Professional Documents
Culture Documents
UL Standard 1700°C Large Hydrogen Atmosphere Box Furnace, 20x20x20 - (125 L) - KSL-1700X-H4
UL Standard 1700°C Large Hydrogen Atmosphere Box Furnace, 20x20x20 - (125 L) - KSL-1700X-H4
Search:
Home Page
What‘s new in crystal
What's new in equipment
Find Equipment by Application
Customized 1600C Large Hydrogen Atmosphere Box Furnace up to 20"x20"x20" (125 L) - KSL-1700X-H4
----------------------------------
--- Battery R&D Equipment --- Sale Price: RFQ
Coin Cell Preparation If you are international, please click this.
Cylindrical Cell Preparation Build when order
Pouch Cell Preparation Item Number: KSL1700XH4
Battery Test Equipment Transported by LTL Freight (Truck)
Consumables for Battery R&D
Solar & Fuel Cells R&D
Thermoelectric Materials Personalization
------- Crystal & Material -------
Crystal Substrates: A-Z Eurotherm 3500 Dual-Thermocouple Temp Programmer + Eurotherm 3200
Ceramic Substrate: A-Z Pressure Monitor and Controller + 15" Laptop + Accessories Kit (+
USD$2,695.00)
Thin Film on Substrate: A-Z
Chemical & Nano & 3D
Powders
Metallic substrate :A to Z Email this page to a friend
Target / Evaporation : A-Z
----- Sample Preparation ------
Cutting / Dicing Saws
Polishing Machines
Lab Press & Rollers
Powder & Slurry Mill / Mixer
Film Coating KSL-1700X-H4 is customizedn large box furnace designed for material synthesis under hydrogen or inert gas atmosphere up to 1600 ºC wit
Desktop Machine-shop chamber dimension of 20"x 20"x20", max. . The furnace consists of high-quality alumina fiber bricks and three sides heating bu Mo alloy co
----- Thermal Processing ------ with a vacuum-sealed steel case with water cooling jacket and automatic H2 burning system. It is an ideal tool for preparing new material
Muffle Furnaces (400-1900°C)
Tube Furnaces (1- 7 Zones) which require reduced atmosphere, such as phosphorous and Ti alloy and also heat treating materials under inert gas.
CVD Furnace System
Hi-Pressure & H2 Furnace SPECIFICATIONS
RTP Furnaces
Crystal Growth System Double layer stainless steel structure for maximum vacuum and safety, which can ensure a positive
Dry Ovens / Hot Plates
Melting and Casting Furnace Structure pressure up to 0.06MP and vacuum up to -0.1Mpa
Furnace Accessories Water cooling front door and air cooling shell
-------- Material Analysis -------- Built in pressure gauge, vacuum valves, and two gas float meters
Thermogravimetric Analysis
Battery / Capacitor Analyzers Built in H2 burning control system --- if the controller detects no flame in burner, gas delivery valve
Desk-Top X-Ray Instruments will be shut down automatically
Digital Microscopes
----- Other Lab Equipment -----
Glove Box & Fume Hood
Digital Lab Balances
Plasma/UV-Zone Cleaners
Ultrasonics/Water Circulator
UV Equipment & Adhesives Inside Chamber Size Heated chamber: 500x 500x 500 mm ( 20x20x20 inch), 125 Liter ( Max. )
Lab Ware / Accessory Energy saving 1800 grade fibrous alumina insulation
------- Sample Handling --------
Gel Sticky Boxes High purity Al2O3 coating
Membrane Film Boxes Three sides heating ( Left, right and back ) to ensure the best temperature uniformity.
Round Wafer Carriers
IC Tray & Plastic Boxes Power 30 KW
Vacuum Pen&Tweezers
PID automatic control via SCR (Silicon Controlled Rectifier) power control with phase angle fired, current
limiting resistor.
30 programmable segments for precise control of heating rate, cooling rate and dwell time.
Temperature Control Please click here to learn why SCR is more accurate than SSC (Solid state relay).
Built in PID Auto-Tune function with overheating & broken thermocouple broken protection.
Over temperature protection and alarm allows for operation without attendant(s).
+/- 1 ºC temperature accuracy.
RS485 Communications Port.
Advanced Temperature Control (Optional)
MTS02-Y Temperature control software kit (for YD518P series controllers) + 15" laptop
package is available at the options bar. Click for the detail information about the MTS02-Y software kit.
You may upgrade the temperature controller to the Eurotherm 3504 Temperature Controller which is
fully compatible with LabVIEW. This package includes a Eurotherm 3504 programmer, a
communication cable (RS485 - USB) and a software CD. Click the pic below to view the full
spec of Eurotherm 3504 temperature controller.
Water Cooling
A 16L/min recirculating water chiller is installed bottom furnace for cooling furnace sealing flange. ( CE
certified only )
Warranty One year limited warranty with lifetime support. (Consumable parts such as sample plates and
heating elements are not covered by the warranty, please order the replacement at related
products below.)
ATTENTION: Any damages caused by the use of corrosive and acidic gases are not under
the coverage of MTI One Year Limited Warranty.
Attention: A free course of safety operation training at MTI field is required to purchase this furnace. A
customer's side training is also available upon request at extra cost. If the users believe that they have
sufficient experience and knowledge to handle the furnace in the dangerous or emergent situation,
a liability release agreement must be signed at the purchase. MTI Corp. is not responsible for any
damages caused by misuse without the safety operation training. Any damages caused by the corrosive
and acidic gases are not under the coverage of the MTI One Year Limited Warranty.
CE Certified
All electric components ( >24V) are UL / MET / CSA certified
Compliance
The furnace is ready to pass TUV(UL61010) or CSA certification at extra cost. ( please click
mark below to learn details )
Please EXERCISE EXTREME CAUTION. H2 gas is highly flammable and explosive. H2 ignites at
a temperature of 400°C, an explosion could occur when the hydrogen content reaches 4.0%-74.
2% in the air, please strictly follow the rules below to for safety operation.
Inert gas MUST be used to purge the furnace chamber to eliminate all the air before introducing
the H2 gas.
The pressure inside the chamber should ALWAYS be controlled at 0.01-0.02 Mpa above the
standard atmospheric pressure during the entire heating process, otherwise, the oxygen in the air
may backflow into the furnace chamber and cause explosion in the worst case scenario.
Application Notes Pressure over 0.02Mpa or below -0.05Mpa (Relative Pressure) is strictly prohibited.
ALWAYS place the furnace in a room with the fume hood and a hydrogen detector installed.
Good ventilation is necessary for the room in which place the furnace
Exhausting Hydrogen gas in the room is forbidden.
Must be used under inert gas or hydrogen gas environment
For preserving the longevity of the furnace components, we recommend the heating rate not to
exceed 10 °C /min.
Small cracks may appear on the surface of the refractory ceramics over extended use. This is a
normal occurrence and the cracks may be repaired with alumina coating.
Please click here to learn how to DIY gas purging system.
The refractory block must be inserted before closing door.
Please Click Underline to learn "Max. Working Temperature of Heating Elements of Tungsten, Tantalum, Molybdenum Under
Various Processing Gases".
Attention: A two-stage pressure regulator must be installed on gas cylinder to limit the
pressure to below 3 PSI for safe operation. Click here to learn the installation of a gas regulator.
Related Products
Gas Mixing Control Station with Three Channel Float Flowmeters 1100C 7.6 Liter Vacuum Chamber Furnace with feedthrough flange 6" - 8.5" Quartz Tube Furnace with Water Cooling Flanges (1100C
and Valves - EQ-GSL-3F-SS - VBF-1200X-H8 , 24" heating zone) - GSL-1100X-6/8.5
Sale Price: RFQ Sale Price: RFQ Sale Price: RFQ
1200C Hydrogen Atmosphere Box Furnace with 5 heated sides Honeywell UL Approved Sensepoint Gas Detector, EQ-XCD-H2- Alumina Crucible: High Purity 100 dia. x 80 H mm (530 ml )
and 16"x16"x16" (64 L) Chamber - KSL-1200X-H2 LD Cylindrical with Covering Lid - EQ-CA-D100H80
Sale Price: RFQ Sale Price: RFQ Sale Price: USD$95.50
Copyright © 1994-2013 MTI Corporation Browse All Products