Manual For RAMConcept To SAFE Ultility

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

5/3/2020 Update1 - RamConceptSAFEUtility - RAM | STAAD | OpenTower Files - RAM | STAAD | OpenTower - Bentley Communities

Update1 - RamConceptSAFEUtility Download

This tool have been updated with ability to bulk import load cases and point loads from excel spreadsheet into

RAM Concept.

To Start, load a sample F2k file File>Blank

Delete the tables you don't need.

Type in new form or paste (use the button in the top left of the form) from clipboard (Microsoft Excel) for Load Cases

Load Case Name - can be any string being your load case name.

https://communities.bentley.com/products/ram-staad/m/structural_analysis_and_design_gallery/273713 1/4
5/3/2020 Update1 - RamConceptSAFEUtility - RAM | STAAD | OpenTower Files - RAM | STAAD | OpenTower - Bentley Communities
Previewing
Load Case Staged
Type Changes
- have to be either "other_dead" or "live_reducible"

Next go to Point Loads Tab

Paste values from similar table in Excel (do not copy across column headers).

X - X location of point load

Y - Y location of point load

fx, fy, fz, mx, my and mz are self explanatory.

LC is the Load Case number from Load Cases Table in previous tab

For above screenshot (simple example of only 2 point loads) at location (0, 0) and (3, 3) corresponding to Load

Case No1 and No2.

Load Case No1 being the first load case entry in the previous table (DEAD_SAFE)

Load Case No2 being the second load case entry (LIVE_SAFE).

Once both Load Cases and Point Loads Bulk Entry form is completed, click "Load into Main Form" button top right

https://communities.bentley.com/products/ram-staad/m/structural_analysis_and_design_gallery/273713 2/4
5/3/2020 Update1 - RamConceptSAFEUtility - RAM | STAAD | OpenTower Files - RAM | STAAD | OpenTower - Bentley Communities

Verify your entries are now in your main form for both LoadCase and PointLoads

You can then generate your GCFF file, if error regarding "Fix Concrete"

Follow prompt to ensure Concrete table have non-zero properties, this is a prerequisite for the GCFF export

progress

Clicking all the replace buttons will ensure there are no "zero" values for concrete properties.

Once a GCFF file is created, open your existing RAM Concept file and go into Sync STAAD>Update from STAAD

GCFF File.

Select the exported GCFF File, when prompted with items to bring in, ensure to deselect all items except "Loads".

https://communities.bentley.com/products/ram-staad/m/structural_analysis_and_design_gallery/273713 3/4
5/3/2020 Update1 - RamConceptSAFEUtility - RAM | STAAD | OpenTower Files - RAM | STAAD | OpenTower - Bentley Communities

Prompted that import was successful

 Excel  RAM Concept

Wentao Zhang

 0 comments  0 members are here