Nr. Pump for Spinbath

Storage tank

Storage tank + 15 m

Storage tank
Pump-1
DN 350 DN 250 Bottom tank
+ 1.0 m
Storage tank

+ 1.0 m

Note: All the liquids can contain bagacillo, rust, sand or scale particles

Basic design data unit


Medium:
Mass flow [t/h] 450.00
Density [t/m3] 1.330
Temperature [°C] 45.0
Dynamic viscosity [Pa s] 0.000890
Length of pipe [m] approx. 200.0
Height of intake [mLC] 0.50
Pressure (inlet suction side) [bar] 1.00
Pressure (outlet pressure side) [bar] 1.00
Geodetic head [mLC] Top Rack 15.0

Calculation of fluid velocity and pipe size Load factor 100% 100%

Volume flow rate [m3/h] 338.3 338.3


Velocity (set value) [m/s] 1.8 1.80
Pipe size (theoretical) [mm] 258 258
Chosen pipe size [mm] 250.0 250
Calculated velocity [m/s] 1.91 1.91

Calculation of delivery head Load factor 100% 100%

Pressure drop in the pipe [mLC] 3.35 3.35


Pressure drop of fittings, valves, etc. [Ceta ] 15.0 15.00
[mLC] 3.66 3.66
Pressure drop of china filter [bar] 0.0 0.00
[mLC] 0.00 0.00
Pressure drop of control valve [mLC] 0.00 0.00
Pressure (outlet pressure side - inlet suction side) [bar] 0.00 0.00
[mLC] 0.00 0.00
Geodetical head [mLC] 15.00 15.00
Theoretical delivery head [mLC] 22.00 22.00
Safety addition [mLC] 1.00
Chosen delivery head [mLC] 23.00
[bar] 3.00
Remark: Without frequency convertor

Design data of the pump


Maximum volume flow rate [m³/h] 338
Delivery head [mLC] 23
NPSH (net positive suction head) of the plant [mLC] 7.16
mech. Leistung an der Welle (geschätzt) [KW] 37.6
Spinbath pump, 31-01-2020, JS