RECTIFICATION PROPOSED
‘Method
Defect Description
Rectification
Tevel difference, Targe crack on
retaining wall/ side wall of ramp/
‘parapet wall; separation between
‘paving & drain; kerb cracked &
settled
Replace the affected portion of the elements after
consolidating the ground
Replace the affected area of premix after consolidating the
2 | Crack on the premix sone
Map! plaster eracks on the
3 | wallsurface finish worn offf Hack & replace the plaster! surface finish
surface finish chipped off
4 | cackins concrete Inject the crack with a low viscosity epoxy resin, Monitor in
vuctural future for reappearance
‘Corrosion & pitting on side Face of
5 | beam/ Corrosion on anchor boll | Remove rust stains & apply anti-corrosion paint
‘Corrosion on weld joint at beam
«6 _| Separation crack between Hack the plaster and provide wire mesh at the interface of
structural member & wall concrete & masonry and re plaster the surface
Map cracks; delamination of
7 | Sifcetinish on paving: foor | Hack & repair with polymer mfed mora! no shrink
finish Crack on wallfvertical crack | ®" Place the conere "
‘Cracking and delamination on —_| Haack & repair with polymer modified mortar or non.shrink
8 | railing kerb/ railing anchorage’ grout afer treating the corroded anchorage! anchor plate!
‘russ anchorage anchor bolts
‘Crack’ separation? damagel
9 | watermarks/ paint peeling on false | Block the source of leakage. Replace the false ceiling panel
ceiling
Delamination of surface finish or
10 | taster on ker wall’ Noor Hack & replace the affected surface finish area
11 | Paiat peeling off on coluran Remove loose paint & apply a waterproof protective
supporting cantilever Awning | coating
12 | Map ctacks with watermarks & | Grou seal the crack with a low viscosity flexible epoxy.
efflorescence on RC slab soffit | Prevent ingress of water from top
13 | Crack on floor tiles Replace the floor tiles
‘Watermarks; water seepage: sins | APPLY waterproof prowetve coating onthe wall afer
14 | & paint popping up on wall/slab a =
solfit
15
Delamination & cracking of plaster
‘on the wall at the interface of
waterproofing membrane & plaster
Hack & replace the waterproofing membrane & plaster at
the interfaceMethod Defect Description Rectification
Level difference between side wall
of driveway & kerb/ Crack Fill the cracW’ gap with non-shrink grout and raise the level
16
between kerb & side wall of
driveway
‘with non-shrink grout or concrete topping, if required
0
Settlement at ground near BBQ pit
platform 1
Fill the gap with soil and consolidate
18
Plaster popping up/ spalling on the
slab soffit
Hack & repair with polymer modified mortar or non-shrink
‘grout after treating corrosion in rebars, if any
19
Heavy corrosion with loss of metal
‘Remove the rust stains and apply anti-corrosion paint,
Replace the member if loss of sectional area >20%.
20
Deflection of lamp posts besides
Remove the lamp posts and consolidate the base. Re-fix the
parapet/ retaining wall lamp posts upon consolidating and levelling the ground
(Cracking and delamination of filler
21 | all under BBO pat Replace the filler wall afer consolidating the ground
Mild to Heavy corrosion on steel
22 frames! corrosion with loss of ‘Strengthen / replace the heavily corroded frame members
staircase members