The TOFD procedure – What should
the content be?
Didier FLOTTÉ
TC 121
TS 14 751
,7
,4
,9
,1
,4
,6
,9
,1
,3
,6
,8
,0
,3
,5
,8
1,
0,
9
10
11
-1
-1
-9
-9
-8
-7
-6
-6
-5
-4
-3
-3
-2
-1
-0
0,
0,
1,
2,
3,
3,
4,
5,
6,
6,
7,
8,
9,
9,
0
1
2
3 matière
epaisseur (mm)
4 Locus
5 limite du faisceau
6 -20 dB
7 -6 dB
8
9
10
,7
,4
,9
,1
,4
,6
,9
,1
,3
,6
,8
,0
,3
,5
,8
1,
0,
9
10
11
-1
-1
-9
-9
-8
-7
-6
-6
-5
-4
-3
-3
-2
-1
-0
0,
0,
1,
2,
3,
3,
4,
5,
6,
6,
7,
8,
9,
9,
0
1
2
3 matière
epaisseur (mm)
4 Locus
5 limite du faisceau
6 -20 dB
7 -6 dB
8
9
10
Sensitivity setting
¾ The amplitude of the lateral wave is between 40% and 80% full screen
height with noise level less 10% FSH
¾ when no lateral wave, the amplitude of the back wall signal is between
18 dB and 30 dB above FSH.
¾ When the use of neither a lateral wave, nor a back wall signal is
appropriate, sensitivity should be set such that the material grain noise is
between 5% and 10% FSH.
Time window
¾ For full thickness examination using only one set-up :
o start at least 1 µs prior to the time of arrival of the lateral wave
o extend up to the first mode converted back wall echo and 1 µs
after
Scan resolution
¾ Thickness ≤ 10 mm : 0.5 mm
¾ Thickness > 10 mm : ≤ 1 mm
200 mm
Thickness Thickness
Of samples of blocks
6 mm – 12 mm 12 mm
150 15 mm 15 mm
16 mm – 20 mm 20 mm
75 3 mm
50 mm 2 mm
60 mm
25 mm – 25.4 mm 25 mm
35 mm
40 mm 20 mm
1/4 t 30 mm – 40 mm 40 mm
t
1/4 t
Diameter holes: 3 mm +/- 0,5 50 mm – 60 mm 60 mm
1/4 t
1/4 t 75 mm 75 mm
100 mm 100 mm
0.2 mm
2 mm
UT Testpiece
For calibration of
¾ Surface breaking :
o At scanning surface,
o At opposite surface
o Through wall
¾ Embedded indications :
o Point-like
o Elongated with a measurable height
o Elongated without a measurable height
¾ Transverse indications
¾ Uncategorised
¾ Point like :
o Pattern characterised by an arc shaped curve fitting with the
theoretical hyperbolic curve corresponding to the depth of the
indication
¾ Transverse indication :
o The presence of some mode converted echoes associated with a
point like indication may suggest that transverse defects could be
present.
Measuring length
¾ Linear indication (depth relatively constant) :
o A hyperbolic cursor is fitted at each o If not possible, the 6dB drop method
extremity ; distance between the cursor shall be used
give the length
Measuring length
¾ Time windows :
o start at least 1 µs prior to the time of arrival of the lateral wave
o extend up to the first mode converted back wall echo and 1 µs after
10 MHz
15 MHz