PROTECTIVE RELAYS

IPSplot® PLUS
Oscillograph Analysis
Software M-3801D
IPSPlot PLUS
OSC File View Settings Window Help

RMS 1st ƒ P PF PQ
Va (V) Phase
-323.0 Diagram
169.7 X

Phasors: 0
+30 –30
Phase Magnitude Angle
Va 120.0 0°
131.0 160.0
Vb -169.7
120.0 -118°
+60 –60
Vb (V) Vc
141.0 120.1
169.8 121°
VG 0.0 0°
V2 0.0 0°
IA 8.00 -44° +90 –90 Phasor display shown at
IB 4.99 65° Marker #1 Location
IC 5.00 -54°
29.6 -29.1 -169.8
IG 0.00 0°
Vc (V) 182.2 169.8
+120 –120

+150 –150

+180
-159.0 -130.5 -169.8

IA(A) 4.21 11.34

Phasor diagram with


values displayed
11.26 7.07 -11.34
IB(A) 1.81 7.19

-1.79 -3.61 -7.19

IC(A) 10.25 7.17

6.77 -3.48 -7.17


1308 1212 1200 1250 1300 1350 1400
Ready Date: 01/01/2003 Start Time: 01:01:17.589 Tripped Time: 01:01:20.000 Mark 1: 01:01:17.589 Mark2: 01:01:17.589 NUM

• Provides a quick and easy-to-use commissioning


and forensic engineering tool
• Analyze data in both the time and phasor
domains simultaneously

• Observe the phasor, impedance, and PQ plots


change dynamically

• Easily view and analyze harmonic quantities


(2nd, 3rd, 4th, and 5th)

Industry Leader Since 1969


Made in the USA
M-3801D IPSplot PLUS Oscillograph Analysis Software

The M-3801D IPSplot® PLUS Oscillograph Analysis Software operates in conjunction with all IPScom® Communications
Software on any IBM PC-compatible computer. IPSplot PLUS allows the user to plot and print waveform data
downloaded from Beckwith Electric Integrated Protection Systems (IPS). IPSplot PLUS is also capable of plotting
and printing waveform data files in COMTRADE format, including files downloaded from the HandspringTM VisorTM or
Palm® Handheld.

Installation and Setup


IPSplot PLUS operates under the Microsoft Windows operating system, version 95/98 or later, and is available on
CD-ROM.

Overview
When IPSplot PLUS is started, a menu and tool bar are displayed (see Figure 2). This brochure describes each
IPSplot PLUS menu selection and explains each IPSplot PLUS command in the same order that they are displayed in
the software program. When starting IPSplot PLUS, the menu commands that are initially available are File/Open (to
open a file to be analyzed) and File/Print Setup (to identify the target printer).

IPSPlot PLUS - [M3XXX:C:\Test2.osc]


OSC File View Settings Window Help

RMS 1st ƒ P PF PQ
Va (V) -220.0 169.7

-100.2 119.7 -169.7

Vb (V) -109.8 169.8

-66.9 43.0 -169.8

Vc (V) 327.3 169.8

165.6 -161.6 -169.8

VG (V) 0.0 0.5

-0.1 -0.1 -0.5

V2 (V) -0.1 0.5

-0.1 -0.0 -0.5

IA (A) -7.37 11.34

3.73 11.09 -11.34


IB (A) -5.55 7.19

3.23 -2.31 -7.19

IC (A) -13.78 7.17

-6.96 6.82 -7.17


IG (A) -0.02 0.50

-0.03 -0.01 -0.50

0 0 1289
In1
0.00 In2
0.00 cycles In3
In4
In5
In6
Out1
Out2
Out3
Out4
Out5
Out6
Out7
Out8

Ready Date: 01/01/2003 Start Time: 01:01:17.589 Tripped Time: 01:01:20.000 Mark 1: 01:01:17.589 Mark2: 01:01:17.589 NUM

Q NOTE: Cursor bars may be dragged to any location by positioning the cursor arrow on a bar and dragging the
mouse. Double click the left key to position one cursor bar and Shift-Double Click or left mouse down and
click the right key to position the other cursor bar at the current cursor arrow time position.

Figure 1 Example of IPSplot PLUS Oscillographic Data

–2–
M-3801D IPSplot PLUS Oscillograph Analysis Software

IPSplot PLUS X
File Edit View Settings Window Help

Help
Window
Contents
Cascade
File About IPSplot
Arrange Icons
Open... Ctrl+O
(Windows File Path) M34XX Select Waveforms X
Close
Analog Input Output
Print Ctrl+P
o Va o In1 o Out1
Print Preview o Vb o In2 o Out2
o Vc o In3 o Out3
Print Setup... o Vg o In4 o Out4
o Vx o In5 o Out5
1 Test.osc o IA o In6 o Out6
o IB o Out7
Exit o IC o Out8
o IG

Settings Clear All Select All Clear All Select All Clear All Select All

Select Waveform
Select Color Cancel OK
Change Scale

M34XX Select Color X

System Color:
View Foreground
Selected Bar 1
Primary Selected Bar 2
Tripped Bar
Original Waveform Time Label Change
Frequency
Frequency
Power
RMS Value Input Background
Power Output
Vab
Power Factor
Vbc
Zero Sequence Current Vca Change
Vg
Tripped Functions
Device Information
Apply Cancel OK
Fundamental Magnitude
2nd Harmonic Magnitude
3rd Harmonic Magnitude
4th Harmonic Magnitude M34XX: Change Scale X

5th Harmonic Magnitude Channel Scale:

Name Unit Max Min Default


Impedance Diagram VA (V) 0.5 0.0

Phase Diagram VB (V) 0.5 0.0 Auto All


VC (V) 0.5 0.0
Max
PQ Diagram VX (V) 0.5 0.0
VN (V) 0.5 0.0
IA (A) 0.50 0.00
Zoom In + IB (A) 0.50 0.00 Auto
Zoom Out – IC (A) 0.50 0.00
IN (A) 0.50 0.00
View All Ia (A) 0.50 0.00 Min
Ib (A) 0.50 0.00
Toolbar Ic (A) 0.50 0.00

Status Bar Auto

Apply Cancel OK

Figure 2 Settings Submenu Callouts

–3–
M-3801D IPSplot PLUS Oscillograph Analysis Software

File Menu
File
Open... Ctrl+O
Close

Print Ctrl+P
Print Preview
Print Setup...

1 Test.osc

Exit

The File menu allows the user to open an oscillograph file previously downloaded by IPScom®. It supports both
Beckwith oscillograph files (file extension *.osc) and COMTRADE format data files (file extension *.cfg). The File
menu also permits the user to preview and print selected oscillographs. Exit closes the IPSplot PLUS program.

View Menu
View
Primary

Original Waveform
Frequency
RMS Value
Power
Power Factor
Zero Sequence Current

Tripped Functions
Device Information

Fundamental Magnitude
2nd Harmonic Magnitude
3rd Harmonic Magnitude
4th Harmonic Magnitude
5th Harmonic Magnitude

Impedance Diagram
Phase Diagram
PQ Diagram

Zoom In +
Zoom Out –
View All

Toolbar
Status Bar

The View menu allows the user to select time domain waveforms, and allows phasor domain diagrams to be
displayed. Several of these items may also be activated by selecting the corresponding toolbar icon.

–4–
M-3801D IPSplot PLUS Oscillograph Analysis Software

Settings Menu
Settings
Select Waveform
Select Color
Change Scale

The Settings menu allows the selection of the waveforms to be displayed, the formatting of display colors, and the
ability to change the waveform scaling.
Select Waveforms allows the selection of voltages, currents, inputs, and outputs to be plotted or printed.

M3XXX: Select Waveforms X

Analog Input Output

o Vab o In1 o Out1


o Vbc o In2 o Out2
o Vca o In3 o Out3
o Vg o In4 o Out4
o IA o In5 o Out5
o IB o In6 o Out6
o IC o Out7
o IG o Out8
o Ia
o Ib
o Ic

Clear All Select All Clear All Select All Clear All Select All

Cancel OK

Figure 3 Select Waveforms Dialog Box

Change Colors allows the user to change waveform colors for customized plotting.

M3XXX: Select Color X

System Color:
Foreground
Selected Bar 1
Selected Bar 2
Tripped Bar
Time Label Change
Frequency
Power
Input Background
Output
Vab
Vbc
Vca Change
Vg

Apply Cancel OK

Figure 4 Change Colors Dialog Box

–5–
M-3801D IPSplot PLUS Oscillograph Analysis Software

Change Scale allows the individual designation of a magnitude scale for voltage and current traces.
Default sets all similar waveforms to the same scale (largest).
Auto All allows IPSplot® PLUS to set the scale for each individual waveform.

M34XX: Change Scale X

Channel Scale:

Name Unit Max Min


Default
VA (V) 0.5 0.0 Auto All
VB (V) 0.5 0.0
VC (V) 0.5 0.0 Max
VX (V) 0.5 0.0
VN (V) 0.5 0.0
IA (A) 0.50 0.00
IB (A) 0.50 0.00 Auto
IC (A) 0.50 0.00
IN (A) 0.50 0.00
Ia (A) 0.50 0.00 Min
Ib (A) 0.50 0.00
Ic (A) 0.50 0.00

Auto

Apply Cancel OK

Figure 5 Change Scale

Window Menu/Help Menu


Window
Cascade
Arrange Icons
(Windows File Path)

The Window menu enables the positioning and arrangement of multiple IPSplot PLUS windows at the same time.
Selecting any displayed window activates that frame, allowing manipulation of the data.

Help
Contents
About IPSplot PLUS

The Help menu provides information about IPSplot PLUS menus and commands. The About command provides
version information for IPSplot PLUS.

–6–
M-3801D IPSplot PLUS Oscillograph Analysis Software

RMS 1st ƒ P PF PQ
Open Move
Print Left Move Zoom In View All RMS Phase PQ
Right Waveform Frequency Diagram Diagram
Move to the Move to the Zoom Out Original Waveform
Beginning Power Factor
End Waveform Waveform
Fundamental
Waveform Power
Waveform Impedance
Diagram

Figure 6 IPSplot® PLUS Toolbar

IPSPlot PLUS - [M3XXX:C:\Test2.osc]


OSC File View Settings Window Help

RMS 1st ƒ P PF PQ
Va (V) -220.0 169.7

-100.2 119.7 -169.7


Vb (V) -109.8 169.8

-66.9 43.0 -169.8


Vc (V) 327.3 169.8

Marker #1
165.6 -161.6 -169.8
All analog traces. This
VG (V) 0.0 0.5
view shows peak values.
RMS values may Marker #2
-0.1 -0.1 -0.5 also be displayed.
V2 (V) -0.1 0.5

-0.1 -0.0 -0.5


IA (A) -7.37 11.34 Delta value between
Marker #1 and
3.73 11.09 -11.34
Marker #2
IB (A) -5.55 7.19
Value at Marker #1

3.23 -2.31 -7.19


IC (A) -13.78 7.17
Value at Marker #2

-6.96 6.82 -7.17


IG (A) -0.02 0.50 Scaling for each analog trace.
This can be set automatically,
or manually adjusted.
-0.03 -0.01 -0.50
1281 1289 1240 1260 1280 1300 1320 1340
In1
000.00 ms In2
00.00 cyles In3
Time at In4
In5
Date and Timestamp Time of Trip Time at Marker #1 Time at Marker #2
Marker #2 In6 for record Command
Time at Out1 Control status input
Marker #1 Out2
Out3
and contact output
Out4 traces (discrete I/O)
Out5
Out6
Out7
Out8

Ready Date: 01/01/2003 Start Time: 01:01:17.589 Tripped Time: 01:01:20.000 Mark 1: 01:01:17.589 Mark2: 01:01:17.589 NUM

Q NOTE: Cursor bars may be dragged to any location by positioning the cursor arrow on a bar and dragging the
mouse. Double click the left key to position one cursor bar and Shift-Double Click or double click the right
key to position the other cursor bar at the current cursor arrow time position.

Figure 7 IPSplot PLUS Screen with Callouts

–7–
IPSplot® PLUS makes use of shortcut key commands for many functions, making IPSplot PLUS as easy as
clicking your mouse and touching a few keys.

Ke y Stroke s Action

Left- Mouse button down and drag, or select zoom Magnify the selected area in main display, impedance
in icon on toolbar menu diagram, PQ diagram, and phasor diagrams

Left- mouse double click Move Marker #1 to current position in main display

Shift + Left- mouse double- click or left- mouse


Move Marker #2 to current position in main display
down and right- mouse double click

Align cursor on Marker #1 and drag Drag Marker #1 in main display

Align cursor on Marker #2 and drag Drag Marker #2 in main display

Current and voltage selection menu in main display and


phasor diagrams
Right- mouse down Impedance in the Impedance diagram
Voltage and Current in the Phase diagram
Real and Reactive Power in PQ diagram

Left key or select left scroll icon in toolbar menu Move left in main display

Right key or select right scroll icon in toolbar menu Move right in main display

Home key or select move to beginning icon in


Move to the beginning of the record in the main display
toolbar menu

End key or select move to end icon in toolbar


Move to the end of the record in the main display
menu

Table 1 Shortcut Keys

Patent and Warranty


The M-3801D IPSplot PLUS software is covered by a five year warranty from date of shipment.

Specification is subject to change without notice.

BECKWITH ELECTRIC CO., INC.


6190 - 118th Avenue North • Largo, Florida 33773-3724 U.S.A.
PHONE (727) 544-2326 • FAX (727) 546-0121
marketing@beckwithelectric.com
www.beckwithelectric.com
ISO 9001:2008
© 2003 Beckwith Electric Co. All Rights Reserved.
800-3801D-SP-02MC2 01/13
Printed in USA

You might also like