Download as pdf or txt
Download as pdf or txt
You are on page 1of 36

INDEX

Sl.No. Description Page


1 BOILER EQUIPMENTS 3

2 BOILER VALVES AND DAMPERS 10

3 TURBINE EQUIPMENTS 25

4 TURBINE VALVES AND DAMPERS 31

Page 1 of 36
BOILER EQUIPMENT DETAILS

SL.NO EQUIPMENT PARTICULARS KV KW LOCATION START STOP REMARKS


FANS
1 ID FAN-1 0.69 800 BOILER RIGHT NEAR CHIMNEY
2 ID FAN-2 0.69 800 BOILER LEFT NEAR CHIMNEY
3 LOP A1-SA FAN -A 0.415 1.1 0 ML BOILER RHS AT SA FAN-A
4 LOP A2-SA FAN -A 0.415 1.1 0 ML BOILER RHS AT SA FAN-A
5 SAND FILTER BLOWER-SA FAN-A 0.415 5.5 0 ML BOILER RHS AT SA FAN-A
6 SA FAN -A 6.6 1000 0 ML BOILER RHS (CHIMNEY SIDE)
7 LOP B1-SA FAN -B 0.415 1.1 0 ML BOILER RHS AT SA FAN-B
8 LOP B2-SA FAN -B 0.415 1.1 0 ML BOILER RHS AT SA FAN-B
9 SAND FILTER BLOWER-SA FAN-B 0.415 5.5 0 ML BOILER RHS AT SA FAN-B
10 SA FAN -B 6.6 1000 0 ML BOILER RHS (UCB SIDE)
11 LOP A1-PA FAN -A 0.415 1.1 0 ML BOILER LHS AT PA FAN-A
12 LOP A2-PA FAN -A 0.415 1.1 0 ML BOILER LHS AT PA FAN-A
13 SAND FILTER BLOWER-PA FAN-A 0.415 5.5 0 ML BOILER LHS AT PA FAN-A
14 PA FAN -A 6.6 1200 0 ML BOILER LHS (CHIMNEY SIDE)
15 LOP B1-PA FAN -B 0.415 1.1 0 ML BOILER LHS AT PA FAN-B
16 LOP B2-PA FAN -B 0.415 1.1 0 ML BOILER LHS AT PA FAN-B
17 SAND FILTER BLOWER-PA FAN-B 0.415 5.5 0 ML BOILER LHS AT PA FAN-B
18 PA FAN -B 6.6 1200 0 ML BOILER LHS (UCB SIDE)
BLOWERS
19 PURGE &SEAL BLOWER-1 6.6 170 0-ML BLOWER ROOM(D row side)
20 PURGE &SEAL BLOWER-2 6.6 170 0-ML BLOWER ROOM(D row side)
21 ASH COOLER BLOWER-LEFT 6.6 170 0-ML BLOWER ROOM(D row side)

Page 2 of 36
SL.NO EQUIPMENT PARTICULARS KV KW LOCATION START STOP REMARKS
22 ASH COOLER BLOWER-RIGHT 6.6 170 0-ML BLOWER ROOM(D row side)
23 SEAL POT BLOWER-1 0.415 55 0-ML BLOWER ROOM(D row side)
24 SEAL POT BLOWER-2 0.415 55 0-ML BLOWER ROOM(D row side)
25 SEAL POT BLOWER STAND BY 0.415 55 0-ML BLOWER ROOM(D row side)
26 FBHE EMPTY CHAMBER BLOWER-1 6.6 200 0-ML BLOWER ROOM(E row side)
27 FBHE EMPTY CHAMBER BLOWER-2 6.6 200 0-ML BLOWER ROOM(E row side)
28 FBHE BUNDLE CHAMBER BLOWER-1 6.6 200 0-ML BLOWER ROOM(E row side)
29 FBHE BUNDLE CHAMBER BLOWER-3 6.6 200 0-ML BLOWER ROOM(E row side)
FBHE BUNDLE CHAMBER BLOWER-1 & 3
30 STDBY 6.6 200 0-ML BLOWER ROOM(E row side)
31 FBHE BUNDLE CHAMBER BLOWER-2 6.6 200 0-ML BLOWER ROOM(E row side)
32 FBHE BUNDLE CHAMBER BLOWER-4 6.6 200 0-ML BLOWER ROOM(E row side)
FBHE BUNDLE CHAMBER BLOWER-2 & 4
33 STDBY 6.6 200 0-ML BLOWER ROOM(E row side)
0-ML OUTSIDEBLOWER ROOM( LEFT
34 SAND FILTER BLOWER - BLOWER ROOM- LEFT 0.415 0.75 CORNER)
0-ML OUTSIDEBLOWER ROOM( RIGHT
35 SAND FILTER BLOWER - BLOWER ROOM-RIGHT 0.415 0.75 CORNER)
RALFS (ROTARY AIR LOCK FEEDERS)
36 LIGNITE FEEDER- LEFT 0.415 5.5 16 ML-COMBUSTOR LHS (ABOVE MFT)
37 LIGNITE FEEDER- RIGHT 0.415 5.5 16 ML-COMBUSTOR RHS (ABOVE MFT)
38 BED MATERIAL FEEDER -LEFT 0.415 1.1 27 ML- COMBUSTOR FRONT LEFT
39 BED MATERIAL FEEDER -RIGHT 0.415 1.1 27 ML- COMBUSTOR FRONT RIGHT
40 LIME FEEDER A1 0.415 1.5 27 ML- COMBUSTOR LEFT
41 LIME FEEDER A2 0.415 1.5 27 ML- COMBUSTOR LEFT
42 LIME FEEDER B1 0.415 1.5 27 ML- COMBUSTOR RIGHT
43 LIME FEEDER B2 0.415 1.5 27 ML- COMBUSTOR RIGHT
44 BED ASH FEEDER- LEFT 0.415 2.2 2 ML-ABOVE LEFT ISG CONVEYOR
45 BED ASH FEEDER -RIGHT 0.415 2.2 2 ML-ABOVE RIGHT ISG CONVEYOR

Page 3 of 36
SL.NO EQUIPMENT PARTICULARS KV KW LOCATION START STOP REMARKS
BED ASH
46 ISG CONVEYOR- LEFT 0.415 15 0-ML-COMBUSTOR REAR LEFT
47 ISG CONVEYOR - RIGHT 0.415 15 0-ML-COMBUSTOR REAR RIGHT
0ML- BED ASH CONTROL ROOM IN
48 BED ASH BLOWER-A 0.415 110 BETWEEN UNIT-1&2 (EBFP ROOM SIDE)
0ML- BED ASH CONTROL ROOM IN
49 BED ASH BLOWER-B 0.415 110 BETWEEN UNIT-1&2 (MIDDLE)
0ML- BED ASH CONTROL ROOM IN
50 BED ASH BLOWER-C 0.415 110 BETWEEN UNIT-1&2 (CHIMNEY SIDE)
FOPH
51 LDO PRESSURIZING PUMP -A 0.415 18.5 INSIDE FOPH (HFO PUMP SIDE)
52 LDO PRESSURIZING PUMP -B 0.415 18.5 INSIDE FOPH (MIDDLE PUMP)
53 LDO PRESSURIZING PUMP -C 0.415 18.5 INSIDE FOPH (STAIR CASE SIDE)
54 HFO PRESSURIZING PUMP-A 0.415 37 INSIDE FOPH (HEATERS SIDE)
55 HFO PRESSURIZING PUMP-B 0.415 37 INSIDE FOPH (MIDDLE PUMP)
56 HFO PRESSURIZING PUMP-C 0.415 37 INSIDE FOPH (LDO PUMPS SIDE)
57 DRAIN OIL PUMP(LDO/HFO PRESSURISING SYSTEM) 0.415 2.2 INSIDE FOPH- BELOW STAIR CASE
58 LDO UNLOADING PUMP-A 0.415 7.5 INSIDE FOPH
59 LDO UNLOADING PUMP-B (STD BY) 0.415 7.5 INSIDE FOPH
60 HFO UNLOADING PUMP-A 0.415 11 INSIDE FOPH
61 HFO UNLOADING PUMP-B (STD BY) 0.415 11 INSIDE FOPH
62 DRAIN OIL PUMP(LDO/HFO UNLOADING SYSTEM) 0.415 1.1 INSIDE FOPH
63 LDO TRANSFER PUMP FOR LIME SYSTEM-A 0.415 0.75 INSIDE FOPH
64 LDO TRANSFER PUMP FOR LIME SYSTEM-B (STD BY) 0.415 0.75 INSIDE FOPH
65 OIL WATER SUMP PUMP-A 0.415 5.5 INSIDE FOPH
66 OIL WATER SUMP PUMP-B (STD BY) 0.415 5.5 INSIDE FOPH
67 OIL WATER SEPARATOR PUMP-A 0.415 3.7 OUTSIDE FOPH-BEHIND UNLOADING BAY
68 OIL WATER SEPARATOR PUMP-B 0.415 3.7 OUTSIDE FOPH-BEHIND UNLOADING BAY
69 DRAIN OIL PUMP(BOILER) 0.415 2.2 0 ML- COMBUSTOR FRONT RHS CORNER

Page 4 of 36
SL.NO EQUIPMENT PARTICULARS KV KW LOCATION START STOP REMARKS
CHEMICAL DOZING PUMPS
70 PHOSPHATE DOZING PUMP-1 0.415 2.2 0 ML-COMBUSTOR LEFT (PO4 TANK SIDE)
71 PHOSPHATE DOZING PUMP-2 0.415 2.2 0 ML-COMBUSTOR LEFT
LIGNITE FEEDERS
72 TRANSPORT CONVEYOR-LEFT 0.415 30 18 ML-COMBUSTOR LEFT
73 TRANSPORT CONVEYOR- RIGHT 0.415 30 18 ML-COMBUSTOR RIGHT
74 EXTRACTION FEEDER -A1 0.415 15 21 ML-COMB.FRONT LEFT (UCB SIDE)
75 EXTRACTION FEEDER -A2 0.415 15 21 ML-COMB.FRONT LEFT (MIDDLE )
76 EXTRACTION FEEDR -A3 0.415 15 21 ML-COMB.FRONT LEFT (BOILER SIDE)
77 EXTRACTION FEEDR -B1 0.415 15 21 ML-COMB.FRONT RIGHT (UCB SIDE)
78 EXTRACTION FEEDR -B2 0.415 15 21 ML-COMB.FRONT RIGHT (MIDDLE)
21 ML-COMB.FRONT RIGHT (BOILER
79 EXTRACTION FEEDR -B3 0.415 15 SIDE)
FIRE HYDRANT PUMPS
80 FIRE HYDRANT BOOSTER PUMP(ELECTRICAL ) 0.415 37.5 0-ML IN FRONT OF EMERGENCY BFP
81 FIRE HYDRANT BOOSTER PUMP(DIESEL )-60 HP NA 45 0-ML IN FRONT OF EMERGENCY BFP
LIME FEEDING SYSTEM
82 VENT FILTER BLOWER-LEFT 0.415 7.5 41 ML-DRUM LEVEL-LEFT
83 VENT FILTER BLOWER-RIGHT 0.415 7.5 41 ML-DRUM LEVEL-RIGHT
LIME HANDLING SYSTEM
84 HAG OIL PUMP-A 0.415 0.55 INSIDE LIME MILLING PLANT
85 HAG OIL PUMP-B 0.415 0.55 INSIDE LIME MILLING PLANT
86 COMBUSTION AIR FAN 0.415 2.2 INSIDE LIME MILLING PLANT
87 DILUTION AIR FAN 0.415 7.5 INSIDE LIME MILLING PLANT
88 LOP MILL BEARING-321-HP1A 0.415 3.7 INSIDE LIME MILLING PLANT
89 LOP MILL BEARING-321-HP1B 0.415 3.7 INSIDE LIME MILLING PLANT
90 LOP MILL BEARING-321-LP1C 0.415 3.7 INSIDE LIME MILLING PLANT
91 LOP MILL BEARING-321-LP1D 0.415 3.7 INSIDE LIME MILLING PLANT
92 LOP MILL BEARING-322-HP2A 0.415 3.7 INSIDE LIME MILLING PLANT

Page 5 of 36
SL.NO EQUIPMENT PARTICULARS KV KW LOCATION START STOP REMARKS
93 LOP MILL BEARING-322-HP2B 0.415 3.7 INSIDE LIME MILLING PLANT
94 LOP MILL BEARING-322-LP2C 0.415 3.7 INSIDE LIME MILLING PLANT
95 LOP MILL BEARING-322-LP2D 0.415 3.7 INSIDE LIME MILLING PLANT
96 BALL MILL AUXILIARY MOTOR FOR 321 0.415 5.5 INSIDE LIME MILLING PLANT
97 BALL MILL AUXILIARY MOTOR FOR 322 0.415 5.5 INSIDE LIME MILLING PLANT
98 BALL MILL MAIN -321 6.6 200 INSIDE LIME MILLING PLANT
99 BALL MILL MAIN -322 6.6 200 INSIDE LIME MILLING PLANT
100 WEIGH FEEDER FOR 321 0.415 1.5 INSIDE LIME MILLING PLANT
101 WEIGH FEEDER FOR 322 0.415 1.5 INSIDE LIME MILLING PLANT
ROTARY AIR LOCK FEEDER BELOW
102 CYCLONE(321) 0.415 1.1 INSIDE LIME MILLING PLANT
ROTARY AIR LOCK FEEDER BELOW
103 CYCLONE(322) 0.415 1.1 INSIDE LIME MILLING PLANT
104 GRIT RETURN SCREW CONVEYOR(321) 0.415 5.5 INSIDE LIME MILLING PLANT
105 GRIT RETURN SCREW CONVEYOR(322) 0.415 5.5 INSIDE LIME MILLING PLANT
106 RALF BELOW MAIN BAG FILTER(321) 0.415 0.75 INSIDE LIME MILLING PLANT
107 RALF BELOW MAIN BAG FILTER(322) 0.415 0.75 INSIDE LIME MILLING PLANT
108 BACK FILTER RETURN SCREW CONVEYOR(321) 0.415 1.5 INSIDE LIME MILLING PLANT ABB
109 BACK FILTER RETURN SCREW CONVEYOR(322) 0.415 1.5 INSIDE LIME MILLING PLANT CG
INST.BAG FILTER FAN FOR PRODUCTION
110 BIN(321) 0.415 1.1 INSIDE LIME MILLING PLANT
INST.BAG FILTER FAN FOR PRODUCTION
111 BIN(322) 0.415 1.1 INSIDE LIME MILLING PLANT
112 ID FAN-1(321) 0.415 110 INSIDE LIME MILLING PLANT
113 ID FAN-2(322) 0.415 110 INSIDE LIME MILLING PLANT
114 FAN FOR CONVEYOR ENCLOSURE(BLOWER) 0.415 7.5 NEAR LIME LOADING POINT
115 EXHAUST FAN FOR CONVEYOR ENCLOSURE 0.415 7.5 NEAR LIME LOADING POINT
116 DENSE PHASE CONV.COMPRESSOR-1 6.6 315 IN COMPRESSOR ROOM OF LIME PLANT
117 DENSE PHASE CONV.COMPRESSOR-2 6.6 315 IN COMPRESSOR ROOM OF LIME PLANT
118 AIR COMP.INST&PURGE AIR-1 COMPRESSOR-1 0.415 37 IN COMPRESSOR ROOM OF LIME PLANT

Page 6 of 36
SL.NO EQUIPMENT PARTICULARS KV KW LOCATION START STOP REMARKS
119 AIR COMP.INST&PURGE AIR-1 COMPRESSOR-2 0.415 37 IN COMPRESSOR ROOM OF LIME PLANT
120 AIR DRYER-A 0.415 5.5 IN COMPRESSOR ROOM OF LIME PLANT
121 AIR DRYER-B 0.415 5.5 IN COMPRESSOR ROOM OF LIME PLANT
122 FRESH AIR BLOWER(L) IN MCC ROOM 0.415 1.5 INSIDE MCC ROOM
123 FRESH AIR BLOWER(R) IN MCC ROOM 0.415 1.5 INSIDE MCC ROOM

Page 7 of 36
STATION LAYOUT

Page 8 of 36
NLC-BTPP-2X125 MW-CFBC BOILERS-VALVES & DAMPERS LOCATION

Sl.no VALVE NO DESCRIPTION TYPE LOCATION OPEN CLOSE REMARKS


FEED WATER SYSTEM
1 FD19 FEED CONTROL STATION(FL) I/LVALVE MOV 18 ML- NEARRIGHT SIDE TRANSPORT FEEDER
2 FD19A FEED CONTROL STATION(FL) I/L CHARGING MOV 18 ML- NEAR RIGHT SIDE TRANSPORT FEEDER
VALVE
3 FD 20 FEED CONTROL STATION(FL) CONTROL VALVE PNEU 18 ML- NEARRIGHT SIDE TRANSPORT FEEDER
4 FD21 FEED CONTROL STATION(FL) O/L VALVE MOV 18 ML- NEARRIGHT SIDE TRANSPORT FEEDER
5 FD21A FEED CONTROL STATION(FL) O/L CHARGING MOV 18 ML- NEARRIGHT SIDE TRANSPORT FEEDER
VALVE
6 FD22 FEED CONTROL STATION(FL) I/LVALVE MOV 18 ML- RIGHT SIDE TRANSPORT FEEDER (RIGHT ROW)
7 FD22A FEED CONTROL STATION(FL) I/L CHARGING MOV 18 ML- RIGHT SIDE TRANSPORT FEEDER (RIGHT ROW)
VALVE
8 FD 23 FEED CONTROL STATION(FL) CONTROL VALVE PNEU 18 ML- RIGHT SIDE TRANSPORT FEEDER (RIGHT ROW)
9 FD24 FEED CONTROL STATION(FL) O/L VALVE MOV 18 ML- RIGHT SIDE TRANSPORT FEEDER (RIGHT ROW)
10 FD24A FEED CONTROL STATION(FL) O/L CHARGING MOV 18 ML- RIGHT SIDE TRANSPORT FEEDER (RIGHT ROW)
VALVE
11 FD25 FEED CONTROL STATION(LL) I/LVALVE MOV 18 ML- RIGHT SIDE TRANSPORT FEEDER NEAR LT AST HEADER
( MIDDLE ROW)
12 FD25A FEED CONTROL STATION(LL) I/L CHARGING MOV 18 ML- RIGHT SIDE TRANSPORT FEEDER NEAR LT AST HEADER
VALVE ( MIDDLE ROW)
13 FD 26 FEED CONTROL STATION(LL) CONTROL VALVE PNEU 18 ML- RIGHT SIDE TRANSPORT FEEDER NEAR LT AST HEADER
( MIDDLE ROW)
14 FD27 FEED CONTROL STATION(LL) O/L VALVE MOV 18 ML- RIGHT SIDE TRANSPORT FEEDER NEAR LT AST HEADER
( MIDDLE ROW)
15 FD27A FEED CONTROL STATION(LL) O/L CHARGING MOV 18 ML- RIGHT SIDE TRANSPORT FEEDER NEAR LT AST HEADER
VALVE ( MIDDLE ROW)
16 FW 004 ECO.FEED PIPE MAIN ISO .VLV MOV 10.5 ML-COMBUSTOR REAR SIDE NEAR RH SPRAY STATION

17 FW 004A ECO.FEED PIPE MAIN ISO INTEGRAL MOV 10.5 ML-COMBUSTOR REAR SIDE NEAR RH SPRAY STATION
BYPASS VLV
18 FW 019 ECO R/C VALVE MOV 4 ML- NEAR RIGHT SIDE BIG DOWN COMER FOR UNIT-1
4 ML- BELOW RIGHT SIDE ASH COOLER FOR UNIT-2

Page 9 of 36
Sl.no VALVE NO DESCRIPTION TYPE LOCATION OPEN CLOSE REMARKS
19 BW 59 DRUM CBD LINE MAIN CONTROL VALVE MOV 39 ML- COMBUSTOR RIGHT SIDE JUST BELOW DRUM LEVEL

20 BW60 DRUM CBD LINE (B/P)BLOW DOWN MOV 39 ML- COMBUSTOR RIGHT SIDE JUST BELOW DRUM LEVEL
VALVE
21 BW54 DRUM EMERGENCY DRAIN TO IBD ISO MOV 41 ML- COMBUSTOR FRONT LEFT CORNER ( DRUM LEVEL)
22 BW 55 DRUM EMERGENCY DRAIN TO IBD MOV 41 ML- COMBUSTOR FRONT LEFT CORNER ( DRUM LEVEL)
CONTROL
SPRAY WATER SYSTEM
23 SW 091 SH DESH1 MAIN SPRAY LINE ISO .VALVE MOV 29 ML- BACK PASS RIGHT SIDE
24 SW 001 SH DESH1 SPRAY LINE MAINQUICK SOV 29 ML- BACK PASS RIGHT SIDE
CLOSING VALVE
25 SW 013 SH DESH1 SPRAY MAIN LINE INLET ISO MOV 29 ML- BACK PASS RIGHT SIDE
.VALVE
26 SW 016 SH DESH1 SPRAY MAIN LINE CONTROL PNEU 29 ML- BACK PASS RIGHT SIDE
.VALVE
27 SW 019 SH DESH1 SPRAY BYPASS LINE INLET ISO MOV 29 ML- BACK PASS RIGHT SIDE
.VALVE
28 SW 022 SH DESH1 SPRAY B/P LINE CONTROL PNEU 29 ML- BACK PASS RIGHT SIDE
MAIN VALVE
29 SW 092 SH DESH2 SPRAY LINE MAIN ISO MOV 32 ML- BACK PASS LEFT SIDE
.VALVE
30 SW 031 SH DESH2 SPRAY LINE MAIN QICK SOV 32 ML- BACK PASS LEFT SIDE
CLOSING VALVE
31 SW 043 SH DESH2 SPRAY MAIN LINE INLET ISO MOV 32 ML- BACK PASS LEFT SIDE
.VALVE
32 SW 046 SH DESH 2 SPRAY MAIN LINE CONTROL PNEU 32 ML- BACK PASS LEFT SIDE
VALVE
33 SW 049 SH DESH 2 SPRAY BYPASS LINE INLET MOV 32 ML- BACK PASS LEFT SIDE
ISO .VALVE
34 SW 052 SH DESH2 SPRAY B/P LINE CONTROL PNEU 32 ML- BACK PASS LEFT SIDE
VALVE
35 SW 093 RH DESH SPRAY LINE MAIN ISO .VALVE MOV 10.5 ML-BACK PASS RIGHT SIDE
36 SW 061 RH DESH SPRAY LINE MAIN QICK SOV 10.5 ML-BACK PASS RIGHT SIDE
CLOSING VALVE
37 SW 073 RH DESH SPRAY MAIN LINE INLET ISO MOV 10.5 ML-BACK PASS RIGHT SIDE
.VALVE
38 SW 076 RH DESH SPRAY MAIN LINE CONTROL PNEU 10.5 ML-BACK PASS RIGHT SIDE
VALVE

Page 10 of 36
Sl.no VALVE NO DESCRIPTION TYPE LOCATION OPEN CLOSE REMARKS
39 SW 079 RH DESH SPRAY BYPASS LINE INLET ISO MOV 10.5 ML-BACK PASS RIGHT SIDE
.VALVE
40 SW 082 RH DESH SPRAY B/P LINE CONTROL PNEU 10.5 ML-BACK PASS RIGHT SIDE
VALVE

STEAM SYSTEM
41 BW 36 DRUM VENT-ISO.VALVE MOV 45 ML- COMBUSTOR FRONT LEFT CORNER( JUST ABOVE
DRUM)
42 BW 37 DRUM VENT-REG.VALVE MOV 45 ML- COMBUSTOR FRONT LEFT CORNER( JUST ABOVE
DRUM)
43 MS 006 SATURATED SEAM AIR VENT MOV 45 ML- COMBUSTOR FRONT LEFT CORNER( JUST ABOVE
DRUM)
44 MS 007 SATURATED SEAM AIR VENT MOV 45 ML- COMBUSTOR FRONT LEFT CORNER( JUST ABOVE
DRUM)
45 MS 101 MS LINE START UP VENT ISO .VALVE MOV 40 ML-COMBUSTOR RIGHT SIDE BELOW BACK PASS I/L DUCT-
(BOILER SIDE)
46 MS 102 MS LINE START UP VENT REG VALVE MOV 40 ML-COMBUSTOR RIGHT SIDE BELOW BACK PASS I/L DUCT
( BOILER SIDE)
47 MS 103 MS LINE START UP VENT ISO .VALVE MOV 40 ML-COMBUSTOR RIGHT SIDE BELOW BACK PASS I/L DUCT
( MSV SIDE)
48 MS 104 MS LINE START UP VENT REG VALVE MOV 40 ML-COMBUSTOR RIGHT SIDE BELOW BACK PASS I/L DUCT
(MSV SIDE)
49 MS 107 MAIN STEAM STOP VALVE MOV 36 ML- BELOW BACK PASS I/L FG DUCT
50 MS 107A MAIN STEAM STOP VALVE-CHARGING MOV 36 ML- BELOW BACK PASS I/L FG DUCT
VALVE
51 MS 151 MAIN STEAM STOP VALVE-B/P VALVE MOV 36 ML- BELOW BACK PASS I/L FG DUCT
52 MS 85 RH START UP VENT ISO .VALVE MOV 47 ML-BACK PASS REAR RIGHT CORNER
53 MS 86 RH START UP VENT REG VALVE MOV 47 ML-BACK PASS REAR RIGHT CORNER
AUX. STEAM SYSTEM (APRDS)
54 AS 21 HC PRDS I/L ISO LATION VALVE MOV 15 ML APRDS ROOM-BEHIND RIGHT SIDE TRANSPORT
FEEDER TAIL END.(C-ROW SIDE)
55 AS 21A HC PRDS I/L ISOLATION B/P VALVE MOV 15 ML APRDS ROOM-BEHIND RIGHT SIDE TRANSPORT
FEEDER TAIL END.(C-ROW SIDE)
56 AS 22 HC PRDS PRESSURE CONTROL VALVE PNEU 15 ML APRDS ROOM-BEHIND RIGHT SIDE TRANSPORT
FEEDER TAIL END.(C-ROW SIDE)
57 AS 24 HC PRDS B/P LINE I/L VALVE MOV 15 ML APRDS ROOM-BEHIND RIGHT SIDE TRANSPORT
FEEDER TAIL END.(C-ROW SIDE)

Page 11 of 36
Sl.no VALVE NO DESCRIPTION TYPE LOCATION OPEN CLOSE REMARKS
58 AS 24A HC PRDS B/P LINE I/L B/P VALVE MOV 15 ML APRDS ROOM-BEHIND RIGHT SIDE TRANSPORT
FEEDER TAIL END.(C-ROW SIDE)
59 AS 25 HC PRDS B/P LINE CONTROL VALVE MOV 15 ML APRDS ROOM-BEHIND RIGHT SIDE TRANSPORT
FEEDER TAIL END.(C-ROW SIDE)
60 AS 151 MS TO HC PRDS LINE DRN VLV MOV 15 ML APRDS ROOM-(C-ROW SIDE)
61 AS 30 LC PRDS I/L ISOLATION VALVE MOV 15 ML APRDS ROOM-(B-ROW SIDE)
62 AS 31 LC PRDS CONTROL VALVE PNEU 15 ML APRDS ROOM-(B-ROW SIDE)
63 AS 33 LC PRDS B/P LINE I/L ISO.VALVE MOV 15 ML APRDS ROOM-(B-ROW SIDE)
64 AS 34 LC PRDS B/P LINE CONTROL VALVE MOV 15 ML APRDS ROOM-(B-ROW SIDE)
65 AS 155 CRH TO LC PRDS LINE DRN VLV MOV 15 ML APRDS ROOM-(B-ROW SIDE)
66 AS 53 HT-AST INTER CONNECTION VALVE MOV 15 ML APRDS ROOM-(B-ROW SIDE)
67 AS 46 LT –AST INTER CONNECTION VALVE MOV 18 ML -BEHIND FEED CONTROL STATION IN LT –AST HEADER
FOR UNIT-1. (FOR UNIT-2 ABOVE AS 46 OF UNIT-1)
68 FD 43 HC PRDS SPRAY MAIN LINE I/L VALVE MOV 15 ML APRDS ROOM-(C-ROW SIDE)
69 FD 44 HC PRDS SPRAY MAIN LINE PRESSURE PNEU 15 ML APRDS ROOM-(C-ROW SIDE)
CONTROL VALVE (PCV)
70 FD 45 HC PRDS SPRAY MAIN LINE TEMP. PNEU 15 ML APRDS ROOM-(C-ROW SIDE)
CONTROL VALVE (TCV)
71 FD 48 HC PRDS SPRAY B/P LINE I/L VALVE MOV 15 ML APRDS ROOM-(C-ROW SIDE)
72 FD 49 HC PRDS SPRAY B/P LINE PRESSURE MOV 15 ML APRDS ROOM-(C-ROW SIDE)
CONTROL VALVE (PCV)
73 FD 50 HC PRDS SPRAY B/P LINE MOV 15 ML APRDS ROOM-(C-ROW SIDE)
TEMP.CONTROL VALVE(TCV)
74 FD 52 LC PRDS SPRAY MAIN LINE I/L VALVE MOV 15 ML APRDS ROOM-(B-ROW SIDE)
75 FD 53 LC PRDS SPRAY MAIN LINE PRESSURE PNEU 15 ML APRDS ROOM-(B-ROW SIDE)
CONTROL VALVE (PCV)
76 FD 54 LC PRDS SPRAY MAIN LINE TEMP. PNEU 15 ML APRDS ROOM-(B-ROW SIDE)
CONTROL VALVE (TCV)
77 FD 57 LC PRDS SPRAY B/P LINE I/L VALVE MOV 15 ML APRDS ROOM-(B-ROW SIDE)
78 FD 58 LC PRDS SPRAY B/P LINE PRESSURE MOV 15 ML APRDS ROOM-(B-ROW SIDE)
CONTROL VALVE(PCV)
79 FD 59 LC PRDS SPRAY B/P LINE MOV 15 ML APRDS ROOM-(B-ROW SIDE)
TEMP.CONTROL VALVE(TCV)
80 FD 63 PRDS SPRAY MAIN LINE BLOCK VALVE PNEU 15 ML APRDS ROOM- BELOW STAIR CASE

Page 12 of 36
Sl.no VALVE NO DESCRIPTION TYPE LOCATION OPEN CLOSE REMARKS
DRAINS SYSTEM
81 BW 141 DRUM DRAIN-1ST VALVE MOV 41 ML- DRUMLEVEL-LEFT SIDE
82 BW 142 DRUM DRAIN-2 nd VALVE MOV 41 ML- DRUMLEVEL-LEFT SIDE
83 MS 156 BEF. MS STOP VALVE DRAIN VALVE MOV 6.5 ML –COMBUSTOR RIGHT SIDE
ND
84 MS 005 DRUM COLLEC. HDR O/L LINK DRAIN MOV 0 ML-SH DRAIN HEADER -2 LINE FROM LEFT TOP
RD
85 MS 009 BACKPASS BOTTOM RING HDR DRAIN MOV 0 ML-SH DRAIN HEADER -3 LINE FROM LEFT TOP
RD
86 MS 016 SH-1B I/L HDR DRAIN MOV 0 ML-SH DRAIN HEADER 3 LINE FROM LEFT BOTTOM
ND
87 MS 018 SH-1BO/L HDR DRAIN MOV 0 ML-SH DRAIN HEADER 2 LINE FROM LEFT BOTTOM
ST
88 MS 020 DESH-1 I/L HDR DRAIN MOV 0 ML-SH DRAIN HEADER 1 LINE FROM RIGHT BOTTOM
ND
89 MS 030 SH-2A I/L HDR DRAIN MOV 0 ML-SH DRAIN HEADER 2 LINE FROM RIGHT BOTTOM
ND
90 MS 032 SH-2A O/L HDR DRAIN MOV 0 ML-SH DRAIN HEADER – 2 LINE FROM RIGHT TOP
RD
91 MS 036 SH-2B I/L HDR DRAIN MOV 0 ML-SH DRAIN HEADER- 3 LINE FROM RIGHT TOP
ST
92 MS 038 SH-2B O/L HDR DRAIN MOV 0 ML-SH DRAIN HEADER- 1 LINE FROM RIGHT TOP
TH
93 MS 050 SH3 O/L HDR DRAIN MOV 0 ML-SH DRAIN HEADER 4 LINE FROM LEFT TOP
ND
94 MS 057 RH1 I/L HDR DRAIN MOV 0 ML-RH DRAIN HEADER -2 LINE FROM RIGHT TOP
ST
95 MS 059 RH1 O/L HDR DRAIN MOV 0 ML-RH DRAIN HEADER -1 LINE FROM LEFT TOP Valve to be
erected at site
ND
96 MS 071 RH2 O/L HDR DRAIN MOV 0 ML-RH DRAIN HEADER -2 LINE FROM LEFT TOP
AIR & FLUE GAS SYSTEM
97 PA FAN -1 O/L DAMPER MOD 10.5 ML- LEFT SIDE OF AIR PRE HEATER
98 PA FAN -2 O/L DAMPER MOD 10.5 ML- LEFT SIDE OF AIR PRE HEATER
99 PA APH B/P DAMPER MOD 10.5 ML- LEFT SIDE OF BACK PASS
100 SA FAN -1 O/L DAMPER MOD 10.5 ML- RIGHT SIDE OF AIR PRE HEATER
101 SA FAN -2 O/L DAMPER MOD 10.5 ML- RIGHT SIDE OF AIR PRE HEATER
102 SA APH B/P DAMPER MOD 28 ML- NEAR SSB-32-TAPH RIGHT SIDE
103 ID FAN -1 I/L GATE MOD 22 ML- RIGHT ESP OUTLET
104 ID FAN -1 O/L GATE MOD 19.5 ML-ID DISCHARGE DUCT FOR UNIT-1
4 ML- ID DISCHARGE DUCT FOR UNIT-2
105 ID FAN -2 I/L GATE MOD 22 ML- LEFT ESP OUTLET
106 ID FAN -2 O/L GATE MOD 4 ML-ID DISCHARGE DUCT FOR UNIT-1
19.5 ML- ID DISCHARGE DUCT FOR UNIT-2

Page 13 of 36
Sl.no VALVE NO DESCRIPTION TYPE LOCATION OPEN CLOSE REMARKS
107 ESP B I/L GATE MOD 22 ML- RIGHT ESP FRONT SIDE
108 ESP B O/L GATE MOD 22 ML- RIGHT ESP REAR SIDE
109 ESP A I/L GATE MOD 22 ML- LEFT ESP FRONT SIDE
110 ESP A O/L GATE MOD 22 ML- LEFT ESP REAR SIDE
111 PA -1 IGV (CHIMINEY SIDE FAN) PNEU 0 ML- BOILER LEFT SIDE
112 PA -2 IGV ( BOILER SIDE FAN) PNEU 0 ML - BOILER LEFT SIDE
113 SA -1 IGV (CHIMINEY SIDE FAN) PNEU 0 ML- BOILER RIGHT SIDE
114 SA -2 IGV ( BOILER SIDE FAN) PNEU 0 ML- BOILER RIGHT SIDE
115 ID -1 IGV (BOILER RIGHT) PNEU 0 ML ID FAN PLAT FORM(REAR SIDE)
116 ID -2 IGV (BOILER LEFT) PNEU 0 ML ID FAN PLAT FORM (REAR SIDE)
117 SUB-1 SEC. AIR DAMPER PNEU 21 ML- COMB. FRONT (EXTR. FEEDER LEVEL)
118 SUB-2 SEC. AIR DAMPER PNEU 15 ML- COMBUSTOR REAR SIDE (MFT LEVEL)
119 COMB. UPPER SEC. AIR DAMPER PNEU 19 ML- COMBUSTOR REAR RIGHT ( AT SSB-19)
BLOWERS SYSTEM
120 EC BLOWER 1 O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-E ROW SIDE
121 EC BLOWER 2 O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-E ROW SIDE
122 FBHE BLOWER 1 O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-E ROW SIDE
123 FBHE BLOWER 3 O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-E ROW SIDE
124 FBHE 1&3 STDBY BLOWER O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-E ROW SIDE
BLOWER-I SIDE
125 FBHE 1&3 STDBY BLOWER O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-E ROW SIDE
BLOWER -3 SIDE
126 FBHE BLOWER 2 O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-E ROW SIDE
127 FBHE BLOWER 4 O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-E ROW SIDE
128 FBHE 2&4 STDBY BLOWER O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-E ROW SIDE
BLOWER -2 SIDE
129 FBHE 2&4 STDBY BLOWER O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-E ROW SIDE
BLOWER -4 SIDE
130 SEAL POT BLOWER 1 O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-D ROW SIDE
131 SEAL POT BLOWER 2 O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-D ROW SIDE
132 SEAL POT STDBY BLOWER O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-D ROW SIDE
BLOWER -1 SIDE

Page 14 of 36
Sl.no VALVE NO DESCRIPTION TYPE LOCATION OPEN CLOSE REMARKS
133 SEAL POT STDBY BLOWER O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-D ROW SIDE
BLOWER -2 SIDE
134 ASH COOLER BLOWER 1 O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-D ROW SIDE
135 ASH COOLER BLOWER 2 O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-D ROW SIDE
136 ASH COOLER BLOWERS 1&2 PNEU 0 ML-OUTSIDE BLOWER ROOM-D ROW SIDE
INTER CONNECTION GATE
137 P& S BLOWER 1 O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-D ROW SIDE
138 P& S BLOWER 2 O/L GATE PNEU 0 ML-OUTSIDE BLOWER ROOM-D ROW SIDE
LIGNITE FIRING SYSTEM
139 COMBUSTOR SPIESS VALVE-1 MOV 6.5 ML-COMBUSTOR REAR RIGHT SIDE
140 COMBUSTOR SPIESS VALVE-2 MOV 6.5 ML-COMBUSTOR REAR LEFT SIDE
141 COMBUSTOR FBHE-2 SPIESS VALVE MOV 6.5 ML-COMBUSTOR REAR LEFT CORNER SIDE
142 FBHE -1 SPIESS VALVE MOV 10.5 ML-COMBUSTOR REAR RIGHT CORNER
143 FBHE -2 SPIESS VALVE MOV 10.5 ML-COMBUSTOR REAR LEFT CORNER
144 FBHE -3 SPIESS VALVE MOV 10.5 ML-COMBUSTOR FRONT RIGHT CORNER
145 FBHE -4 SPIESS VALVE MOV 10.5 ML-COMBUSTOR FRONT LEFT CORNER
146 MFT-LEFT MOD 15 ML-COMBUSTOR LEFT SIDE
147 MFT- RIGHT MOD 15 ML-COMBUSTOR RIGHT SIDE
OIL FIRING SYSTEM
148 SUC. COIL HEATER-TCV-HFO TANKK-1 PNEU LEFT FRONT SIDE OF HFO TANK-1
149 FLR. COIL HEATER-TCV- HFO TANK-1 PNEU LEFT REAR SIDE OF HFO TANK-1
150 SUC. COIL HEATER-TCV- HFO TANK-2 PNEU LEFT FRONT SIDE OF HFO TANK-2
151 FLR. COIL HEATER-TCV- HFO TANK-2 PNEU LEFT REAR SIDE OF HFO TANK-2
152 TRACE HEATING STEAM PCV PNEU INSIDE FOPH-NEAR LIME SYSTEM PUMPS
153 LDO RET PCV 1 LDO PCV FOR UNIT-1(R/C VALVE) PNEU HFO SUCTION FILTER SIDE
154 LDO RET PCV 2 LDO PCV FOR UNIT-2(R/C VALVE) PNEU LDO FILTER SIDE
155 HFO RET PCV 1 HFO PCV FOR UNIT-1(R/C VALVE) PNEU HFO SUCTION FILTER SIDE
156 HFO RET PCV 2 HFO PCV FOR UNIT-2(R/C VALVE) PNEU HFO HEATERS SIDE
157 HTG STM TCV1 HFO TCV –HEATER NO-1 PNEU INSIDE FUEL OIL PUMP HOUSE - MCC SIDE HEATER
158 HTG STM TCV2 HFO TCV –HEATER NO.2 PNEU INSIDE FUEL OIL PUMP HOUSE- MIDDLE HEATER
159 HTG STM TCV3 HFO TCV – HEATER NO.3 PNEU INSIDE FUEL OIL PUMP HOUSE - FILTER SIDE HEATER

Page 15 of 36
Sl.no VALVE NO DESCRIPTION TYPE LOCATION OPEN CLOSE REMARKS
160 LPG MTV PILOT GAS MTV PNEU 0 MLBOILER LEFT –LPG STATION
161 LPG VENT VLV PILOT GAS VENT VALVE PNEU 0 ML – RIGHT SIDE OF LPG STATION
162 LPG BTV-1 PILOT GAS BTV FOR SUB-1 PNEU 10.5 ML-LPG I/L LINE TO SUB-1(COMB.FRONT)
163 LPG BTV-2 PILOT GAS BTV FOR SUB-2 PNEU 10.5 ML-LPG I/L LINE TO SUB-2(COMB.REAR)
164 LDO MTV LDO MTV PNEU 10.5 ML-LDO I/L LINE AT COMB.FRONT LEFT
165 LDO CV LDO FCV PNEU 10.5 ML-LDO I/L LINE AT COMB.FRONT LEFT
166 LDO BTV-1 LDO- SUB1-BTV PNEU 10.5 ML-LDO I/L LINE TO SUB-1(COMB.FRONT
167 LDO BTV-2 LDO- SUB2-BTV PNEU 10.5 ML-LDO I/L LINE TO SUB-2(COMB.REAR)
168 ATM. AIR CV ATOMISING AIR PCV PNEU 10.5 ML- ATOMISING AIR I/L LINE AT COMBUSTOR FRONT
RIGHT
169 ATM. AIR TV-1 ATOMISING AIR – SUB 1-BTV PNEU 10.5 ML- ATOMISING AIR I/L LINE TO SUB-1 AT
COMBUSTOR FRONT SIDE
170 ATM. AIR TV-2 ATOMISING AIR- SUB 2-BTV PNEU 10.5 ML- ATOMISING AIR I/L LINE TO SUB-2 AT
COMBUSTOR REAR SIDE
171 OS 36 SCAVENGING VALVE – SUB 1 PNEU 10.5 ML- ATOMISING TO OIL LINE CONNECTION
IN SUB-1 AT COMBUSTOR FRONT
172 OS 36 SCAVENGING VALVE – SUB 2 PNEU 10.5 ML- ATOMISING TO OIL LINE CONNECTION
IN SUB-2 AT COMBUSTOR REAR
173 HO 30 HFO MTV PNEU 10.5 ML-HFO I/L LINE AT COMBUSTOR FRONT
174 HO 8 HFO FCV( SUB) PNEU 10.5 ML-HFO I/L LINE AT COMBUSTOR FRONT
175 HO-R/C VLV HFO LONG R/C VALVE PNEU 10.5 ML- HFO RETURN LINE AT COMB. FRONT
176 HO 35 HFO- SUB1-BTV PNEU 10.5 ML-HFO I/L LINE TO SUB-1(COMB.FRONT)
177 HO 35 HFO- SUB2-BTV PNEU 10.5 ML-HFO I/L LINE TO SUB-2 (COMB.REAR)
178 AA 22 ATOMISING STEAM PCV PNEU 10.5 ML- ATOMISING STEAM I/L LINE AT COMB.FRONT
RIGHT
179 OS 34 ATOMISING STEAM – SUB 1-BTV PNEU 10.5 ML- ATOMISING STEAM I/L LINE TO SUB-1 AT
COMBUSTOR FRONT SIDE
180 OS 34 ATOMISING STEAM - SUB 2-BTV PNEU 10.5 ML- ATOMISING STEAM I/L LINE TO SUB-2 AT
COMBUSTOR REAR SIDE
181 HO-53 RECIRCULATION VALVE FOR SUB PNEU 10.5 ML-HFO I/L LINE TO SUB-1 NEAR BTV
1(LONG)
182 HO-53 RECIRCULATION VALVE FOR SUB 2 PNEU 10.5 ML-HFO I/L LINE TO SUB-2 NEAR BTV
(LONG)
183 HO 46 BED LANCE COMMON FCV(HFO) PNEU 6.5 ML- HFO I/L LINE AT COMB. REAR SIDE
184 BED LANCE ATOMISING STEAM PCV PNEU 6.5 ML- AT COMBUSTOR REAR SIDE-LEFT

Page 16 of 36
Sl.no VALVE NO DESCRIPTION TYPE LOCATION OPEN CLOSE REMARKS
185 FOTV LANCE-1 BED LANCE -1 BTV(HFO) PNEU 6.5 ML- HFO I/L LINE AT BED LANCE -1 (COMBUSTOR FRONT
SIDE)-LEFT
186 STM VLV BED LANCE-1 BTV ( ATOMISING STEAM) PNEU 6.5 ML- ATOMISING STEAM I/L LINE AT BED LANCE -1
(COMBUSTOR FRONT SIDE)-LEFT
187 SCVG BED LANCE-1 BTV ( CLEANING STEAM) PNEU 6.5 ML- STEAM I/L LINE TO CONNECTING OIL LINE AT BED
LANCE -1 (COMBUSTOR FRONT SIDE)-LEFT
188 BED LANCE-1 ATOMISING STEAM LINE SOV 6.5 ML AT BED LANCE -1
COOLING AIR VALVE
189 BED LANCE-1 OIL LINE COOLING AIR SOV 6.5 ML AT BED LANCE -1
VALVE
190 FOTV LANCE-2 BED LANCE -2 BTV(HFO) PNEU 6.5 ML- HFO I/L LINE AT BED LANCE -2 (COMBUSTOR FRONT
SIDE)-MIDDLE
191 STM VLV BED LANCE-2 BTV ( ATOMISING STEAM) PNEU 6.5 ML- ATOMISING STEAM I/L LINE AT BED LANCE -2
(COMBUSTOR FRONT SIDE)-MIDDLE
192 SCVG BED LANCE-2 BTV ( CLEANING STEAM) PNEU 6.5 ML- STEAM I/L TO CONNECTING OIL LINE AT BED LANCE
-2 (COMBUSTOR FRONT SIDE)-MIDDLE
193 BED LANCE-2 ATOMISING STEAM LINE SOV 6.5 ML AT BED LANCE -2
COOLING AIR VALVE
194 BED LANCE- 2 OIL LINE COOLING AIR SOV 6.5 ML AT BED LANCE -2
VALVE
195 FOTV LANCE-3 BED LANCE -3 BTV(HFO) PNEU 6.5 ML- HFO I/L LINE AT BED LANCE -3 (COMBUSTOR FRONT
SIDE)-RIGHT
196 STM VLV BED LANCE-3 BTV ( ATOMISING STEAM) PNEU 6.5 ML- ATOMISING STEAM I/L LINE AT BED LANCE -3
(COMBUSTOR FRONT SIDE)-RIGHT
197 SCVG BED LANCE-3 BTV ( CLEANING STEAM) PNEU 6.5 ML- STEAM I/L TO CONNECTING OIL LINE AT BED LANCE
-3 (COMBUSTOR FRONT SIDE)-RIGHT
198 BED LANCE- 3 ATOMISING STEAM LINE SOV 6.5 ML AT BED LANCE -3
COOLING AIR VALVE
199 BED LANCE- 3 OIL LINE COOLING AIR SOV 6.5 ML AT BED LANCE -3
VALVE
200 FOTV LANCE-4 BED LANCE -4 BTV(HFO) PNEU 6.5 ML- HFO I/L LINE AT BED LANCE -4 (COMBUSTOR REAR
SIDE)-LEFT
201 STM VLV BED LANCE- 4 BTV ( ATOMISING STEAM) PNEU 6.5 ML- ATOMISING STEAM I/L LINE AT BED LANCE -4
(COMBUSTOR REAR SIDE)-LEFT
202 SCVG BED LANCE-4 BTV ( CLEANING STEAM) PNEU 6.5 ML- STEAM I/L TO CONNECTING OIL LINE AT BED LANCE
-4 (COMBUSTOR REAR SIDE)-LEFT
203 BED LANCE- 4 AT.STEAM LINE COOLING SOV 6.5 ML AT BED LANCE -4
AIR VALVE
204 BED LANCE- 4 OIL LINE COOLING AIR SOV 6.5 ML AT BED LANCE -4
VALVE

Page 17 of 36
Sl.no VALVE NO DESCRIPTION TYPE LOCATION OPEN CLOSE REMARKS
205 FOTV LANCE-5 BED LANCE -5 BTV(HFO) PNEU 6.5 ML- HFO I/L LINE AT BED LANCE -5 (COMBUSTOR REAR
SIDE)-MIDDLE
206 STM VLV BED LANCE-5 BTV ( ATOMISING STEAM) PNEU 6.5 ML- ATOMISING STEAM I/L LINE AT BED LANCE -5
(COMBUSTOR REAR SIDE)-MIDDLE
207 SCVG BED LANCE- 5 BTV ( CLEANING STEAM) PNEU 6.5 ML- STEAM I/L TO CONNECTING OIL LINE AT BED LANCE
-5 (COMBUSTOR REAR SIDE)-MIDDLE
208 BED LANCE-5 AT.STEAM LINE COOLING SOV 6.5 ML AT BED LANCE -5
AIR VALVE
209 BED LANCE- 5 OIL LINE COOLING AIR SOV 6.5 ML AT BED LANCE -5
VALVE
210 FOTV LANCE-6 BED LANCE -6 BTV(HFO) PNEU 6.5 ML- HFO I/L LINE AT BED LANCE -6 (COMBUSTOR REAR
SIDE)-RIGHT
211 STM VLV BED LANCE-6 BTV ( ATOMISING STEAM) PNEU 6.5 ML- ATOMISING STEAM I/L LINE AT BED LANCE -6
(COMBUSTOR REAR SIDE)-RIGHT
212 SCVG BED LANCE-6 BTV ( CLEANING STEAM) PNEU 6.5 ML- STEAM I/L TO CONNECTING OIL LINE AT BED LANCE
-6 (COMBUSTOR REAR SIDE)-RIGHT
213 BED LANCE-6 ATOMISING STEAM LINE SOV 6.5 ML AT BED LANCE -6
COOLING AIR VALVE
214 BED LANCE- 6 OIL LINE COOLING AIR SOV 6.5 ML AT BED LANCE -6
VALVE
STEAM SOOT BLOWERS SYSTEM
215 PRSB 10 SSB MAIN ISO.VALVE FROM RH-1 O/L MOV 30 ML-COMBUSTOR REAR RIGHT CORNER
216 PRSB 006 SSB MAIN LINE STEAM PCV PNEU 30 ML-COMBUSTOR REAR RIGHT CORNER
217 PRSB 003 SSB B/P LINE STEAM PCV PNEU 30 ML-COMBUSTOR REAR RIGHT CORNER
218 PRSW 001 SSB SPRAY I/L COMMON ISO. VALVE MOV 30 ML-COMBUSTOR REAR RIGHT CORNER
219 PRSW 002 SSB SPRAY I/L PCV PNEU 30 ML-COMBUSTOR REAR RIGHT CORNER
220 PRSW 004 SSB SPRAY MAIN LINE I/L ISO. VALVE MOV 30 ML-COMBUSTOR REAR RIGHT CORNER
221 PRSW 010 SSB SPRAY B/P LINE I/L ISO. VALVE MOV 30 ML-COMBUSTOR REAR RIGHT CORNER
222 PRSW 007 SSB SPRAY MAIN LINE TCV PNEU 30 ML-COMBUSTOR REAR RIGHT CORNER
223 PR SW 014 SSB SPRAY B/P LINE TCV PNEU 30 ML-COMBUSTOR REAR RIGHT CORNER
224 SB014 BACK PASS SSB DRAIN TEMP.CONTROL PNEU 10.5 ML-BACK PASS RIGHT SIDE(NEAR RH SPRAY STATION)
VALVE ( TDV1)
225 SB020 TAPH SSB DRAIN TEMP.CONTROL PNEU 10.5 ML-BACK PASS RIGHT SIDE(NEAR RH SPRAY STATION)
VALVE (TDV2)

Page 18 of 36
Sl.no VALVE NO DESCRIPTION TYPE LOCATION OPEN CLOSE REMARKS
BED MATERIAL FEEDING SYSTEM
226 FLUIDISING HOPPER FLUIDISING VALVE FOR SOV 27 ML-COMBUSTOR FRONT LEFT
GATE VLV LEFT BUNKER
227 FEED GATE BED MATERIAL BUNKER O/L PNEU 18 ML COMBUSTOR FRONT LEFT CORNER
VLV(L) ISO.GATE(LEFT)
228 FLUIDISING HOPPER FLUIDISING VALVE FOR SOV 27 ML-COMBUSTOR FRONT RIGHT
GATE VLV RIGHT BUNKER
229 FEED GATE BED MATERIAL BUNKER O/L PNEU 18 ML COMBUSTOR FRONT RIGHT CORNER
VLV(R) ISO.GATE(RIGHT)
230 SEAL AIR PURGE AND SEAL AIR VALVE FOR PNEU 18 ML COMBUSTOR FRONT LEFT CORNER
ISO.VLV(L) SEALING LEFT I/L LINE
231 SEAL AIR PURGE AND SEAL AIR VALVE FOR PNEU 18 ML COMBUSTOR FRONT RIGHT CORNER
ISO.VLV(R) SEALING RIGHT I/L LINE
232 ISO GATE (L1) BM BUNKER (L) FILLING STREAM – I PNEU BUNKER BAY LEVEL
ISOLATION GATE
233 ISO GATE (L2) BM BUNKER (L) FILLING STREAM – II PNEU BUNKER BAY LEVEL
ISOLATION GATE
234 ISO GATE (R1) BM BUNKER (R) FILLING STREAM – I PNEU BUNKER BAY LEVEL
ISOLATION GATE
235 ISO GATE (R2) BM BUNKER (R) FILLING STREAM – II PNEU BUNKER BAY LEVEL
ISOLATION GATE

LIME FEEDING SYSTEM


236 FLUIDISING HOPPER FLUIDISING VALVE FOR SOV 27 ML-COMBUSTOR LEFT FRONT
GATE VLV LEFT BUNKER
237 FEED GATE LIME BUNKER OUTLET ISO.GATE( LEFT) PNEU 24 ML COMBUSTOR LEFT FRONT CORNER
VLV(L)
238 FLUIDISING HOPPER FLUIDISING VALVE FOR SOV 27 ML-COMBUSTOR RIGHT FRONT
GATE VLV RIGHT BUNKER
239 FEED GATE LIME BUNKER OUTLET ISO.GATE( RIGHT) PNEU 24 ML COMBUSTOR RIGHT FRONT CORNER
VLV(R)
240 ISO GATE (L1) LIME BUNKER (L) FILLING STREAM – I PNEU BUNKER BAY LEVEL
ISOLATION GATE
241 ISO GATE (L2) LIME BUNKER (L) FILLING STREAM – II PNEU BUNKER BAY LEVEL
ISOLATION GATE
242 ISO GATE (R1) LIME BUNKER (R) FILLING STREAM – I PNEU BUNKER BAY LEVEL
ISOLATION GATE
243 ISO GATE (R2) LIME BUNKER (R) FILLING STREAM – II PNEU BUNKER BAY LEVEL
ISOLATION GATE

Page 19 of 36
Sl.no VALVE NO DESCRIPTION TYPE LOCATION OPEN CLOSE REMARKS
244 UNIT #1 ISO LINE ISO GATE IN UNIT #1 PNEU BUNKER BAY LEVEL
GATE-I STREAM - I
245 UNIT #1 ISO LINE ISO GATE IN UNIT #1 PNEU BUNKER BAY LEVEL
GATE-II STREAM - II
BED ASH SYSTEM
246 ISO.GATE-LEFT BED ASH COOLER OUTLET GATE (LEFT) PNEU 2 ML ABOVE ISG CONVEYOR-LEFT
247 ISO.GATE-RHS BED ASH COOLER OUTLET GATE (RIGHT) PNEU 2 ML ABOVE ISG CONVEYOR-RIGHT
LIME HANDLING SYSTEM
248 COMBUSTION AIR DAMPER MOD 0 ML-LIME PLANT-HAG-LEFT SIDE
249 DILUTION AIR DISCHARGE DAMPER MOD 0 ML-LIME PLANT-HAG-RIGHT SIDE
250 HOT AIR I/L DAMPER TO BALL MILL321 MOD BALL MILLREAR -3ML-LIME PLANT
251 HOT AIR I/L DAMPER TO BALL MILL322 MOD BALL MILLREAR -3ML-LIME PLANT
252 ATOMISING AIR BTV PNEU 0ML-HAG REAR SIDE
253 LDO BTV PNEU 0ML-HAG REAR SIDE
254 MOLLER VALVE FOR CONVEYING SOV LIME MILLING PLANT
VESSEL A1- I/L
255 MOLLER VALVE FOR CONVEYING SOV LIME MILLING PLANT
VESSEL A2- I/L
256 MOLLER VALVE FOR CONVEYING SOV LIME MILLING PLANT
VESSEL B1- I/L
257 MOLLER VALVE FOR CONVEYING SOV LIME MILLING PLANT
VESSEL B2- I/L
258 NUCON VALVE FOR CONVEYING SOV LIME MILLING PLANT
VESSEL A1-O/L TO PRODUCTION BIN
259 NUCON VALVE FOR CONVEYING SOV LIME MILLING PLANT
VESSEL A2-O/L TO PRODUCTION BIN
260 NUCON VALVE FOR CONVEYING SOV LIME MILLING PLANT
VESSEL B1-O/L TO PRODUCTION BIN
261 NUCON VALVE FOR CONVEYING SOV LIME MILLING PLANT
VESSEL B2-O/L TO PRODUCTION BIN
262 ROTEX VALVE FOR CONVEYING SOV LIME MILLING PLANT
VESSEL-A1
263 ROTEX VALVE FOR CON. VESSEL –A2 SOV LIME MILLING PLANT
264 ROTEX VALVE FOR CONVEYING SOV LIME MILLING PLANT
VESSEL-B1

Page 20 of 36
Sl.no VALVE NO DESCRIPTION TYPE LOCATION OPEN CLOSE REMARKS
265 ROTEX VALVE FOR CONVEYING SOV LIME MILLING PLANT
VESSEL-B2
266 MOLLER VALVE FOR CONVEYING SOV LIME MILLING PLANT
VESSEL A1- O/L
267 MOLLER VALVE FOR CONVEYING SOV LIME MILLING PLANT
VESSEL A2- O/L
268 MOLLER VALVE FOR CONVEYING SOV LIME MILLING PLANT
VESSEL B1- O/L
269 MOLLER VALVE FOR CONVEYING SOV LIME MILLING PLANT
VESSEL B2- O/L
270 ROTEX VALVE FOR CONVEYING LINE- SOV LIME MILLING PLANT
A1/B1
271 ROTEX VALVE FOR CONVEYING LINE- SOV LIME MILLING PLANT
A1/B1
272 ROTEX VALVE FOR CONVEYING LINE- SOV LIME MILLING PLANT
A2/B2
273 ROTEX VALVE FOR CONVEYING LINE- SOV LIME MILLING PLANT
A2/B2
274 LOUVRE DAMPER FOR ID FAN-1 MOD 2 ML-ID DISCHARGE LEFT
275 LOUVRE DAMPER FOR ID FAN-2 MOD 2 ML-ID DISCHARGE RIGHT

Page 21 of 36
Page 22 of 36
LEGEND

• APRDS-AUXILLARY PRESSURE REDUCING & DESUPERHEATING • LC- LOW CAPACITY


STATION • LDO-LIGHT DIESEL OIL
• ATM - ATOMISING • LL-LOW LOAD
• B/P-BYPASS • LPG-LIQUEIFIED PETROLEUM GAS
• BEF-BEFORE • LT AST-LOW TEMPERATURE AUXILLARY STEAM
• BTV-BURNER TRIP VALVE • LT-LOW TEMPERATURE
• CBD-CONTINUOUS BLOW DOWN • MFT-MASTER FUEL TRIP
• COMB.-COMBUSTOR • ML-METER LEVEL
• CON.-CONVEYING • MOD-MOTOR OPERATED DAMPER
• CV-CONTROL VALVE • MOV-MOTOR OPERATED VALVE
• DESH-DE SUPERHEATING • MS-MAIN STEAM
• DRN-DRAIN • MTV-MAIN TRIP VALVE
• EC-EMPTY CHAMBER • O/L -OUTLET
• ECO-ECONOMISER • P&S-PURGE AND SEAL
• ESP-ELECTO STATIC PRECIPITATOR • PA-PRIMARY AIR
• FBHE-FLUIDIZED BED HEAT EXCHANGER • PCV-PRESSURE CONTROL VALVE
• FCV-FLOW CONTROL VALVE • PNEU-PNEUMATIC
• FL-FULL LOAD • R/C-RECIRCULATION
• FLR-FLOOR • REG-REGULATING
• FOPH-FUEL OIL PUMP HOUSE • RH-REHEATER
• HC-HIGH CAPACITY • SA-SECONDARY AIR
• HDR-HEADER • SEC-SECONDARY
• HFO-HEAVY FURNACE OIL • SH –SUPER HEATER
• HT-HIGH TEMPERATURE • SOV-SOLENOID OPERATED VALVE
• I/L –INLET • SSB-STEAM SOOT BLOWER
• IBD-INTERMITTENT BLOW DOWN • STDBY-STAND BY
• ID-INDUCED DRAUGHT • SUB-START UP BURNER
• IGV-INLET GUIDE VANE • SUC-SUCTION
• ISO.-ISOLATION • TCV-TEMPERATURE CONTROL VALVE
• VLV-VALVE

Page 23 of 36
TURBINE EQUIPMENTS DETAILS

Sl.
Equipment Description kV kW Location Start Stop Remarks
No:
Circulating Water Pumps
Circulating Water
1 Circulating Water Pump-1A (CWP) 6.6 760 Pump House (FWPH
Side)
Circulating Water
2 Circulating Water Pump-1B (CWP) 6.6 760
Pump House

3 Circulating Water Pump-1C (CWP) 6.6 760 Circulating Water


Pump House

4 Circulating Water Pump-2A (CWP) 6.6 760 Circulating Water


Pump House

5 Circulating Water Pump-2B (CWP) 6.6 760 CWPH (Control


Room Side)
Fire Hydrant System
Fire Water Pump
6 Hydrant Pump-1 (AC Motor) 0.4 110 house (Entrance
Side)
Fire Water Pump
7 Hydrant Pump-2 (AC Motor) 0.4 110 house
Fire Water Pump
8 Hydrant Pump-3 (Diesel Engine) - 115 house
Fire Water Pump
9 Spray Pump-1 (AC Motor) 0.4 110 house
Fire Water Pump
10 Spray Pump-2 (Diesel Engine) - 115 house
Fire Water Pump
11 Jockey Pump-1 (AC Motor) 0.4 15 house

Page 24 of 36
Sl.
Equipment Description kV kW Location Start Stop Remarks
No:
Fire Water Pump
12 Jockey Pump-2 (AC Motor) 0.4 15 house (MCC Side)
Main Turbine Oil Pumps
13 Main Oil Pump-1 0.4 37 MOT TOP
MOT TOP/Ladder
14 0.4 37
Main Oil Pump-2 Side
15 Emergency Oil Pump 220 15 MOT TOP 220 V DC
16 Lift Oil Pump-1 0.4 37 MOT TOP
MOT TOP/Ladder
17 220 37
Lift Oil Pump-2 Side 220 V DC
18 Oil Vapor Extraction Fan-1 0.4 1.1 MOT TOP
MOT TOP/Ladder
19 0.4 1.1
Oil Vapor Extraction Fan-2 Side
20 Control Oil Pump-1 0.4 15 MOT ROOM
MOT ROOM/A-Row
21 0.4 15
Control Oil Pump-2 Side
22 Control Oil Pump-Recirculation 0.4 0.75 MOT ROOM
23 Centrifuge Seperator Motor 0.4 3 MOT ROOM
24 Centrifuge Feed Motor 0.4 1 MOT ROOM
Boiler Feed Pumps (BFP)
0 ML,Nearer to
25 BFP-A 6.6 4000
Condenser

26 BFP-B 6.6 4000 0 ML

Condensate Extraction Pump (CEP)

27 CEP-A 6.6 340 Condenser Pit (Left)

Condenser Pit
28 CEP-B 6.6 340 (Nearer to
Condenser)

Page 25 of 36
Sl.
Equipment Description kV kW Location Start Stop Remarks
No:
De Mineralized Cooling Water Pumps (DMCW Pumps)
29 DMCWP-A 6.6 250 0 ML
0 ML, Condenser
30 DMCWP-B 6.6 250 (Nearer to B-Row)
DMCW Booster Pumps

31 DMCWBP-A 0.4 125 0 ML, Left D-E Row


(Nearer to TG Hall)
32 DMCWBP-B 0.4 125 0 ML, Left D-E Bay
Auxiliary Cooling Water Pumps (ACW
Pumps)
33 ACW-A 0.4 75 0 ML, Cond Front
0 ML, Cond Front
34 0.4 75 (Nearer to
ACW-B Condenser)
Hot Well Make Up Pumps (HWMUP)

35 0.4 18.5 0' ML, D-E Row CST


HWMUP-A Area

36 0.4 18.5 0' ML, D-E Row CST


HWMUP-B Area

37 0.4 18.5 0' ML, (Nearer to


HWMUP-C EDM Pumps)
Boiler Fill Pumps
38 0.4 75 0' ML, D-E Row CST
Boiler Fill Pump-A Area

39 0.4 75 0' ML, Nearer to


Boiler Fill Pump-B HWMU Pumps
HPBP Oil Supply Units (OSU)
40 OSU Pump-A 0.4 7.5 5' ML, Above BFP
41 OSU Pump-B 0.4 7.5 5' ML, Above BFP

Page 26 of 36
Sl.
Equipment Description kV kW Location Start Stop Remarks
No:
Gland Steam Evacuation Fans (GSEF)
42 GSEF-A 0.4 3.75 5 ML
GSEF-B 5 ML, Nearer to
43 0.4 3.75
Ejector
Chemical Dozing Pumps
0' ML, Nearer to
44 Hydrazine Pump-1 0.4 0.75
AFT,Unit#1
0' ML, Near
45 0.4 0.75
Hydrazine Pump-2 AFT,Unit#1
0' ML, Near
46 0.4 0.75
Hydrazine Pump-3 AFT,Unit#1
0' ML, Near
47 0.4 0.75
Hydrazine Pump-4 AFT,Unit#1
0' ML, Nearer to
48 Ammonia Pump-1 0.4 0.75
AFT,Unit#1
0' ML, Near
49 0.4 0.75
Ammonia Pump-2 AFT,Unit#1
0' ML, Near
50 0.4 0.75
Ammonia Pump-3 AFT,Unit#1
0' ML, Near
51 0.4 0.75
Ammonia Pump-4 AFT,Unit#1
Condenser Sump Pump
0' ML, Cond Front
52 0.4 7.5
Sump Pump-1 (Rt)
Condenser Tube Cleaning System
0' ML, Cond Front
53 0.4 5.5
Ball R/c Pump-1 (Lt)
0' ML, Cond Front
54 0.4 5.5
Ball R/c Pump-2 (Rt)

Page 27 of 36
Sl.
Equipment Description kV kW Location Start Stop Remarks
No:
Emergency Systems
Emergency BFPs (EBFP)
0 ML,D-E Row
55 EBFP-1 (Diesel Engine) - 1122 Behind ISG
ControlRoom:U#1
0 ML,D-E Row
56 EBFP-2 (Diesel Engine) - 1122 Behind ISG
ControlRoom:U#2
Compressor Room,
57 Emg Instrument Air Compressor 0.4 30 Nearer to BFPs of
U#1
Emergency DM Makeup Pumps (EDMWP)
0' ML,Nearer to
58 0.4 35
EMDWP-A HWMU Pumps
0' ML, D-E Row CST
59 0.4 35
EMDWP-B Area

Emergency Cooling Water Pumps (ECWP)


0' ML, D-E Bay CST
60 0.4 30
ECWP-A Area
0' ML, D-E Bay CST
61 0.4 30
ECWP-B Area
0' ML, Nearer to
62 0.4 30
ECWP-C B.Fill Pumps

Page 28 of 36
Sl.
Equipment Description kV kW Location Start Stop Remarks
No:
Air Compressors

63 Service Air Compressor-1 0.4 525 Compressor Room,


Nearer to IACs
64 Service Air Compressor-2 0.4 525 Compressor Room

65 Instrument Air Compressor-1 0.4 145 Compressor Room,


Nearer to Emg-IAC
66 Instrument Air Compressor-2 0.4 145 Compressor Room

Page 29 of 36
TURBINE VALVE LOCATIONS
Sl.
No: Tag No: Service Description Type Location Open Close Remarks
DM Water Make Up System
1 DM-27 Hot well make up valve(high capacity) Pneumatic 0 ML-Near Condenser
2 DM-30 Hot well make up valve( Low capacity) Pneumatic 0 ML-Cond.rear-B-Row
3 DM-40 Deaerator filling from boiler fill pump MOV Deaerator Level
4 DM-42 DMW Plant to CST MOV CST Top
5 DM-51 By pass valve for MakeUp to Condenser MOV 0'ML/B-row/Cond Rear
6 DM-60 EDM.Make up valve MOV 0' ML at EDM tank top inlet
7 DM-64 EDM Pump-A Discharge Valve MOV CST Area: Near HWMU Pump
8 DM-67 EDM Pump-B Discharge Valve MOV 0' ML- CST Area
9 DM-71 EDM Make Up to Deaerator Pneumatic Deaerator Level
10 DM-73 EDM Make Up to Deaerator(Bypass Valve) MOV Deaerator Level
Main Condensate Scheme
11 CS-1 CEP 'A' Suction Valve MOV In CEP Pit
12 CS-2 CEP 'B' Suction Valve MOV In CEP Pit: Condenser Side
13 CD-3 CEP 'A' Discharge Valve MOV Near CEP / '0' ML
14 CD-4 CEP 'B' Discharge Valve MOV Near CEP/'0' ML (Cond. Side)
15 CD-5 CEP 'A' Discharge Bypass Valve MOV Near CEP / '0' ML
16 CD-6 CEP 'B' Discharge Bypass Valve MOV Near CEP / '0' ML
17 CD-13 ME 'A' &'B' Bypass Valve MOV/Inch Below ME @ '0' ML
18 CD-18 Valve Before CD-19 (Dea Level Control) MOV 5 ML Condenser Rear
19 CD-19 Deaerator Level Control Valve Pneumatic 5 ML Condenser Rear
20 CD-21 Bypass Valve of CD-19 (Dea Level Control) MOV/Inch 5 ML Condenser Rear
21 CD-23 Excess Condensate Dumping to CST Pneumatic 5 ML Condenser Rear
22 CD-25 Excess Condensate Dumping to CST-Bypass MOV/Inch 5 ML Condenser Rear
23 CD-27 CEP Minimum Recirculation Valve Pneumatic 5 ML Condenser Left
24 CD-29 CEP Minimum Recirculation Bypass MOV/Inch 5 ML Condenser Left

Page 30 of 36
Sl.
No: Tag No: Service Description Type Location Open Close Remarks
25 CD-30 Drain Cooler Inlet MOV 0 ML Condenser Rear
26 CD-31 LPH-1 Outlet MOV '5' ML
27 CD-32 DC&LPH-1 Bypass MOV '5' ML
28 CD-33 LPH-2 Inlet Isolation MOV '0' ML
29 CD-34 LPH-2 Outlet Isolation MOV '0' ML
30 CD-35 LPH-2 Bypass Valve MOV '0' ML
31 CD-36 LPH-3 Inlet Isolation MOV '0' ML
32 CD-37 LPH-3 Outlet Isolation MOV '0' ML
33 CD-38 LPH-3 Bypass Valve MOV '0' ML
34 CD-40 MC Inlet to Deaerator MOV Deaerator Dome
35 CD-60 Valve Gland Sealing Control Valve Pneumatic 5 ML Condenser Rear Left
Feed Water System
36 FS-1 BFP-'A' Suction Valve MOV BFP '0' ML(before filter)
37 FS-2 BFP-'B' Suction Valve MOV BFP '0' ML(before filter)
38 FC-1 BFP-A Recirculation Valve Pneumatic 5 ML above BFP
39 FC-4 BFP-B Recirculation Valve Pneumatic 5 ML above BFP
40 FD-2 BFP-A Discharge Valve MOV BFP '0' ML
41 FD-2A BFP-A Discharge Bypass Valve MOV BFP '0' ML
42 FD-4 BFP-B Discharge Valve MOV BFP '0' ML
43 FD-4A BFP-B Discharge Bypass Valve MOV BFP '0' ML
HP Heaters
44 FD-7 Inlet Sempell Valve for HPH5 Hydraulic HPH-5, '0' ML
45 FD-8 Outet Sempell Valve for HPH5 Hydraulic HPH-5, '0' ML
46 FD-10 Inlet Sempell Valve for HPH6 Hydraulic HPH-6, '0' ML
47 FD-11 Outet Sempell Valve for HPH6 Hydraulic HPH-6, '0' ML
48 FD-68 HPH-5 Group Protection SOV-1 Pneumatic HPH-5, '0' ML
49 FD-71 HPH-5 Group Protection SOV-2 Pneumatic HPH-5, '0' ML
50 FD-75 HPH-6 Group Protection SOV-1 Pneumatic HPH-6, '0' ML

Page 31 of 36
Sl.
No: Tag No: Service Description Type Location Open Close Remarks
51 FD-32 HPH-6 Group Protection SOV-2 Pneumatic HPH-6, '0' ML
52 FD-33 HPH-6, Dump Valve MOV HPH-5, '0' ML
53 FD-72 HPH-5, Dump Valve MOV HPH-6, '0' ML
Heaters Drain Condensate System
54 DR-2 HPH-6 Normal Level Control vlv to HPH5 Pneumatic HPH-5, 5 ML
55 DR-6 HPH-6 Normal Level Control valve to Dea Pneumatic Deaerator level
56 DR-9 HPH-6 HIgh Level Control valve to HPFT Pneumatic HPFT , '0' ML
57 DR-13 HPH-5 Normal Level Control valve to Dea Pneumatic Deaerator level
58 DR-16 HPH-5 HIgh Level Control valve to HPFT Pneumatic HPFT , '0' ML
59 DR-19 LPH-3 Normal Level Control vlv to LPH2 Pneumatic 5 ML , LPH2 area
60 DR-22 LPH-3 HIgh Level Control vlv to LPFT Pneumatic LPFT, '0' ML
61 DR-25 LPH-2 Normal Level Control vlv to LPH1 Pneumatic 5 ML, Condenser Left
62 DR-28 LPH-2 HIgh Level Control vlv to LPFT Pneumatic LPFT, '0' ML
63 DR-38 Deaerator Over Flow to LPFT Pneumatic LPFT, '0' ML
Evacuation System
64 SM-10 Starting Ejector Air Valve MOV 5 ML, Ejector area
65 SM-11 Main Ejector-A, Air Valve MOV 5 ML, Ejector area
66 SM-12 Main Ejector-B, Air Valve MOV 5 ML, Ejector area
67 SM- MAG10AA001A(VAC.BREAKER VALVE) Pneumatic 5 ML-Right side of condenser
Main Steam Line
68 MS-101 MS Strainer Drain(Rt) to Atm FT MOV 0 ML, AFT
69 MS-104 MS Strainer Drain(Lt) to Atm FT MOV 0 ML, AFT
Cold Reheat Line
70 CRH-1 CRH Steam to Dea Isolation valve MOV Deaerator Level
71 CRH-1A CRH Steam to Dea Isolation valve (bypass) MOV Deaerator Level
72 CRH-2 CRH Steam to Dea Pegging Control vlv Pneumatic Deaerator Level
73 CRH-4 CRH Steam to Dea Pegging Bypass vlv MOV/Inch Deaerator Level
74 CRH-7 CRH Steam to Seals Isolation valve MOV 5 ML, Near HPBP area

Page 32 of 36
Sl.
No: Tag No: Service Description Type Location Open Close Remarks
75 CRH-101 CRH NRV Drain to HPFT MOV HPFT, 0 ML
76 CRH-120 CRH NRV Drain to HPFT MOV HPFT, 0 ML
77 CRH-123 CRH NRV/Line Drain to Atm FT MOV AFT, 0 ML
78 CRH-124 CRH NRV/Line Drain to Atm FT MOV AFT, 0 ML
Hot Reheat Line & LPBP System Drains
79 HRH-101 HRH(Lt) Strainer Drain to HPFT MOV HPFT, 0 ML
80 HRH-102 HRH(Rt) Strainer Drain to HPFT MOV HPFT, 0 ML
81 HRH-103 LPBP(Lt) Warm Up Drain to HPFT MOV HPFT, 0 ML
82 HRH-104 LPBP(Rt) Warm Up Drain to HPFT MOV HPFT, 0 ML
83 HRH-113 LPBP(Lt) Line Drain to HPFT MOV HPFT, 0 ML
84 HRH-118 LPBP(Rt) Line Drain to HPFT MOV HPFT, 0 ML
85 HRH-122 HRH(Lt) Strainer Drain to Atm FT MOV AFT, 0 ML
86 HRH-123 HRH(Rt) Strainer Drain to Atm FT MOV AFT, 0 ML
Steam to Seals and Ejector (AST)
87 AS-1 AST to Deaerator Pegging Isolation vlv MOV Deaerator Level
88 AS-2 AST to Deaerator Pegging Control vlv Pneumatic Deaerator Level
89 AS-5 AST to Dea Pegging Control Bypass vlv MOV/Inch Deaerator Level
90 AS-7 AST Preheating to Deaerator MOV/Inch Deaerator Level
91 AS-9 AST to Seal Steam Header MOV HT PRDS header -15 ML.
92 AS-11 AST to Starting Ejector MOV Ejector area, 5 ML
93 AS-12 AST to Main Ejector-A MOV Ejector area, 5 ML
94 AS-13 AST to Main Ejector-B MOV Ejector area, 5 ML
Steam to Seals and Ejector (AST)- Continued
95 MAW- MAW-10 Bypass valve(MAW10AA504) MOV Seals Steam Header, 5 ML
96 MAW- MAW-50 Bypass valve(MAW50AA503) MOV Seals Steam Header, 5 ML
97 MAW- MAW-10 Before Line Drain(MAW10AA011) MOV Seals Steam Header, 5 ML
98 MAW-10 Steam to seals PCV Pneumatic Seals Steam Header, 5 ML
99 MAW-50 Steam to seals dumping valve Pneumatic Seals Steam Header, 5 ML

Page 33 of 36
Sl.
No: Tag No: Service Description Type Location Open Close Remarks
HP Bypass System
100 BP-2 HPBP Warm up line (BP-5) MOV/Inch HPBP area, 5 ML
101 BP-4 HPBP Warm up line (BP-6) MOV/Inch HPBP area, 5 ML
102 BP-5 HP BP main valve -A side HYDRAULIC HPBP area, 5 ML
103 BP-6 HP BP main valve -B side HYDRAULIC HPBP area, 5 ML
104 BP-102 HPBP Line Drain (BP-5) MOV AFT, 0 ML
105 BP-104 HPBP Line Drain (BP-6) MOV AFT, 0 ML
106 BD HP BP Spray isolation valve HYDRAULIC HPBP area, 5 ML
107 BPE-1 BP 5-Spray valve HYDRAULIC HPBP area, 5 ML
108 BPE-2 BP 6-Spray valve HYDRAULIC HPBP area, 5 ML

LP Bypass system
109 LPBP-SV1 MAN51AA011A(LP BP stop valve-1) HYDRAULIC At 5 ML, Cond.front
110 LPBP-SV2 MAN61AA011A(LP BP stop valve-2) HYDRAULIC At 5 ML, Cond.front
111 LPBP-CV1 MAN52CG151XQ07(LP BP control valve-1) HYDRAULIC At 5 ML, Cond.front
112 LPBP-CV2 MAN62CG151XQ07(LP BP control valve-2) HYDRAULIC At 5 ML, Cond.front
113 WI-V1 MAN53AA001( Water injection valve-1) Pneumatic At 5 ML, Cond.front
114 WI-V2 MAN63AA001( Water injection valve-2 ) Pneumatic At 5 ML, Cond.front
Turbine Drains System
115 MAL-11 Drain Before HPCV-1 MOV MAL Area, 0 ML
116 MAL-12 Drain Before HPCV-2 MOV MAL Area, 0 ML
117 MAL-13 Drain Before OLCV MOV MAL Area, 0 ML
118 MAL-15 Drain After HPCV-1 MOV MAL Area, 0 ML
119 MAL-16 Drain After HPCV-2 MOV MAL Area, 0 ML
120 MAL-22 HP Casing Drain MOV MAL Area, 0 ML
121 MAL-24 HP/IP Casing Drain MOV MAL Area, 0 ML
122 MAL-26 Drain Before IPCV-1 MOV MAL Area, 0 ML
123 MAL-27 Drain Before IPCV-2 MOV MAL Area, 0 ML

Page 34 of 36
Sl.
No: Tag No: Service Description Type Location Open Close Remarks
124 MAL-30 Drain from HP Extraction Insert MOV MAL Area, 0 ML
125 MAL-31 Drain After IPCV-1 MOV MAL Area, 0 ML
126 MAL-32 Drain After IPCV-2 MOV MAL Area, 0 ML
127 MAL-35 Drain from IP Extraction Insert MOV MAL Area, 0 ML
128 MAL-47 Drain Before Ext-A5 MOV MAL Area, 0 ML
129 MAL-51 Extraction A4 Drain MOV MAL Area, 0 ML
130 MAL-54 Extraction A3 Drain MOV MAL Area, 0 ML
131 MAL-65 Drain Before CRH NRV MOV MAL Area, 0 ML
132 MAL-81 Gland Seal Header Drain MOV MAL Area, 0 ML
133 MAL- LBC11AA010A(HP exhaust dump valve) Pneumatic MAL Area, 0 ML

Circulating Water System


134 CW-01 Circulating Water Inlet, A Side MOV Condenser Front, 0 ML
135 CW-06 Circulating Water Outlet, A Side MOV Condenser Front, 0 ML
136 CW-07 Circulating Water Inlet, B Side MOV Condenser Front, 0 ML
137 CW-12 Circulating Water Outlet, B Side MOV Condenser Front, 0 ML
DM Cooling Water System
138 DMCW-82 DMCW Over Head Tank Make Up Valve MOV 15 ML, Near AST PRDS Room
139 DMCW-18 BFP-A: DMCW Isolation Valve MOV 0' ML near BFP A suction filter
140 DMCW-35 BFP-B: DMCW Isolation Valve MOV 0' ML near BFP B suction filter
EDM Cooling Water System
141 ECW-1 ECW Inlet to Spiess Valve Header MOV Boiler left-4 ML-E row
142 ECW-2 DMCW Inlet to Spiess Valve Header MOV Boiler left-4 ML-E row
143 ECW-3 DMCW Outlet to Spiess Valve Header MOV Boiler left-4 ML-E row
144 ECW-4 ECW Outlet to Spiess Valve Header MOV Boiler left-4 ML-E row
Turbine Extractions & Drains
145 Ex-9 Extraction Steam Valve to LPH-2 MOV 5' ML Condenser Rear Left
146 Ex-10 Extraction Steam Valve to LPH-3 MOV 5' ML Condenser Rear Left

Page 35 of 36
Sl.
No: Tag No: Service Description Type Location Open Close Remarks
147 Ex-11 Extraction Steam Valve to Deaerator MOV 20.5' ML Deaerator level
148 Ex-12 Extraction Steam Valve to HPH-5 MOV 5' ML Condenser Rear Right
149 Ex-13 Extraction Steam Valve to HPH-6 MOV 5' ML Condenser Rear Right
150 Ex-104 HPH-5 Extraction Line Drain MOV HP Flash Tank
151 Ex-106 HPH-6 Extraction Line Drain MOV HP Flash Tank
152 Ex-116 Deaerator Extraction Line Drain Valve MOV LP Flash Tank
153 Ex-119 LPH-3 Extraction Line Drain MOV LP Flash Tank
154 Ex-120 LPH-2 Extraction Line Drain MOV LP Flash Tank

Page 36 of 36

You might also like