RF Amplifier To Rife Tube Matching Network: V1.01 19 July 2012

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

RF Amplifier to Rife Tube Matching Network

Copyright (c) 2012 by Ralph M. Hartwell II


V1.01 19 July 2012

C2
( see text )

Phanatron
RF from
or
SSQ-2F or PA1 L1 L2 C1
External Electrode
RF Amplifier ( see text )
Plasma Tube

Wires to plasma tube


18 to 24 inches in length

NOTE: The values specified here are for use with a 50 Ohm coaxial cable with a length of
24 feet / 7.35 meters between the RF source and the matching network. Using a different
length of coaxial cable will require adjustment to the value of C2.
C1 - between 15 to 35 pF. This capacitor is made from a length of RG213 coaxial cable.
C1 - 6" active length, made from a 7" length of cable when used with a Cheb 1" x 14" SSQ-PT
external electrode tube..
C1 - 7" active length, made from an 8" length of cable when used with a Cheb 8" Phanatron tube.
C2 - 2200 pF Mica 500 Volts when the coupler is used with a Cheb 8" Phanatron tube.
C2 - 1100 pF Mica 500 Volts when used with a Cheb 1" x 14" SSQ-PT external electrode tube.
L1 -11 turns #14 THHN copper wire close wound over the center of L2.
L2 - 94 turns # 18 enameled copper wire close wound on a 6" long x 2" diameter
length of PVC pipe.
Coil form is a 7" length of 1-1/2" Schedule 40 PVC pipe.

You might also like