Caledonian Offshore Marine Cables Catalogue PDF

You might also like

Download as pdf
Download as pdf
You are on page 1of 150
Caledonian Caledonian Offshore & Marine Cables IEC60092 STANDARD == "a I, $ ADDISON www.caledonian-cables.co.uk www.addison-cables.com Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different cabling system products. Our superior products provide leading edge within every cable series and for every application. shasasanssssosssaseetesy v B e Registration Certificate ‘Among the national and international standards with which our cables could comply are: BS - British Standard; LPCB Fire Performance Standard, ISO Standard etc. Caledonian Cables offers a comprehensive stock of cables and cabling products through its nationwide network of resellers and distributors. Caledonian Cables has continually expanded its global presence in Europe and Asia ROR R BIER E EERE BORIC Caledonian & Addison, produces a wide range of cables for ‘communication, power and electronics in its primary plants in UK, Italy and Spain. To stay in front, we continually keep expanding ‘our manufacturing capabilities in more low cost region such as Romania, Taiwan, Malaysia etc. This low-cost manufacturing facilities enable us provide a flexible, scalable global system that delivers superior operational performance and optimal results for our customers. Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing, logistic services, and vertically integrated with our E commerce technologies, to optimize customer operations by lowering costs and reducing time to market. Caledonian & Addison has been respected for its high standards of quality, excellent service level, competitive pricing and a unique and innovative spirit. With our latest technologies, we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning, we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized, country and industry specific solutions. Caledonian & Addison has established an extensive network of design, manufacturing, and logistics facilities in the world’s major markets to serve the growing outsourcing needs of both multinational and regional customers. CONTENT TFOI (MTX) 3.6/6KV, 6/10KV, 8.7/15kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant MV Power Cables (Halogen Free Inner Covering) 5 TIO! (MTX) 3.6/6KV, 6/10kY, 8.7/15KV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant MV Power Cables (SHF1 Inner Sheath). eters UL OC ue eerie TI (MTX300) 0.6/1 kV XLPE Insulated, LSOH (SHF1) Sheathed Flame Retardant Power & Control Cables (Single Core)... TI (MTX400) 0.6/1 kV XLPE Insulated, LSOH (SHF1) Sheathed Flame Retardant Power & Control Cables (Multicore) .....e TOI (MTX300) 0.6/1 KV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Power & Control Cables (Single Core) 16 ‘TFOI (MTX400) 0.6/1 kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Power & Control Cables (Multicore) 18 RI (MTX300) 0.6/1 KV HEPR Insulated, LSOH (SHF1) Sheathed Flame Retardant Power & Control Cables (Single Core) 24 RI (MTX400) 0.6/1 KV HEPR Insulated, LSOH (SHF1) Sheathed Flame Retardant Power & Control 3 Cables (Multicore) «cree ROI (MTX300) 0.6/1 kV HEPR Insulated, LSOH (SHF1) Sheathed, Screened Flame Retardant Power & Control Cables (Single Core) .... RFOI (MTX400) 0.6/1 kV HEPR Insulated, LSOH (SHF1) Sheathed, Screened Flame Retardant Power & Control Cables (Multicore) 27 BI (MFX300) 0.6/1 kV Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed Fire Resistant Power & Control Cables (Single Core) ...... BI (MFX400) 0.6/1 kV Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed Fire Resistant Power & Control Cables (Multicore) 32 BOI (MFX300) 0.6/1 KV Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant Power & Control Cables (Single Core) 35 IEC Standard Caledonian Offshore & Marine Cables Content wa caledonan-eables,c0.UK BFOI (MFX400) 0.6/1 kV Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant Power & Control Cables (Multicore) 37 BO! (MFX300) 0.6/1 kV Fire Barriers + HEPR Insulated, LSOH (SHF1) Sheathed, Screened Fire Resistant Power & Control Cables (Single Core) 40 BFOI (MFX400) 0.6/1 KV Fire Barriers + HEPR Insulated, LSOH (SHF1) Sheathed, Screened Fire Resistant Power & Control Cables (Multicore) 42 (ies TI (MRE-2XH) 150/250V XLPE Insulated, LOH (SHF1) Sheathed Flame Retardant Instrumentation & Control Cables (Multicore)... 44 TIO! (MRE-2XCH) 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation & Control Cables (Multicore) .....:..seesees es AB TFOI (MRE-2XCH) 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation & Control Cables (Multipair/Mutitriple) 48 TIOI (MRE-2X(St)HCH) 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened & Armoured Flame Retardant Instrumentation & Control Cables (Multipair/Multtriple) 52 TI (MRE-2X(St)H) 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened Flame Retardant Instrumentation & Control Cables (Muttipair/Muttriple). 56 TI (MRE-2XH PiMF/TIMF) 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Individual Screened Flame Retardant Instrumentation & Control Cables (Multipait/Multitripe)..... TFOI (MRE-2XCH PiMF/TIMF) 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Individual Screened & Armoured Flame Retardant instrumentation & Control Cables (Multipair/Multitriple) ...63 ROI (MRE-3GCH) 150/250V HEPR Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation & Control Cables (Multipair) 67 BI (MRE-M2XH) 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed Fire Resistant Instrumentation & Control Cables (Multicore) 69 BFOI (MRE-M2X(St)CH) 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened & Armoured Fire Resistant Instrumentation & Control Cables (Multipair/Multtriple).. BI (MRE-M2X(St)H) 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened Fire Resistant Instrumentation & Control Cables (Multipair/Multitriple).......:.c:eseene 75 IEC Standard Caledonian Offshore & Marine Cables Content BI (MRE-M2XH PiMF/TIMF) 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Individual Screened Fire Resistant Instrumentation & Control Cables (Multipair/Muttitriple). 79 BFOI (MRE-M2XCH) 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Resistant Instrumentation & Control Cables (Multipair/Muttitriple) 82 BFOI (MRE-M2XCH PiMF/TIMF) 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Individual Screened & Armoured Fire Resistant Instrumentation & Control Cables (Multipair/ Muttitripte) BOI (MRE-M3GCH) 150/250V Mica Tape + HEPR Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant Instrumentation & Control Cables (Multipair) 90 Cat Se SIFTP 0.22mm*, 92 Mud Resistant Cat Se S/FTP 0.22mm# 94 Cat Se SF/UTP 24AWG 4P/8P 96 Armoured Cat Se SF/UTP 24AWG 98 Cat Se FJUTP 24AWG 400 Cat 6 U/FTP 23AWG 402 Armoured Cat 6 S/FTP 23AWG 404 Cat 6 SF/UTP 24AWG 4P/8P 106 Cat 7 SIFTP 0.27 mm? 108 Mud Resistant Cat 7 S/FTP 0.27 mm? 110 Cat 7 SIFTP 23AWG 4PI8P..... RG Series Coaxial Cables 50 0/75 © KX Series Coaxial Cables 50 9/75 2 PROFIBUS 1 Pair 22 AWG ..... Armoured PROFIBUS 1 Pair 22 AWG PROFIBUS 1 Pair 0,35mm........ IEC Standard Caledonian Offshore & Marine Cables Content wa caledonan-eables,c0.UK CAN BUS CABLES 1202 125 Breakout Fiber Cable. 127 Indoor Optical Fiber Cables with Central Strength 129 Tight Buffer Optical Fiber Cables... 131 Central Loose Tube Optical Fiber Cables. 133 Fire Resistant Central Loose Tube Optical Fiber Cables... 135 Caledonian Order Code 137 Power Copper Conductors According to IEC 60228. 141 Instrumentation & Control Conductors According to IEC 60092-376. 142 Current Ratings for Continuous Service (IEC 60092-352). 143 Short Circuit Current Ratings. 144 Reactance / Impedance 145 Voltage Drop (Cables Up to 1 KV) 146 Voltage Drop Coefficient 147 IEC Standard Caledonian Offshore & Marine Cables MariTox Marine Flame Retardant Mi TFOI (MTX) 3.6/6kV, 6/10kV, 8.7/15kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant MV Power Cables (Halogen Free Inner Covering) Application These armoured MV cables are used on board of ships in all locations for fixed installations complying with IEC standards 60092-352, These cables are flame retardant, low smoke & halogen free, Copper Wire Braid Armour Standards Halogen-tree Inner Covering Stranded Copper Conductor Conditor Sereen + IEC 60092-350/351/354/359 XUPE insulation + IEC 60332-1 Insulation Sereen © IEC 60332.3-22 Metalic Sereen LSOH(SHF*) Sheath © IEC 60754-1/2 + IEC 61034 Construction Conductors: Class 2 stranded copper conductor. Conductor Screen: Semi-conducting layer (tape/compound). Insulation: XLPE. Insulation Screen: Semi-conducting layer (tape/compound). Metallic Screen: Copper tape Inner Covering: Halogen free compound. Armour: Copper wire braid Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request. Core Identification Coloured tape shall be inserted under metallic screen. 3core: Red, Yellow, Blue. IEC Standard Caledonian Offshore & Marine Cables ye Retardant Medium Voltage Cables wa caledonan-eables,c0.UK Mechanical and Thermal Properties Bending Radius for Fixed Installations: 12 OD (single core); 9X OD (three core) Temperature Range: -30'C ~ +80°C Dimensions and Weight 3.6/6kV Construction Nominal Insulation Nominal Sheath Nominal Overall Nominal Part No. No. of coresxCross Thickness Thickness Diameter Weight section(mm) mm. mm. mm. ark MTX-3.6/6KV-RMZ1-1610 4x10 25 15 196 580 MTX-3.6/6KV-RMZ1-1C18 4x16 25 15 205 670 (MTX-3.6/6KV-RMZ1-1C25 1.25 25 15 218 800 MTX-3 6/6KV-RMZ1-1635 135, 25 16 23.2 940 MTX-3.6/6KV-RMZ1-1650 4x50 25 18 245 1100 MTX-3.6/6KV-RMZ1-1670 4x70 28 47 26.5 1380 (MTX-3.6/SKV-RMZ1-1C95 1x98 25 18 28.6 1700 MTX-3.6/6KV-RMZ1-16120 4120 25 19 30.4 2000 MTX-3.6/6KV-RMZ1-1C150 1x150 25 19 32.0 2320 MIX-3.6/6KV-RMZ1-1C185 1185 25 20 34.4 2770 MTX-3.6/6KV-RMZ1-16240 141x240 26 24 38.0 3530 (MTX-3.6/6KV-RMZ1-1C300 1300 28 23 412 4270 MTX-3.6/6KV-RMZ1~1C400 1400 3.0 24 456 5410 MTX-3.6/6KV-RMZ1-1C500 1500 32 25 43.9 6390 IMTX-3.6/6KV-RMZ1-1C630 1x60 32 27. 535 2020 MTX-3.6/6KV-RMZ1-3610 3x10 25 20 35.4 1620 MTX-3 6/6KV-RMZ1-3C16 3x16 25 22 38.4 2030 MTX-3 6/6KV-RWZ1-3625 3x25 25 23 a4 2870 MTX-3.6/6KV-RMZ1-3635 3x35 25 24 442 2930 (MTX-3.6/8KV-RMZ1-3C50 3x50 25 25 476 3510 MTX-3.6/6KV-RMZ1-3C70 3x70 25 27 519 4390 MTX-3.6/6KV-RMZ1-3C95 3x95 25 28 566 5470 MIX-3.6/6KV-RMZ1-36120 3x120 25 3.0 60.4 6450 MTX-3.6/6KV-RMZ1-36150 3x150 25 34 644 7490 MTX-3.6/6KV-RMZ1-36185 3x185 25 33 68.3 3850 MTX-3 6/6KV-RMZ1-3C240 3x240 26 35 75.4 11080 6/10kV Construction Nominal Insulation Nominal Sheath Nominal Overall Nominal Part No, No, of coresxCross Thickness. Thickness Diameter ‘Weight ‘section(mn?) mm mm mm kgikm MTX-6/10KV-RMZI-1016 1x16 34 18 25 750 MTX-S/10KV-RMZ1-1625 1x25 34 16 23.8 890 MTX-S/10KV-RMZ1-1635 4x35, 34 47 25,2 1040 MTX-B/1OKV-RMZ1-1050 1x50 34 47 265 1200 MariTox Marine Flame Retardant Mi Construction Nominal Insulation Nominal Sheath Nominal Overall Nominal Part No. No, of coresxCross Thickness Thickness Diameter ‘Weight ssection(mm?) mm mm mm kom MTX6/10KV-RMZ1-1670 4x70 34 18 28.5 1480 MTX-6/10KV-RMZ1-1C95, 1x95 34 19 308 1810 MTX-6/10KV-RMZ1-16120 1120 34. 19 32.2 2100 MTX-6/10KV-RMZ1-16150 4x150 34 20 344 2470 MTX-6/10KV-RMZ1-16185, 4x185 34 24 36.9 2980 IMTX-G/10KV-RMZ1-10240 1240 34 22 39.8 3650 MTX-B/T0KV-RMZ1-1300 1300 34. 23 42.4 4340 MTX-6/10KV-RMZ1=1400 141x400 34 25 465 5480 MTX-6/10KV-RMZ1-1C500 41%500 34 28 49.5 6430 MTX-G/0KV-RMZ1-10630 1x60 34 27. 53.9 040 MTX-BIOKV-RMZ1-3016 3x18 34 23 42.5 2330 MTX-6/10KV-RMZ1-3625 3x25. 34 24 459 2840 MTX-6/10KV-RMZ1-3635, 3x35, 34 28 48.7 3310 MTX-6/10KV-RMZ1-3050 3x50 34 27 519 3890 MTX-6/10KV-RMZ1-3C70 ‘3x70 34 28 56.4 4820 MTX-6/10KV-RMZ1-3C95 3x95, 34 30 508 5900 MTX-6/10KV-RMZ1-30120 3x120 34 3. 545, 6880 MIX-6/10KV-RMZ1-30150 3x150 34 33 68.3, 7960 MTX-6/10KV-RMZ1-30185 ax185 34 34 28 ‘9390 MTX-6/10KV-RMZ1-30240 3240 34 31 792 11570 8.7/15kV Construction | Nominal Insulation Nominal Sheath Nominal Overall Nominal Part No. No.ofcoresxCross Thickness Thickness Diameter ‘Weight section(mm’) mom. mm. mm ark MTX8.7/1SKV-RMZ1-1625, 1x25 45 ur 26.2 1020 IMTX-8,7/15KV-RMZ1-1635 1x35 45 18 278 1170 MTX-8.7/15KV-RMZ1-150 4x50 45 18 28.9 1340 MTX-8.7/18KV-RMZ1-1C70 4x70 45 19 309 1630 MTX-8.7/15KV-RMZ1-1C95 1x95 45 20 33.4 72000 MTX-8.7/15KV-RMZ1-16120 1x120 45 20 350 2300 MTX-8.7/15KV-RMZ1-1C150 1x150 45 24 373. 2730 MTX-8,7/15KV-RMZ1-1C185, 1x185 45 22 39.3, 3180 IMTX-8.7/15KV-RMZ1-16240 141x240 45 23 422 ‘3860 MTX-8.7/15KV-RMZ1-10300 1x30 45 24 452 4600 MTX-8.7/15KV-RMZ1-1C400 141x400 45 25 488 5680 MTX-8,7/15KV-RMZ1-1500 1500 45 27 519 6680 IMTX-8.7/1SKV-RMZ1-1C630 1630 45 28 567 8360 IMTX-8.7/1SKV-RMZ1-3025 3x25 45 26 510 3280 MTX-8.7/15KV-RMZ1-3C35 3x35. 45 27 538 3770 MTX-8.7/15KV-RMZ1-3C50 3x60 45 29 57.4 4430 MTX-8.7/15KV-RMZ1-3C70 3x70 45 3.0 615. 5340 MTX-8.7/15KV-RMZ1-3C95 3x95 45 32 66.0 6460 MTX-8.7/15KV-RMZ1-30120 3x120 45 33 698 7450 MTX-8.7/15KV-RMZ1-36150 3x150 45 35 739 8640 MIX-8,7/15KV-RMZ1-36185, 3x185 45 36 780 10040 MTX-8.7/15KV-RMZ1-30240 3x240 45 39 aaa 12270 IEC Standard Caledonian Offshore & Marine Cables ye Retardant Medium Voltage Cables DE TIOI (MTX) 3.6/6KV, 6/10kV, 8.7/15kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant MV Power Cables (SHF1 Inner Sheath) Application ‘These armoured MV cables are used on board of ships in all locations for fixed installations complying with IEC standards 60092-352. These cables are flame retardant, low smoke & halogen free. Standards CopperiGalvanized Stee! Wire Braid Armour + IEC 60092-350/351/354/359 LSOH(SHF1) Inner Sheath * IEC 60332-1 Stranded Copper Conductor Conductor Sereen + IEC 60332-3-22 XLPE insulation © IEC 60754-1/2 Insulation Sereen * 16061034 Metalic Seren LSOH(SHF1) Outer Sheath Construction Conductors: Class 2 stranded copper conductor. Conductor Screen: Semi-conducting layer (tape/compound). Insulation: XLPE. Insulation Screen: Semi-conducting layer (tape/compound). Metallic Screen: Copper tape Inner Sheath: LSOH (SHF1). Armour: Copper wire braid or galvanized steel wire braid Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request. Core Identification Coloured tape shall be inserted under metallic screen. 3core: Red, Yellow, Blue. Mechanical and Thermal Properties MariTox Marine Flame Retardant Mi Bending Radius for Fixed Installations: 12 OD (single core); 9 OD (three core) Temperature Range: -30' Dimensions and Weight 3.6/6kV. Part No. MTX-3.6/6KV-RZIMZ1-1610 MTX-3.6/6KV-RZ1MZ1-1C16 MTX-3,6/6KV-RZ1MZ1-1625 MIX-3.6/6KV-RZ1MZ1-1C35, MTX-3.6/6KV-RZ1MZ1-1C50 MIX-3.6/6KV-RZ1MZ1-1C70 MIX-3,6/6KV-RZ1MZ1-1C95 MTX-3.6/6KV-RZ1MZ1-16120 MTX-3.6/6KV-RZ1MZ1-16150 MTX-3.6/6KVERZIMZ1-16185 MTX-3.6/6KV-RZ1MZ1-16240 MTX-3.6/6KV-RZ1MZ1-16300 MTX-3.6/6KV-RZ1MZ1-16400 MTX-3.6/SKV-RZIMZ1-1C500 MTX-3.6/6KV-RZ1MZ1-16630 MIX-3.6/6KV-RZ1MZ1-3610 MIX-3.6/6KV-RZ1MZ1-3616 MTX-3.6/6KV-RZ1MZ1-3025 MIX-3.6/6KV-RZIMZ1-3635 MIX-3,6/6KV-RZ1MZ1-3C50 MTX-3.6/6KV-RZ1MZ1-3070 MTX-3.6/6KV-RZ1MZ1-3C95 MTX-3.6/6KVERZ1MZ1-36120 MTX-3.6/6KV-RZ1MZ1-36150 MTX-3.6/6KV-RZ1MZ1-36185 MTX-3.6/6KV-RZ1MZ1-36240 6/0kV Part No. MTX-6/10KV-RZIMZ1-1616 MTX-6/10KV-RZ1MZ1-1625 MIX-6/10KV-RZ1MZ1-1635 MTX-6/10KV-RZ1MZ1-1C50 MTX-6/10KV-RZ1MZ1-1670 MIX-6/10KV-RZ1MZ1-1695 MTX-6/10KV-RZ1MZ1-16120, MTX-6/T0KV-RZ1MZ1-1C150 MTX-6/10KV.-RZ1MZ1-1C 185, Construction No. of coresxCross section(rm) 1x10 1x16 1x25 1x35 1x60 1x70 1x95 4x120 1x150 1x185 1x240 1300 1400 1500 1630 3x10 3x16 3x25 3x35 3x60 3x70 3x95 3x120 3x150 3x185 3x240 Construction No, of coresxCross section (mm) 1x16 125 4x35, 1x50 1x70 195 4120 1150 1185 ~+80°C Nominal Insulation Thickness 25 25 25 25 25. 25 25 25 25 25 26 28 3.0 32 32 25 25 25 25 25 25 25 25 25 25 26 Nominal Insulation Thickness: mm 34 34 34 34 34 34 34 34 34 ‘Nominal Sheath Thickness Inner 13 13 14 14 15 16 16 AT 18 18 20 24 22 24 25 19 20 24 22 23 25 26 28 29 34 33 Nominal Sheath Thickness Inner 14 15 15 16 18 47 18 18 19 mm mm Outer 1.0 1.0 14 44 12 12 13 413 13 14 15. 16 AT AT 19 14 15 16 16 47 18 19 20 24 22 24 Outer uM 44 12 12 12 13 43 14 14 Nominal Overall Diameter 192 20.1 218 23.0 247 26.7 28.8 306 32.4 344 38.4 a6 45.8 493 54.1 36.3 388 420 448 48.0 525 57.0 61.0 54.9 59.3 76.4 Nominal Overall Diameter mm 2.3 23.8 25.2 26.7 28.5 30.8 326 344 36.9 Nominal Weight kam 560 650 800 940. 1120 1380 1720 2020 2350 2780 3580 4310 5440 8450 att0 1710 2020 2500 2950 3510 4420 5470 6480 7540 8940 11180 Nominal Weight kam 750 890 ‘4040 1220 1480 1830 2140 2470 2980 IEC Standard Caledonian Offshore & Marine Cables e Retardant Medium Voltage Cables wa caledonan-eables,c0.UK conser renee ‘Nominal Sheath Thickness nine Nominal Pate eee ae = Peere section(mm*) mm Inner Outer mm MIKSOKAEIMEISCSS ge sks 8.7/15kV mreon | Non st Sats Tues | SSS | Naa Pat = viet pce ae Dine | Oe section(mm*) mm Inner Outer mm a Minasnsevaeinet toro (wie) 4s |stats Miesmewacwersce | posts bate | a uixamaceazinet sco se) asses oa IEC Standard Caledonian Offshore & Marine Cables MariTox Marine Flame Retardant P TI(MTX300) 0.6/1 kV XLPE Insulated, LSOH (SHF1) Sheathed Flame Retardant Power & Control Cables (Single Core) Application ‘These unarmoured power & control cables are used on board of ships in all locations for fixed installations not subject to mechanical risk complying with IEC standards 6092-352. These cables are flame retardant, low smoke & halogen free. Standards IEC 60092-350/351/353/359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1/2 IEC 61034 Stranded Copper Conductor XLPE Insulation LSOH (SHF1) Sheath Construction * Conductors: Class 2 stranded copper conductor, round or sector shaped. Class 5 stranded conductors can be offered upon request. + Insulation: XLPE. + Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request. Core Identification ‘+ Single core: Black Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6 x OD (OD>25mm); 4X OD (OD <25mm) ‘Temperature Range: -30°C ~ +80°C ‘woraaddson-cables.com — ADDISON IEC Standard Caledonian Offshore & Marine Cables MariTox Marine Flame Retardant Power & Control Cables DE Dimensions and Weight MTX300 1RZ1-R Single Core 0.6/1kV (-R stands for class 2 conductor. For class 5 conductor, please change -R to -F) Construction Nominal Insulation Nominal Sheath Nominal Overall Nominal Part No, No.of coresxCross Thickness Thickness Diameter ‘Weight section(mm’) mm. mom. mm. kfm MTX300-1RZT-R-1C1.5 115 o7 1.0 5.0 40 MTX300-1RZ1-R-102.5, 102.5 o7 1.0 54 50 MIX300-1RZ1-R-1C4 7 09 1.04 84 70 MTX300-1RZI-R-108 1x6 09 1.04 70 20 MTX300-1RZ1-R-1C10 10 og 1.04 79 430 MIX300-1RZ1-R-1616 16 09 1.04 89 190 MTX300-1RZ1-R-1625 Das 09 uM 10.4 295 MTX300-1RZ1-R-1635 1x35, 09 44 17 380 MTX300-1RZ1-R-1C50 150 1.0 12 133 510 MTX300-1RZ1-R-1C70 1x70 1 43 185 0 MTX300-1R21-R-1C95 1x95, 44 43 17.4 970 MTX300-1RZ1-R-16120 1120 12 14 194 1220 MIX300-1RZ1-R-16150 1x160 14 15 215 1505 MITX300-1RZ1-R-1C185 1185 16 15 23.8 1865 MTx300-1RZ1-R-16240 13240 47 16 287 2420 MIx300-1RZ1-R-1C300 +1300 18 47 296 3015 (Cia nov1son wonton IEC Standard Caledonian Offshore & Marine Cables MariTox Marine Flame Retardant P TI (MTX400) 0.6/1 kV XLPE Insulated, LSOH (SHF1) Sheathed Flame Retardant Power & Control Cables (Multicore) Application ‘These unarmoured power & control cables are used on board of ships in all locations for fixed installations not subject to mechanical risk complying with IEC standards 6092-352. These cables are flame retardant, low smoke & halogen free. Standards IEC 60092-350/351/353/359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1/2 IEC 61034 Stranded Copper Conductor XLPE Insulation LSOH (SHF1) Sheath Construction * Conductors: Class 2 stranded copper conductor, round or sector shaped. Class 5 stranded conductors can be offered upon request. + Insulation: XLPE. * Filler (optional): Halogen free filling compound. + Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request Core Identification Two cores: Blue, Brown. Three cores: Brown, Black, Grey. Four cores: Blue, Brown, Black, Grey. Five cores: Blue, Brown, Black, Grey, Black. Multi cores: White with black numbers. With yellow/green (optional) ‘Two cores + earth (3G): Yellow/green, Blue, Brown. Three cores + earth (4G): Yellow/green, Brown, Black, Grey. Four cores + earth (5G): Yellow/green, Blue, Brown, Black, Grey. IEC Standard Caledonian Offshore & Marine Cables ie Retardant Power & Control Cables wa caledonan-eables,c0.UK Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6 x OD (OD>25mm); 4x OD (OD <25mm) ‘Temperature Range: -30°C ~ +80°C Dimensions and Weight MTX400 1RZ1-R Multicore 0.6/1kV (-R stands for class 2 conductor. For class 5 conductor, please change -R to -F) constuction Nominal | Nominal | Nominal | PartNo No, ofcoresxCross(msulaton Sheath Overall Weight Thickness Thickness Diametor section(mn?) im nm ae kg/km MIX400-18Z1-R-2C1.5 2x15 07 14 84 80 MTX400-4RZ1-R-202.5 2x25 07 14 92 100 MTX400-1RZ1-R-204 2x4 09 14 WA 135 MTx400-1RZ1-R-2C8 26 09 12 124 185 MIX400-1RZ1-R-2C10 2x10 oo 12 144 270 MIXA00-1RZ1-R-2C18 2x16 09 13 164 400 MTX400-1RZ1-R-2625 2x25 08 13 188 700 MTX400-1RZ1-R-2C35 2x35 oo 13 214 930 MTx400-1RZ1-R-2C50 2x50 10 13 242 1200 MTX400-1RZ1-R-SC1.5(361.5) 3x(@)15 07 44 88 100 MTxA00-121-R-302.5(362.5) 3x(6)25 07 44 98 430 MTXx400-1RZ1-R-3C4(364) ax(G 08 12 120 190 MTXx400-1RZ1-R-3C6(365) 3x(6)6 os 12 132 250 MTx400-1821-R-3C10 3x10 09 13 152 380 MTX400-1RZT-R-SC16(3616) 3x16 09 13 175 560 MTX400-1RZ1-R-3C25 3x25 oo 15 20.7 875 MTX400-1RZ1-R-3C35 3x35 09 18 238 1220 MTX400-1RZ1-R-3C35S 3x35 (sector shaped) 09 15 20.41 1135 MTX400-1R21-R-3C50 3x50 10 47 28.7 1780 MTX400-1RZ1-R-3C50S 3x50 (sector shaped) 10 17 28 1530 MTX400-1RZ1-R-3C70S ‘3X70 (Sector shaped) 44 18 287 2150 MTX400-1R21-R-3C95S. ‘3x95 (sector shaped) 44 19 30.2, 2900 MTX400-1RZ1-R-361208 3x120(sector shaped) | 1.2 24 340 3675 MTX400-1RZ1-R-AC1.5(4G1 5) 4x(6)15 07 14 96 120 MTX400-18Z1-R-4C2.5(462.5) 4x(6)25 07 14 10.7 165 MTX400-1RZ-R-ACA(AG4) 4x(@)4 os 12 132 240 MTX400-18Z1-R-4C8(45) 4x(G)6 os 12 145 320 MTX400-18Z1-R-AC10(6610) 4x(6)10 08 13 167 490 Ce aovison —msstinstn con IEC Standard Caledonian Offshore & Marine Cables MariTox Marine Flame Retardant Power & Control Cables coma ermal tenn sce" Tides imme Our F wmussornescen A0D150N 15) IEC Standard Caledonian Offshore & Marine Cables ie Retardant Power & Control Cables DE TOI (MTX300) 0.6/1 kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Power & Control Cables (Single Core) Application These armoured cables are used on board of ships in all locations for fixed installations where cable protection is required. These cables are flame retardant, low smoke & halogen free Standards IEC 60092-350/361/353/359 Standed Copper Condicior IEC 60332-1 IEC 60332-3-22 IEC 60754-1/2 IEC 61034 XLPE Insulation Copper Wire Braid Armour LSOH (SHF1) Sheath Construction * Conductors: Class 2 stranded copper conductor, round or sector shaped. Class § stranded conductors can be offered upon request. + Insulation: XLPE. + Armour: Copper wire braid. * Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request. Core Identification * Single core: Black Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6X OD ‘Temperature Range: -30°C ~ +80°C Dimensions and Weight MTX300 1RMZ1-R Single Core Armoured 0.6/1kV (-R stands for class 2 conducto1 For class 5 conductor, please change -R to -F) Construction Nominal Insulation Nominal Sheath Nominal Overall, Nominal PartNo. No, of coresxCross Thickness Thickness Diameter ‘Weight section(mm?) mom. mm mm korkm MTX300-1RMZ1-R-161.5 1x15 o7 14 63 70 MTX300-1RMZ1-R-162.5, 1x25 o7 rr a7 80 MTX300-1RMZ1-R-1C4 1x4 09 14 14 400 MTX300-1RMZ1-R-1C8 166 09 14 30 120 MTX300-1RMZ1-R-1C10 1x10 09 14 38 180 MIX300-1RMZ1-R-1616 1x16 09 14 102 248 MTX300-1RMZ1-R-1625 1025 09 12 7 355 MTX300-1RMZ1-R-1C35 1635, 09 12 130 455 MIX300-1RMZ1-R-1C50 1x50 1.0 13 150 620 MTX300-1RMZ1-R-1670 1x70 1 14 172 850 MTX300-1RMZ1-R-1C95 1x95, 44 14 194 115 MTX300-1RMZ1-R-16120 4x120 42 15 aia 1385 MTX300-1RMZ1-R-16150 4180 14 18 23.2 1680 MTX300-1RMZ1-R-16185 14185 16 16 255 2065 MTX300-1RMZ1-R-16240 15240 47 17 28.4 2640 MTX300-1RMZ1-R-16300 41300 18 18 313 3260 IEC Standard Caledonian Offshore & Marine Cables ie Retardant Power & Control Cables DE TFOI (MTX400) 0.6/1 kV XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Power & Control Cables (Multicore) Application These armoured cables are used on board of ships in all locations for fixed installations where cable protection is required. These cables are flame retardant, low smoke & halogen free. Standards Stranded Copper Conductor + IEC 60092-350/351/353/359 XLPE Insulation « IEC 60332-1 Copper Wire Braid Armour + IEC 60332-3-22 LSOH (SHF1) Sheath © IEC 60754-1/2 * IEC 61034 Construction * Conductors: Class 2 stranded copper conductor, round or sector shaped. Class 5 stranded conductors can be offered upon request. + Insulation: XLPE. + Inner Covering: Lapping. Armour: Copper wire braid. * Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request. Core Identification ‘Two cores: Blue, Brown. Three cores: Brown, Black, Grey. Four cores: Blue, Brown, Black, Grey. Five cores: Blue, Brown, Black, Grey, Black. Multi cores: White with black numbers. With yellow/green (optional) ‘Two cores + earth (3G): Yellow/green, Blue, Brown. Three cores + earth (4G): Yellow/green, Brown, Black, Grey. Four cores + earth (5G): Yellow/green, Blue, Brown, Black, Grey. Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6x OD Temperature Range: -30°C ~ +80°C Dimensions and Weight MTX400 1RMZ1-R Multicore Armoured 0.6/1kV (-R stands for class 2 conductor. For class 5 conductor, please change -R to -F) Nominal Nominal Nominal Consirucion Insulation Sheath Overat Nominal Part No. No.of coresxCross Tees Demeter Weit section(mnm’) im om mm kgm MTX400-1RMZ1-R-2615 2x15 07 14 93 120 MTX400-1RMZ1-R-262.5 2x25 07 14 104 150 MTX400-1RMZ1-R-2C4 2x4 09 12 122 195 MTX400-1RMZ1-R-265 2x6 09 12 137 275 MTX400-1RMZ1-R-2610 2x10 09 13 187 385 MTXA00-1RMZ1-R-2C16 2x16 09 14 184 595 MTX400-1RMZ1-R-2625 2x25 09 15 213 820 MTX400-1RMZ1-R-2035 2x35 09 15 239) 1140 MTX400-1RMZ1-R-2C50 2x50 1.0 15 28.7 1500 MTX400-1RMZ1-R-8C1.5(3G1 5) 3x(G)1.5 07 14 98 145 MTXA00-1RMZ1-R-362.5(362.5) 3x(9)25 07 it 107 180 MTX400-1RMZ1-R-3C4 3x4 09 12 128 245 MTX400-1RMZ1-R-3C5 3x6 09 13 147 345 MTXA00-1RMZ1-R-3C10 3x10 09 13 168 490 MTX400-1RMZ1-R-3C18 3x16 09 14 195 755 MTX400-1RMZ1-R-SC25 3x25 09 18 227 1095 MTX400-1RMZ1-R-3C35 3x35 09 18 249 1340 MTX400-1RMZ1-R-3C35S 3x35 (sector shaped) 09 18 20 1320 MTX400-1RMZ1-R-3C5O 3x50 10 16 at4 1750 MTx400-1RMZ1-R-3C50S ‘3x0 (sector shaped) 10 18 248 1820 MTX400-1RMZ1-R-3C70S 3x70 (sector shaped) 44 20 297 2575 MTX400-1RMZ1-R-3COS 3x95 (sector shaped) rr 2A 33.4 3435 MTX400-1RMZ1-R-SC1208 __—3x120 (sector shaped) 1.2 22 36.0 4070 MTX400-1RMZ1-R-SC150S 3180 (Sector shaped) 1.4 24 409 5435 MTX400-1RMZ1-R-4C1.5(4G1.5) 4x(G)1.5 07 14 105 170 MTX400-1RMZ1-R-4C2.5(4G2 5) 4x(G)25 07 12 18 225 IEC Standard Caledonian Offshore & Marine Cables ie Retardant Power & Control Cables wa caledonan-eables,c0.UK Construction Nominal PartNo No.ofcoresxcross sujaton Sheath vera eight secton(mn) si “ne me ahkm MTXA00-4RMZI-R-CA axa 09 13 147 395 MTX400-4RMZ1-R-4C6 4x6 09 13 160 225 MIXA00-ARMZ1-RACIO 4x10 09 14 183 228 MTXA00-RMZI-R4C16 4x16 09 18 215 998 MTX400-1RMZ1-R4C25 4x25 09 16 244 1345 MIX400-1RMZ1-R4C95 4x95 09 47 278 176 MTX400-1RMZ1-R4C35S 4x35 (secor shaped) | 08 47 243 1700 MTX400-1RMZ1-R-4C50 4x60 10 16 23.9 400 MTXA00-1RMZ1-R-4C50S 4x50(sector shaped) 1.0 16 273 2300 MTX400-RMZ1-R4C70S 4x70(sector shaped) | 1.4 24 328 260 MTX400-1RMZ1-R4C95S 4x95(sector shaped) 1.1 22 373 4390 MTXAOO-ARMZI-RSCI.5(5G15)_Sx(G)15 07 12 17 208 MTX400-ARMZ1-R5C2.5(562.5) __5x(G)25 07 42 128 265 MTXA00-ARMZI-R-5C4 564 09 12 152 360 MTXA00ARMZ1-RC1S oxi. 07 12 127 240 MTXAO0ARMZI-R-7C15 Tt.5 07 42 127 260 MTXA00-ARMZ1-R-C1.5 exis 07 12 155 40 MTXA004RMZ1-R-1001.5 0x1 07 13 162 380 MIXA00ARMZ1-R-12C1.5 12x15 07 14 169 440 MTXA00-RMZI-RI6C1S 16x15 07 14 188 550 MTXA00ARMZ1-R-19C1.5 19x15 07 15 197 620 MIXA00ARMZ1-R-24C1.5 24x15 o7 16 29 00 MTXA00-4RMZ1-R-6C2.5 5x25 07 12 129 290 MTXA004RMZ1-R-7625 7325 07 42 148 300 MTXA00-RMZ1-R1202.5 12128 07 14 187 610 MTXA004RMZ1-R-19C2.5 19x25 07 15 218 70 MTXA00ARMZ1-R-24C2.5 24x05 07 16 258 1100 MTXA00-RMZI-R27C2.5 27x25 07 47 25.4 1200 MTXA00ARMZ1-R97C2.5 37x25 07 19 292 1560 IEC Standard Caledonian Offshore & Marine Cables MariTox Marine Flame Retardant P RI (MTX300) 0.6/1 kV HEPR Insulated, LSOH (SHF1) Sheathed Flame Retardant Power & Control Cables (Single Core) Application These cables are used for fixed installations on ships and offshore units in all locations. These cables are flame retardant, low smoke & halogen free. Standards DIN 89160/98 IEC 60092-353 4> Stranded Copper Conductor IEC 60332-1 ¢ IEC 60332-3-22 i IEC 60754-1/2 SE LSOH (SHF1) Sheath IEC 61034 a HEPR Insulation Construction * Conductors: Class 2 stranded copper conductor. + Insulation: HEPR. * Outer Sheath: LSOH (SHF1). Core Identification Single core: Natural colour (beige). Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6 OD (OD>25mm); 4x OD (OD <25mm) Temperature Range: -20°C ~ +75'C (E& IEC Standard Caledonian Offshore & Marine Cables \ y/) MariTox Marine Flame Retardant Power & Control Cables Dimensions and Weight Construction Nominal Insulation Nominal Sheath Nominal Overall Nominal PartNo, No, of coresxCross Thickness Thickness Diameter ‘Weight section(mm) mm. mm. mm gtk MTX300-16721-R-1C4 1x4 o7 42 65 80 MTX300-1G721-R-1C8 16 o7 42 18 110 MTX300-1G7Z1-R-1C10 1x10 o7 42 as 150 MTX300-1G721-R-1C16 1x16 07 12 95 220 MTX300-4G721-R-41C25 1x25 09 12 110 320 MTX300-1G721-R-1C35 1x38 09 42 120 420 MTx300-16721-R-1650 1x50 1.0 13 138, 560 MTX300-167Z1-R-1670 1x70 14 13 155 780 MTx300-16721-R-1C95 1x95 14 14 78 +1030 MTX300-16721-R-16120 1x120 42 14 193 1290 MTX300-1672Z1-R-16150 1180 14 15 213 1580 MTX300-16721-R-1C185 1185 16 15 235 1960 MTX300-167Z1-R-16240 1240 17. 16 285 2560 MTx300-16721-R-16300 41300 18 47 295 3200 C2 Apvison —weusssentercm IEC Standard Caledonian Offshore & Marine Cables MariTox Marine Flame Retardant P RI (MTX400) 0.6/1 kV HEPR Insulated, LSOH (SHF1) Sheathed Flame Retardant Power & Control Cables (Multicore) Application These cables are used for fixed installations on ships and offshore units in all locations. These cables are flame retardant, low smoke & halogen free. Standards DIN 89160/98 IEC 60092-353 IEC 60332-1 IEC 60332-3-22 IEC 60754-1/2 IEC 61034 ‘Stranded Copper Conductor HEPR Insulation LSOH (SHF1) Sheath Construction * Conductors: Class 2 stranded copper conductor. + Insulation: HEPR. * Outer Sheath: LSOH (SHF1). Core Identification Two cores: Black, Blue. Three cores: Black, Blue, Brown. Four cores: Black, Blue, Brown, Black. Five cores: Black, Blue, Brown, Black, Black. Multi cores: All cores natural coloured, printed with numbers, starting in center with number 1 Cables with 3 cores and more also with green/yellow core (has to be stated in order). Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6X OD (OD>25mm); 4x OD (OD <25mm) Temperature Range: -20°C ~ +75°C IEC Standard Caledonian Offshore & Marine Cables ie Retardant Power & Control Cables wa caledonan-eables,c0.UK Dimensions and Weight Construction Nominal insulation Nominal Sheath Nominal Overall Nominal Part No. No. ofcoresxGross Thickness -—«Thickness.«=—=—_—Diameter Weight section(mm?) mm mm mm karen 2x15 07 19 a4 130 2x25 07 14 93 170 2x4 oz 14 108 220 2x8 07 12 118 280 2x10 7 12 138 410 MTX400-16721-R-2616 2x16 or 13 462 590 MTX400-16721-R-2625 2x25 os 15 20.4 880 MTX400-16721-R-3C1.5 3x15 07 44 88 160 MIX400-16721-R-302.5 3x25 o7 44 28 210 MTX400-16721-R-304 3x4 7 14 4 270 3x6 o7 12 126 350 3x10 oz 13 148 510 MTX400-16721-R-3016 3x16 7 14 173 750 MIX400-16721-R-3025 3x25 os 15 215 1130 MTX400-16721-R-3C35 3x35 os 16 242 1500 MTX400-16721-R-3C50 3x50 10. 18 285, 1970 MTX400-16721-R-3C70 3x70 44 20 229 2770 MTX400-16721-R-3C95 3x95 44 24 374 3680 MTX400-16721-R-30120 3x120 12 23 418 4580 MTX400-167Z1-R-4C1.5 4x15 oz 14 98 200 MTX400-1G7Z1-R-4C2.5 4x25 oz 1a 108 250 MTX400-16721-R-404 4x4 07 12 123 330 MTX400-16721-R-4C8 4x6 oz 12 138 440 MTX400-16721.-R-4C10 4x10 oz 13 163 660 MTX400-16721-R-4C16 4x16 oz 14 192 950 MTX400-16721-R-4025 4x25 os 16 239 1460 MTX400-16721-R-4C35, 4x35 os 17 270 1920 MTX400-16721-ReAC50 4x50 10. 13 305, 2520 MTX400-167214 4x70 44 24 367, 3530 MIxA00-167214 4x95 44 23. a7 4730. MTx400-16721 4 5x15 07 44 123 230 MTx400-16721 4 5x25 o7 12 133 300 MTx400-167214 7x15 oz 12 133 290 MTx400-167214 10x15 07 43. 158 360 MTx400-167214 12x15 07 13. 163 410 MTx400-16721-4 14x15 or 14 170 470 MTx400-16721- 16x15 oz 14 180 530 MTx400-167214 19x15 07 14 19.0 610 MTx400-167214 24x15 o7 15. 220 760 Ge aov1son —msstinstn con IEC Standard Caledonian Offshore & Marine Cables MariTox Marine Flame Retardant P ROI (MTX300) 0.6/1 kV HEPR Insulated, LSOH (SHF1) Sheathed, Screened Flame Retardant Power & Control Cables (Single Core) Application ‘These cables are used for fixed installations on ships and offshore units in all locations and on open deck. The good screening qualities of the copper braid also reduce radio interference and electrical influences to electronics installations. These cables are flame retardant, low smoke & halogen free Standards * DIN 89160/98 - Stranded Copper Conductor + IEC 6092-353 HEPR insulation + IEC 60332-1 Copper Wire Braid Seresn + IEC 60332-3-22 * 1C60764-172 LSOH (SHF 1) Sheath + IEC 61034 Construction * Conductors: Class 2 stranded copper conductor. + Insulation: HEPR. * Overall Screen: Copper wire braid * Outer Sheath: LSOH (SHF1). Core Identification Single core: Natural colour (beige). Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6 OD ‘Temperature Range: -20°C ~ +75°C IEC Standard Caledonian Offshore & Marine Cables ie Retardant Power & Control Cables wa caledonan-eables,c0.UK Dimensions and Weight Construction Nominal insulation Nominal Sheath Nominal Overall Nominal PartNo, No, ofcoresxCross Thickness Thickness Diameter Weight ssection(mm) mm mm mm. gym MTX300-1G7MZ1-R-1C4 1x4 07 12 73 110 MTX300-1G7MZ1-R-1C8 1x6 oz 12 33 140 MTX300-1G7MZ1-R-1C10 1x10 o7 12 93 190 MTX300-1G7MZ1-R-1C16 1x16 07 12 103 270 MTX300-1G7MZ1-R-1625 1025 os 12 123 380 MTX300-1G7MZ1-R-1C35 1x35, og 12 133 480 MTX300-167MZ1-R-1C50 1x50 10 13 153 650 MTX300-1G7MZ1-R-1670 1x70 14 14 173 900 MTX300-1G7MZ1-R-1C95 1x95 14 14 195 1170 MTX300-167MZ1-R-16120 1120 12 15 210 1410 MTX300-167MZ1-R-16150 1180 14 18 28 1750 MTX300-167MZ1-R-1C185 14185 16 18 248 2160 MTX300-167MZ1-R-16240 1240 17 47 278 2770 MTx300-167MZ1-R-1C300 4300 18 18 30.3 3440 IEC Standard Caledonian Offshore & Marine Cables MariTox Marine Flame Retardant P RFOI (MTX400) 0.6/1 kV HEPR Insulated, LSOH (SHF1) Sheathed, Screened Flame Retardant Power & Control Cables (Multicore) Application These cables are used for fixed installations on ships and offshore units in all locations and on open deck, The good screening qualities of the copper braid also reduce radio interference and electrical influences to electronics installations. These cables are flame retardant, low smoke & halogen free. Standards Stranded Copper Conductor HEPR Insulation Lapping/Extruded Filler Copper Wire Braid Screen LSOH (SHF1) Sheath DIN 89160/98 IEC 60092-353 IEC 60332-1 IEC 60332-3-22 IEC 60754-1/2 IEC 61034 Construction Conductors: Class 2 stranded copper conductor. Insulation: HEPR. Inner Covering: Lapping or extruded filler. Overall Screen: Copper wire braid. Outer Sheath: LSOH (SHF 1) Core Identification Two cores: Black, Blue. Three cores: Black, Blue, Brown. Four cores: Black, Blue, Brown, Black. Five cores: Black, Blue, Brown, Black, Black Multi cores: All cores natural coloured, printed with numbers, starting in center with number 1 Cables with 3 cores and more also with green/yellow core (has to be stated in order). IEC Standard Caledonian Offshore & Marine Cables ie Retardant Power & Control Cables wa caledonan-eables,c0.UK Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6x OD ‘Temperature Range: -20°C ~ +75°C Dimensions and Weight Construction Nominal Insulation Nominal Sheath Nominal Overall PartNo Ne cteteexioe]Thktess | | Thiktwes | Danwir | | "erat section(mm?) mm mm mm. oKm maonsomenacts at a7 2 ns 120 maon-cmiasnaces mas a7 12 waa 20 ixaon-1cmzisace at a7 is tea 0 uurxaoosemi.t-ace axe 07 ts 183 220 iimon-crizinacto_ext0 07 rr 0 500 iimcon-icmizisnacts 2x8 07 1s tes no warxaooiemieaces as 08 ts 0 ‘020 Mmaon-ommeisnacts ats a7 re na 210 umaon-omzinacas a8 a7 2 tee 220 iaoaoo-cruzsace ot 07 ts ‘a8 220 iaxaon-tarzi-ace x 07 ia is8 450 hinann-ioruzinacto auto 07 a 120 &2o henaon-cruzisacts—_—_exte o7 ts as a0 hancon-icTnzisnaces a8 08 ur ae tax hunewooiemisaces as 08 ts 288 te30 heroneornzisacso x80 1 ai 28 ata0 haan icmuzisnacro #470 ut 20 ue soz lenaonscrizsnaces 2x86 us 28 waa _050 hancon-icmuzistacreo | axta0 ta 25 #3 son haraeo-iomuzinacts act a7 12 tea 20 linaonsorizsaces a8 07 3 as 200 haxann-1aTnzis-ace ot a7 ta iss 420 werxaoo-temace 8 07 ta 0 540 hinaon-crizinacto auto a7 1s tes a0 hinann-igmizinacts—ext8 a7 is 23 tow werxaootemnisaces ans 08 ts asa ‘ew Mnann-GTuZi.R4ces ant 03 is 20 a0 hanann-igruzisn40s0 x80 1 20 so a180 hnaon-cmizisacro 6x70 ra 23 ase 2000 Minann-aTiZi.R4ces en ut 25 a si30 IEC Standard Caledonian Offshore & Marine Cables MariTox Marine Flame Retardai Construction Nominal Insulation Nominal Sheath Nominal Overall Nominal Weight Part No. No.of coresxCross Thickness Thickness meter eon ssection(mm?) mm mm. mm MTX400-1G7MZ1-R-5C1.5 5x15 o7 13 133 290 MTX400-1G7MZ1-R-5C2.5 5x25 oz 13 153, 400 MTX400-1G7MZ1-R-7C1.5 1x15 o7 13 143 380 MTX400-167MZ1-R-1061.5 10x15 o7 13 170 480 MIX400-1G7MZ1-R-1261.5 12x15 oz 14 180 500 MTX400-1G7MZ1-R-1401.5 14x15 oz 14 185 560 MTX400-1G7MZ1-R-16C1.5 16x15 o7 14 198 630 MIX400-1G7MZ1-R-19C1.5 19x15 o7 15 205 710 MTX400-1G7MZ1-R-2401.5 24x15 07 18 240 880 cmvstinctan AON 2B IEC Standard Caledonian Offshore & Marine Cables Resistant Power & Control Cables DE BI (MFX300) 0.6/1 kV Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed Fire Resistant Power & Control Cables (Single Core) Application ‘These unarmoured fire resistant cables are used on board of ships in all locations for fixed installations where cable protection is not required. These cables are fire resistant, flame retardant, low smoke & halogen free. Standards IEC 60092-350/351/353/359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1/2 IEC 61034 Stranded Copper Conductor Mica Tape + XLPE Insulation LSOH (SHF1) Sheath Construction * Conductors: Class 2 stranded copper conductor. Class 5 stranded conductors can be offered upon request. + Insulation: Mica tape + XLPE. * Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request. Core Identification Single core: Black. Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6x OD (OD>25mm); 4 OD (OD <25mm) ‘Temperature Range: -30°C ~ +80°C IEC Standard Caledonian Offshore & Marine Cables MariFlex Marine Fire Resistant Power & Control Cables Dimensions and Weight MFX300 1mRZ1-R Single Core 0,6/1kV (-R stands for class 2 conductor. For class 5 conductor, please change -R to -F) Construction Nominal Insulation Nominal Sheath Nominal Overall Nominal Part No. No, of coresxCross Thickness Thickness Diameter Weight section(mn) mom. mm mom. kik MFX300-1mRZ1-R-1625 1025 09 4 10.7 310 MFX300-1mRZ1-R-1635 1x35 09 14 120 410 MFX300-1mRZ1-R-1C50 4x50 10 42 136 560 MFX300-1mRZ1-R-1670 1x70 14 13 168 780 MFX300-1mRZ1-R-1C95 1x95 14 13 a7 1030 MFX300-1mRZ1-R-16120 4x120 42 14 19.7 1290 mssoraescen 2001508 35) IEC Standard Caledonian Offshore & Marine Cables Resistant Power & Control Cables DE BI (MFX400) 0.6/1 kV Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed Fire Resistant Power & Control Cables (Multicore) Application ‘These unarmoured fire resistant cables are used on board of ships in all locations for fixed installations where cable protection is not required. These cables are fire resistant, flame retardant, low smoke & halogen free. Standards IEC 60092-350/351/353/359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1/2 IEC 61034 Stranded Copper Conductor Mica Tape + XLPE Insulation LSOH (SHF1) Sheath Construction * Conductors: Class 2 stranded copper conductor. Class 5 stranded conductors can be offered upon request. + Insulation: Mica tape + XLPE. ‘+ Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request. Core Identification ‘Two cores: Blue, Brown Three cores: Brown, Black, Grey. Four cores: Blue, Brown, Black, Grey. Five cores: Blue, Brown, Black, Grey, Black Multi cores: White with black numbers. Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6 X OD (OD>25mm); 4X OD (OD <25mm) ‘Temperature Range: -30°C ~ +80°C Dimensions and Weight MFX400 1mRZ1-R Multicore 0.6/1kV (-R stands for class 2 conductor. For class 5 conductor, please change -R to -F) Construction Part No. No, of coresxCross, ssection(mm?) MFX400-1mRZ1-R-261.5, 2x15 MFX400-1mRZ1-R-262.5, 2x25 MFX400-1mRZ1-R-2C4 2x4 MFX400-1mRZ1-R-268 2x6 MFX400-1mRZ1-R-2C10 2x10 MEX400-1mRZ1-R-2616 2x16 MFX400-1mRZ1-R-2625 2x25 MFX400-1mRZ1-R-2635 2x35 MEX400-1mRZ1-R-2C50 2x50 MFX400-1mRZ1-R-3C1.5, 3x15 MFX400-1mRZ1-R-3C2.5 3x25 MEX400-ImRZ1-R-3C4 3x4 MFX400-1mRZ1-R-3C8 3x6 MEX400-1mRZ1-R-3C10 3x10 MFX400-1mRZ1-R-3C16 3x16 MFX400-1mRZ1-R-2625 3x25 MFX400-1mRZ1-R-3C35 3x35, MFX400-1mRZ1-R-3C50 3x50 MFX400-1mRZ1-R-2C70 9x70 MEX400-1mRZ1-R-3C70S__ 3x70 (sector shaped) MFX400-1mRZ1-R-3695 3x95 MEX400-1mRZ1-R-SC9BS 3x95 (Sector shaped) MFX400-1mRZ1-R-36120 3x120 MFX400-1mRZ1-R-3C1208 | 3x120 (sector shaped) MEX400-1mRZ1-R-4C1.5 4x15 MFX400-1mRZ1-R-402.5 425 MFX400-1mRZ1-R-4C4 axa MFX400-1mRZ1-R-408 4x6 mm oz oz oo 09 os 09 og oe 10 07 07 09 09 09 09 09 09 10 14 14 14 14 12 12 o7 07 09 09 Nominal Insulation Nominal Sheath Nominal Overall Nominal Thickness Thickness Diameter Weight mm. mm kak M4 85 85 1 95 110 414 W7 140 12 130 230 42 147 330 13 17.0 490 13 195 750 15 22.0 290 15 248 1340 1M 95 105 14 10.9 145 12 127 205 42 139 270 13 15.9 400 13 184 610 15 214 20 16 242 1330 47 275 1830 18 32.0 2570 18 275 2370 19 36.4 3380 19 3t4 3130 24 407 4180 24 34.4 3930 14 10.0 135 1 12 180 42 139 260 42 152 350 IEC Standard Caledonian Offshore & Marine Cables Power & Control Cables Construction Nominal Insulation Nominal Sheath Nominal Overall Nominal Part No, No.ofcoresxGross Thickness -—»«Thickness--=—_—Diameter ‘Weight section(mm) mm mm mm kghkm MFX400-1mRZ1-R-4C10 4x10 09 13 174 530 MEX400-1mRZ1-R-4C16 4x16 0.9 14 20.2 800 MFX400-1mRZ1-R-4C25 4x25 09 15 235 1230 MFX400-1mRZ1-R-4C35 4x35 09 17 26.7 1650 MEX400-1mRZ1-R-5C1.5 5x15. or 14 11.0 170 MFX400-1mRZ1-R-701.5 1x15 o7 12 128 210 MFX400-mRZ1-R-1201.5 12x15 o7 13 165 350 MPX400-1mRZ1-R-19C1.5 191.5 o7 14 196 520 (MFX400-1mRZ1-R-2761.5 21.5 or 15 23.3 730 MEX400-1mRZ1-R-37C1.5 BTA S o7 18 26.3 980 MFX400-1mRZ1-R-5C2.5 5x25 o7 12 125 240 MFX400-1mRZ1-R-762.5 25 o7 12 144 300 MEX400-1mRZ1-R-1202.5 122.5 o7 13 1868 490 MFX400-1mRZ1-R-1902.5, 19x25 o7 14 2A 750 MFX400-1mRZ1-R-2702.5 21025 o7 18 28.4 1060 We f f 4@24 wpvIsoN —sousdtson-cabos.com x& IEC Standard Caledonian Offshore & Marine Cables MariFlex Marine Fire Resistant P BOI (MFX300) 0.6/1 kV Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant Power & Control Cables (Single Core) Application These armoured fire resistant cables are used on board of ships in all locations for fixed installations where cable protection is required. These cables are fire resistant, flame retardant, low smoke & halogen free. Standards + IEC 60092-350/351/353/359 Stranded Copper Conductor £ IEC 60331-21 Mica Tape + XLPE Insulation + IEC 60332-1 © IEC 60332-3.22 Copper Wire Braid Armour * IEC 60754-1/2 LSOH (SHF1) Sheath + IEC 61034 Construction * Conductors: Class 2 stranded copper conductor. Class 5 stranded conductors can be offered upon request. ‘+ Insulation: Mica tape + XLPE. + Armour: Copper wire braid. * Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request. Core Identification Single core: Black. Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6 OD ‘Temperature Range: -30°C ~ +80°C cmvmtanctaen AON 3B IEC Standard Caledonian Offshore & Marine Cables Resistant Power & Control Cables wa caledonan-eables,c0.UK Dimen: ns and Weight MFX300 1mRMZ1-R Single Core Armoured 0,6/kV (-R stands for class 2 conductor. For class 5 conductor, please change -R to -F) Nominal Construction Inscaton Nominal Sheath Nominal Overall Nominal Part No. No. ofcoresxCross MHNINO? Thickness Diameter Weight section(mn?) mom mm. mm kgikm MEX300-mRMZ1-R-1625 1925, og 12 13.0 410 MFX300-1mRMZ1-R-1635 1x35 09 42 148 550 MFX300-1mRMZ1-R-1C50 4%50 10 13 158 720 MFX300-1mRMZ1-R-1670 1x70 1.4 14 178 960 MFX300-1mRMZ1-R-1C95 1x95 44 14 20.7 1250 MFX300-mRMZ1-R-16120 4x120 12 15 22.8 1540 IEC Standard Caledonian Offshore & Marine Cables MariFlex Marine Fire Resistant P BFOI (MFX400) 0.6/1 kV Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant Power & Control Cables (Multicore) Application ‘These armoured fire resistant cables are used on board of ships in all locations for fixed installations where cable protection is required. These cables are fire resistant, flame retardant, low smoke & halogen free. Standards * IEC 60092-350/351/353/359 + IEC 60331-21 Stranded Copper Conductor + IEC 60332-1 Mica Tape + XLPE Insulation * IEC 60332-3-22 Extruded Inner Covering * IEC 60754-1/2 Copper Wire Braid Armour * IEC 61034 LSOH (SHF1) Sheath Construction * Conductors: Class 2 stranded copper conductor. Class 5 stranded conductors can be offered upon request. Insulation: Mica tape + XLPE. Inner Covering: Extruded inner covering ‘Armour: Copper wire braid Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request. Core Identification Two cores: Blue, Brown. Three cores: Brown, Black, Grey. Four cores: Blue, Brown, Black, Grey. Five cores: Blue, Brown, Black, Grey, Black, Multi cores: White with black numbers. cmvmtanctaen 00 37S IEC Standard Caledonian Offshore & Marine Cables Resistant Power & Control Cables wa caledonan-eables,c0.UK Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6X OD ‘Temperature Range: -30°C ~ +80°C Dimensions and Weight MFX400 1mRMZ1-R Multicore Armoured 0.6/1kV (-R stands for class 2 conductor. For class § conductor, please change -R to -F) concen | oe! linn she en Owrt in yg Paro Reet Theiss let! sedonieery | TA | Tom | mm || Am MexagonRWZ1- 30 acto 28 iste IEC Standard Caledonian Offshore & Marine Cables MariFlex Marine Fire Resistant Construction Part No. No. of coresxCross. ssection(mm?) MFX400-1mRMZ1-R-4C35 4x35 MEX400-1mRMZ1-R-5C15 x15 MEX400-1mRMZ1-R-761 5 PAS MFX400-1mRMZ1-R-1201.5 12x18 MEX400-1mRMZ1-R-19C1.5 19x15 MFX400-1mRMZI-R-2761.5 27x15 MFX400-1mRMZ1-R-37C1.5 37x15 MEX400-1mRMZ1-R-5C2.5 5x25 MFX400-1mRMZ1-R-762.5 P25 MFX400-1mRMZ1-R-1202.5 12x26 MFX400-1mRMZ1-R-1902.5 192.5 MFX400-1mRMZ1-R-2702.5 21x25 somal Noma Seat Nema O-ring ih eer 07) tga oy isa) a7 [ter | a —— IEC Standard Caledonian Offshore & Marine Cables Resistant Power & Control Cables DE BOI (MFX300) 0.6/1 kV Fire Barriers + HEPR Insulated, LSOH (SHF1) Sheathed, Screened Fire Resistant Power & Control Cables (Single Core) Application These cables are used for fixed installations on ships and offshore units in all locations and on open deck in safety circuits, where fire resistance is required. The good screening qualities of the copper braid also reduce radio interference and electrical influences to electronics installations. These cables are fire resistant, flame retardant, low smoke & halogen free. Standards DIN 89160/98 IEC 60092-353 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1/2 IEC 61034 Stranded Copper Conductor Fite Barters + HEPR Insulation Copper Wire Braid Screen LSOH (SHF1) Sheath Construction Conductors: Class 2 stranded copper conductor. Insulation: Fire barriers + HEPR Overall Screen: Copper wire braid ‘Outer Sheath: LSOH (SHF1). Core Identification Single core: Natural colour (beige). IEC Standard Caledonian Offshore & Marine Cables MariFlex Marine Fire Resistant Power & Control Cables Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6 OD Temperature Range: -20°C ~ +75°C Dimensions and Weight conscion SEPA Nanna hath Nona Oveal|__ Naina artNe Neetesekcres | STN Tell Diet vei section(mm’) mm mm mm glk umeooimenensicas as os 12 ws 220 P00 imamuZi-icas as os 12 ise 20 hrxeoomgruzsacicso tas 10 a 155 s70 roo imamuZisicro a7 ut ‘4 ts 200 PesooimemZiRices 0 ta 14 1s 17 Peoomanizsicre0 | tata0 18 1s ao ato smsseenenincon ADDIGON 47) IEC Standard Caledonian Offshore & Marine Cables Resistant Power & Control Cables DE BFOI (MFX400) 0.6/1 kV Fire Barriers + HEPR Insulated, LSOH (SHF1) Sheathed, Screened Fire Resistant Power & Control Cables (Multicore) Application These cables are used for fixed installations fixed installations on ships and offshore units in all locations and on open deck in safety circuits, where fire resistance is required. The good screening qualities of the copper braid also reduce radio interference and electrical influences to electronics installations. These cables are fire resistant, flame retardant, low smoke & halogen free. Standards Stranded Copper Conductor Fire Barriers + HEPR Insulation Lapping/Extruded Filer Copper Wire Braid Screen LSOH (SHF1) Sheath DIN 89160/98 IEC 60092-353 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1/2 IEC 61034 Construction Conductors: Class 2 stranded copper conductor. Insulation: Fire barriers + HEPR. Inner Covering: Lapping or extruded filer. Overall Screen: Copper wire braid Outer Sheath: LSOH (SHF1) Core Ident ication ‘Two cores: Black, Blue. Three cores: Black, Blue, Brown, Four cores: Black, Blue, Brown, Black. Five cores: Black, Blue, Brown, Black, Black, Multi cores: All cores natural coloured, printed with numbers, starting in center with number 1 IEC Standard Caledonian Offshore & Marine Cables MariFlex Marine Fire Resistant Cables with 3 cores and more also with green/yellow core (has to be stated in order). Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6 OD ‘Temperature Range: -20°C ~ +75°C Dimensions and Weight Construction Nominal Sheath Nominal Overall Nominal Part No, No, of coresxCross Thickness Diameter Weight ssection(mm?) mm mm ark MEX400-1mG7MZ1-R-2C1.5 2x15 12 125 210 MEX400-1mG7MZ1-R-262.5 2x25 42 130 250 MFX400-1mG7MZ1-R-264 2x4 13 140 300 MFX400-1mG7MZ1-R-208 2x6. 13 160 410 MFX400-mG7MZ1-R-2610 2x10 14 180 550 MEX400-1mG7MZ1-R-2616 2x18 15 200 720 MFX400-1mG7MZ1-R-2625 2x25 16 235 1050 MFX400-1mG7MZ1-R-3C1.5. 3x15 12 130 230 MFX400-1mG7MZ1-R-3C2.5 3x25 42 140 280 MEX400-1mG7MZ1-R-3C4 3x4 13 15.0 350 MEX400-1mG7MZ1-R-3C8 3x6 13 165 480 MFX400-1mG7MZ1-R-3C10 3x10 14 190 670 MFX400-1mG7MZ1-R-3C16 3x16 15 210 870 MFX400-1mG7MZ1-R-3625 3x25 47 245 41300 MEX400-1mG7MZ1-R-2C35 3x35 18 270 1680 MFX400-1mG7MZ1-R-3C50 3x50 24 305 2190 MFX400-1mG7MZ1-R-3C70 3x70 20 350 3020 MFX400-1mG7MZ1-R-3C95 3x95, 23 395 4050 MEX400-1mG7MZ1-R-3C120, 3x120 25 440 5000 MFX400-1mG7MZ1-R-4C1.5 4x15 12 135 210 MFX400-1mG7MZ1-R-4C2.5 4x25 13 150 330 MEX400-1mG7MZ1-R-4C4 4x4 13 165 460 MFX400-1mG7MZ1-R-4C8 4x6 14 180 550 MEX400-1mG7MZ1-R-4C10 4x10 15 205 790 MFX400-1mG7MZ1-R-4C16 4x16 18 230 1080 MFX400-1mG7MZ1-R-4C25 4x25 18 270 1630 MFX400-1mG7MZ1-R-5C1.5 5x15 43 145 320 MEX400-1mG7MZ1-R-5C2.5 5x25 13 165 440 MFX400-1mG7MZ1-R-7C1.5 DAS 13 165 400 MFX400-1mG7MZ1-R-1001.5 10x15 43 195 450 MFX400-1mG7MZ1-R-412C1.5 taxt.6 14 200 510 MEX400-1mG7MZ1-R44C1.5 14x15 44 2190 570 MEX400-1mG7MZ1-R-18C1.5 16x15 14 220 840 MFX400-1mG7MZ1-R-19C1.5 19x15 15 235 730 MFX400-1mG7MZ1-R-2401.5 2axt5 16 2790 910 IEC Standard Caledonian Offshore & Marine Cables int Instrumentation & Control Cables DE TI (MRE-2XH) 150/250V XLPE Insulated, LSOH (SHF1) Sheathed Flame Retardant Instrumentation & Control Cables (Multicore) Application These cables are used on board of ships at all locations for fixed installations not subject, to mechanical risk complying with IEC standards 6092-352. These cables are flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels. Standards «IEC 60092-350/351/376/359 irene Copper Conductor * IEC 60332-1 + IEC 60332-3-22 XLPE Insulation * IEC 60754-1/2 USOH (SHE?) Sheath + IEC 61034 Construction * Conductors: Class 2 stranded copper conductor. + Insulation: XLPE. + Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request. Core Identification White with printed number. Mechanical and Thermal Properties Bending Radius for Fixed Installations: 4x OD ‘Temperature Range: -30°C ~ +80°C (+ so0808 ersten IEC Standard Caledonian Offshore & Marine Cables MariSig Flame Retardant Instrument Dimensions and Weight Construction Nominal Insulation Nominal Sheath Nominal Overall Nominal Part No. No.of coresxCross Thickness. Thickness Diameter ‘Weight section(mm?) mm mm mm kghkm MRE-2XH-260,75 20.75 os 14 62 50 MRE-2XH-360.75 3x0.75 05 1M 65 60 MRE-2XH-5C0.75 5x0.75 0s 42 1 80 MRE-2XH-760.75 70.75 0s. 42 83 100 MRE-2XH-1200.75 12x0.75 05 43 109 170 MRE-2xH-19C0.75 49x0.75 os 16 13.9 250 MRE-2XH-2760.75 27%0.75 05 47 156 350 MRE-2XH-3700.75 37%0.75 os 19 178 470 MRE-2XH-261.0 21.0 05 14 66 60 MRE-2xH-361.0 3x1.0 05 12 70 70 MRE-2xH-5¢1.0 5x10 os 12 82 4100 MRE-2XH-761.0 TAO 05. 13 9A 130 MRE-2xH-1201.0 12x10 05 14 "7 210 MRE-2xH-19C1.0 19x10 os 47 149 310 MRE-2XH-2761.0, 271.0 os 19 168 430 MRE-2XH-3701.0 37x1.0 os 20 199 580 - IEC Standard Caledonian Offshore & Marine Cables int Instrumentation & Control Cables DE TIOI (MRE-2XCH) 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation & Control Cables (Multicore) Application ‘These armoured cables are used on board of ships in all locations for fixed installations complying with IEC standards 6092-352. These cables are flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels. Standards * IEC 60092-350/351/376/359 * IEC 60332-1 Stranded Copper Conductor + IEC 60332-3-22 XLPE Insulation * IEC 60754-1/2 Lapping * 1EC 61034 ‘Copper Wire Braid Armour LSOH (SHF1) Sheath Construction * Conductors: Class 2 stranded copper conductor. * Insulation: XLPE. * Inner Covering: Lapping. * Armour: Copper wire braid. * Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request Core Identification White with printed number. Mechanical and Thermal Properties (a so0808 etre IEC Standard Caledonian Offshore & Marine Cables MariSig Flame Retardant Instri Bending Radius for Fixed Installations: 6 OD ‘Temperature Range: -30°C ~ +80°C mensions and Weight Construction | Nominal Instat | Nominal Sheath | Norinal Overall Nominal PartNo No.ofcoresxcross Thickness —»«Thickness-—=«‘Diameter—==_ Weight ‘section(mm?) mm mm mm kg/km MRE-2xCH-200.75 2x0.78 os 12 72 60 MRE-2xcH-360.75 3x075 os 127s so MRE-2xCH-5C0.75 5x07 05 “ee 130 MRE-2XCH-7C0.75 70.75 os 16 88 150 WMRE-2XCH-126075__12x0.75 os 17 ta 230 MRE-2XCH-1900,75 19x0.75 08 19148 320 MRE-2XCH27C0.75_ | _27x0.75 os 21a 460 MRE-2XCH-3760.75 37%0.75 05 22 L193 590, MRE-2XCH-261.0 2x10 08 1408 90 MRE-2xCH-3C1.0 axto os 148s +00 MRE-2XCH-5C1.0 sx1.0 os 1s er 150 MRE-2XCH-7C1.0, Pao Os 16 | 104 180. MRE-2xcH-1201.0 ‘axt0 os 1812 270 MRE-2XCH-1901,0 19x10 0s 24 (188 420 MRE-2xcH27C1.0 27x10 os 22 60 MRE-2XCH-37C1.0 srx10 os 24 aor 710 cvvetanetaen ON PS IEC Standard Caledonian Offshore & Marine Cables lant Instrumentation & Control Cables SEES TFOI (MRE-2XCH) 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation & Control Cables (Multipair/ Multitriple) Application These armoured cables are used on board of ships in all locations for fixed installations complying with IEC standards 60092-352. These cables are flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels. Standards + IEC 60092-350/351/376/359 sanded Copper Conductor + 1EC 603321 XLPE Insulation + IEC 60332-3-22 Lapping * IEC 60754-1/2 Copper Wire Braid Armour + IEC 61034 LSOH (SHF1) Sheath Construction Conductors: Class 2 stranded copper conductor. Insulation: XLPE. Cabling Element: Pair/Triple. Inner Covering: Lapped polyester tape. Armour: Copper wire braid Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request. Core Identification Pair: White/blue with printed pair number and core number. Triple: White/blue/red with printed triple number. IEC Standard Caledonian Offshore & Marine Cables MariSig Flame Retardant Instrument Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6 OD ‘Temperature Range: -30'C ~ +80°C Dimensions and Weight anno, NectemertoNat eines Tienes | Daron | Wo ‘section(mm’) mm mm ™m a URE 2xousp078 | an2s078 08 in 2a URE 2x08 as2.078 08 8 a0 MRE 2xous0n078 | —_—a2.078 08 ne REx 710 waa 08 s maa URE 2xoi1aP19 Hasan 08 20a IEC Standard Caledonian Offshore & Marine Cables lant Instrumentation & Control Cables wa caledonan-eables,c0.UK Ne eameetn Thora] Nonna set [Nama ovat) Fain | Hosefoementelt | Treinceclt | aiden) | oniameur | War ‘section(mm’) ™m ™m ™m al MRE-xCHaPI3 stats 28 23 aa MRE-2xCHeTO7E——x03078 os aa ano IEC Standard Caledonian Offshore & Marine Cables MariSig Flame Retardant Instrument No eee oy Nominal Insulation Nominal Sheath Nominal Overall Nominal PartNo RevoteimentsxNo-of “Thickness ‘Thickness «Diameter. Weight seetion(mm®) mm mm ™m aa MRE-2XCH-2T1.0 2x8x4.0 0s 14 134 240 MRE-2XCH-3T1.0 3x31.0 os 18 149 320 MRE-2xCH-AT1.O axaxt.0 os 18 16.1 380 MRE-2XCH-ST1.0 Sx3xt.0 0s 19 178 460 MRE-2XCH-6TO sxox1.0 os 20 200 560 MRE-2XCH-7T1.0 7x3x1.0 os 20 200 580 MRE-2XxCH-8T1.0 8xax1.0 os. 20 218 60 MIRE-2XCH-10T1.0 10x3%1.0 os 24 240 810 MRE-2XCH-1271.0 12x9x4.0 0s 22 254 820 MRE-2XCH-14T1.0 14x9x4.0 os 22 264 1020 MRE-2XCH-16T1.0 16x3x1.0 os 23 204 1150 MRE-2XCH-19T1.0 18x3x4.0 0s 24 303 1330 MRE-2XCH-20T1.0 20x0%1.0 os 24 308 1380 MRE-2XCH-24T1.0 24x9x1.0 os 25 335 1620 MRE-2XCH-3071.0 0x3x1.0 os 28 378 2060 MRE-2XCH-32T1.0 B2x3X1.0 os 29 30.9 290 MRE-2XCH-ATIS 43x15 06 13 102 160 MRE-2XCH-2T1.5 2x9x1.5 06 18 180 360 MRE-2XCH-ST15 axax1.5 08 18 174 420 MRE-2XCH-ATSS axa 5 06 19 186 510 MRE-2XCH-ST1.5 5x3x1.6 06 20 208 620 MRE-2XCH-ST1 5 exaxi.5 06 24 22 750 MRE-2XCH-7T1.5 Txaxt 6 06 24 232 600 MRE-2XCH-ET1 5 xox 5 0s 22 249 900 MRE-2XCH-10T1.6 10x9%1.5 08 29 22.4 +10 MRE-2XCH-1271.5 12x9x1.5 os 23 298 1260 MRE-2XCH-14T1 5 14x34 5 06 24 310 1410 MRE-2XCH-16T1.5 16x3x1.5 06 25 33.0 1590 MRE-2XCH-I9T1.5 19x15 os 25 35.4 1890 MRE-2XCH-2071.5 20x9%1.5 08 28 367 2010 MRE-2XCH-2471.5 24x9X1.5 os 29 399 2360 MRE-2xCH-30T1.5 300015 os 34 442 2880 MRE-2XCH-32T1.5 22K9x1.5 08 a4 457 3060 IEC Standard Caledonian Offshore & Marine Cables lant Instrumentation & Control Cables DE TIOI (MRE-2X(St)HCH) 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened & Armoured Flame Retardant Instrumentation & Control Cables (Multipair/Multitriple) Application These armoured cables are used on board of ships in all locations for fixed installations where cable protection is required. These cables are flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels. Standards LSOH (SHF4) Outer Sheath + IEC 60092-350/351/376/359 ‘Stranded Copper Conductor + IEC 60332-1 ‘Allpolyester Tape Sereen * IEC 60332-3-22 LSOH (SHF1) Inner Sheath © IEC 60754-1/2 Copper Wire Braid Armour + IEC 61034 Construction Conductors: Class 2 stranded copper conductor. Insulation: XLPE. Cabling Element: Pair/Triple. Overall Screen: Al/polyester tape. Inner Sheath: LSOH (SHF 1). Armour: Copper wire braid Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request Core Identification Pair: White/blue with printed pair number and core number. Triple: White/blue/red with printed triple number. IEC Standard Caledonian Offshore & Marine Cables MariSig Flame Retardant Instrument Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6 OD ‘Temperature Range: -30'C ~ +80°C Dimensions and Weight (Construction Nominal Sheath Thickness Ne ctomnentne | Serb = nein | ea PartNo. of cores in Thickness: Diameter. ‘Weight elementxCross Inner Outer kok secton(mm?) ™ ™ MRE-2X(S1)ICH-1PO.75, $x2K0.75 0s 10 oe 103 150 MRE-2X(S)CH2P0.75 —_2x2x0.75" os 10 oe 12 180 MRE-2X(S)HCH-3P0.75 xax0.75 os 1 09 42270 MRE-2X(S)HCH-4PO.75. 4xax0.78 os 12 08 15:1 10 MRE-2X(S)HCH-7PO.75. 7rax0.78 os 12 10 17310 MRE-2X(StHCH-9PO.75. ax2x0.75 os 13 10 184 460 MRE-2X(StHCH-10P075 __10x2x0.75 os 14 1 208 550 MRE-2X(SIHCH-2PO7.S _12x2x0.75 os 14 1 212600 MRE-OX(SI}ICH-AAPO7S —_14x2x0.75 os 14 1 a) MRE-2X(SIHCH-1GPO75 _16x2x0.75 05 15 1 234 730 MRE-2X(SIMCH-19P075 _19x2x0.75 os 15 "4 243 10 MRE-2X(SIMCH-24P075 _ 24x2x0.75 os 16 12 213 00 MRE-2X(SNHCH-20P075 __90x2x0.75 os 17 13 2031490 MRE-2X(S)}CH-32P075 _ 90x2x0.75 os 17 13 wos 1240 MRE-2X(S)}CH-97P0.75 __97x2x0.75 os 18 13 wa 1380 MRE-2X(St)HCHAIP.0 tax1.0 os 10 os 107 170 MRE-2X(St)CH.2P1.0 2x2x1.0" 0s 10 oe 72h MRE-2X(S1)HCH.3P1.0 Sx2x1.0 os 12 os 152 10 MRE-2X(S1)HCH.4P1.0 42x10 os 12 oe 158 260 MRE-2X(S1)HCH-7P1.0 Txax1.0 0s 13 10 tes 480 MRE-2X(S1)HCH-8P 1.0 ax2x1.0 os 13 10 195 520 MRE-2X(S)}CH-10P1.0, 0x2x1.0 os 14 14 28630 MRE-2X(S0HCH-12P1.0 axax1.0 os 14 1 22.5 700 MRE-2X(S)HCH-14P1.0 4xaxt.0 os 1s 1 234 770 MRE-2X(S)HCH-16P1.0 16x2x1.0 os 1s 12 25.1 60 MRE-2X(S)HCH-10P1.0 t9x2x1.0 os 18 12 252 70 MRE-2X(StHHCH.24P1.0 2ax2x1.0 0s 17 13 an) IEC Standard Caledonian Offshore & Marine Cables lant Instrumentation & Control Cables wa caledonan-eables,c0.UK caton aia Sat Tks Ne of deers | Mori oa ms rere PartNo cteseein | maton Crt wen etamenccrss 28 arta Dator Lo ‘section(mm?) MREDKSCHOMO wastes MReaxNCHe2™10 amano | estat) aa) 00 MREDKSMCHATOO —araxto | os tt) as) MREDKSIHCHIPHS eae ata MREDKSIHCHAPHS Bees TA tata MREDKSINCHOPIS aes tata MREDKCIHCHAPLS aes Tt tata MREDK(SIHCHTELS Teams? ate MREDKCSINCHOELS saws Tata ma MREDKS)NCHI0°18 joes Tt MREDKSMCHIaMIS iaaeis 7S ta MREDKOMCHUPIS wants | ey tea) ara) 00 MREDKMCHIBMS tats |e? 748 ate) H70 MREDKSMCHIO>IS tats | e717 48st MREDKSIHCHEIPIS—aaxts | oTt8 ta a5 MRE DK(SHHCHO>1S aoa S20 AS aks MREDK(\HCH2918 saat St 88a MREDKSHICH7EIS sais Tat wat MRE2K(SNCHLATO7S—ixbwO76—~=CSSS tO MREDKSNCHATO7S ———axmwO75—~—~CS Aaa MREDKNCHATO7S oO? ~~ MREDKSMCHATO7E ——aeowO7S SSNS MREAKSIHCHTIOTS TOOTS OSS MREDXSIHCHSTOTS ———aOwOT Stat MREDK'S\HCH1OTO7S ——foxtwO7S—~—CSSSAas MREDKC\HCH Tors taxtsO7S SS MRE 2X(HHCH-1TO7S —taxtv07s——=SSSStaas MRE2X(iHcH- 16707 foxtwo7s = taak MREDK(SIMCH-1oTO7S —toxawo7s 0s ttt MREDKSMCHETOTS —aoana7s | os t@ 4a) 70 MRE2xSCH0TO7S —_aoana7s | es t9 Aaa?) MREDKMCHe2TO7S —_awana7s | ost tanta MREaKHCHTIONS —_arcwa7s | 0s 2045 ae 40 MREAKSHCHATIO. kav —~S~SCSSS MREDKSHHCHATIO. advo == tat Ge Aovison sation con IEC Standard Caledonian Offshore & Marine Cables MariSig Flame Retardant Instrument we cat at [Nwin Seat Hee) gy J rani, steam | Jen rat | elementxCross Inner Outer kgm section(mm?) ™ ™ MRE-2X(S)HCH-3T1,0 3x9x1.0 os 12 40 162 370 MRE-2X(SH}HCH-ATH.0 4xox.0 os 13 40 178 440 MRE-2X(SHHCH-TTH.0 Tx3x1.0 os 14 44 214 50 MRE-2X(SHHCH-ETH.0 ex3x1.0 os 14 44 28 70 MRE-2X(SHHCH-107.0 1033.0 os 15 42 254 60 MRE-2X(SHHCH-1271.0 12x9x1.0 os 16 42 268 970 MRE-2X(S)HCH-14T1.0 14xox4.0 05 16 12 278 1070 MRE-2X(S)HCH-16T1.0 toxox4.0 05 17 13 238 +200 MRE-2X(S)HCH-1911.0 19x9x1.0 06 18 43 318 +380 MRE-2X(SHHCH-2671.0 24x0%1.0 06 19 14 364 1750 MRE-2X(SHHCH-20T1,.0 30x9%1.0 os 20 18 390 2100 MRE-2X(SHHCH-2271.0 s2x9x1.0 os 20 18 402 2210 MRE-2X(SHHCH-37T1.0 areax.0 os 24 18 423 2490 MRE-2X(SHHCH-ATI.S tx3e1.6 07 11 12 123 230 MRE-2X(S)HOH-2T1.5 2xaxt 5 07 12 12 172 380 MRE-2X(SHHOH-STH.S Bax. o7 13 12 183 470 MRE-2X(SHHOH-ATH.S Axx 5 07 13 12 197 560 MRE-2X(S)HCH-TT1.5 Text. 07 18 42 248 860 MRE-2X(SDHCH-8T1,5 Bx9.5 07 18 42 262 960 MRE-2X(SHHCH-1071.5 10x9x1.5 o7 17 43 295 1150 MRE-2X(SHHCH-1271.5 xO 5 07 17 13 208 1290 MRE-2X(SHHCH-1471.5 axa 5 o7 18 43 223 1450 MRE-2X(SHHCH-16T1.5 16x 5 07 18 14 342 1620 MRE-2X(SHHCH-19T1.5 19x9x1.5 07 19 15 373 +1950 MRE-2X(SHHCH-26T1.5 Dax 5 07 24 15 ait 2370 MRE-2X(S)HCH-20T1.5 a0xax1.5 07 22 16 453 2360 MRE-2X(S)HCH-22T1.5 B2K9x1.5 07 23 47 471 3060 MRE-2X(S)HCH-O7T1.5 Tox 5 07 24 47 493 420 *2 pairs are assembled as a quad IEC Standard Caledonian Offshore & Marine Cables lant Instrumentation & Control Cables DE TI (MRE-2X(St)H) 150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened Flame Retardant Instrumentation & Control Cables (Multipair/Multitriple) Application These cables are used on board of ships at all locations for fixed installations not subject, to mechanical risk complying with IEC standards 60092-352. These cables are flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels. Standards Stranded Copper Conductor + IEC 60092-350/351/376/359 APE Ison * IEC 60332-1 ipalyester Tape + Drain Wiro © IEC 60332-3.22 LSOH (SHF1) Outer Sheath * IEC 60754-1/2 + IEC 61034 Construction Conductors: Class 2 stranded copper conductor. Insulation: XLPE Cabling Element: Pair/Triple Overall Screen: Al/polyester tape. Drain Wire: Tinned copper wire. Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request, Core Identification Pair: White/blue with printed pair number and core number. Triple: White/blue/red with printed triple number. IEC Standard Caledonian Offshore & Marine Cables MariSig Flame Retardant Instrument Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6X OD Temperature Range: -30°C ~ +80°C Dimensions and Weight a eres Eira cece terest orwell nen an No : Thickness Dieter Wo caetinsomert25mm); 4 OD (OD <25mm) ‘Temperature Range: -30 ~ 480°C Dimensions and Weight Part No. MRE-M2X(SH-1P0.75 MREN2X(S)H-2P0.75 MRE-M2X(S0H-3PO.75. MRE-M2X(S)H-4P0.75 MRE-M2X(S0)H-7P0.75 MRE-N2X(S)H-8PO.75 MRE-M2X(S)H-10P0.75, MRE-M2X(S)H-12P07.5, MRE-M2x(S1)H-14P0.75, MRE-M2X(S1)H-16P0.75 MRE-M2X(S)H-19P0.75 MRE-M2X(S)H-24P0,75, MRE-M2X(S1)H-30P0.75, MRE-M2x(S)H-32P0.75, MRE-M2x(S1)H-37P0.75 MRE-M2X(S)H-1P1.0 MRE-M2x(St)H-2P1.0 MRE-M2X(St)H-3P1.0 MRE-M2X(S)H-4P1.0 MRE-M2X(S)H-7P1.0 MRE-M2x(S1)H-8P1.0 MRE-M2X(SH)H-10P1.0 MRE-M2X(S)H+12P1.0 MRE-M2x(S)H-14P1.0 MRE-M2x(S)H-16°1.0 MRE-M2x(S)H-19P1.0 MRE-M2X(S1)H-24P1.0 MRE-M2x(S)H-30P1.0 Construction No, of elementsxNo. of cores in elementxCross section(mm) 1x2x0.75, 252x075" 3x2%0.75 4x2%0.75 Tx2x0.75 8x2%0.75 10%2%0.75 12%2%0,75 1420.75 1620.75 19%2%0.75 24x2x0,75, 30x2x0.75 32x2x0.75 37*2x0.75 1x2x1.0 2x2x1.0° 3x2x1.0 4201.0 T2x1.0 Bx2x1.0 10x2%1.0 12x2x1.0 1421.0 16x2x1.0 19x2x1.0 24x2x1.0 30x2x1.0 wut adaigon-cabes.com Nominal Insulation Thickness os os 05 os os os 05 08 os os 0s 08 os os os 08 05 os os 05 05 os 05 05 05, os 05 08 Nominal Sheath Nominal Overall Thickness 10 1. 42 13 14 14 15 15 18 18 47 18 20 20 20 14 1 13 13 14 15 18 18 18 1 a 19 2.0 Diameter a4 95 133 143 173 184 20.9 27 227 24.4 257 29.3 334 338 353 87 99 142 18.41 18.3 197 22.3 23.2 244 28.4 273 313 354 Nominal Weight kath 70 10 170 210 320 360 430 490 560 630 730 910 1140 1190 1340 90 130 200 240 370 430 520 590 860 760 860 ‘1100 19350 IEC Standard Caledonian Offshore & Marine Cables MariSig Fire Resistant Instrumentati Contain Wairal patna __| Me otorernss of | nein Ri Ser snl OH og GrecionosGron | Ture THD | lant MOTE ‘section(mm*) mm MREMDXIHOPI0——socaxi@ 08 aoe MREAEKGSIH7P.0 | aPeont0 os ean) en une woxsarts | axaxns 06 us ‘oo | 0 MREMDXGI}EPLS Sees 06 re) uREMeXsaPis | eee 08 is ee) ato URE NDNSDH TPS Hones 08 wae | 70 MRE MOXS208 | thant 08 20) a6) MRE WaRESHSTIO oxox 0s 13 ws a IEC Standard Caledonian Offshore & Marine Cables Instrumentation & Control Cables wa caledonan-eables,c0.UK Ne.cfecrenzrto.of| Mmuaton Neil Sesh Nonbal Oe an wag arte cores in elementxCross Thickness “Thickness Diameter kg/km section(mm?) mm mm mm MRE-M2X(S)H-TT1.0 T3X1.0 os 15 216 540 MRE-M2X(S)H-BT1.0 8x3x1.0 os 18 233 620 MRE-MAX(SI)H-10T1.0 10%3%1.0 0s 47 265 740 MRE-M2X(SHH-12T1.0 12x3x1.0 05 18 282 870 MRE-MOX(SI)H-14T1.0 44x3x1.0 05 18 204 980 MRE-MAX(SI)H-A6T1.0 16x3x1.0 0s 19 314 1110 MRE-MAX(SI)H-19T1.0 1931.0 0s 20 34a 1310 MRE-M2X(SH-24T1.0 2axax1.0 05 24 379 1620 MRE-MAX(SI)H-S0T1.0 30x3x1.0 05 23 422 2010 MRE-MAX(SI)H-32T1.0 32x3x1.0 0s 24 439 2150 MRE-MAX(SY)H-37T1.0 37x3x1.0 0s 24 480 2430 MRE-M2X(SOH-ATI.S 1xax15 06 1 10.0 130 MRE-M2X(SHH-2T1.5 2xaxi 5 06 13 160 260 MRE-M2X(SHH-3TI.S Bx3X1.5 06 14 472 340 MREMAX(SHHATI 5 4xax15 06 14 189 430 MRE-M2X(S)H-711.5 Teaxt 5 08 18 240 700 MRE-M2X(S)H-8T1 5 Bxaxi5 06 47 25.9 800 MRE-MAX(SIH-10T1.5 10x3x1.5 06 18 295 970 MRE-MOX(SHH12T1.5 12x3x1.5 06 19 314 1130 MRE-MAX(SYH-14T1.5 14xax1 5 08 20 33.0 1300 MRE-MOX(SHH-16T1.5 16x3x15 os 20 360 1480 MRE-MAX(S)H-19T1.5 19x3x1.5 06 24 379 1710 MRE-MAX(SI)H-2471 5 2axSx1 5 06 23 a4 2140 MRE-MAX(S)H-30T1.5 30x3x15 0s 25 472 2660 MRE-M2X(S1)H-3271 5 32x3x15 os 25 489 2820 MRE-MOX(S)H-3771 5 B7KBx1.5 08 26 514 3210 *:2 pairs are assembled as a quad. IEC Standard Caledonian Offshore & Marine Cables MariSig Fire Resistant Instrumentati BI (MRE-M2XH PiMF/TiMF) 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Individual Screened Fire Resistant Instrumentation & Control Cables (Multipair/Multitriple) Application These cables are used on board of ships in all locations for fixed installations not subject, to mechanical risk complying with IEC standards 60092-362 in safety circuit, where fire resistance is required. These cables are fire resistant, flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels. Standards Stranded Copper Conductor Mica Tape + XLPE insulation + IEC 60092-350/351/376/359 ‘Alpolyesiee Tape + Dein Wie + IEC 60331-21 LSZH (SHF1) Outar Shoath + IEC 60332-1 + IEC 60332-3-22 * IEC 60754-1/2 * IEC 61034 Construction Conductors: Class 2 stranded copper conductor. Insulation: Mica tape + XLPE Cabling Element: Pair/Triple. Individual Screen: Aljpolyester tape. Drain Wire: Tinned copper wire Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request. Core Identification Pair: White/blue with printed pair number and core number. Triple: White/blue/red with printed triple number. cmvmtanctaen ON 7B IEC Standard Caledonian Offshore & Marine Cables int Instrumentation & Control Cables wa caledonan-eables,c0.UK Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6 X OD (OD>25mm); 4 OD (OD <25mm) ‘Temperature Range: -30°C ~ +80°C Dimensions and Weight Construction Nominal No.of elementsxNo. of Insulation Nominal Sheath Nominal Overall weight Pan No. cores inelementxGross Thickness ‘Nenness Diameter kak section(mn) mim ™m ™m MRE-M2XH PiMF-1P0.75 1%2%0.75 os 10 73 20 MRE-M2XH PIMF-2P0.75 2x2x0.75 0s 12 124 170 MRE-M2XH PiMF-3P0.75 3x2x0.75 05 12 132 210 MRE-M2XH PiM-4PO.75 4x2%0.75 05 13 143 260 MRE-M2XH PIMF-5PO.75 5x2x0.75 os 13 160 320 MRE-M2XH PiMF-6PO.75 6x2x0.75 05 14 174 380 MRE-M2XH PIMF-7PO.75 Tx2x0.75 0s 14 114 410 MRE-M2XH PiME-8PO.75 820.75 05 14 185 460 MRE-M2XH PiMF-1000.75 10%2%0.75 0s 15 210 570 MRE-M2XH PiMF-12P0.75 12x2x0.75 0s 15 218 650 MRE-M2XH PiME-14P0.75 14x2%0.75 05 18 29 740 MRE-M2XH PiMF-16P0.75 16x2x0.75 05 18 248 840 MRE-M2XH PiMF-19P0.75 1920.75 0s 17 265 980 MRE-M2XH PiMF-2000.75 20%2%0.75 05 17 265 1010 MRE-M2XH PiMF-2400.75 24x2%0.75 0s 19 308 1260 MRE-M2XH PiMF-30P0.75 30%2%0.75 05 20 334 1530 MRE-M2XH PiMF-370.75 37%2%0.75 05 24 35.9 1830 MRE-M2XH PIMF-1P1.0 txaxt.o 05 10 83 90 MRE-M2XH PiMF-2P1.0 2x2x1.0 05 12 134 200 MRE-M2XH PiMF-3P1.0 3x2%1.0 os 13 142 250 MRE-M2XH PIMF-4P1.0 4x2%1.0 05 13 164 310 MRE-M2XH PiMF-5P1.0 5x2x1.0 05 14 aA 380 MRE-M2XH PiMF-6P1.0 6x2x1.0 os 14 184 440 MRE-MAXH PiME-7P1.0 Tx2x1.0 08 14 184 480 MRE-M2XH PiMF-BP1.0 8x2x1.0 05 15 198 550 MRE-M2XH PiMF-10P1.0 40x2%1.0 os 18 224 690 MRE-MaXH PiME-12P1.0, 1252%1.0 08 18 233 780 MRE-M2XH PiMF-14P1.0 14x2%1.0 05 18 242 880 MRE-M2XH PIME-16P1.0 16x2x1.0 05 47 263 020 MRE-M2XH PiME-19P1.0 1921.0 05 18 283 1190 IEC Standard Caledonian Offshore & Marine Cables MariSig Fire Resistant Instrumentati cn a jaing __| Neefeorre ot | maaton NOMS SHEN OH ay cores inelementxCross Thickness mm ‘mm kg/km momen [ee MRE Ao TW TE 75 | exes os tas) REA TALL aos a ro) IEC Standard Caledonian Offshore & Marine Cables int Instrumentation & Control Cables DE BFOI (MRE-M2XCH) 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant Instrumentation & Control Cables (Multipair/Multitriple) Application These cables are used on board of ships in all locations for fixed installations complying with IEC standards 60092-352 in safety circuit, where fire resistance is required. These cables are fire resistant, flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels. Standards Srandod Copper Conductor * IEC 60092-350/351/376/359 Pavetrase austen + IEC 60331-21 ‘Copper Wire Bid Armour + IEC 60332-1 LSOH (SHF1) Outer Shoah + IEC 60332-3-22 + IEC 60754-1/2 + IEC 61034 Construction Conductors: Class 2 stranded copper conductor. Insulation: Mica tape + XLPE. Cabling Element: Pair/Triple. Inner Covering: Lapped polyester tape. ‘Armour: Copper wire braid Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request. Core Identification Pair: White/blue with printed pair number and core number. Triple: Whiteblue/red with printed triple number. IEC Standard Caledonian Offshore & Marine Cables MariSig Fire Resistant Instrumentati Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6X OD ‘Temperature Range: -30°C ~ +80°C Dimensions and Weight vo atucen | Nonine Nonna! Sesh Nori Overe| Noni Par, Thess | Diarter | We cores nslomerxCross Thsowes cra] seston ri MRE oxoH1PO75 ars os ra a ‘20 MRE oxci.2P078 pasos os ta tn 180 MRE oxo. 0075 os te us 220 MRE xch.4P0.75 a0 os ie tsa 220 MRE oxcH-sP078 bns078 os is 2 200 MRE oxcH6P0.75 0075 os ts tas 40 MRE MxcH.7P0.75 rasa os ts tas ‘60 Re woxciaP.75 0.075 os 20 ta S20 MREDXCH-1000.75 102x075 os 20 aT 20 MREMDXCIL120078 axxo 78 os 21 ne m0 MRENDXCH-O75 ———_4x2x0 75 os a1 ae 7 MREMDXCHLI8°078 —_——_t0s23075 os 22 24 a MRE NOXGI-i99078 19423078 08 22 m0 220 MRENDXCH20°0.75 204230 75 os 22 270 s010 MRE NDXCH-240078 ——_ats2x0 78 os 2a 208 i200 MRE-MoxcH2000.75 ———_—soxax075 os 28 as ‘a0 MRENDXCHATPOTS ———_s7a2x0 78 os 28 ase tro MRE axe -1P1.0 ax os i 28 ‘20 MRE wxcsi2>9 paxto os 1a ‘07 170 MRE waxes 2.0 past os ts ts8 220 MRE Max 401.0 bani os ts we aso MRE WaXco5%9 scaxt os ‘8 was 0 MRE wax 01.0 axaxt os 20 tes 510 MRE MaXGH7%.0 rani os 20 wes s20 MRE Xcr% 0 bast os 20 207 590 MRE WxcH 1010 txaxt0 os 21 a2 no URE NaXcH 1210 teaxto os a 2a a0 URE oxcH ta. eax os 22 2s: 200 MRE Naxci 16%. teaxt0 08 22 m8 i010 URE WaXcH-1910 taaxto 0s 23 28 0 IEC Standard Caledonian Offshore & Marine Cables int Instrumentation & Control Cables wa caledonan-eables,c0.UK No. oof neatal Nominal Sheath Nominal Overal Nominal Part No. cowsinetemenecrass Thieknesy ‘Thexness Diameter ‘Weight ssection(mm?) mm mm mm oy MRE-M2XCH-20P 1.0 20x2x1.0 08 23 288 1190 MRE-M2XCH-24P 1.0 24x2%1.0 os 25 33.0 1460 MRE-M2XCH-30P 1.0 30x2%1.0 05 26 358 1740 MRE-M2XCH-37P 1,0 372x1.0 08 29 388 2140 MRE-M2XCH-1P1 5 12x15 06 13 108 160 MRE-M2XCH-2P1 5 2x2x15 08 14 421 220 MRE-M2XCH-3P1.5: Bx2K15 06 19 174 400 MRE-M2XCH-4P1.5 4x2x15 06 19 184 470 MRE-M2XCH-5P1.5 Sx2x15 08 20 206 570 MRE-M2XCH-6P1.5 Bx2x15 06 24 222 660 MRE-M2XCH-7P1.5 TDK 5 08 24 222 700 MRE-M2XCH-8P1.5 Bx2x15 08 24 236 780 MRE-M2XCH-10P 1.5 10x2«15 08 22 265 950 MRE-M2XCH-12P1.5 12x2x15 08 23. an 1070 MRE-M2XCH-14P 1.5 14x2x1.5 06 23 28.7 1180 MRE-M2XCH=6P1.5 16x2x15 06 24 31.0 1350 MRE-M2XCH-19P 1.5 192x158 08 25 332, 1560 MRE-M2XCH-20P 1.5 20x2x1.5 06 25 332 1590 MRE-MAXCH-24P 1.5 24x2x1.5 06 29 385 2080 MRE-M2XCH-S0P 1,5 3021.5 08 3.0 a8 2450 MRE-M2XCH-37P 1.5 37x2x1.5 06 34 447 2880 MRE-MAXCH-1T0.75. 1x3x0.75 05 13 95 430 MRE-M2XCH-270.75 2x3x0.75 0s 18 148 290 MRE-M2XCH-3T0.75. 3x3x0.75 os 18 187 340 MRE-MAXCH-4T0.75. 4x3x0.75 05 19 472 410 MRE-M2XCH-5T0.75. 5x3x0.75 05 19 188 480 MRE-M2XCH-8T0.75. 8x3x0.75 05 20 212 590 MRE-M2XCH-770.75. Tx3x0.75 05 20 22 620 MRE-M2XCH-8T0.75. 8x3x0.75 05. 24 28 700 MRE-MBXCH-10T0.75 40%3%0.75 05: 22 257 8680 MRE-MAXCH-12T0,75 12x3%0.75 05: 22 270 970 MRE-MAXCH-14T0.75 14x3x0.75 05 23 283 1080 MRE-MaXCH-16T0.75 46x3%0.75 05 23 299 +200 MRE-MaXCH-1910,75 419x3%0.75 05. 24 32.3, 1390 MRE-M2XCH-20T0.75 2030.75 05 28 330 1460 MRE-MAXCH-24TO0.75 24x3x0.75 05 26 35.9 4710 MRE-M2XCH-30T0,75 30x3%0.75 05. 29 40.1 2170 MRE-M2XCH-82TO 75 82x3%0.75 05. 30 a7 2320 MRE-M2XCH-1T.0 tx3x1.0 08 13 99 150 MRE-M2XCH2T1.0 2x3x1.0 0s 18 156 320 Ge aovison sation con IEC Standard Caledonian Offshore & Marine Cables MariSig Fire Resistant Instrumentati No ot nominal Nominal Sheath Nominal vera Nominal PartNo, Thickness Diameter Weight cores inelementxCross Thickness mm mm kgikm section(mm?) mm MRE-M2XCH-3T1.0, Sx3x1.0 0s 18 165 380 MRE-M2XCH-4T1.0 4x3X1.0 05 19 184 470 MRE-MOXCH-ST1.0 5x3x1.0 0s 20 20. 560 MRE-M2XCH-6T1.0, 6x3x1.0 os 24 226 680 MRE-M2XCH-711.0 73x10 05 24 26 720 MRE-M2XCH-8T1.0 Bx3x1.0 0s 24 244 810 MRE-M2XCH-10T1.0 40x3x1.0 05 22 272 990 MRE-M2XCH-12T1.0 12x3x1.0 05 23 288 1130 MRE-M2XCH-14T1.0 14x3x1.0 05 23 300 1260 MRE-M2XCH-16T1.0 46x3x1.0 0s 24 319 1410 MRE-M2XCH-19T1.0 19x3x1.0 05 25 344 1640 MRE-M2XCH-20T1.0 20x3x1.0 0s 25 35.0 1700 MRE-M2XCH-24T1.0 24x3x1.0 05 29 388 2110 MRE-M2XCH-30T1.0 3031.0 05 30 428 2560 MRE-M2XCH-3271.0 32x3x1.0 0s 34 44a 2730 MRE-MOXCH-1T1.5 Axax1 5 os 13 to 180 MRE-M2XCH-2T1.5 2x3X1.5 0s 19 177 410 MRE-MOXCH-ST1.5 xBX1.5 0s 19 187 490 MRE-MOXCH-AT1.5 @Gx1.5 06 20 206 610 MRE-MOXCH-ST1.5 BxSx1.5 0s 24 229 40 MRE-MOXCH-6THS 6x3X1.5 06 22 258 890 MRE-MOXCH-7T1.5 TGX1.5 08 22 258 950 MRE-M2xCH.8T1.5 Bx3x1.5 06 23 207 1070 MRE-M2xcH-10T1.6 10x3x1.5 06 24 313 1320 MRE-M2XCHA2T1.5 12x3x1.5 0s 25 332 1520 MRE-M2xcH-4T1.5 14x3X1.5 06 25 346 1690 MRE-M2XCH-16T1.5 16x3x1.5 08 28 373 1980 MRE-M2XCH-19T1.5 19x3x1.5 06 29 403 2310 MRE-M2xCH2071.5 20x3x1.5 06 3.0 ait 2420 MRE-M2XCH.2471.5 24x3x1.5 06 34 447 2840 MRE-M2XCH.30T1.5 30x3x1.5 06 33 495 3460 MRE-M2XCH32T1.5 32x3x1.5 06 33 512 3670 *:2 pairs are assembled as a quad. IEC Standard Caledonian Offshore & Marine Cables int Instrumentation & Control Cables DE BFOI (MRE-M2XCH PiMF/TiMF) 150/250V Mica Tape + XLPE Insulated, LSOH (SHF1) Sheathed, Individual Screened & Armoured Fire Resistant Instrumentation & Control Cables (Multipair/Multitriple) Application These cables are used on board of ships in alll locations for fixed installations complying with IEC standards 6092-352 in safety circuit, where fire resistance is required. These cables are fire resistant, flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels. Standards LSOH (SHF1) Outer Sheath Siranded Copper Conductor «IEC 60092-350/351/376/359 nlgeeuter rene © Dean re * IEC 60331-21 Polyester Tape * TEC 603321 Copper Wire Braid Amour + IEC 60332-3-22 + IEC 60754-1/2 + IEC 61034 Construction Conductors: Class 2 stranded copper conductor. Insulation: Mica tape + XLPE. Cabling Element: Pair/Triple Individual Screen: Aljpolyester tape. Drain Wire: Tinned copper wire. Inner Covering: Lapped polyester tape. Armour: Copper wire braid ‘Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request. Core Identification Pair: White/blue with printed pair number and core number. IEC Standard Caledonian Offshore & Marine Cables MariSig Fire Resistant Instrumentati Triple: White/blue/red with printed triple number. Mechanical and Thermal Properties Bending Radius for Fixed Installations: 6x OD ‘Temperature Range: -30°C ~ +80°C Dimensions and Weight Construction Nominal | Nominal nal Overall Noma! part No No,ofelementsxo,of insulation Shean NomnalOveral’_ Nomina cores in elementxCross Thickness Thickness section(mmn?) mm mm mm ei MRE-M2XCH PIMF-APO.75 1x2x0.75 0s 13 93 130 MRE-M2XCH PIMF-2°0.75 2x2x0.75 05 14 136 230 MRE-MOXCH PIMF-3P0.75 3x2x0.75 0s 18 15: 320 MRE-MOXCH PIME-4P0.75 4240.75 05 18 180 370 MRE-MOXCH PIMF-SPO.75 5x2x0.75 os 18 178 450 MRE-MOXCH PIMF-6PO.75 8x2x0.75 0s 19 191 510 MRE-MOXCH PIME-7P0.75. 1x2x0.75 05 19 191 540 MRE-MOXCH PIMF-8PO.75 8x2x0.75 os 20 204 610 MRE-MOXCH PIME-10P0.75, 40x2x0.75, os 24 229 140 MRE-M2XCH PIMF-12°0.75 12x2x0.75 os 24 21 630 MRE-MOXCH PIMF-14P0.75, 14x2x0.75 0s 24 248 910 MRE-M2XCH PIME-16P0.75, 18x2x0.75, 0s 22 265 1040 MRE-M2XCH PIMF-19°0.75, 19%2x0.75 0s 23 204 1200 MREM2XCH PIMF-20P0.75 | __20x2x0.75 0s 23 204 1230 MRE-MOXCH PIMF-24P0,75 | _ 2420.78 os 24 328 1490 MRE-MOXCH PIMF-20P0.75 __30x2x0.75 os 25 351 1790 MREM2XCH PIMF-37P0.75|__97x2x0.76 0s 28 3B. 200 MRE-MOXCH PIMF-1P1.0 12x19 os 13 a7 140 MRE-MOXCH PIMF-2P1.0 2x2xi.0 os 18 150 300 MRE-M2XCH PIME-2P1.0 32x10 05 18 159 360 MRE-M2XCH PIMF-4P!.0 a2x1.0 os 19 170 490 MRE-MOXCH PiMF-SP'.0 Sx2x1.0 os 19 188 510 MREM2XCH PIMF-AP'1.0 ex2x1.0 os 20 203 600 MRE-M2XCH PIMF-7P1.0 Tr2x1.0 os 20 203 620 MRE-M2XCH PIMF-8P'.0 ax2xi.0 05 20 215 700 MRE-M2XCH PIME-10P1.0 10x2x1.0 os 24 244 960 MRE-M2XCH PIMF-412P1.0 2x21.0 os 22 252 920 MRE-MOXCH PIMF-14P1,0 14x2x1.0 os 22 26.1 +1080 MRE-M2XCH PIMF-16P1.0 16x21.0 os 23 202 1230 Part No, MRE-M2XCH PIMF-19P1.0 MRE-M2XCH PIMF-20P1.0 MRE-M2XCH PIMF-24P1.0 MRE-M2XCH PiMF-30P1.0 MRE-M2XCH PIMF-37°1.0 MRE-M2XCH PIMF-1P1.5 MRE-M2XCH PIMF-2P1.5 MRE-M2XCH PIMF-3P 1.5 MRE-M2XCH PIMF-4P 1.5 MRE-M2XCH PIMF-5P1.5 MRE-M2XCH PIMF-6P1.5 MRE-M2XCH PIMF-7P 1.5 MRE-M2XCH PIMF-8P1,5, MRE-M2XCH PIMF-10P1.5 MRE-M2XCH PIMF-12P1.5 MRE-M2XCH PIMF-14P1.5. MRE-M2XCH PiMF-16P1.5 MRE-M2XCH PIMF-19P1.5 MRE-M2XCH PIMF-20P 1.5 MRE-M2XCH PIMF-24P 1.5 MRE-M2XCH PIMF-30P1.5 MRE-M2XCH PIMF-37P1.5 MRE-M2XCH TIMF-1T0.75 MRE-M2XCH TIMF-210,75 MRE-M2XCH TIMF-3T0.75 MRE-M2XCH TIMF-4T0.75 MRE-M2XCH TIMF-5T0.75 MRE-M2XCH TIMF-6T0.75 MRE-M2XCH TIMF-770,75 MRE-M2XCH TIMF-8T0.75 MRE-M2XCH TMF-10T0.75 MRE-M2XCH TIME-1270.75 MRE-M2XCH TMF-1470.75 MRE-M2XCH TMF-1670.75, MRE-M2XCH TiMF-19T0,75 MRE-M2XCH TiMF-20T0.75 MRE-M2XCH TMF-24T0.75 MRE-M2XCH TiMF-30T0.75 MRE-M2XCH TMF-3270.75 Construction No. of elementsxNo. of cores in elementxCross section(mm®) 19x2x1.0 20x2x1.0 24x2x1.0 30x2x1.0 3TH2x1.0 Ox1 5 2x2x1.5 32x15, 4x2x1.5 5x2x1.5, ex2x1.5, Tx2x1.5 8x2x1.5 10%2x1.5 122x158 14x21.5 16x2x1.5 19x2x1.5 20x2x1.5 2Ax2x1 5 30x2x1 5 37x2x15 1x3x0.75 2x3x0.75 3x3x0.75 4x3x0.75 5x3%0.75 8x3X0.75 7x3x0.75 8x3%0.75 10x3x0.75 12x3x0.75 14x3x0.75 16x3x0.75 193%0.75 2030.75 24x3x0.75 30x3x0.75 32x3X0.75 Nominal Insulation Thickness mm os 0s 05 os 05 08 06 06 06 06 os o8 06 08 06 08 08 06 08 08 08 06 0s 05 05 0s 05 05 08 05 05 0s. 05 os os os os 05 0s Nominal Sheath Thickness mm. 23 23 25 28 29 13 19 19 19 20 24 24 24 23 23 23 24 25 25 29 3.0 32 13 18 18 19 20 24 2A 24 22 23 23 24 25 25 28 30 30 Nominal Overall Diameter 300 300 34.4 378 405 107 169 179 19.0 23 23.0 23.0 244 278 28.7 29.7 324 344 344 39.9 43.3 465 a7 184 162 179 198 22 22.2 237 267 28.3 29.4 314 33.9 344 379 420 434 IEC Standard Caledonian Offshore & Marine Cables int Instrumentation & Control Cables wa caledonan-eables,c0.UK Nomi Weight kgm 1410 1450 1780 2220 2620 170 380 450 530 650 750 800 890 a0 1250 1380 1580 1820 1870 2400 2870 3410 140 320 380 460 560 670 710 800 980 1120 1240 1400 1620 1680 2070 2520 2670 IEC Standard Caledonian Offshore & Marine Cables MariSig Fire Resistant Instrumentati Construction Nominal Nominal \sninal Overall Nominal rer No. of elementsxNo. of Insulation Sheath a ED ‘cores inelementxCross Thickness Thickness ™~ i section(mm?) mm mm. MRE-M2XCH TIMF-1T1.0, 1x3x1.0 05 13 10.4 160 MRE-M2XCH TIMF-211.0 2x3x1.0 05 18 164 360 MRE-M2XCH TIMF-3T1.0, 3x3x1.0 05 19 173 440 MRE-M2XCH TMF-4T1.0, 4x3x1.0 os 19 188 530 MRE-M2XCH TIME-5T1.0 5x3x1.0 0s. 20 208 640 MRE-M2XCH TIMF-6T1.0, 8x3x1.0 05 24 23.4 770 MRE-M2xCH TIMF-771.0 Tx3x1.0 os 24 234 820 MRE-M2XCH TIMF-8T1.0 8x3x1.0 os. 22 252 930 MRE-M2XCH TIMF-10T1.0 10x3x1.0 os 23 28.4 1150 MRE-M2XCH TIME-12T1,0 123%1.0 os 23 29.9 1310 MRE-M2XCH TIMF-1471.0 14x3%1.0 os 24 313 1470 MRE-M2XCH TIMF-16T1.0 46x3x1.0 Os 25 334 1660 MRE-M2XCH TIME-19T1,0 19x3%1.0 0s. 28 36.5 2010 MRE-M2XCH TiMF-2071.0 20%3x1.0 os 28 37.1 2080 MRE-M2XCH TiMF-24T1.0 28x3x1.0 O8 29 403 2450 MRE-M2XCH TiME-3071,0 30x3x1.0 oe 3a 447 3000 MRE-M2XCH TiMF-3271.0 32x3x1.0 os 34 46.2 3180 MRE-M2XCH TMF-AT1.5, IxSx1.5 06 14 114 200 MRE-M2XCH TiMF-271.5 2x3x1.5 08 19 182 450 MRE-M2XCH TIMF-3T1.5 3x3x1.5 08 20 195 560 MRE-M2XCH TIME-411.5 4x3x1.5 08 20 213 670 MRE-M2XCH TiMF-ST1.5 5x3x1.5 08 24 236 820 MRE-M2XCH TIMF-6T1.5 6x3x1.5 os 22 286 990 MRE-M2XCH TIME-7115 Tx3x1.8 08 22 286 1080 MRE-M2XCH TIMF-8T1 5 Bx3x1.5 08 23 286 1200 MRE-M2XCH TIMF-1071.5 10xax1.5 06 24 32.3 1480 MRE-M2XCH TIMF-1271.5, 12x3%1.5 06 25 34.3 1700 MRE-M2XCH TIMF-1471.5 1axaxt 5 06 26 35.9 1920 MRE-M2XCH TIMF-1671.5 16x3x1.5 08 29 38.8 2280 MRE-M2XCH TIMF-1971.5 19x3x1 5 08 3.0 418 2620 MRE-M2XCH TIMF-2071.5 20x31 5 06 3.0 425 2720 MRE-M2XCH TIMF-2611.5 2Ax3x15: 08 34 46.2 3200 MRE-M2XCH TIMF-30T1.5 30x3x1.5 08 33 512 3910 MRE-M2XCH TIMF-32T1.5 B2x3x1.5 06 a4 53.2 4180 IEC Standard Caledonian Offshore & Marine Cables int Instrumentation & Control Cables DE BOI (MRE-M3GCH) 150/250V Mica Tape + HEPR Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant Instrumentation & Control Cables (Multipair) Application These cables are used on board of ships in all locations for fixed installations complying with IEC standards 60092-352 in safety circuit, where fire resistance is required. These cables are fire resistant, flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels. Standards Stranded Copper Conductor * DIN 89159 Mica Tape + HEPR Insulation © IEC 60092-351/375/359 Copper Wire Braid Armour * IEC 60331-21 LSOH (SHF1) Sheath * IEC 60332-1 © IEC 60332-3-22 © IEC 60754-1/2 © IEC 61034 Construction Conductors: Stranded copper conductor. Insulation: Mica tape + HEPR Cabling Element: Pair. ‘Armour: Copper wire braid Outer Sheath: LSOH (SHF1). Core Identification Pair: White/blue with printed pair number and core number. IEC Standard Caledonian Offshore & Marine Cables MariSig Fire Resistant Instrumentati Bending Radius for Fixed Installations: 6X OD ‘Temperature Range: -30°C ~ +75°C ve ciation] Reiter staat Aer! Overt] Neal Pat Tice Danser Wet Ee ene ea ee a cn) a *: 2 pairs are assembled as a quad. d waaddson-24— Bulaxa4AnG) 034 ie IEC Standard Caledonian Offshore & Marine Cables in Data & Communication Cables DE Cat 7 S/FTP 0.27 mm? Application These Cat7 S/FTP cables are manufactured in accordance with IEC 61156-5 requirements, can support all Class F applications like Ethernet, Fast Ethernet, Gigabit Ethernet, suitable for voice, data, CATV and sharing application installations up to 60OMHz. Standards ‘Stranded Copper Conductor + EN650173-1 PE Insulation Alpolyaster Tape + EN50288-4-1 Tine Copper raid * ISO/IEC 11801 LSOH (SHF1) Outer Sheath + IEC 61156-5 * IEC 60332-3-24 + IEC 607542 + IEC 61034 Construction Conductors: Stranded copper conductor. Insulation: PE. Twinning: Two coloured insulated conductors twisted together to form a pair. Individual Screen: Al/polyester tape. Overall Screen: Tinned copper wire braid. Outer Sheath: Oil resistant, flame retardant and halogen free LSOH (SHF1). Core Identification Pair 1: White, Blue Pair 2: White, Orange Pair 3: White, Green Pair 4: White, Brown IEC Standard Caledonian Offshore & Marine Cables MariLan Marine Lan Data & Comi Electrical Properties ‘Maximum DC Loop Resistance ‘Maximum Resistance Unbalance Minimum Insulation Resistance (500V) Nominal Capacitance @800Hz Maximum Capacitance Unbalance (pair to ground) ‘Mean Characteristic Impedance @100MHz ‘Nominal Velocity of Propagation Maximum Propagation Delay Maximum Delay Skew Maximum Transfer Impedance @1MHz Maximum Transfer impedance @ 10MHz Maximum Transfer Impedance @30MHz Minimum Coupling Attenuation Nominal Transmis: F Maz 10 16 20 31,25 625 100 155.0 200.0 250.0 300.0 600.0 ‘Attenuation ai100m 20 36 55 75. 77 98 140 179 224 258 288 318 45.7 ‘uke Ma.km Fim Fim a ris/100 m rns/100 m maim maim maim 8 NEXT ACR Retum Loss dB dB100m = B 20 88 90 86 2 20 34 30 20 82 30 20 82 30 90 80 30 85 2 30 83 65 30 at 59 26 8 52 25 7 48 25 73 41 23 mn 25 20 Mechanical and Thermal Properties Bending Radius: 8 OD (during installation); 4 OD (fixed installed) ‘Temperature Range: -40°C ~ +85°C MLN-SIFTPCAT74P27S Part No. mensions and Weight (Construction No. of elementsxNo. of cores in elementxCross section(mm) 4x2x0.27 Nominal Insulation Thickness 047 oB a7 87 a7 37 87 87 83 80 7 5 4 70 8 ‘Nominal Sheath Nominal Overall n Characteristics @20°C PS.NEXT | PS-ACR B/100m 85 83 at 73 73 7 69 62 55 49 45 38 2 Thickness mm 7s 138 2% +5000 43 1500 100+ 5 0.760 450 1 1 1 5 10 10 85 ELFEXT 8/100m 85 85, 79 75 3 68 63 59 57 53 51 47 “4 Diameter mm aa PS-ELFEXT 8/100m, 82 82 78 SSRBSSaRn ait Nominal Weight kai 5 IEC Standard Caledonian Offshore & Marine Cables in Data & Communication Cables DE Mud Resistant Cat 7 S/FTP 0.27 mm? Application These Cat? S/FTP cables are manufactured in accordance with IEC 61156-5 requirements, can support all Class F applications like Ethernet, Fast Ethernet, Gigabit Ethernet, suitable for voice, data, CATV and sharing application installations up to 600MHz. These cables have additional flame retardant, halogen-free, low smoke MUD protecting outer sheaths. Standards MUD Protection Standed Copper Conductor © EN50173+1 PE Insulation © EN 50288-4-1 Tero Copper Braid * ISO/IEC 11801 LSOH (SH) Outer Sheath * IEC 61156-5 * IEC 60332-3-24 * IEC 60754-2 « IEC 61034 Construction Conductors: Stranded copper conductor. Insulation: PE. ‘Twinning: Two coloured insulated conductors twisted together to form a pair. Individual Screen: Al/polyester tape. Overall Screen: Tinned copper wire braid Inner Sheath: Oil resistant, flame retardant and halogen free LSOH (SHF 1). Outer Sheath: MUD protecting Core Identification Pair 1: White, Blue Pair 2: White, Orange Pair 3: White, Green Pair 4: White, Brown IEC Standard Caledonian Offshore & Marine Cables MariLan Marine Lan Data & Comi Electrical Properties ‘Maximum DC Loop Resistance ‘Maximum Resistance Unbalance Minimum Insulation Resistance (500V) ‘Nominal Capacitance @800Hz Maximum Capacitance Unbalance (pair to ground) ‘Mean Characteristic Impedance @100MHz ‘Nominal Velocity of Propagation ‘Maximum Propagation Delay Maximum Delay Skew ‘Maximum Transfer Impedance @1MH2 ‘Maximum Transfer Impedance @10MHz ‘Maximum Transfer Impedance @30MHz ‘Minimum Coupling Attenuation ‘ik Makm ‘nFikm pF/km a 1is/100 m rns/100 m ‘maim ‘maim ‘maim B Nominal Transmission Characteristics @20°C F Miz 1 4 10 16 20 31.28 62.5 100 155.0 200.0 250.0 300.0 600.0 ‘Attenuation dB/100m 20 36 55 75 77 98 140 179 224 256 28.8 316 45.7 NEXT cy 90 90 90 90 90 90 86 33 at 78 7 73 m1 ACR B/i00m 88 86 84 22 82 80 7 65 59 52 48 a 25 Mechanical and Thermal Properties Bending Radius: 8X OD (during installation); 4x OD (fixed installed) Temperature Range: -40°C ~ +85°C Dimensions and Weight MLN-SIFTPCAT7M4P27S PartNo. Construction No, of elementsXNo, of cores in elementxCross ‘section(mn) 4x2%0.27 Nominal Insulation Thickness 047 Retum Loss | PS-NEXT dB dB 87 2 87 30 87 30 87 30 87 30 87 30 83 30 80 26 78 25 75 25 4 23 70 20 68 PS-ACR

You might also like