Inspection

# Line/ Equipment No Report No


Done
Location: BADP-A

80-P-501-6101x Yes OC-RBI/BA/SJ-1396

80-P-500-6101x Yes OC-RBI/BA/SJ-1396

80-P-521-6101x
Yes OC-RBI/BA/SJ-1396
OR
WH10 3"
Flowline

80-P-522-6101x Yes OC-RBI/BA/SJ-1396

WH 07 3"
80-P-519-6101x Yes OC-RBI/BA/SJ-1396
Fllowline

WH 17 3"
80-P-504-6101x Yes OC-RBI/BA/SJ-1396
Flowline

Location: BADP-G

100-VL-2457-6143 Yes OC-RBI/BA/MFF-1002/14

50-VL-2462-1149 Yes OC-RBI/BA/MFF-1002/14

Gas lift
header 150" 150-PG-1674-6143 Yes OC-RBI/BA/MFF-1002/14
line

Gas lift 50" -


near FY TBA
0042
50-PG-XXXX-61430
Gas lift 50"
to 85S TBA

Location: BAP-A

Test Sep V-
150-PG-011-3101x Yes OC-RBI/BA/ NS-214/15
500
Test Sep V-
150-PG-011-3101x Yes OC-RBI/BA/ NS-214/15
500

80-P-529-6101x Yes OC-RBI/BA/ MFF-113/15


WH58L/S
line
80-P-530-6101x Yes OC-RBI/BA/NS-214/15

V-100 drain
80-D-002-1101x Yes OC-RBI/BA/ MFF-113/15
line

200 -P-123-1510x No
150-P-126-6143 Yes OC-RBI/BA/NS-214/15

200-BD-021-11430 OC-RBI/BA/NS-214/15
Yes
R-9110 gas
lift bypass 150-PG-092-6101x Yes OC-RBI/BA/ MFF-113/15
line
Recommendation API Analysis

Location: BADP-A
1. MAT: 3.14 mm
1. To replace corroded section 2. Remaining Thickness: 2.0 mm
3. Remaining Life: 0.2 yrs
1. MAT: 3.14 mm
1. To replace corroded section 2. Remaining Thickness: 3.3 mm
3. Remaining Life: -2 yrs
1. MAT: 3.15 mm
1. To replace corroded section
2. Remaining Thickness: 1.9 mm
3. Remaining Life: -2.2 yrs
1. MAT: 3.14 mm
1. To replace corroded section 2. Remaining Thickness: 3.7 mm
3. Remaining Life: 1.4 yrs

Not applicable Not applicable

1. MAT: 3.14 mm
1. To replace corroded section 2. Remaining Thickness: 3.5 mm
3. Remaining Life: 0.9 yrs

Location: BADP-G
1. MAT: 4.02 mm
1. To replace damaged section 2. Remaining Thickness: 2.7 mm
3. Remaining Life: -2.3 yrs
1. MAT: 2.12 mm

1. 100% blasting and mechanical cleaning and 2. Remaining Thickness: 4.5 mm


paint on the corroded section 3. Remaining Life: 57.5 yrs

Not applicable Not applicable

Location: BAP-A
1. To install PVC wrapping tape at flange and 1. MAT: 2.88 mm
valve connection
2. To conduct spot repair and touch up on 2. Remaining Thickness: -3.7 mm
corroded valve
3. To replace corroded bolting 3. Remaining Life: 1.7 yrs
1. MAT: 3.14 mm
1. To conduct spot repair and touch up
2. Remaining Thickness: -0.8 mm
painting at the corroded section
3. Remaining Life: 5.9 yrs
1. MAT: 3.14 mm
2. Remaining Thickness: 4.8 mm
3. Remaining Life: 5.9 yrs
1. To install PVC tape wrap at flanges and valve 1. MAT: 0.61 mm
connection
2. Spot and sweep blast at the corroded 2. Remaining Thickness: 0.5 mm
section. 3. Remaining Life: -0.2 yrs

Not applicable Not applicable

Not applicable Not applicable

Not applicable Not applicable


Remarks

Refer VI-03 (photo no 5 - 15)

Refer VI-03 (photo no 6 - 11)

Assuming the findings captured near well no 10L

Assuming the findings captured near well no 10S

1. To confirm the well no either 17L or 17S. There


are no well no 17L.

2. Analysis and recommendations are based on


assumption findings captured near well no 17L
(80-P-519-6101x)
3. Findings not captured in previous inspection
report.

Refer VI-01 (photo no 1 and 2)

Finding not captured in the inspection report

To confirm the line no at site. P&ID no BADP-G-P-


0004-F not updated

Refer VI-02 (photo no 2)


Refer VI-02 (photo no 2)

Refer VI-01 (photo no 1 to 3)

Finding not captured in the inspection report.

Finding not captured in the inspection report.

No inspection done at this line due to ongoing


piping replacement at the time of inspection.