Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

NCR2752 ANTONIOBLDG 

BILLBOARD 270KPH_B 

TOWER RETROFITTING SCHEME 
(BILLBOARD‐1) 

Figure 1: Overview of retrofitting works 

PACIFICTECH SOLUTION 
NCR2752 ANTONIOBLDG 
BILLBOARD 270KPH_B 

PROVIDE 2 - L75X75X5MM DOUBLE ANGLE BARS ON LEG TO MAKE


A 4 - L75X75X5MM . USE WELD CONNECTION.

Figure 2: Tower Leg retrofitting (front and back) 

PROVIDE L75X75X5MM BACK ANGLE BARS ON DIAGONAL.


USE WELD CONNECTION.

Figure 3: Tower diagonal retrofitting (front, back and side) 

PACIFICTECH SOLUTION 
NCR2752 ANTONIOBLDG 
BILLBOARD 270KPH_B 

PROVIDE L65X65X5MM BACK ANGLE BARS ON DIAGONAL.


USE WELD CONNECTION.

Figure 4: Tower diagonal retrofitting (front, back and side) 

PROVIDE L50X50X5MM BACK ANGLE BARS ON DIAGONAL.


USE WELD CONNECTION.

Figure 5: Tower diagonal retrofitting (front, back and side) 

PACIFICTECH SOLUTION 
NCR2752 ANTONIOBLDG 
BILLBOARD 270KPH_B 

PROVIDE NEW L50X50X5MM PLAN BRACE. USE WELD


CONNECTION.

Figure 6: Tower plan brace retrofitting 

PROVIDE ADDITIONAL L50X50X5MM DIAGONAL


BRACING. USE WELD CONNECTION.

Figure 7: Tower diagonal retrofitting 

PACIFICTECH SOLUTION 