Electrical Production line 12/24h 460/60HZ

wiring diagram
Ref Created: Last modified
== ++ Page: No

LHO 02-06-2016 19-03-2020 = GEN + CP 10 / 32 008-1076


¤H-K1.3 LOCAL:
=STOCK+PULP/1.3
=STOCK+PMPFL/1.1 1 BK
=STOCK+PMPFL/6.5DC_COM1 /5.3
3 RD
=STOCK+PMPFL/9.3DC_COM1 /5.3
=STOCK+CLNFL/1.1
=VACWT+VAC/1.2 5 OR
3:I.0 =MM+DRYER/1.2 +MM-P1 Wire, layer 1, upper
=VACWT+VAC/6.2 7 WH|BK
=MM+TD1/3.6 3:I.1 =MM+DRYER/1.3 -T48:L+ Wire, layer 2
9 GN|BK
=MM+MM/3.7 3:I.2 =MM+DRYER/1.3 +DRYER-B41.1:-B41.1 Wire, layer 3
=MM+MM/8.8 11 BU|BK
3:I.3 =MM+DRYER/1.4 +DRYER-B41.2:-B41.2 Wire, layer 4
=MM+DRYER/1.1 13 RD|WH
3:I.4 =MM+DRYER/1.5 +DRYER-B41.3:-B41.3 Wire, layer 5
=DRYING+AH/3.5 15 BU|WH
3:I.5 =MM+DRYER/1.5 +DRYER-B41.4:-B41.4 Wire, layer 6
=DRYING+AH/4.4 17 WH|RD
=DRYING+AH/5.5 3:I.6 =MM+DRYER/1.6 +DRYER-B41.5:-B41.5 Wire, layer 7
19 BU|RD
=DRYING+AH/8.1 3:I.7 =MM+DRYER/1.7 +DRYER-B41.6:-B41.6 Wire, layer 8
=AP2+TD3/1.6
/5.3 21 OR|GN
3:I.8 =MM+DRYER/1.8 +DRYER-B41.7:-B41.7 Available connections for alarm wires in dryer
32 * DIGITAL IN 23 WH|BKRD
3:I.9 =MM+DRYER/1.8 +DRYER-B41.8:-B41.8 Available connections for alarm wires in dryer
25 GN|BKWH =AP2+CP_AP2/1-20 Sensor fuera, cilindro tobogán a apilado
3:I.10
27 BU|BKWH
3:I.11 =VACWT+VAC/6.2 +AH-B356 Level in scrubber below setpoint
29 WH|RDGN
3:I.12 =X1.3 Confirmación agitador hummificador
31 GN|BKOR
3:I.13 =X5.19 LIBRE
33 BU|WHOR
3:I.14 =X5.21 LIBRE
35 WH|RDOR
3:I.15 =X5.25 LIBRE

37 WH|RDBU
DC_COM2 /5.3
39 WH|BKGN
DC_COM2 /5.3

2 WH
DC_COM3 /5.3
4 GN
DC_COM3 /5.3

6 BU
3:I.16 =X1.62 LIBRE
8 RD|BK
Color code refers to pre manufactured cable,

3:I.17 =MM+MM/3.7 +CS2-SP02:14 Reset interlock moulding machine on CS2


10 OR|BK
3:I.18 =MM+MM/3.9 +CS2-S10:12 Quick stop moulding machine on CS2
12 BK|WH
3:I.19 =MM+MM/8.9 +MM-QM10:14 Motor circuit breaker for main drive
14 GN|WH
3:I.20 =X1.14 LIBRE
16 BK|RD
3:I.21 =X1.15 LIBRE
18 OR|RD
3:I.22 =X1.16 LIBRE
20 RD|GN
(The stripe may be 2-colored).

3:I.23 =X1.17 LIBRE

22 BK|WHRD
3:I.24 =AP2+CP_AP2/1-20 Selector cambio tobogán
24 RD|BKWH
type 1492 CABLE -- N3

3:I.25 =AP2+TD3/1.6 +TD3-M93-K1:b Belt at tipping device ready


Base color|Stripe color

26 OR|BKWH
3:I.26 =AP2+CP_AP2/1-20 Sensor adentro cilindro tobogán a apilado
28 BK|RDGN
3:I.27 =DRYING+AH/4.4 +CPAH-K11:24 Monitoring circulation blower
30 RD|BKGN
3:I.28 =DRYING+AH/5.6 +CPAH-K21:24 Monitoring exhaust air fan
32 OR|BKGN
3:I.29 =DRYING+AH/8.1 +CPAH-K31:14 Burner in operation
34 BK|WHOR
3:I.30 =DRYING+AH/8.3 +CPAH-K33:14 Burner failure
36 OR|WHBU
3:I.31 =MM+TD1/3.7 -QF62:14 Monitoring hot air blower for heat jacket

38 BK|WHGN
DC_COM4 /5.3
40 RD|WHGN
DC_COM4 /5.3