecessary, adjust the closing position. Feu, Go back one step to check the mechanical interlock setting. 12 Bie ‘Status: dosed x= 23mm ‘Set close pos. xe <2 am Note ‘After this procedure, the SSM and JHCT could be switched OFF, see the procedure inthe table above "Procedure to Switch OFF the SSM and JHCT”, IDD for Varidor 30/ Varidor 30 AP / Varidor 50 eves | | tr Commissioning / Diagnostics 19788 Copyrig@ 2006 INVENTIO AG Travel Curve for Passive Clutch Parameter OMODE (icen)=0 5.5 Fine Adjustment 5 (1087) 8 Travel Curve for Passive Clutch 1 Closing 2 Door closed 3 Opening IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Eu 604269 o1 Commissioning / Diagnostics Comyn ght © 2006 INVENTIONS 20/35 Travel Curve for Active Clutch, 4 vop rte cee (1020) =6 RACCO RSTOP VoPLo (1032) (1036) Race (1038) (1046) 3 RDECO VUNL. if (1035) 1 1 1 1 » ACCC (1034) 1 i VCL —_ PHYOP ke (1033) 1028) al PHYCL, i vLock (ozs) (0078) i (1072) 1 (1032) gg i da AA POPEN 1 petse~ | pLock“ | (1068) 1 (1066) (1987)! ' JLOCK JOPCL 8 (1055) (1056) 8 Travel Gunve for Active Guten 4 Closing 2. Belt stopped 3. Door closed 4 Opening IDD for Varidor 30 / Varidor 30 AP / Varidor 50 E 604269 oO Commissioning / Diagnostics 21/35 Copyright© 2006 NVERTIO AG All Parameters. Accessible by SSM* Drive, Parameters” ni Range and Pera Description ge CTRL |Controling/Status: Lift control = (1004) | Defines who has the control over |2 the door drive Seu] SENPO | Software enable power: O= enable |- (1008) “| Enables the power transistors of the| * = disable frequency converter w ‘Door weight of all door panels 0..500kg | Default value = 120 (1006) PACT — | Actual position: - - (1007) | Actual rotation position count of the ___| door drive shaft PTIMOUNT] Standby mode time out 0.60 min | Default value= 0 (41008) SCG_— |Speed control Plcontrolier gain [Nmmin | - 4040) ‘SOGF_ |Spead control: Preontroler gain _|- 0417_| scaling factor SCTL_ | Speed control: Pl controller ms = (1012) _| readjusting factor V2K_—_ | Displays the current dc-link voltage | - = i017) TIME Time since power on = S (4018) TOP —_ | Operating hours > : (4019) ‘OMODE | Optional mode 0.255 Default value = 0 (1020) 730 passive clutch 30 active clutch 50 active clutch MOVDR | Moving direction: O14 Default value = 0 (1021) _| Sets the moving direction DMMY [Dummy 1 ord Default value = 0 022) MRPHT | Mode of RPHT 0.3 Default value = 0 (1023) PHYUL | Hysioresis unlocking mm = (1024) PUNLO_ |Uniocking position mm = (1025) IVCLLO” | Locking speed close: 0.100 mmis| Defaut value = 20 (1027) | Sets the speed to lock and unlock 30 passive clutch = 20 the system. 30 active cluteh = 20 |V50 active clutch = 40 [VOP [Opening speed: 0.1000 | Default value = 450 (1028) | Sets the maximum speed in opening] mm/s, 30 passive clutch = 450 direction 'V30 active clutch = 800 50 active clutch = 800 VEL | Closing speed: 10...800 mnvs| Default value = 300 (1028) | Sets the maximum speed in closing 30 passive clutch direction 30 active clutch 50 active clutch = 350 a Referencing sped 07.200 mmis| 120 (general) VNUDG |Nudging speed ©. 500 mmis| 200 (general) (4031) IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Commissioning / Diagnostics EJ 604269 01 Conyiant 20 INVENTIOAG| 22/35 Range and Para. Description ee Value RAGGO | Acceleration ramp: 0.1500 | Default value = 500 (1032) | Sets the maximum acceleration, | mmis* 30 passive clutch = 500 used in opening direction 30 active clutch = 600 50 active clutch = 600 RDECG. | Deceleration ramp: 0.1500 | Defauit value = 300 (1033) "| Sets the maximum deceleration for | mmis* 30 passive clutch = 300 ormal movements, used in closing a0 active clutch = 350 irection 50 active clutch = 200 RAGGG | Acceleration ramp: 0.1500 | Default value = 500 (1034) "| Sets the maximum acceleration for | mm/s? 30 passive clutch = 500 normal movements, used in closing 30 active cluteh = 700 irection 50 active clutch = 300 RDECO | Deceleration ramp: 0.1500 | Defauit value = 300 (1035) | Sets the maximum deceleration for | mm/s? 30 passive clutch = 300 normal movements, used in opening 30 active cluteh = 700 Girection 50 active clutch = 800 RSTOP | Emergency stop ramp: 0.1500 | Dafauit value = 1200 (1036) | Deceieratian ramp used if the mimis? a0 passive clutch = 1609] system has to be stopped 30 active clutch = 1500 immediately (for example, when the 50 active clutch = 1200 maximum closing force exceeded) VUNE | Speed at start opening 0.100 mmis} 30 (general) (1037) VOPLO | Locking spesd: 0.100 mms | Default valu (1038) | Sets the lacking speed for opening 30 passive clutch = 40 (1092) TERRES | Automatic evor reset Ort Default value =0 038) - Note ‘To start this procedure, switch ON the JHCT and the SSM (f they are switched OFF) See the procedure in the table above “Procedure to Switch ON the JHCT and the SSM’. Fine Adjustment No Action Description SSMLED/ SSM Display / Overview 525 | Set the closing speed, parameter VCL (1029): 0...600 mm/s. — 5x es i 526 | Set the opening speed parameter VOP SD x= _< 450>mmvs FB, s IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Ey 604269 | 01 Commissioning / Diagnostics No ‘Action Description 'SSMLED / SSM Display / Overview 62T_| Open the menu “Special functions <— Special) |< functions p> $28 | Set the locking distance, parameter PLOCK (1087): 0...30 mm. Sw a © x 530 PE, parameter VCLLO (1027): — Set the opening locking speed, parameter VOPLO (1038): 0...100 mms SFO Fe, se oO ‘Opng ekg speed x= < 60>mms IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Commissioning / Diagnostics EJ 604269 01 CConsrght © 2006 NVENTIO RG 26/35 No ‘Action Description ‘SSM LED / SSM Display / Overview| 531 | Sot deceleration, parameter RDECC(1033): 0...700 mm/s® Ny e Deceleration is valid for both opening and closing Set deceleration x= < 400> mm/s" $32, | Set acceleration, parameter RACCO (1032): 0...700 mnvs* SFO Acceleration is valid for both opening and closing ‘Set acceleration x= < 500>mmis? opening 33 | Check performance of closing and Bie 534 | Exit to “Special functions™ menu. Slalus: closed Commissioning / Diagnostics IDD for Varidor 30 / Varidor 30 AP / Varidor 50 EJ 604269 01 (Copyright© 2006 INVENTIO AG 27/85 No ‘Action Description SSM LED / SSM Display / Overview 535_| Set the “Controf mode to “LIFT Control= <> S O=ih —1=S8M Conol=——<0> r SB, 536 | Tum OFF the SSM. Yoo $37_| Tum the JREC to "NORMAL 1DD for Varidor 30 / Varidor 30 AP / Varidor 50 EJ 604269 o1 Commissioning / Diagnostics Copyright© 2006 NVENTIO AG — 5.6 Setting Closing Force Limiter petaceats We. "Ralion Description SEMLED SoM Display / Overview! 538. | Check the closing force with elevator in normal operation. = The closing force must be checked in the rate speed rangel 53_| No setiing required if checked closing force dos nat exceed 150 N. Continue - with these instructions if checked closing| force exceeds 150 N. 540 | Tum the JREC to “INSPECTION” 541_| Ifthe SSMis OFF, switch ON the SSM ea ‘SCHINDLER SSM 1X + Red LED: OFF + Groen LED: OFF. $42_| Hold the SSM in receiving range of infrared beam. ‘SCHINDLER SSM 1X + Red LED: OFF + Green LED: ON B43_| Sot tho “Control mode to “SSM SH Conkl= CSO Contol= <1 PO Orin 1=88M “oO Door can now be controlled only with SSM IDD for Varidor 30 / Varidor 30 AP / Varidor 50 evesea | 07 Commissioning / Diagnostics Cong 8 208 RVENTIO NG 29785 No ‘Action Description ‘SSM LED / SSM Display / Overview| 544 Select the closing force menu. PBug Set cosg force <190>N B45 ‘Set the “Control mode to“ LIFT ey SB, a oO 546 Turn OFF the SSM Fo-e a7 ‘Check again the closing force and reset] ifrequited, see the first step of "Setting Closing Force Limiter = 548 + Only LUST Door moves in the opening direction and stops during the lacking speed. + Only “Hanging” Door maves iin the closing direction and stop during the acceleration ‘See the table “Error Symptoms During] ‘Synchronization and in Normal Operation” in the next chapter. Se Note Closing force must be rechecked if the acceleration, deceleration or door speed parameters are changed, A the maximum closing force, The closing force limiter must also be active during synchronization and shall not exceed IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Commissioning / Diagnostics EJ 604269 01 Copyright© 2006 NVENTIO AG 30/35 5.7 Check Statistics GRSSESSBCS No ‘Aetion Description ‘SSM LED / SSM Display / Overview| 549 | Switch ON the SSM. FH LS + Groen LED: OFF. 60 _| Hold the SSM in receiving range of infrared beam, ‘SCHINDLER SSM 1.X + Red LED: OFF + Green LED: ON. 561 Control= SOD o=it —_1=S3M Controls <> So, Orin tessw © Door can now be controlled only with SSM, 562, | Select the menu “Special function’. <— Special — |< ‘unctions —p J 553. | Select the menu "Statistics" <= Statistics Mow IDD for Varidor 30 / Varidor 30 AP / Varidor 50 EJ 604269 1 Commissioning / Diagnostics Copyright © 2006 NVENTIO.AG 31/35 ‘Action Description SSMLED/ SSM Display / Overview] Select "Desired Display’. Bi3| SD SO SPO 55 _| Go back to “Control mode™ ow) 2) Note ‘After this procedure, the SSM and JHCT could be switched OFF, see the procedure inthe table above “Procedure to Switch OFF the SSM and JHCT” ‘Status: dosed x= << 2> mm IDD for Varidor 30 / Varidor 30 AP / Varidor 50 EJ 604269 | 01 Commissioning / Diagnostics (Copyright© 2006 INVENTIO AS 32/35 6 Commissioning Using HMI Synchronization ID active. Status “Init error" on HMI as long as the door driver not synchronized. ‘No| Step 800 (Open the door by hand to 50 % open. 601 lights up. see paragraph "Setup Using SSM’ Push button "to close the door and keep five second pushing until LED "Closed’| IFthe door opens in the opposite direction the moving direction has to be changed, B02 ‘Open completely the door by pushing on the button Repeat the procedure until the IDD opens and closes with normal speed, IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Commissioning / Diagnostics EJ 604269 1 (Copyright® 2006 NVENTIO RG 33/35 General Error Codes for SSM & Diagnostics Note ‘To start this procedure, switch ON the JHCT and the SSM (if they are switched OFF) See the procedure in the table above “Procedure to Switch ON the JHCT and the SSM" No ‘etlon Description ‘SSMLED/ SSM Display / Overview) 600 _| Select the menu “Special functions” = |< fenctons 601 | Select menu ‘Statistics’ a tens 602 | Select “Desired Display’. 603_| Go back to “Control mode" e Save coved Sw xe mm IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Commissioning / Diagnostics EJ 604269 01 Copyright© 2006 NVENTIO AG 34/35 No Action Description SSM LED / SSM Display / Overview) Sw 604 | Sot the “Contror mode to “LIFT” Control= <> O=ih —1=SsM Gontrol= << 0> o-i 1=ssM 605 | Tum OFF the SSM YFo-e Foire Failure Error Correction IDD Keeps in Synchronization Made + Check the sensor position and functionality + Check the parameter POPEN (1068) > BT + Check the parameters FORF (1060) and FCRF (1061), 1DD Generates Vibrations and Noise Chock the parameter SCGF_(1011) < 80 Motor Generate Heat Check the parameter PCLSE (1066), set to 2...3mm. Check that the panel is closed completely (PCLSE = 0 means that the belt is under full tension and with PCLSE = 2...3 mm the belt tension is reduced to avoid overheat of the motor) IDD for Varidor 30 / Varidor 30 AP / Varidor 50 Commissioning / Diagnostics EJ 604269 01

You might also like