Electrical Production line 12/24h 460/60HZ

wiring diagram
Ref Created: Last modified Page: No

LHO 02-06-2016 20-03-2020 = GEN + CP 11 / 32 008-1076


== ++

¤H-K1.4 LOCAL: ¤H-K1.5 LOCAL:


=STOCK+PULP/2.5 =MM+TD1/2.0
=STOCK+PULP/4.4 1 BK =MM+TD1/3.1 1 BK
=STOCK+PULP/5.5 +VDC1 /5.4 =MM+MM/6.5 +VDC1 /5.4
3 RD 3 RD
=STOCK+PULP/6.3 +VDC1 /5.4 =MM+MM/8.2 +VDC1 /5.5
=STOCK+PULP/6.5 =MM+MM/11.4
=STOCK+PMPFL/2.5 5 OR =XK1.18 LIBRE =MM+MM/13.2 5 OR
4:O.0 5:O.0 =MM+MM/8.3 -T10:18 Main drive moulding machine, start / run
=STOCK+PMPFL/3.5 7 WH|BK =TOMA 110V Piloto BBA colorante =MM+MM/14.0 7 WH|BK
=STOCK+PMPFL/4.4 4:O.1 =MM+MM/14.5 5:O.1 =MM+MM/8.3 -T10:33 Main drive moulding machine, jog
9 GN|BK =X1.90 Válvulas hummificador 9 GN|BK
=STOCK+PMPFL/10.3 4:O.2 =MM+MM/15.5 5:O.2 =MM+MM/6.6 +PB2-Q13 Brake on main drive, free if power off
=STOCK+PMPFL/15.5 11 BU|BK =X1.91 Agitador hummificador =MM+MM/16.0 11 BU|BK
4:O.3 5:O.3 =MM+MM/14.1 +PB2-Q77 Pneumatic pump for oil spraying on dies
=STOCK+PMPFL/16.3 13 RD|WH =DRYING+AH/4.0 13 RD|WH =X1.86 LIBRE
4:O.4 =X1.39 LIBRE 5:O.4
=STOCK+PMPFL/17.3 15 BU|WH =DRYING+AH/5.0 15 BU|WH
4:O.5 =X1.8 LIBRE 5:O.5 =MM+MM/6.5 +PB2-Q15 Lubrication on moulding machine
=STOCK+PMPFL/18.2 17 WH|RD =DRYING+AH/7.0 17 WH|RD
=STOCK+CLNFL/2.5 4:O.6 =X1.40 LIBRE =DRYING+AH/8.0 5:O.6 =MM+TD1/2.0 -K16:A1 Enable lubrication on dryer chain
19 BU|RD 19 BU|RD
=STOCK+CLNFL/3.6 4:O.7 =X1.9 LIBRE /5.4 5:O.7 =MM+TD1/2.2 -K18:2 Enable lubrication on carrier rod
=STOCK+CLNFL/4.5 32 * DIGITAL OUT
=VACWT+PMPFL/1.4 21 OR|GN 21 OR|GN
4:O.8 =X1.52 LIBRE 5:O.8 =MM+MM/16.1 +MM-P1:1 Alarm, lamptower at moulding machine
=VACWT+PMPFL/2.5 23 WH|BKRD 23 WH|BKRD
=VACWT+PMPFL/3.5 4:O.9 =X1.53 LIBRE 5:O.9 =MM+MM/16.3 +MM-P1:5 Warning
25 GN|BKWH =X1.110 LIBRE 25 GN|BKWH
=VACWT+VAC/4.2 4:O.10 5:O.10 =MM+MM/16.3 +MM-P1:4 Error /fault
=VACWT+VAC/5.5 27 BU|BKWH 27 BU|BKWH
4:O.11 =X1.40 LIBRE 5:O.11 =MM+MM/16.2 +MM-P1:3 Running
=VACWT+VAC/6.5 29 WH|RDGN 29 WH|RDGN
4:O.12 =XK1.7 LIBRE 5:O.12 =MM+MM/16.1 +MM-P1:2 Ready
=VACWT+AH/1.0 31 GN|BKOR 31 GN|BKOR
4:O.13 =X1.42 LIBRE 5:O.13 =X1.85 LIBRE
=VACWT+OUTS/1.4 33 BU|WHOR 33 BU|WHOR
=MM+MM/10.3 4:O.14 =X1.5 LIBRE 5:O.14 =MM+MM/13.7 -QF60:A1 Hydraulic pump for lifting heat jacket
/5.4 35 WH|RDOR 35 WH|RDOR
4:O.15 =XK1.9 LIBRE 5:O.15 =MM+MM/13.3 +MM-Q61:x1 Hydraulic valve for lowering
32 * DIGITAL OUT
37 WH|RDBU 37 WH|RDBU
DC_COM1 /5.4 DC_COM1 /5.4
39 WH|BKGN 39 WH|BKGN
CD_COM1 /5.4 CD_COM1 /5.5

2 WH 2 WH
+VDC2 /5.4 +VDC2 /5.5
4 GN 4 GN
+VDC2 /5.4 +VDC2 /5.5

6 BU 6 BU
4:O.16 =VACWT+PMPFL/1.5 -T204:18 Enable white water pump at vacuum tank 5:O.16 =MM+MM/11.5 +PB2-Q33 Vacuum eliminator
8 RD|BK 8 RD|BK
Color code refers to pre manufactured cable,

Color code refers to pre manufactured cable,


4:O.17 =X1.6 Alarma de conteo efectivo 5:O.17 =MM+MM/11.6 +PB2-Q34 Blow off reject mode
10 OR|BK 10 OR|BK
4:O.18 =VACWT+VAC/4.3 +Q112-TM:N2 Soft starter for vacuum pump on 5:O.18 =MM+MM/11.6 +PB2-Q35 Normal vacuum and blow-off, close (recect)
12 BK|WH 12 BK|WH
4:O.19 =STOCK+PMPFL/18.2 -K216_217:A1 Dosing pumps for polymin and afranil to stock 5:O.19 =X1.87 LIBRE
14 GN|WH 14 GN|WH
4:O.20 =STOCK+PMPFL/17.3 Válvula TKC 5:O.20 =MM+MM/11.8 +PB2-Q37 Emptying valve, chest to reject
16 BK|RD 16 BK|RD
4:O.21 =VACWT+VAC/5.6 -QF208:A1 Motorstarter, pump for cooling tower 5:O.21 =MM+MM/11.9 +PB2-Q38 Switch to high blow-off pressure
18 OR|RD 18 OR|RD
4:O.22 =VACWT+PMPFL/2.5 -QF214:A1 Motorstarter for flushing water pump 5:O.22 =X1.84 LIBRE
20 RD|GN 20 RD|GN
(The stripe may be 2-colored).

(The stripe may be 2-colored).


4:O.23 =VACWT+AH/1.0 +CPAH-QF210:A1 Motorstarter for hot water pump, return from scrubber 5:O.23 =MM+MM/15.5 -QF79:A1 Motor starter for oscillation

22 BK|WHRD 22 BK|WHRD
4:O.24 =VACWT+VAC/6.5 -QF209:A1 Motorstarter, pump for supply to scrubber 5:O.24 =MM+MM/14.6 -T70:18 Die cleaner brush start / run
24 RD|BKWH 24 RD|BKWH
type 1492 CABLE -- N3

type 1492 CABLE -- N3


4:O.25 =STOCK+PMPFL/16.4 -T205:18 Enable stock feeding pump for moulding machine 5:O.25 =MM+MM/14.6 -T70:19 Die cleaner brush reverse
Base color|Stripe color

Base color|Stripe color


26 OR|BKWH 26 OR|BKWH
4:O.26 =STOCK+PMPFL/17.4 -T206:18 Válvula regaderas 5:O.26 =DRYING+AH/4.1 +CPAH-K10:A1 Circulation blower on
28 BK|RDGN 28 BK|RDGN
4:O.27 =STOCK+PMPFL/4.4 -T207:18 Enable dilution water pump for cleaning equippment 5:O.27 =DRYING+AH/5.1 +CPAH-K20:A1 Exhaust air fan on
30 RD|BKGN 30 RD|BKGN
4:O.28 =X1.7 LIBRE 5:O.28 =DRYING+AH/7.0 +CPAH-K30:A1 Burner on
32 OR|BKGN 32 OR|BKGN
4:O.29 =MM+MM/10.3 +PB2-Q30 Main valve for blow off air 5:O.29 =DRYING+AH/8.0 +CPAH-K32:A1 Reset-burner
34 BK|WHOR 34 BK|WHOR =M6.2-3
4:O.30 =MM+MM/10.8 +MM-Q322 Main valve for vacuum 5:O.30
36 OR|WHBU 36 OR|WHBU
4:O.31 =VACWT+OUTS/1.5 -QF113:A1 Motorstarter for fan in cooling tower 5:O.31 =MM+TD1/3.2 -QF62:A1 Motor starter and damper, hot air blower for heat jacket

38 BK|WHGN 38 BK|WHGN
DC_COM2 /5.4 DC_COM2 /5.5
40 RD|WHGN 40 RD|WHGN
DC_COM2 /5.4 DC_COM2 /5.5
0 1 2 3 4 5 6 7 8 9