 Load case for min. ambiant Temperature? #34672 ­ 04/29/10 02:53 AM

Shahram78  Go
  Hi, Advanced
 
 
Member   
In my current project, the ambient temp. of piping installation yard is
    Who's Online
T=21°C which I used it as the ambient temp. in CAESAR. 
Registered:  
10/01/09  The max design temp. is T1=80°C (ΔT1=80­21=59°C) and the min. 1 registered (sharu),
Posts: 10   ambient temp. of plant is T2=­36°C (ΔT2=21­(­36)=57°C).  44 Guests and 2
Loc: AU All load cases now are according to T1 which cause a bigger   Spiders online.
temperature variation. Key: Admin, Global Mod,
    Mod
Could anybody say me that I have to add any new load cases for T2
(since during plant shutdown it will be the case) or I’m in safe range March
now? Su M Tu W Th F Sa
   
Kind regards. 1 2
    3 4 5 6 7 8 9
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post 10 11 12 13 14 15 16
17 18 19 20 21 22 23
 Re: Load case for min. ambiant Temperature? [Re: #34673 ­ 04/29/10 04:07 AM
Shahram78] 24 25 26 27 28 29 30

khatkole    31
Member    you have to check at ­36 c also by simply taking new file in that you
    Forum Stats
have to take ­36 as a ambient
Registered:
11627 Members
04/28/08  _________________________ 14 Forums  
Posts: 31    
Loc: India Mumbai  
15774 Topics
India   70856 Posts  
     
Max Online: 126 @
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post
05/09/18 04:29 PM

 Re: Load case for min. ambiant Temperature? [Re: #34679 ­ 04/29/10 07:35 AM
Shahram78]
Dave Diehl 
  L1: W+T1+(whatever else is operating case 1)
    L2: W+T2+(whatever else is operating case 2) 
 
Member   
L3: W+P?+(whatever else is considered a sustained force effect)
    L4: L1­L2 (EXP)  
Registered:  
 
12/14/99 
 
Posts: 2355  L4 is your strain range. Not ambient to hot; not ambient to cold ­ but
Loc: Houston, TX, hot to cold. If using B31.3, read 319.2.3(b).
USA
_________________________
Dave Diehl  
 

 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: Load case for min. ambiant Temperature? [Re: Dave #34682 ­ 04/29/10 11:49 AM
Diehl]

Chakot   
Member    Dave, I am not sure I would do like you said.
 
  What about to change case 4 as following?  
Registered:  
05/01/09   

http://forums.coade.com/ubbthreads/ubbthreads.php?ubb=showflat&Number=34684&Searchpage=11&Main=7600&Words=constant&Search=true#Post34684 1/4
12/03/2019 Load case for min. ambiant Temperature? - Intergraph CADWorx & Analysis
Posts: 60  L4: L1­L3 (EXP)
Loc: Italy L5: L2­L3 (EXP) 
   
Thank you.
 
Originally Posted By: Dave Diehl

L1: W+T1+(whatever else is operating case 1)
L2: W+T2+(whatever else is operating case 2) 
 
L3: W+P?+(whatever else is considered a sustained force
effect)
 
L4: L1­L2 (EXP)
   
L4 is your strain range. Not ambient to hot; not ambient to
cold ­ but hot to cold. If using B31.3, read 319.2.3(b).
 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: Load case for min. ambiant Temperature? [Re: #34684 ­ 04/29/10 12:03 PM
Chakot]
Dave Diehl 
  Here's what B31.3 paragraph 319.2.3(b) says:
     
... "the algebraic difference between strains in the extreme displacement
 
Member  condition and the original (as­installed) condition (or any anticipated
    condition with a greater differential effect) remains substantially
Registered:
constant during any one cycle of operation. This difference in strains
12/14/99 
 
Posts: 2355  produces a corresponding stress differential, the displacement stress
Loc: Houston, TX, range, which is used as the criterion in the design of piping for
USA flexibility."...
 
You are referencing "the extreme displacement condition and the
original (as­installed) condition" and I am talking about "any anticipated
condition with a greater differential effect".
   
Again, in my example T1 is above ambient and T2 is below ambient.
_________________________
Dave Diehl  
 

 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: Load case for min. ambiant Temperature? [Re: Dave #34715 ­ 05/01/10 06:53 AM
Diehl]

Chakot   
Member    Thank you Dave.
     
 
Registered:
05/01/09   
Posts: 60   Edited by Chakot (05/01/10 06:56 AM) 
Loc: Italy  
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: Load case for min. ambiant Temperature? [Re: #34724 ­ 05/03/10 06:03 AM
Chakot]
Shahram78 
  Thanks Dave! it's very helpful.
 
Member   
   
Registered:
10/01/09 
Posts: 10  
Loc: AU
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: Load case for min. ambiant Temperature? [Re: #35645 ­ 05/26/10 02:00 AM
Shahram78]
Shahram78 
  Hi Dave,
 
Member     
   

http://forums.coade.com/ubbthreads/ubbthreads.php?ubb=showflat&Number=34684&Searchpage=11&Main=7600&Words=constant&Search=true#Post34684 2/4
12/03/2019 Load case for min. ambiant Temperature? - Intergraph CADWorx & Analysis
Registered: There is a new issue in this modeling for checking the equipment nozzle
10/01/09  loads.
Posts: 10    
Loc: AU  
This is the load cases:
L1: W+T1+P1 (OPE)  
L2: W+T2+P1 (OPE) 
L3: W+P1 (SUS)  
L4: L1­L2 (EXP)  
   
The model passed the "Code Stress" for the extreme displacement
condition (L4).
   
Shall I check the loads applied to equipment nozzle for L2, which is the
the min. ambient temp. of plant (T=­36°C), or only L1 as the max.
design temp. (T1=80°C) will be enough?
   
Regards
   
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: Load case for min. ambiant Temperature? [Re: #35656 ­ 05/26/10 07:17 AM
Shahram78]
Richard Ay 
  You should check any condition which the nozzle can experience. Many
 
Member  times, by inspection, you can conclude that one particular load case is
   
the worst condition for a given nozzle. However, if you can't draw this
Registered:
12/13/99  conclusion, it is prudent to check them all.
 
Posts: 5913 
Loc: Houston, _________________________
Texas, USA Regards,  
 
Richard Ay
 
Hexagon PPM (CAS)
 

 
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Re: Load case for min. ambiant Temperature? [Re: #35695 ­ 05/26/10 11:53 PM
Richard Ay]
Shahram78 
  Thank you Richard.
 
Member     
   
Registered:
10/01/09 
Posts: 10  
Loc: AU
Top  Reply   Quote   Quick Reply   Quick Quote   Notify   Email Post

 Search Results
 
Tweet

Like Be the first of your friends to like this.

 
Quick Reply:
HTML is
enabled
UBBCode  
is
enabled 
 Add  
Signature

http://forums.coade.com/ubbthreads/ubbthreads.php?ubb=showflat&Number=34684&Searchpage=11&Main=7600&Words=constant&Search=true#Post34684 3/4
12/03/2019 Load case for min. ambiant Temperature? - Intergraph CADWorx & Analysis

 
Submit   Preview Reply   Switch to Full Reply Screen
 
Moderator:  Dave Diehl, Richard Ay  Hop to:     CAESAR II   Go
Privacy statement · Board Rules · Mark all read
GooG_v2_copy_copy_copy Contact Us · Home Page · Top

 
Generated in 0.168 seconds in which 0.131 seconds were spent on a total of 13 queries. Zlib compression disabled.
Powered by UBB.threads™ 7.5.7  

http://forums.coade.com/ubbthreads/ubbthreads.php?ubb=showflat&Number=34684&Searchpage=11&Main=7600&Words=constant&Search=true#Post34684 4/4

You might also like