PUMP WATER HP VERSUS DISCHARGE PRESSURE

EDWARDS MODEL 80-424 HEAVY DUTY


12.00

1800 RPM
10.00 1500 RPM
1200 RPM
1000 RPM
8.00
HORSEPOWER

6.00

4.00

2.00

0.00
5 50 100 150 200 250 300
DISCHARGE PRESSURE (PSI)

PUMP WATER FLOW VERSUS DISCHARGE PRESSURE


EDWARDS MODEL 80-424 HEAVY DUTY

50

45 1800 RPM
1500 RPM
40 1200 RPM
1000 RPM
DISCHARGE FLOW (GPM)

35

30

25

20

15

10

0
5 50 100 150 200 250 300
DISCHARGE PRESSURE (PSI)
PUMP WATER HP VERSUS DISCHARGE PRESSURE
EDWARDS MODEL 80-424 STANDARD DUTY

9.00

8.00
1800 RPM
1500 RPM
7.00
1200 RPM
1000 RPM
6.00
HORSEPOWER

5.00

4.00

3.00

2.00

1.00

0.00
5 50 100 150 200
DISCHARGE PRESSURE (PSI)

PUMP WATER FLOW VERSUS DISCHARGE PRESSURE


EDWARDS MODEL 80-424 STANDARD DUTY

50

45

40
DISCHARGE FLOW (GPM)

35

30

25

20

15
1800 RPM
10 1500 RPM
1200 RPM
5
1000 RPM

0
5 50 100 150 200
DISCHARGE PRESSURE (PSI)
PUMP WATER HP VERSUS DISCHARGE PRESSURE
EDWARDS MODEL 80-428 HEAVY DUTY
14.00

12.00 1800 RPM


1500 RPM
1200 RPM
10.00 1000 RPM
HORSEPOWER

8.00

6.00

4.00

2.00

0.00
5 50 100 150 200 250 300
DISCHARGE PRESSURE (PSI)

PUMP WATER FLOW VERSUS DISCHARGE PRESSURE


EDWARDS MODEL 80-428 HEAVY DUTY

60

1800 RPM
50 1500 RPM
1200 RPM
1000 RPM
DISCHARGE FLOW (GPM)

40

30

20

10

0
5 50 100 150 200 250 300
DISCHARGE PRESSURE (PSI)
PUMP WATER HP VERSUS DISCHARGE PRESSURE
EDWARDS MODEL 80-428 STANDARD DUTY

9.00

8.00 1800 RPM


1500 RPM
7.00 1200 RPM
1000 RPM
6.00
HORSEPOWER

5.00

4.00

3.00

2.00

1.00

0.00
5 50 100 150 200
DISCHARGE PRESSURE (PSI)

PUMP WATER FLOW VERSUS DISCHARGE PRESSURE


EDWARDS MODEL 80-428 STANDARD DUTY

60

50
DISCHARGE FLOW (GPM)

40

30

20
1800 RPM
1500 RPM
1200 RPM
10
1000 RPM

0
5 50 100 150 200
DISCHARGE PRESSURE (PSI)
PUMP WATER HP VERSUS DISCHARGE PRESSURE
EDWARDS MODEL 80-432 HEAVY DUTY
16.00

14.00 1800 RPM


1500 RPM
1200 RPM
12.00
1000 RPM

10.00
HORSEPOWER

8.00

6.00

4.00

2.00

0.00
5 50 100 150 200 250 300
DISCHARGE PRESSURE (PSI)

PUMP WATER FLOW VERSUS DISCHARGE PRESSURE


EDWARDS MODEL 80-432 HEAVY DUTY

70

60

50
DISCHARGE FLOW (GPM)

40

30

20
1800 RPM
1500 RPM
10 1200 RPM
1000 RPM

0
5 50 100 150 200 250 300
DISCHARGE PRESSURE (PSI)
PUMP WATER HP VERSUS DISCHARGE PRESSURE
EDWARDS MODEL 80-432 STANDARD DUTY

12.00

1800 RPM
10.00
1500 RPM
1200 RPM
1000 RPM
8.00
HORSEPOWER

6.00

4.00

2.00

0.00
5 50 100 150 200
DISCHARGE PRESSURE (PSI)

PUMP WATER FLOW VERSUS DISCHARGE PRESSURE


EDWARDS MODEL 80-432 STANDARD DUTY

70

60

50
DISCHARGE FLOW (GPM)

40

30

20
1800 RPM
1500 RPM
10 1200 RPM
1000 RPM

0
5 50 100 150 200
DISCHARGE PRESSURE (PSI)
PUMP WATER HP VERSUS DISCHARGE PRESSURE
EDWARDS MODEL 80-440 HEAVY DUTY

20.00

18.00
1800 RPM
16.00 1500 RPM
1200 RPM
14.00 1000 RPM
HORSEPOWER

12.00

10.00

8.00

6.00

4.00

2.00

0.00
5 50 100 150 200 250 300
DISCHARGE PRESSURE (PSI)

PUMP WATER FLOW VERSUS DISCHARGE PRESSURE


EDWARDS MODEL 80-440 HEAVY DUTY

90

80

70
DISCHARGE FLOW (GPM)

60

50

40

30
1800 RPM
20 1500 RPM
1200 RPM
10 1000 RPM

0
5 50 100 150 200 250 300
DISCHARGE PRESSURE (PSI)
PUMP WATER HP VERSUS DISCHARGE PRESSURE
EDWARDS MODEL 80-440 STANDARD DUTY

16.00

14.00 1800 RPM


1500 RPM
1200 RPM
12.00
1000 RPM

10.00
HORSEPOWER

8.00

6.00

4.00

2.00

0.00
5 50 100 150 200
DISCHARGE PRESSURE (PSI)

PUMP WATER FLOW VERSUS DISCHARGE PRESSURE


EDWARDS MODEL 80-440 STANDARD DUTY

90

80

70
DISCHARGE FLOW (GPM)

60

50

40

30

20 1800 RPM
1500 RPM
10 1200 RPM
1000 RPM
0
5 50 100 150 200
DISCHARGE PRESSURE (PSI)

You might also like