Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Vectorworks Educational

CL Version
NOTES - 01/03/20

- This drawing is sized to be printed on a 24"x36" piece of paper.

5 3 2 1 - Horizontal pipes contain Underhung and Overhung units. Please see notes on
4
456
L 457
L 458
L 459
L 460
L plot as well as detail box for further info.
121,122 123,124 125,126
0'-0" 121,122 123,124 125,126
452 453 454
- Movers on 2 PIPE should be hung on taildowns.
4 Top Cyc Pipe
3 2
-10'-9" -5'-3" 5'-3" 10'-9" LINESET SCHEDULE
122
366 121
- When cabling please leave slack for units to shift during focus. Units may need to
361
483 484
125 124 SCRIM, CYC S4 12'6" slide onstage or offstage, or possible move from HI CAT to LOW CAT.
3
Channels: 483, 366, 361, 484 4 2 1
100,101,102,103,104,105,106,107,108,109,110,111 - For focus, please have extra Source4 Barrels, irises, barn doors, and other
are deck units pushed as
19°

103 102 101 111 110 109 108 107 accessories standing by as well as extra frost (R132, R119, R114).
107
upstage as possible.
105 466
481 103
244 464 37 100 465 172 185 38 482 245 245
244 106

US ELECTRIC 1 US ELECTRIC - DS Electric will not be used. US Electric trim is its maxium height.
13 12 11 10 8 7 6 4 5 3 2 31'5" US ELECTRIC 2 9'7"
9 MFL High Trim
MFL MFL MFL 26° MFL
- See Practical Detail box for all set practicals. Please note there 9 set-mounted
flash bulbs and 2 practicaltable lamps (need to be in wireless dimmers).

- All intelligent accessories (CXIs, etc) should be patched into the same channel as
Not in true position. CH: 468 the fixture they are on.
is a deck unit pushed up 88,89,90,91,92,93,94,95,96,97,98,99 - If 2-fering options are needed, please contact designer. Please leave extra
against the lowest opening circuits available at each position for future adds/moves.
371
SR of the set door. 2

26°
135 132
2

26°
372
- Changeover Notes:
DS ELECTRIC DS ELECTRIC 127 32'0" DS ELECTRIC 1 3'3" - Strike DS Electric (1 @ 6" Fresnel)
High Trim
342
1 - Re-space/Re-Hang US Electric
5
1 341 - Move VLX units from Horizontals to Grid
468
138 FLOOR POCKETS FLOOR POCKETS - Adjust VL 1000 Spacing as drawn
188 187 117 114 112
Torm UR 192 190 Torm UL - Add Cyc Ground Row
181
MFL
27
MFL 31 193 31 26° 19° 29 MFL 182

PL PL
136,137,138
133,134,135 13 -4'-9" 11 9 6 4'-9" 5
MFL
2
129,131,132
127,128,130 DS MASKING S1 0'3" - Leave Footlights in place
9 PIPE 14 12 10 8 7 4 3 1 9 PIPE
33 PLASTERLINE 0 0'- 0" - Make other adjustments as indicated.
MFL 34 194 MFL 36
191 -9'-6"
50°
188
26° 50°
186 131 35 - Red Unit = Strike unit
189 463 116 115 113
-1'-6" - Grey Unit = Move Unit

160,159,158,157,156,155

148,147,146,145,144,143
Overhang - Unit with Green Box = Add Unit
Underhang
94 95
Overhang
9 8 2'-6" - Please don't hesitate to contact designer Mike Jarett with any questions,

26°

26°
2'-9"
156 3'-3" 155 3'-6" 13-14-15
1 2 8 CAT HI 84-85-86-87 8 CAT HI
146 145 thoughts, comments concerns: mbjarett123@yahoo.com or 804-241-3842 (cell)

26°

26°
84 86
Not in True Position 10-11-12 -9'-3" 13 28
15 13 28
3'-6" 11'-6" 29-30-31-32 Not in True Position 143 96
-24'-6"
190 27 242 114 29
17'-0"
Underhang 70 108 -22'-6" 71 -20'-9" 109 -18'-3" 72 -16'-3" -14'-6" -13'0" 7-8-9 4-5-6 9'-9" 15'-3" 93 32 19'-6" 92 21'-3" 59 23'-6" 90
7 6

26°

26°
9 7 4'-6"
136 135 15 14 13 12 11 5 4 3 2 1

19°

19°
-3'-0"

26°

26°

26°
10 1'-3" 8 6

26°

26°

26°

19°

19°
8 CAT LO 8 CAT LO 126 125
4'-9"
3 4 444 58

26°

26°
50°
98 51 99 97 11 MFL
50°
MFL 50 87 51 88 52 5'-9"
-5'-9" 414 415 192 416
2 146

26°
6
85 5'-3" 160 5'-6" 107 109 69 14
241
29
204 19°
31 32 89
5

50°
14 4

26°
13 12 11 10 8 5 3 2 1 8 PIPE

26°

26°
26°

26°
294 9 7 6 6'-3"
8 PIPE 293
50 47 87
5 97 12

50°
26° 253 30 14'9"
159
-7'-9" 443
7'-0" 431 3 3 434 NOTES - 02/9/20
7'-9" 57-58-59-60 Underhang
9'-3" 58
145 147 - The Scrim has been cut so all cyc cabling are exposured. So they need to nice,
3

26°
107 108 68
4 3 neat, clean, and organized.

26°

26°
10'-3" 10'-6" 3 1 2 9'-9" 60 10'-3" 59 89

26°

26°

26°
154 153 PROPS SHOP 9'-9" 144 9'-6" 143
9'-9" 10'-3" 2 1 57

26°

26°
50 9'-9" 51 52
6 7 - Please don't hesitate to contact designer Mike Jarett with any questions,

26°

26°
2

26°
48 88
157 158 67
10'9" 49 thoughts, comments concerns: mbjarett123@yahoo.com or 804-241-3842 (cell)

Overhang
2

26°
139,140,141,142
11'6"

Underhang
49

Overhang
421 1 1 422
11'-9"

148 144
11'-3" -2'-9" 2'-9" 5'-6" 11'-3" 442
1 2

26°

26°
-14'-6" 19 21 50° 176 25 176 25 19° 181 23 14'-3"
101 15'-3" 7 PIPE 64 -24'-6" 65 -19'-9" 105
50°
27 26 25 33 124 123
134 133
18 16 17 15 13 12 10 8 7 6 4 3 2 1

26°

26°

26°
14 11 9 5 7 PIPE

26°

26°

26°
1 1

26°
26°
8 9 Underhang

26°

26°
56 54 55 MFL MFL MFL MFL 19'-9" 45 21'-6" 85 24'-6" 46 15'-3" 14'-6"
24 331 9 333 259 185
83
156
15'-3" 155
15'-6" 411 26° 412 413 USL HI HOR
103 66 441
19° 26° 26° 26° 184 26° 2 64

10 8 202
7 CAT LO 12 11 9 7 6 5 4 3 2 1 7 CAT LO

26°

26°

26°
26°

26°
USR HI HOR -2'-6" 183
7/8 SR LO 7/8 SR HI 7/8 PIPE SR -17'-0" -15'-6" 13'0" 14'-6" 16'-0" 44 17'6" 81 7/8 PIPE SL 7/8 SL HI 7/8 SL LO
80 53
251
14 15 178 191 271 17 16 186 17 3
262 Not in True Position 20
7
Not in True Position
177
-7'-3"
49-50-51-52 53-54-55-56 19-20-21 1-2-3 25-26-27-28

SPEAKER

SPEAKER
1
SPEAKER
165

19 21 1 22 1 22 181 23 154
266 62
203 26'-3"
2 6 CAT LO -9'-3" 2 6 CAT LO 1

26°
5 6 4 3 1

26°
4'-9" 9'-3"
166
101 -25'-9"
MFL MFL MFL MFL
16-17-18 82
33
261 Underhang
8
21'-6" 21'-9" 1 1

26°
26°
-24'-6" -4'-9" 15'-6" 17'-3" 19'-9" 24'-3" 150 149
152 151 61 102 62 103 63
26° 18 64 63 21'-6" 61
Underhang 153
24 83
Underhang 5 2 1

26°

26°
1 2 10 9 8 7 6 4 3 2 1 6 PIPE

26°

26°

26°

26°
26°

26°

26°

26°

26°
26°

26°

6 PIPE 2 -21'-9"
80-81-82-83 61-62-63-64
166,165,164,163,162,161

142 141
-21'-6" -19'-9" -17'-3" -15'-6" 41 81 42 43 -21'-9"
Underhang

164 162 83 82 81 80 21
Instrument Key

Overhang
252 265

154,153,152,151,150,149
16
Overhang

266

3 5/6 CAT DSR 5/6 CAT DSL


132 131 152 151
166

3 4 4 3

26°
26°
26°

26°

-24'-3" VLX WASH


121
163 161 262 -24'-3" 122
24'-0" 24'-3" 153
4
3 Underhang
165
1'-3"
19° 37-38-39-40 19°
265

154
5 PIPE 2 1 11'-0" 5 PIPE
4
DSR LO HOR 171 256
VL 1000 TI
39 35 261
DSR HI HOR 19° 19° 19° 19° 19° 19° 19°

33-34-35-36
5 CAT LO 7 6 5 4 3 9'-6" 2 1 5 CAT LO Underhang
5/6 CAT DSR 5/6 PIPE SR
9 23
22-23-24 10 22 11 40 12 38 255 37 257 36 13 34
5/6 CAT DSL
-4'-9" 4'-9" 11'-0" DSL HI HOR
5 CAT HI 5 CAT HI DSL LO HOR
Not in True Position 1 Not in True Position
0'-0" VL 2500
19° 19° 19° 19° 126
124 19°
483
484
222
221 122
126 50°
1'-6" 19° 13'-0"
6'-3"
4A PIPE -13'-0" 10 8 7 6 5 4 3 1 4A PIPE
9 2
4 46 5 45 243 44 201 43 6 332 7 66
10'-3"
-10'-3" 41 8 65
432 42 433
-6'-3"
4 CAT LO 4 CAT LO
Not in True Position Not in True Position VL 1100 TID
VOM DWNRIGHT CTR VOM DWNLEFT CTR
2'-0"
45-46-47-48 41-42-43-44 65-66-67
70
HAND RAIL DR 161
2 1

311
26
° 4'-6"
SPEA
77 KER KER 166
3 SPEA

4 291 -2'-0" 68 1
VL 1000 TSD
4 322 162
1 2
169
172
2
461
-4'-6"
78
2K is on taildown from 165 462
HELL WALL HOUSE/AISLE
HELL WALL 2 Pipe - Needs to shoot

°
HAZER

19
170
-9'-3" under Speaker 9'-3" 5'-6" 1 2
2 168
167-168-169
0'-0"
170-171-172 19
°
10'-6" 500 501
231
1
°
232 TAILDOWN C TAILDOWN A 26
1
NOT IN TRUE POSITION 1
TAILDOWN B 1
NOT IN TRUE POSITION 3 House Aisle
312 171 167 L
NOT IN TRUE POSITION
3 3 401
Lustre 2 with Cyc Adapter
321 402 403 292
-10'-6" 5'-0"
-9'-3" -4'-9" 9'-3" VOM DSL
77-78-79 19° 19° 19° HAND RAIL DL
PRACTICALS Strand 6" Fresnel 750w
2 PIPE 3 2 0'-0" 1 2 PIPE
1 2
1 73 2 72 3 71 Side Tables - Scene 7

MFL
272 273
PAR 64 MFL 1kw
2 CAT LO 2 CAT LO
2/3 CAT USR 2/3 PIPE SL 1 4
313 2 3 5 PAR 64 NSP 1kw
2 137 136 133
2 134 130
281 282 283 284
320
74-75-76 71-72-73 68-69-70
285
Camera Flashes - Scene 8
19deg Source4 750w

19°
26deg Source4 750w

26°
1 PIPE 1 PIPE 1 Hazer
471

36°
50°
50deg Source4 750w
314 1 1
319 Strand 6x12 1kW

Strand 6x16 1kW

26deg Source4 Lustr


S2

Set Mount

Studio 2k 8" Fresnel

THEATREVCU – HODGES THEATER

4
140 3
142
2 141
1 139
MACHINAL
LIGHT PLOT
315 318
316 317

BOOTH
Director: KEITH BYRON KIRK Set Designer: SCOTT BRADLEY Lighting Designer: MICHAEL JARETT
173-174

Asst. Designer: AUSTIN HARBER Master Electrician: SREYPECH AN AME: DAKOTA CARTER
DECK LAYOUT
CL Lighting Sup: C. DeAngelis/W. Corey Moving Light Tech: HANNAH BECKNER

Vectorworks Educational Version


SCALE - 1'4" = 1'-0" REV. DATE - 02/11/2020 - REV 13
2
1
2

You might also like