Simrad IS80
Wind Instrument WI80
English
English
3s
Single key press with time
SELECT
indication
3s
Combined key press with time
MODE
SETUP + SELECT
indication
SELECT
Repeated key presses on single
key
A. 1 A.2
1s
Automatic change in LCD readings
with time indication (no key
0FFS presses required)
1 Introduction................................................ 5
General information.......................................5
Instrument layout..........................................5
2 Installation.................................................. 7
Location of the unit........................................7
Panel mounting..............................................7
Cable connection and interface........................8
Securing the cables........................................9
Interconnecting instruments............................9
3 Operation.................................................. 13
Turning the WI80 on..................................... 13
Using the keys............................................. 13
Selecting active display mode........................ 14
Bargraph.................................................... 15
Backlighting................................................ 16
Error Alarm................................................. 16
Maintenance................................................ 17
Operation flow chart..................................... 18
5 Spare parts................................................ 25
Spares and auxiliaries................................... 25
SimNet cables and accessories...................... 25
6 Specifications............................................ 27
Technical specifications................................. 27
Dimensional drawing.................................... 28
General information
The WI80 Instrument presents you with relevant wind
information on a combined analog and digital display.
Adjustable backlight for night operation is provided
as well as adjustable intensity on the LED displays for
operation in sunshine.
Instrument layout
The WI80 display includes bargraph, dial with pointer
and LED display. Modes of operation and units for
measure are indicated by monitor diodes.
The instrument is
operated by 2 keys.
These are used to switch
between display modes,
to set parameter values
and to adjust background
illumination.
Introduction | 5
Blank page
6 | Introduction
2 Installation
Panel mounting
The mounting surface must be flat and even to within
0.5 mm.
Installation | 7
Cable connection and interface
Signal input, network and power supply are wired to the
enclosed terminal block that is to be plugged in on the
rear side.
The instrument is delivered with a 0.3 m SimNet cable
with a standard SimNet plug in both ends. One plug
1 must be cut off and the wires connected to terminals 3
through 6 according to the color codes shown below.
TERMINAL
SIGNAL TYPE COLOR
NO
1 GND - Supply -
8 | Installation
Securing the cables
Use the eclosed tie wrap to secure the cables to the
instrument.
Interconnecting instruments
Interconnect a series of instruments by using a SimNet
power cable with termination and T-joiners as illustrated
below.
Instrument
Supply 12-24V
SimNet 12V
Supply
(Red disk)
SimNet SimNet SimNet
T-joiner T-joiner T-joiner
Installation | 9
Installation setup
SimNet, NMEA0183 and Demo mode are selectable
inputs on the WI80. After installation, the system must
be configured to read the preferred input signal before
the instrument is ready for use.
MAIN INSTALLATION
The Installation MODES 10 s SETUP
Setup is accessed MODE
+
as shown in the SETUP SELECT
- RELATIVE - INPUT
illustration. SIGNAL MODE
SETUP
- TRUE
- OFFSET
5s
- GEO-
GRAPHIC
MODE
SETUP + SELECT
MAIN INSTALLATION
MODES 10 s SETUP 1s
MODE
SELECT
SETUP + SELECT
- RELATIVE - INPUT
MODE
51 0A.183 +
SIGNAL
- TRUE
- GEO-
GRAPHIC
5s
- OFFSET 1 A.2 SETUP SELECT
MODE
SETUP + SELECT
3s
SimNet 51
NMEA183
Demo
10 | Installation
Offset adjustment
Any residual error in the apparent wind angle can be
adjusted manually by entering an offset angle.
A positive value (no sign) indicates starboard offset
angle, while an offset angle to port is indicated with
negative value (negative sign).
The illustration below illustrates the required key presses
to offset the angle to 12.1°.
Range: +/-99 Default: 0.0
MAIN INSTALLATION 1s
MODES 10 s SETUP
MODE
+
SELECT 3s
SETUP SELECT
- RELATIVE - INPUT
SIGNAL
- TRUE
- OFFSET
SELECT 3s
1s
SELECT
MODE
02. 1 12. 1 SETUP + SELECT
3s
12. 1
Starboard (+)
+/- 1s
SELECT
MODE
-12. 1 SETUP + SELECT
3s
-12. 1
Port (-)
Installation | 11
Blank page
12 | Installation
3 Operation
LED POINTER
MODE
Initial After 1 second
Relative
Actual wind Wind direction
True speed according according to
to active mode active mode
Geographic
Operation | 13
KEY MODE/ACTION
KEY
PRESS DISPLAY MODE SETUP MODES
MODE Short Go to next main display Go to next Setup mode
SETUP
3 sec. Switch to User Setup Switch to main display
Select parameter
SELECT Short Increase light level
Adjust parameter
None /
3 sec.
Change to next digit
MODE Save setting and return to
SETUP SELECT Short
+ Setup parameter
Enter Installation
10 sec.
Setup
5 sec Return to main display
14 | Operation
Bargraph
The bargraph operates as a releative wind gust indicator.
The direction of the wind gust is displayed as shown in
the table below.
PORT STBD
PORT STBD
PORT STBD
PORT STBD
Operation | 15
Backlighting
The backlighting is adjusted by pressing the Light key
SELECT
when the instrument is in normal operation.
Current light setting will be indicated with the right LED
digit.
The light setting affects the diodes, the digital display
and the backlight as shown in the table:
Error Alarm
In the event the error indicator is lit, the
instrument is not operable and service/repair is
required.
16 | Operation
Maintenance
The IS80 instruments are “repair by replacement” units,
and the operator is therefore required to perform only a
very limited amount of preventive maintenance.
If the unit requires any form of cleaning, use fresh
water and a mild soap solution (not a detergent). It
is important to avoid using chemical cleaners and
hydrocarbons such as diesel, petrol etc.
If a weather cover is available this should be put on
when the unit is not in use.Operation flow chart
Operation | 17
18 | Operation
INSTALLATION
MAIN MODES USER SETUP
SETUP 10 s
3s
Input Type MODE Relative wind Display Damping
- SimNet SETUP + SELECT - Damping 0
True wind MODE
- NMEA0183 - Damping 1
SETUP
- Demo Geographic wind - Damping 2
- Damping 3
Offset 5s
- Adjust setting Wind Speed Alarm Limit
- Adjust limit
MODE
SETUP + SELECT Wind Shift Alarm Limit
- Adjust limit
Speed Unit
- m/s
Operation flow chart
- kts
- mph
- km/h
5 min - bu
General
The factory default
MAIN USER
settings may all be MODES SETUP
changed in the User
- DISPLAY
setup, accessed DAMPING
MODE
Detailed illustrations - TRUE
MODE
SETUP
- WIND SHIFT
ALARM
SETUP
Display damping
The damping factor indicates how fast the display will
respond to changes in wind readings. The setting affects
both the LCD and the pointer.
The higher the damping factor the more stable display
reading on the instrument.
Range: 0 - 3 Default: 0
The illustration below shows how to change the Damping
level from 0 to 2.
MAIN USER 1s
MODES SETUP SELECT
- DISPLAY
MODE
DAMPING
3s
- WIND
SPEED A. 1 A.2 SETUP + SELECT
ALARM
- RELATIVE
MODE - WIND SHIFT
- TRUE SETUP ALARM
- GEO-
- SPEED
GRAPHIC
UNIT 3s
- LIGHT
BANK
The wind shift alarm will monitor the wind angle. The
reference angle is set when the alarm is turned on,
and reset to present wind angle when an alarm is
acknowledged by a short press on one of the keys.
Range: 0 - 90° Default: 090°
MAIN USER
MODES SETUP
SELECT 3s
- DISPLAY
DAMPING
- WIND
3s SPEED
- RELATIVE
- TRUE
MODE
SETUP
ALARM
- WIND SHIFT
ALARM
A.090 SELECT
- GEO-
- SPEED
GRAPHIC
UNIT
- LIGHT
BANK
SELECT 3s
4 SELECT
1s
MODE
4 SETUP + SELECT
3s
kts
mph
km/h
BEAU
MAIN USER
MODES SETUP 1s
SELECT
- DISPLAY
DAMPING
MODE
SP 1 SP 2 SP 3 +
- WIND
3s SPEED
- RELATIVE
ALARM SETUP SELECT
MODE - WIND SHIFT
- TRUE SETUP ALARM
- GEO-
- SPEED
GRAPHIC
UNIT
- LIGHT 3s
BANK
Simrad 1
Group 1 1
Group 2 1
Group 3 1
Group 4 1
Group 5 1
Group 6 1
None 1
MODE
- RELATIVE
3s
- WIND
SPEED
ALARM SETUP + SELECT
MODE - WIND SHIFT
- TRUE SETUP ALARM
- GEO-
- SPEED
GRAPHIC
UNIT
- LIGHT
3s
BANK
- 4 screws
- 6 corners
- 1 terminal block
Spare parts | 25
Part. no. Description
SimNet cable to Micro–C male
24005729
Cable that connects a SimNet product to a
NMEA2000 network
26 | Spare parts
6 Specifications
Technical specifications
Power supply.....................................12/24V DC (+30%, -10%)
Power consumption........................................................< 5W
SimNet network load....................................................... 1 NL
Input signals:
NMEA2000/SimNet........................................ 1 can channel
NMEA0183:........................... 1 optoisolated RS485 channel
Input mode selection:...........................NMEA2000/SimNet,
NMEA0183,
Demo mode
NMEA0183 to SimNet converter:.................When NMEA0183
is selected
Weight:........................................................ 0.55 kg (1.21 lb)
Material:........................................................ ASA/PC Luran S
Color:........................................................................... Black
Display:
Dial:....................................................................0 - 359°
Marking:.....................................................................10°
Illumination:.................................... Adjustable in 10 steps
Digital display:.................................. Four 7-segment LEDs
Environmental protection:
Front........................................................................ IP66
Back:....................................................................... IP20
Safe distance to compass:
Steering compass..................................... 0.40 m (1.32 ft.)
Stand-by/Emergency distance.................... 0.20 m (0.66 ft.)
Temperature:
Operating:.............................. -15 to +70°C (+5 to +158°F)
Storage:................................-40 to +80°C (-40 to +176°F)
Climate
Max 95% RH:.................................... Max 30 days per year
Max 85% RH:............................................ Remaining days
Max 75% RH:.......................................... Average per year
Specifications | 27
Dimensional drawing
21 mm [0.83"]
47 mm [1.86"]
172 mm [6.78"]
152 mm [5.98"]
136 mm [5.35"]
136 mm [5.35"]
153 mm [6.02"]
28 | Specifications