Brazed Plate Heat Exchanger

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

e'~I'

Process Equipment
GEA
Ecobraze AB
Division

Brazed Plate Heat Exchangers

Quality provides
the technological
edge.

GEA Ecobraze. The name for plate heat exchang-


ers designed to solve today's problems.
High performance, thermally efficient and cost
~fl
_
..
effective.
~ , .'" G ('0

.
Ourbrazed plate heat exchangers have proved I-;"(~ "...",..

themselves in many years of constant use.


I
Their teclmology incorporates many years of
developmel1t work al1d is subject to cOl1tinuous
i'é"L " "

Ij . I

.
.
detailed improvemel1t. Our comprehensive

.
. . 1<). ." . '.1 rG ~A
product range offers you.a choice of performance <C;
levels, also a wide range of product options
~."
:-' -
,""" 'IÚ;
.:.=-~~\
~,..". - ':,
. ,1 1
G<AE'.',.n A' .1

gives you the flexibility you need to plan the ..


<
'~ :'.
'
'.
!:
.
. ' "

"'~)-r -:rEf\
l1li ¡jiI .~ g"~'~eA~ 1.
,
l J
dimensionil1g of your il1stallatiol1s with com- 1 ...
"' .
plete confidence.
A complete range of accessories enhances
l
1 - -
',&iJ
~'
6E-I\ I
" '
~
'
'"'.
I
L r
:.
H+
1
',.
""'"
"""'.

"

f;4
.. L ("" ~
!8
.'..
..GEAE=.¿J ..1

G:::}\ . '], '<', ,


ti
,

project plal1ning, with a wide choice of inter- . ., ,


" , '

.,
'~. " ' .,'
l1ationally accepted connectiOl1 types.
't:' "':-r
~
.,."""..,..
\
'
""'" "
" .
.

We provide technical support, together with


G--&-'\
- ,l' .,~..'1~_,
¡,me 'w't~~
"~'h"II\>4
,~,',
GS'\ .--
, ~] . ,

-'U.
,...II

'
" .

comprehel1sive product data al1d application


il1formatiol1. Quality and an intelligel1t
I .."..,,~
~ -' .- .

..,--~ '1 [9~t[~


._:

F
product range giving you the techI).ological
\rt
--- <.J 11
....... ,"" , '~ .. . '6- iU
advantage.

The benefits . Flexibilityofchoicefroma


GEA Ecobraze: comprehensive range of products.
. Highefficiel1cy
desigl1sthat
optinÜse operating costs.
. MultipleflowoptiOl1S
that
let you plan with confidence.
Decisions are
better when you
have a choice Installation projects are rarely the same. Because we under-
stand the need for flexibility in the planning process, GEA
Ecobraze offers a complete portfolio of products.
The designs meet the latest heating and refrigeration techno-
logy standards and allow you to customise switching arrange-
ments in arder to develop your own, individual solutions.
There are 6 sizes to choose from -12,18,25,57 and 100.
What you get: H, M or L plate profiles can be selected and arranged in
11 Compact, space-saving design different flow configurations. All units are available in
11 Low weight, yet high standardized plate numbers off-the-shelf or in customized
pressure capability versions on order.

11 High heat transfer performance In addition, we provide adjustable, screwed fittings that
from custom profile design simplify installation. The range of options is designed to
11 Corrosion resistant, stainless give you complete control of your project - no matter where
1 construction the installation may be and no matter what the specifications
to install and virtually may demando
ntenance-free Here is a typical, complex heating and tap water system,
fed by district heat.
nt: not suitable for The system is designed as a combined unit working with
3 different media.

Primary district Town


heating return water tower

Cold
Radiator circuit forward tap water

Primary district
heating return
t

~
Good accessories
are part of the
package

(
eration applications, there can be uneven dis-
igerant within the p1ate heat exchanger. This
~10ss of up to 70% of the active heat exchanger
case for "Mister" - the refrigerant spray. This
Jatented by GEA Ecobraze, distributes afine
ure over the entire flow path surface.
Putting a lid on it - insulation technology.
With GEA Ecobraze, you ha ve a choice of two types of
insulation - a patented, permanent PU-foam barrier, and a
removable shell system. PU foam provides 100% diffusion
tightness and is applied at the factory. It is non-removable
and highly cost-effective. The shell insulation system has the
advantage of being removable for testing or other purposes.

~ .. --.
1

Does exactly what it says -


the installation kit.
It is not unusual for plate heat exchangers to be mounted
in the air or in locations where access is difficult. Mounting
eyebolts are a useful aid that can considerably reduce
installation time. Floor mounted equipment must be totally
secure, too. WIlich is why the support feet can be easily
anchored to the ground.

/'

Safety below zero -


the electric heating pad.
In roof top, or in outdoor installations, there isoften a risk
of water freezing at very low temperatures - when the
system is not rtmning (direct cooling).
The GEA Ecobraze electricheatipg pad¡ built-into the
PU foam insulation, sol ves this problem. It can be
actuated manually or automatically on site.
Technical
data

192 74 9+2.30N 154 40 I 0.46N+0.044N I 0.012


12 I 7.56 2.91 6.06 1.57
0.0394 (9+2.30N)
282 127 9+2.05N 239 84 1I
18 I 11.10 5.00 0.0394 (9+2.05N) 9.41 3.31 1 135N+0.116N I 0.039

525 118 7.5+2.76N 476 69


25 I 20.67 4.65 0.0394 (7.5+2.76N) 18.74 2.72 I 2.3N+0.20N I 0.07

543 281 11.5+2.65N 460 198 I 12.8N+0.48NI 0.16


57 I 21.36 11.06 0.0344 (11.5+2.65N) 18.11 7.80

100 779 314 13.5+2.54N 690 225 I 15.6N+0.86N I 0.27


I 30.67 12.36 27.17 8.86
0.0394 (13.5+2.54N)

N = number of plates

Working parameters
Allowable Working Pressure: up to 40 bar (depending on unit type)
Allowable Working Temperature: mino -160°C max. +200°C DI A

Thermal output: 0.5 to 2.500 kW


Materials Plates and Connections: AISI 316 (1.4401)
Brazing: Copper (Cu) 99.9% ~