GROUP 3 ELECTRICAL COMPONENT SPECIFICATION

Part name Symbol Specifications Check

※ Check specific gravity


12V × 100Ah 1.280 over : Over charged
Battery
(2EA) 1.280 ~ 1.250 : Normal
1.250 below : Recharging

Rated load :
24V ※ Check coil resistance(M4 to M4)
100A (continuity) Normal : About 50Ω
Battery relay
1000A ※ Check contact
(30seconds) Normal : ∞Ω
CR-1

※ Check contact
Glow plug relay 24V 200A Normal : 0.942Ω
(For terminal 1-GND)
CR-24
5
4

1
6

2
3

B-BR : 24V 1A ※ Check contact


B-ACC : 24V 10A
B

OFF : ∞Ω(for each terminal)


0, I
Start key
1

B-ST : 24V
ON : 0Ω(for terminal 1-3 and 1-2)
H0 I 40A
START : 0Ω(for terminal 1-5)
4
3
2
6
5

STC BR ACC H

CS-2

A SUPPLY
B SIG
RETURN ※ Check contact
Pressure sensor C 8~30V
Normal : 0.1Ω
CD-6 CD-7 CD-31
CD-42 CD-43 CD-44
CLUSTER TYPE 1 only
(CD-24, CD-32, CD-69)

2 ※ Check resistance
m
rp

Speed sensor 1 - Normal : 300Ω


(For terminal 1, 2)
CD-17

4-38
Part name Symbol Specifications Check

※ Check resistance
Glow plug 24V 200A
0.25~0.12Ω

CN-80

Temperature ※ Check resistance


1 C
sensor 50˚C : 804Ω
-
(hydraulic, 2 80˚C : 310Ω
water) 100˚C : 180Ω
CD-1 CD-8

※ Check contact
Air cleaner Pa High level : ∞Ω
(N.O TYPE)
pressure switch Low level : 0Ω

CD-10

※ Check resistance
Full : 50Ω 6/12 : 350Ω
2 11/12 : 100Ω 5/12 : 400Ω
10/12 : 150Ω 4/12 : 450Ω
Fuel sender 1 -
9/12 : 200Ω 3/12 : 500Ω
8/12 : 250Ω 2/12 : 550Ω
CD-2 7/12 : 300Ω 1/12 : 600Ω
Empty warning : 700Ω

3 4 4 ※ Check resistance

Relay 3 Normal : About 200Ω


24V 20A (for terminal 1-3)
(air con blower) 2
1 2 1 0Ω
(for terminal 2-4)
CR-46

1
4 5 1
※ Check resistance
2
Normal : About 160 Ω
3
Relay 4 24V 16A (for terminal 1-2)
5 3 2 0Ω(for terminal 3-4)
CR-2 CR-36 ∞Ω(for terminal 3-5)
CR-51 CR-62

4-39
Part name Symbol Specifications Check

30
86
87a 87 85 ※ Check resistance
87 Normal : About 160 Ω
Relay 85 24V 16A (for terminal 85-86)
87a 30 86
0Ω(for terminal 30-87a)
CR-4 CR-5 CR-7 CR-9 ∞Ω(for terminal 30-87)
CR-13 CR-35 CR-46

2 ※ Check resistance
Solenoid valve Normal : 15~25Ω
24V 1A
CN-66 CN-68 CN-70 (for terminal 1-2)
CN-88 CN-140
CLUSTER TYPE 1 only : CN-135,
CN-149, CN-236, CN-237, CN-262

1
※ Check resistance
EPPR valve 2 Normal : 15~25Ω
700mA
CN-75 (for terminal 1-2)
CLUSTER TYPE 1 only :
CN-133, CN-242

1
※ Check resistance
Speaker 2 20W
Normal : A fewΩ
CN-23(LH)
CN-24(RH)

※ Check contact
7
6

3
2
1
8

4
12

5
11
10

Normal
11

2
8

Switch ON : 0 Ω(for terminal 3-7, 4-8)


24V 8A
(locking type) ∞Ω(for terminal 7-9, 8-10)
OFF : ∞Ω(for terminal 3-7, 4-8)
10

12
12

9
4

CS-23 CS-50 CS-67 CS-82 0 Ω(for terminal 7-9, 8-10)


CS-83 CS-99 CS-100

※ Check resist
Normal : About 5kΩ
A (for terminal A-C)
+
Accel dial ※ Check voltage
B S -
Normal : About 5V
C - (for terminal A-C)
CN-142 : 2~4.5V
(for terminal C-B)

4-40
Part name Symbol Specifications Check

3 ※ Check disconnection
Normal : 1.0Ω
Room lamp 2 ON : 0Ω(For terminal 1-2)
24V 10W
1 ∞Ω(For terminal 1-3)
OFF : ∞Ω(For terminal 1-2)
CL-1 0Ω(For terminal 1-3)

2
Head lamp, ※ Check disconnection
24V 65W
Work lamp, 1
(H3 Type) Normal : 1.2Ω
Cab lamp
CL-3
CL-3 CL-4
CL-4 CL-5
CL-5 CL-6
CL-6
CL-8
CL-8 CL-9
CL-9 CL-10
CL-10

21V 70W ※Check disconnection


Beacon lamp M (H1 Type) Normal : A fewΩ

CL-7
-
CL-7

1 M
24V 10A ※Check resistance
Fuel filler pump 2 35ℓ /min Normal : 1.0Ω
CN-61

3 ※Check operation
Service meter 2
h S
 upply power(24V) to terminal
16~32V
1 No.2 and connect terminal No.1
and ground
CN-48

1 ※Check operation
DC22~28V
Horn 2 Supply power(24V) to each
2A
terminal and connect ground.
CN-20 CN-25

4-41
Part name Symbol Specifications Check

2 3 ※Check contact
1
Normal : 0Ω(for terminal 1-2)
24V 15A
Safety switch 2 ∞Ω(for terminal 1-3)
(N.C TYPE)
3 Operating : ∞Ω(for terminal 1-2)
1
0Ω(for terminal 1-3)
CS-4
CS-4

24V ※Check contact


Wiper cut switch
(N.O TYPE) Normal : 0Ω(one pin to ground)
CS-53

2
Pa 24V 2.5A ※Check contact
Receiver dryer 1 Normal : ∞Ω
CN-29
10
11
12
13
14
15
16
1
2
3
4
5
6
7

9
8

※Check voltage
REMOCON GND
SPK FRT RH+

Radio &
SPK FRT LH+
SPK FRT RH-
SPK FRT LH-

REMOCON+

24V 2A 20~25V
BACK UP+
TEL MUTE
ANT 12V

CD/MP3 plalyer
(for terminal 1-3, 3-8)
GND
ACC

ILL+
ILL-
NC

NC

NC

CN-27

※Check contact
Washer pump 24V 3.8A
Normal : 10.7Ω(for terminal 1-2)

CN-22

3 1
2

5 3
4 ※Check disconnection
Wiper motor 4
24V 2A
5
Normal : 7Ω(for terminal 2-6)
6 M 2 6

CN-21

4-42
Part name Symbol Specifications Check

3 12V 12V
DC/DC 2 24V 24V (1-2)
12V 3A
Converter 1 GND 24V 12V (1-3)
CN-138

※Check coil resistance


Normal : About 1MΩ
Cigar lighter 24V 5A 1.4W ※Check contact
Normal : ∞Ω
Operating time : 5~15sec
CL-2
CL-2

B+
G
3~ ※Check contact
Alternator 1 I U 24V 50A Normal : 0Ω (for terminal B+-I)
2 R Normal : 24~27.5V
CN-74

M
M
Denso ※Check contact
Starter
24V 5.0kW Normal : 0.1Ω
B+
CN-45

※Check contact
Travel alarm 24V 0.5A
Normal : 5.2Ω

CN-81

1
Aircon ※Check contact
24V 79W
compressor Normal : 13.4Ω
CN-28

4-43
Part name Symbol Specifications Check

※Check contact
Start relay 24V 300A
Normal : 0.94Ω(for terminal 1-2)

CR-23

1 M ※Check resistance
Blower motor 24V 9.5A
2 Normal : 2.5Ω(for terminal 1-2)

※Check resistance
Duct sensor 2 1˚C OFF Normal : 0Ω(for terminal 1-2),
(switch) 1 4˚C ON the atmosphere temp :
Over 4˚C

※Check resistance
Door switch 24V 2W
Normal : About 5MΩ

CS-1
CS-1

Switch 1
(power max, one ※Check resistance
2 24V 6A
touch decal, Normal : ∞Ω
horn, breaker) CS-5 CS-19
CS-26 CS-26A CS-29

※Check disconnection
2
Fusible link normal : 0Ω
60A
(cluster type 1) (connect ring terminal and check
1
resist between terminal 1 and 2)
CN-60 CN-95

4-44
Part name Symbol Specifications Check

2 ※Check disconnection
Fusible link
Normal : 0.1Ω
(cluster type 2) 1 60A
(connect ring terminal and check
CN-60 CN-95 resist between terminal 1 and 2)

※Check disconnection
Master switch 6-36V
Normal : 0.1Ω

CS-74

Pressure switch
Pa 0.5kgf/cm2 ※Check resistance
(for engine oil)
(N.C TYPE) Normal : 0Ω(CLOSE)
CD-18

M- 6
6 5
M M+ 5 ※ Check resistance
NC 4
2 Normal : 1-2 Ω (for terminal 5-6)
Accel actuator 3 1
P- 3 -
SIG 2 0.8-1.2kΩ
P+ 1 (for terminal 1-3)
CN-76

Fuel cut-off
※ Check resistance
(cluster type 1) 24V
Normal : 15-25 Ω