Download as pdf or txt
Download as pdf or txt
You are on page 1of 19

ABB PSPG-E7

Optimax Plant Performance Monitoring


Key performance indicators,
controllable losses, what-if
© ABB Group
May 8, 2014 | Slide 1
© ABB
OPTIMAX® Plant Performance Monitoring
Challenge

 Power plant operators are in charge to keep up efficiency


under continuously changing loads.
 Power plant maintenance staff shall reduce both unplanned
outages and maintenance costs.
 Power plant managers strive for meaningful figures for
strategic decisions.

© ABB Group
May 8, 2014 | Slide 2
© ABB
OPTIMAX® Plant Performance Monitoring
Solution

Features
 Standard tool library (ISO, ASME, DIN)
for easy calculation engineering
 Calculates deviations between actual
and expected performance
 Converts performance deviation to
short- and long-term degradation
 Interface to ABB‘s Power Generation
Information Management System
(PGIM)

© ABB Group
May 8, 2014 | Slide 3
© ABB
OPTIMAX® Plant Performance Monitoring
Starting point: monitoring of process values in DCS

Process values alone usually give no information


about the efficiency or the process quality of a plant

12.8
12.0 12.4 11.8
12.3
123,453 12,2 23.4
12,5 2,4
3,7
0,2233
23.4
4,0 12.4
12.6 23.4

© ABB Group
May 8, 2014 | Slide 4
© ABB
OPTIMAX® Plant Performance Monitoring
Determination of performance indicators

Performance indicators are determined by using


multiple process values

90% 39% 12.8


12.0 12.4 11.8 87%
72% 12.3
123,453 12,2 23.4
12,5 2,4
3,7
0,2233
23.4
4,0 12.4
12.6 23.4

96% 68% 72%


© ABB Group
May 8, 2014 | Slide 5
© ABB
OPTIMAX® Plant Performance Monitoring
Key performance indicator example: condenser

T1 T2

FCoolWater TC = Tsaturated (PCondenser)

Qth = FCoolWater * spec.HeatCoeffWater * (T2 - T1)


A = Condenser Surface

Heat Transfer Coefficient kActual =

Source:
ABB Technik 3/1997
© ABB Group
May 8, 2014 | Slide 6
© ABB
OPTIMAX® Plant Performance Monitoring
Key performance indicators module library

 Steam Generators  Air preheaters


(fossil-fired, SG)  Condensers
 Heat Recovery Steam  Pumps, fans
Generators (HRSG)
 Generators
 Combustion stoichiometry
(for SG or HRSG)  Overall plant balance
 Gas turbines  Auxiliary power and steam
 Steam turbines  District heat
 Feed water heaters  Process steam
 Evaporators  Mathematical and statistical
calculations
 Super heaters
 Water/steam properties
 Heat exchangers
 Gas properties
 Desuperheaters

© ABB Group
May 8, 2014 | Slide 7
© ABB
OPTIMAX® Plant Performance Monitoring
Generation of reference values

dP primary air fan [mBAR] over Current primary air fan [A] from
20.04.2011 to 01.05.2012
• Online calculation of
reference values depending
180
on e.g.
160
 Temperature
140

120  Air pressure


100
 Load
80
y = -0.006x2 + 1.8903x + 22.553
R² = 0.9694
 Fuel sort
60

40  ...
20
• Reference characteristics
0
0 20 40 60 80 100 120
extracted from heat
balance sheets or fitted to
archived process data from
acceptance tests of new
plant or after major retrofit
© ABB Group
May 8, 2014 | Slide 8
© ABB
OPTIMAX® Plant Performance Monitoring
Calculations configuration

© ABB Group
May 8, 2014 | Slide 9
© ABB
OPTIMAX® Plant Performance Monitoring
Controllable losses

• Flue-gas temperature at boiler exit


• O2 flue gas concentration at boiler exit
• Electrical auxiliary power
• Condenser pressure
• Condensate water temperature at feed
water tank inlet
• Feed water temperature at boiler inlet
• Feed water temperature at economizer
outlet
• Live steam temperature
• Live steam pressure
Controllable losses include measured process
values that can be controlled by the plant Process mimic presents for each controllable loss:
operator and having a known impact on plant
energy losses when deviating from the design • Actual measurement value
point, e.g.: • Design value (=expected value)
• Impact on plant efficiency / heat rate
• Additional plant fuel consumption due
to actual deviation from design value
© ABB Group
May 8, 2014 | Slide 10
© ABB
OPTIMAX® Plant Performance Monitoring
What if calculations

 Replace controllable losses


actual measurement values
by manually defined “What-
if” values.
 The calculation shows the
impact of all deviations of
controllable losses from
their design values.

© ABB Group
May 8, 2014 | Slide 11
© ABB
OPTIMAX® Plant Performance Monitoring
Report of performance calculations

 Standard Reports e.g.:


 Consumed and produced quantities
 Components operating hours
 Actuators number of switching cycles
 Report of Performance Calculations
e.g.:
 Performance values averages,
standard deviations
 Performance values averages
clustered into specific
component/unit operation
ranges/modes

© ABB Group
May 8, 2014 | Slide 12
© ABB
OPTIMAX® Plant Performance Monitoring
Report configuration

© ABB Group
May 8, 2014 | Slide 13
© ABB
OPTIMAX® PlantPerformance
Standard calculation of performance deviations

act exp
Calculation according
to implemented Reference value
standards

reference
Measured
characteristic
inputs
curves

act
p1 p2 T1 Tamb FCW KPI=
exp

© ABB Group
May 8, 2014 | Slide 14
© ABB
OPTIMAX® PlantPerformance
Identifying the origin of performance deviations

Total Plant
exp
act

exp exp
act act

Plant Area 1 Plant Area 2

exp exp
act act

Component 1 Component 2
© ABB Group
May 8, 2014 | Slide 15
© ABB
OPTIMAX® Plant Performance Monitoring
Benefits

 Applicable for different plant


types
 Increases overall plant
efficiency by detecting sub-
optimal operation modes
 Improves plant availability
and predictive maintenance
strategies by detecting
material degradations

© ABB Group
May 8, 2014 | Slide 16
© ABB
OPTIMAX® Plant Performance Monitoring
Key performance indicators for steam power plants

 Steam generator  Preheater


 Thermal efficiency according to  Logarithmic linear medium
DIN or ASME PTC temperature difference
 Efficiency economizer  Heat rate impact
 Efficiency feed water preheater  Efficiency
 Condenser  Steam turbine
 Expected condenser pressure  Thermal efficiency/ heat rate
impact
 Cleanliness/heat rate
 Isentropic heat power extractions
 Shaft power
 Unit balances
 Heat rate of unit

 Auxiliary power consumption


 Auxiliary steam consumption
 Heat flow to district heating
© ABB Group
May 8, 2014 | Slide 18
© ABB
OPTIMAX® Plant Performance Monitoring
Key performance indicators for combined cycle power plants

 GT calculations acc. ISO2314, DIN4341,  HRSG calculations acc. ASME-PTC4.4


ASME-PTC22  Calculate actual thermal efficiency
 Calculate actual efficiency and exhaust according to either:
mass flow and enthalpy
 input / output method
 Correct expected power and efficiency
to ISO conditions based on correction  thermal loss method
curves for:  Calculate actual exergetic efficiency
 ambient air pressure, temperature,  Expected efficiency based on
humidity correction curves can be calculated
 dp inlet and exhaust by using the math and core tools

 grid frequency
 Calculate expected power and efficiency
from design curves

© ABB Group
May 8, 2014 | Slide 19
© ABB

You might also like