Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 3

Figure III.1.

1: Critical Column

Load calculation
Dead Load
Dead load calculation is shown in table III.1.1.

Load Type Calculation Value


(KN)
Self-weight of slab 25*0.13*6.325 *6.553 134.705
Self-weight of partition wall 6.325 *6.553*0.44 18.237
Self-weight of floor finish 6.325 *6.553*1 41.448
Self-weight of beam 25*0.575*0.380*6.55+ 25*0.575*0.380*6.33 70.357
Self-weight of column 25*(3.353-0.130)*0.61*0.61 9.139
Total 273.886

Table III.1.1: Dead Load Calculation

Live Load
Taking live load = 4 KN/m2
Live load calculation is shown in table III.2.
Floor Calculation Load (KN)
Semi-basement 6.325*6.553*4 165.791

Ground 6.325*6.553*4*0.9 149.212


First 6.325*6.553*4*0.8 132.633

Second 6.325*6.553*4*0.7 116.054

Third 6.325*6.553*4*0.6 99.475

Fourth 6.325*6.553*4*0.6 99.475

Top Floor 6.325*6.553*0.6 99.475

Total 862.115

Table III.1.2: Live Load Calculation

Total Load
Total load calculation is shown in table III.1.3.

Floor Dead (KN) Live (KN) Total (KN)


Semi-basement 273.886 165.791 439.677

Ground 273.886 149.212 423.098

First 273.886 132.633 406.519

Second 273.886 116.054 389.94

Third 273.886 99.475 373.361

Fourth 273.886 99.475 373.361

Top Floor 273.886 99.475 373.361

Total 2779.317
Table III.1.3: Total Load Calculation

Total factored load = 1.5*2779.317


= 4168.975 KN
Increasing by 30 % for EQ,
Total load Pu = 1.3*4168.975 = 5419.6675 KN
Now, we have,
Pu = 0.4*fck*(Ag- Asc) + 0.67*fy*Asc
Assuming percentage of steel, p = 4%
Then,
5419.6675*103 = 0.4*25*(Ag-0.04* Ag) + 0.67*500*0.04* Ag
Solving, we get,
Ag =235637.717 mm2
Considering a square column,
Depth (D) = Width (b) = √235637.717 = 485.425 mm
Adopt, size of the column = b*D
= (500*500) mm
3.1.1 Preliminary Design of Staircase
The plan of staircase is as shown below in fig III.1.2:

Figure III.1.2: Staircase Plan

leffective = + 813+ 3050+ 2032+ = 6200 mm


We have,