Date/Time Long at 13:02:01 April 4, 2019 Serial Number MP13499 V 10-75 Minimate Pro 6
Trigger Source Geo: 0.540 mm/s Battery Level 3.8 Volts
Range Geo: 254.0 mm/s Unit Calibration August 23, 2018 by Geoinstruments
Record Time 10.0 sec at 1024 sps Geo1 Calibration SE13203, August 23, 2018 by Geoinstruments
Job Number: 1 Mic Calibration SL12822, August 23, 2018 by Geoinstruments
Operator/Setup: YCB/default.nsb File Name MP13499_20190404130201.IDFW
Post Event Notes
Notes Proy 047 Frente Sistema motriz Stracon-GyM
Location: QUELLAVECO SECUNDARIO
Client: ANGLOAMERICAN SMI Ubiación de Geofono: Plataforma de Valvula de tuberia a 200 metros
User Name: ENAEX del disparo.
General:
DIN4150
Extended Notes
60
Microphone Linear Weighting
PSPL 101.1 pa.(L) at 3.275 sec
ZC Freq 39 Hz
Channel Test Passed (Freq = 19.6 Hz Amp = 1724 mv )
L1
L2
20
15
L3
8
MicL 0.0
Long 0.0
Vert 0.0
Tran 0.0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
Time Scale: 0.50 sec/div Amplitude Scale: Geo: 2.000 mm/s/div Mic: 50.00 pa.(L)/div Sensor Check
You created
Printed: April 4, this PDF
2019 (V 10.72 from
- 10.72) an application that is not licensed to1995-2014
Format © print to novaPDF
Xmark printer (http://www.novapdf.com)