Quick Reference Guide: Agilent 500-MS LC/MS Supplies

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Agilent 500-MS LC/MS Supplies

Quick reference guide

Agilent supplies for Agilent


instruments
Agilent Technologies is committed to optimizing your
laboratory’s productivity, so we have produced this list of the
most commonly ordered supplies and parts for the 500-MS
LC/MS. Keep your own spares on site to minimize instrument
downtime.

HS-562 Part No. API source Part No.
GP 45 oil 8829953800 ESI needle with bonded PEEK tubing 393754401

Oil return kit 2741001500 APCI bonded needle tubing 393754403

Exhaust filter assembly 2710100100 Front shield 393733701

Exhaust filter cartridge replacement 2710100300 APCI corona needle 393734401

LC and other connections Part No. Test solutions Part No.


PEEK tubing, 1/16 in od x 0.0025 id, 10 ft 2840806400 500-MS tuning solution 393210201

PEEK tubing, 1/16 in od x 0.005 id, 10 ft, red AL35720 500-MS tuning solution TurboDDS, extended range 393211901

Copper tubing, 1/8 in od, 96 in 3700082031 Reserpine LC/MS sensitivity test solution (positive) 393727901

1001 TLL 1.0 mL syringe HM81320 4-Nitrophenol LC/MS sensitivity test solution 393728301
(negative)
KF722 Kel-F hub needle (22/2 in/3), 6/pk HM90134

Hi-Pres nut/ferrule, PEEK, 10/32, 10/pk UCF300X

PEEK tubing cutter UCA327

RheFlex one-piece fingertight, PEEK, 10/pk RE6000282RD Foreline pump supplies Part No.
Female to female Luer, 10-32, PEEK UCP659 Quiet Cover MS for Agilent LC/MS systems G6011A
Gas purification Part No. Agilent supplies - to help you get the
Nitrogen gas purifier for LC/MS 5188-5248 results you need
For greater confidence in your chromatography results,
optimize your whole system with quality Agilent columns,
Trap Part No. supplies, kits, and accessories. All are designed,
manufactured, and tested to rigorous Agilent specifications,
Electron multiplier 393175101 under a quality system registered to ISO 9001. Why risk
Conversion dynode 393169101 compromising your analytical results with anything less than
genuine Agilent supplies?
Quartz spacer 393053501
In particular, Agilent manufactures LC columns to suit almost
every technique for small molecule, large molecule and
synthetic polymer analysis, enabling scaling from 5 µm to
460-LC Part No. “Fast LC” sub-2 µm and superficially porous Poroshell 120.

Air needle, 62 mm, natural SH0045505

48-vial adaptor for 1.5 mL vials SH0045131

12-vial adaptor for 10 mL vials SH0045137

Valco ferrule, 10/pk SH0700004

Valco nut, 10/pk SH0700005

Sample needle with Valco connections SH0840313

Sample needle with Valco connections (bio-compatible) SH0840314


For Agilent’s complete listing of columns and supplies, visit
Piggy-back cooler SH0840602 us online at:
Wash position including screws SH0840711 www.agilent.com/chem/supplies
Syringe valve including valve bush SH0840712

Wash bottle, 250 mL, rectangular SH0840715

Buffer tubing, 1000 µL, Tefzel with Valco connections SH0840713

Plunger replacement tip 500 µL, 10/pk SH0700018

Stainless steel injector valve, including loop nuts and SH2002500


ferrules, 5000 psi

Rotor seal for 2002.500 valve SH2002501

Stator for 2002.500 valve SH2002502

Nut flangeless short, 1/8 in SH3796142

Male nut, 1/16 in blue SH3796143

Flangeless ferrule, 1/16 in SH3796082

Syringe, 500 µL SH4400500

This information is subject to change without notice.