Indicators Series: Max 420 Bar
Indicators Series: Max 420 Bar
Indicators Series
FPC
Filter Indicators
FPC
TYPICAL APPLICATIONS
Industrial Equipment
Mobile Equipment
Marine/Offshore Applications
Competitor Housing
SPECIFICATION
Maximum Operating Pressure: The differential pressure values of
420 bar (250 bar for aluminium) standard indicator models:
1.0 bar ± 0.1
Maximum Differential Pressure:
1.2 bar ± 0.1
210 bar
1.5 bar ± 0.2
Working Temperature Range: 2.5 bar ± 0.2
-20˚C to +85˚C 5.0 bar ± 0.4
7.0 bar ± 0.5
Material of Housing : 8.5 bar ± 0.5
Brass, aluminium or stainless steel (Indicators for other differential pressure values
Seals: are optional)
NBR (Nitrile) or FPM (Fluoroelastomer)
FPC Pressure Indicators are typically used with the following filters: G1/8
On-line return filter series: 1000 and 1050.
1.0 bar 1.0 bar
Tanktop return filter series: 1014, 1025, 1200, 1070, 1090, 1095 and 1110.
186
06 FILTER INDICATORS 28/6/02 11:40 am Page 187
Filter Indicators
FPC
F6 W3 W6
Plastic A 98 105 105
B 27.5 32 32
No C Ø16.2 Ø19.78 Ø18.83
rt
±0.05 ± 0.06 ± 0.06
pa
Connect
ed
D 3/4*-16 7/8-14 7/8-14
Fix
A
Normally Closed (N.C)
P1 High pressure
COM
B
O-ring 13.1x1.6
C
Pin 2 3 1 D
P2 Low pressure
P1-P2
B
B
Low Pressure
High Pressure
No
Connect C C
D D
Normally Closed (N.C)
N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O.
125VAC 5 1.5 0.7 3 2.5 1.3
Pin 1 3 2
250VAC 3 1.0 0.5 2 1.5 0.8
8VDC 5 2 5 4 3 20 10
125VDC 0.4 0.05 0.4 0.4 0.05 max. max.
250VDC 0.2 0.03 0.2 0.2 0.03
O - ring O - ring
55.5
O-ring 16.0x2.0
32
Low pressure
High pressure
27.5
16.1 x 1.6
17 x 1.5 O - ring
O-ring 13.1x1.6 O - ring
ø19.78 +-0.06 ø18.83 +-0.06
High pressure
/4-16 UNF-2A
3
FPC R Visual
Dimensions as FPCV (F6 Model) Note: W3 & W6 (FPCV ONLY) Auto Reset
Red button pops up (Manual Reset)
187
06 FILTER INDICATORS 28/6/02 11:40 am Page 188
Filter Indicators
FPC
rt
max 300 mA -10...36VDC UNF-2A UNF-2A UNF-2A
pa
A
ed
Yellow LED’s
Fix
Red LED
PNP
+V
O-ring 16.0x2.0
3
FPC.F
+10...36VDC
B
PNP 1 Load High pressure
Normally
open 2 Load O-ring 13.0x1.6
(N.O) C
0V Low pressure D
4
max 300 mA
-10...36VDC
W3 Model W6 Model
Operation
Below temp +20°C only green LED is active
regardless of the differential pressure level.
Operation above temperature +20°C:
B
Low Pressure
3/4 2 active
High Pressure
4/4 1 active
C C
(Indicators for other diff. pressure values are optional)
Enclosure class IP65
D D
Electrical connector DIN 43650
Input supply voltage +10 to36 VDC
Indication output 300 mA/36 VDC
Output type: (N.O) Normally Open NPN or PNP
188
06 FILTER INDICATORS 28/6/02 11:40 am Page 189
Filter Indicators
FPC
PRESSURE INDICATORS
FPC M VISUAL (GAUGE)
Green Area
Ø40 Normal Operation
Red Area
Change the Filter Element
0.9BAR 1.6BAR
32
HEX 14 42
G1/8 2.5BAR
Contact configuration
67
ø30
HEX 24
TECHNICAL SPECIFICATIONS
Max.operating pressure 80 bar
10
38 TECHNICAL SPECIFICATIONS
Max.operating pressure 150 bar
Max. fluid temperature 100°C
Material of housing Passivated steel
Thread G 1/8 K
Indicating pressure 1.0 bar +/-0.15
30x30 (Indicators for other diff. pressure values are optional)
Enclosure class IP65
Max. operating voltage 250 VAC
Current 2.0A (resistive)
0.5A (inductive)
C3 2NO
74
44
1NC
56
Contact configuration
3
10
NO 2 1 NC
HEX 27 G1/8K
Fixed part
189
06 FILTER INDICATORS 28/6/02 11:40 am Page 190
Filter Indicators
FPC F/U/T/V/R/G/H/M
ORDERING INFORMATION
Table 1 Table 2 Table 3 Table 4 Table 5 Table 6
FPC – –
190