CONCRETE NOTES NOTES / LEGEND

1. CONCRETE QUALITY 1.1 THIS SET OF DRAWINGS IS TO BE READ IN CONJUNCTION WITH THE ARCHITECTURAL,
MECHANICAL AND ELECTRICAL DRAWINGS (UNLESS THEY DO NOT OCCUR), AND ANY
1.1 ALL CONCRETE SHALL COMPLY WITH SANS 1200G.
A B C D E F G H 1.2 COMPRESSIVE STRENGTH GRADES:
DISCREPANCIES BETWEEN THEM SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY.
* UNREINFORCED STRIP FOOTINGS -15/19 1.2 NO SCALING OF DIMENSIONS IS PERMITTED ON THESE DRAWINGS. ONLY WRITTEN
* REINFORCED STRIP FOOTINGS -20/19 DIMENSIONS WHICH, UNLESS OTHERWISE STATED, ARE GIVEN IN MILLIMETRES, MAY
* RETAINING WALL FOOTINGS -25/19 BE DEEMED TO BE CORRECT. IF ANY DIMENSION SEEMS DOUBTFUL, THE ENGINEER
* BASES -25/19 SHOULD BE CONSULTED.
* SURFACE BED -25/19
* COLUMNS -30/19 1.3 ALL EXISTING DIMENSIONS AND LEVELS ARE TO BE CHECKED ON SITE AND VERIFIED. ANY
* SLABS AND BEAMS -25/19 DISCREPANCIES OR VARIATIONS FROM THE DRAWINGS SHALL BE REPORTED IMMEDIATELY.
* PILES -30/19 NO WORK SHALL COMMENCE NOR ANY MATERIAL BE ORDERED UNTIL THE ENGINEER IS
* PILECAP -30/19 NOTIFIED ACCORDINGLY.
* MASS CONCRETE PADS -15/19
1.4 ALL WORK IS TO COMPLY WITH THE MOST RECENT REVISIONS OF THE NATIONAL BUILDING
2. CONCRETE PROFILES REGULATIONS (NBR) AND THE LATEST EDITIONS OF THE RELEVANT SABS CODES OF
2.1 SIZES OF CONCRETE ELEMENTS DO NOT INCLUDE THICKNESS OF PRACTICE AND STANDARD METHODS.
APPLIED FINISHES.
3Y12-23-300 T2 3Y12-23-300 T2 2.2 NO HOLES, CHASES OR EMBEDMENT OF PIPES OTHER THAN 1.5 ALL BUILDING MATERIALS ARE TO COMPLY WITH THE LATEST EDITIONS OF THE RELEVANT
3Y12-23-300 B2 3Y12-23-300 B2 SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE MADE SABS SPECIFICATIONS.
IN THE CONCRETE MEMBERS WITHOUT THE PRIOR WRITTEN
1.6 THESE DESIGNS AND/OR DRAWINGS ARE NOT SOLD, AND ARE SUBJECT TO RECALL.
APPROVAL OF THE ENGINEER.
REPRODUCTION OR COPYING RIGHTS ARE RESERVED SOLELY TO GECOR (PTY) LTD UNDER
600mm MIN. LAP COPYRIGHT LAW. THESE DRAWINGS HAVE BEEN DELIVERED AND RECEIVED ON THE
2.3 CONSTRUCTION JOINTS NOT SHOWN ON THE STRUCTURAL
FOLLOWING EXPRESS CONDITIONS:
DRAWINGS SHALL BE TO THE WRITTEN APPROVAL OF THE
29R10-SA-300 STR ENGINEER. (a) THEY ARE NOT TO BE USED IN ANY WAY WHICH MAY BE CONSTRUED AS BEING
AGAINST THE INTERESTS AND/OR BENEFITS OF GECOR (PTY) LTD;
3. COMPACT ALL CONCRETE, INCLUDING FOOTINGS AND SURFACE SLABS,

7R10-SA-300 STR
WITH MECHANICAL VIBRATORS. (b) THEY AND ALL COPIES SHALL BE RETURNED TO GECOR (PTY) LTD
3Y12-22-300 T1 + IMMEDIATELY ON DEMAND;
3Y12-22-300 B1
4. ALL CONCRETE TO BE CURED.
(c) ALL INFORMATION DISCLOSED BY THESE DRAWINGS SHALL BE DEEMED
TO BE CONFIDENTIAL AND TREATED AS SUCH.
5. SLIP JOINTS TO BE USED ON ALL LOAD-BEARING MASONRY WALLS
BENEATH CONCRETE SLABS.

6. BRICKS USED IN LOAD-BEARING CONSTRUCTION SHOULD HAVE A


MINIMUM COMPRESSIVE STRENGTH OF 14MPa. FOUNDATION NOTES

RC BASE BD 7. MASONRY WALLS MUST NOT BE CONSTRUCTED ON SUSPENDED


CONCRETE UNTIL ALL TEMPORARY SUPPORTS ARE REMOVED. 1. FOUNDATION EXCAVATIONS ARE TO BE APPROVED IN WRITING BY THE ENGINEER PRIOR TO
CASTING.

2. A 50MM THICK CLASS 15/38 BLINDING LAYER IS TO BE CAST UNDERTHE FULL EXTENT OF
ALL REINFORCED CONCRETE BASES.

3. BACKFILLING SHALL BE DONE WITH APPROVED MATERIAL PLACED IN LAYERS HAVING A


MAXIMUM DEPTH OF 150MM BEFORE COMPACTION AND EACH LAYER SHALL BE COMPACTED
TO 95% MOD. AASHTODENSITY OR AS DIRECTED BYTHE ENGINEER.

CD 4. MANUAL COMPACTION OF SOIL IS TO TAKE PLACE ONLY WITHIN 50MM OF WALLS.

5. POOR FOUNDING MATERIAL BELOW FOUNDATIONS SHALL BE REMOVED TO THE DEPTH


3Y12-20-300 T2 3Y12-21-300 T2 RC BASE BD ORDERED BY THE ENGINEER AND BACKFILLED WITH MASS CONCRETE OF CLASS 15/38.
3Y12-20-300 B2 3Y12-21-300 B2

01

RC BASE BA RC BASE BA

RC BASE BD

3Y12-10-300 T2 +
3Y12-10-300 B2
3Y12-11-300 T2
3Y12-11-300 B2
RC BASE BD 02
RC BASE BD
10R10-SD-300 STR
RC BASE BA
7R10-SD-300 STR
03 DO NOT SCALE DRAWING
RC BASE BA IF IN DOUBT, REFER TO DRAWING OFFICE

8R10-SD-300 STR
CLIENT PLAN NUMBER
3Y12-13-300 T2
3Y12-13-300 B2 3Y12-18-300 T2
18R10-SD-300 STR RC BASE BD ---
RC BASE BA RC BASE BA 3Y12-16-300 B2 RC BASE BA
2Y12-12-300 T2
RC BASE BD 2Y12-12-300 B2 REFERENCE DRAWINGS

18R10-SC-300 STR
04 NUMBER REVISION DRAWING DESCRIPTION
SF/09-2017/ML (205) 01 FLOOR PLAN

7R10-SC-300 STR 13R10-SD-300 STR


3Y12-15-300 T2
2Y12-09-300 T2 3Y12-15-300 B2
2Y12-09-300 B2

11R10-SD-300 STR

11R10-SD-300 STR
APPROVED BY COUNCIL / CLIENT

12R10-SD-300 STR
RC BASE BA
RC BASE BD 3Y12-14-300 T1 3Y12-17-300 T1 3Y12-17-300 T1
2Y12-08-300 T2 3Y12-14-300 B1 3Y12-17-300 B1 3Y12-17-300 B1
2Y12-08-300 B2 CITY ENGINEER / CLIENT REG. NO. DATE

2R10-SC
AMENDMENTS CODE
3Y12-18-300 T2 A-Y / : REPORT/DESIGN/TENDER /A : BY CLIENT
3Y12-06-300 T2 3Y12-19-300 T2 /B : BY ARCHITECT
3Y12-04-300 T2 2Y12-07-300 T2 3Y12-05-300 T2 3Y12-16-300 B2 0-99 / : CONSTRUCTION
3Y12-06-300 B2 3Y12-19-300 B2
3Y12-03-300 T2 3Y12-04-300 B2 2Y12-07-300 B2 3Y12-05-300 B2 Z / : AS BUILT /C : BY MECHANICAL OR ELECTRICAL
3Y12-03-300 B2 /D : BY RENCA

RC BASE BA
/E : BY OTHER ( )
05

RC BASE BC
DATE INITIAL CODE REVISION DESCRIPTION
RC BASE BD 00-00-08 F.S. A ISSUED FOR APPROVAL
10R10-SB-300 STR RC BASE BE 7R10-SA-300 STR RC BASE BD 7R10-SA-300 STR RC BASE BD 7R10-SA-300 STR RC BASE BE
13R10-SD-300 STR
RC BASE BA
5R10-SD 06

3Y12-14-300 T1
3Y12-14-300 B1

OFFICES

7Y12-25-250 B1

7Y12-24-250 T1
RC BASE BC
RC BASE BD 07
20R10-SA-300 STR

20R10-SA-300 STR

3Y12-16-300 T1
3Y12-02-300 T2 3Y12-02-300 T2 3Y12-16-300 B1
13Y12-26-250 B2

31R10-SD-300 STR
3Y12-02-300 B2 3Y12-02-300 B2
13Y12-27-250 B2 CIVIL, STRUCTURAL & ELECTRICAL ENGINEERS. ENVIRONMENTAL & PROJECT MANAGEMENT

31R10-SD-300 STR
Visit or contact us online at www.renca.co.za

RC BASE BD PROVINCE

Eastern Cape Mthatha (047) 531-1085 admin@renca.co.za

19R10-SA-300 STR
3Y12-14-300 T1 3Y12-14-300 T1
3Y12-14-300 B1 3Y12-14-300 B1

CLIENT

RC BASE BD 3Y12-01-300 T2
3Y12-01-300 B2

MR AND MRS STEMMER


3Y12-15-300 T2
3Y12-15-300 B2

PROJECT
08
PROPOSED HOUSE FOR
RC BASE BB
18R10-SD-300 STR
RC BASE BA MR & MRS STEMMER
ON ERF REM OF 266,
135 LONG STREET,MATATIELE 4730
DRAWING TITLE

FOUNDATION
REINFORCEMENT LAYOUT
PLAN VIEW: FOUNDATION REINFORCEMENT LAYOUT
SCALE 1:50

APPROVED BY RENCA ENGINEERS

ENGINEER/TECHNOLOGIST REG. NO. DATE

SCALE 1 : 50 DRAWN RN

DESIGNED RN CHECKED CP
PLAN NUMBER REVISION NO. DATE SAVED

218140-400 RS-01 01 02/JULY/2018 \PRen


A0