This document contains all National annex values, which are used in SDF - Basic package
Fundamental values of the basic wind velocity, vb,0, shall be determined from the wind zone according to the attached table
Table NA.A.1 - Wind zone map
Zone vb,0 qb,0
Note 1: The values of basic wind pressure qb,0 are only informational. More precise value is calculated in the form.
https://designforms.net/WebUser/Pub/Resources/Load/Wind/DIN.htm 1/4
5/14/2020 DIN National annex for EC 1991-1-4:2010-12
Clause 4.2 Basic values, paragraph (2)P, NOTE 2
Recommended value of the directional factor cdir = 1,0 for all wind directions.
Calculations from Standard are not used. All wind parameters are given in dependancy on height of the construction and terrain category. They are in the tables NA.B.2. and NA.B.4
Table NA.B.2 - Profiles of the mean wind speed, turbulence intensity, the peak wind pressure and the gust wind velocity for four terrain categories
Terrain category I II III IV
Minimal height zmin 2m 4m 8m 16 m
Mean wind velocity vm for z > zmin 1,18 • vb • (z / 10)0,12 1,10 • vb • (z / 10)0,16 0,77 • vb • (z / 10)0,22 0,56 • vb • (z / 10)0,30
Mean wind velocity vm for z ≤ zmin 0,97 • vb 0,86 • vb 0,73 • vb 0,64 • vb
Turbulence intensity Iv for z > zmin 0,14 • (z / 10)-0,12 0,19 • (z / 10)-0,16 0,28 • (z / 10)-0,22 0,43 • (z / 10)-0,30
Turbulence intensity Iv for z ≤ zmin 0,17 0,22 0,29 0,37
Peak wind pressure qp for z > zmin 2,6 • qb • (z / 10)0,19 2,1 • qb • (z / 10)0,24 1,6 • qb • (z / 10)0,31 1,1 • qb • (z / 10)0,40
Peak wind pressure qp for z ≤ zmin 1,9 • qp 1,7 • qp 1,5 • qp 1,3 • qp
Gust wind velocity vp for z > zmin 1,61 • vb • (z / 10)0,095 1,45 • vb • (z / 10)0,120 1,27 • vb • (z / 10)0,155 1,05 • vb • (z / 10)0,200
Gust wind velocity vp for z ≤ zmin 1,38 • vp 1,30 • vp 1,23 • vp 1,15 • vp
Table NA.B.4 - Profiles of the mean wind speed, turbulence intensity, the peak wind pressure and the gust wind velocity for mixed profiles
Coastline up to 5 km, North sea islands
Terrain category Inland
Baltic islands (Same as Category I)
Minimal height zmin 7m 4m
Mean wind velocity vm for 50 < z ≤ 300 1,00 • vb • (z / 10)0,16 1,18 • vb • (z / 10)0,12
Mean wind velocity vm for zmin < z ≤ 50 0,86 • vb • (z / 10)0,25 1,10 • vb • (z / 10)0,165
Mean wind velocity vm for z ≤ zmin 0,79 • vb 0,95 • vb
Turbulence intensity Iv for 50 < z ≤ 300 0,19 • (z / 10)-0,16 0,14 • (z / 10)-0,12
Turbulence intensity Iv for zmin < z ≤ 50 0,22 • (z / 10)-0,25 0,15 • (z / 10)-0,165
Turbulence intensity Iv for z ≤ zmin 0,24 0,17
Peak wind pressure qp for 50 < z ≤ 300 2,1 • qp • (z / 10)0,24 2,6 • qp • (z / 10)0,19
Peak wind pressure qp for zmin < z ≤ 50 1,7 • qp • (z / 10)0,37 2,3 • qp • (z / 10)0,27
Peak wind pressure qp for z ≤ zmin 1,5 • qp 1,8 • qp
Gust wind velocity vp for 50 < z ≤ 300 1,45 • vb • (z / 10)0,120 1,61 • vb • (z / 10)0,095
Gust wind velocity vp for zmin < z ≤ 50 1,31 • vb • (z / 10)0,185 1,51 • vb • (z / 10)0,135
Gust wind velocity vp for z ≤ zmin 1,23 • vb 1,33 • vb
https://designforms.net/WebUser/Pub/Resources/Load/Wind/DIN.htm 2/4
5/14/2020 DIN National annex for EC 1991-1-4:2010-12
Procedure from Standard is not used. Next formula is used:
where:
α is profile exponent for the profile of the mean wind speed in Table NA.B.1
z0 is the roughness length according to Table NA.B.1
z is the height above ground in meters
No national regulations.
https://designforms.net/WebUser/Pub/Resources/Load/Wind/DIN.htm 3/4
5/14/2020 DIN National annex for EC 1991-1-4:2010-12
The recommended procedure given in Standard shall be used.
Clause 7.2.2 Vertical walls of rectangular plan buildings, paragraph (2), NOTE 2
Different table is used
Table NA.1 - External pressure coefficients for vertical walls of rectangular buildings
Zone A B C D E
h/d cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1 cpe,10 cpe,1
≥5 -1,4 -1,7 -0,8 -1,1 -0,5 -0,7 +0,8 +1,0 -0,5 -0,7
1 -1,2 -1,4 -0,8 -1,1 -0,5 +0,8 +1,0 -0,5
≤ 0,25 -1,2 -1,4 -0,8 -1,1 -0,5 +0,7 +1,0 -0,3 -0,5
Clause 7.4.1 Pressure coefficients for free-standing walls and parapets, paragraph (1)
The recommended value of the horizontal eccentricity e given in Standard should be used.
https://designforms.net/WebUser/Pub/Resources/Load/Wind/DIN.htm 4/4