Operating Manual: LKH Ultrapure
Operating Manual: LKH Ultrapure
Operating Manual
LKH UltraPure
IM70831-GB1 1999-09
ï Return to menu
Declaration of Conformity
Alfa Laval
Company Name
6000 Kolding
Address
+45 79 32 22 00
Phone No.
UltraPure LKH
Denomination Type Year
Alfa Laval
Company Signature
Designation
ï Return to menu
Table of contents
Safety
Unsafe practices and other important information are Warnings are emphasized by means of special signs.
emphasized in this manual.
1. Important information
Always read the manual before using the pump!
2
WARNING! : Indicates that special procedures must be
followed to avoid severe personal injury.
2. Warning signs
: General warning.
: Caustic agents.
ï Return to menu
Safety
All warnings in the manual are summarized on this Pay special attention to the instructions below so that
page. severe personal injury and/or damage to the pump
are avoided.
3. Safety precautions
Installation:
: Always read the technical data thoroughly (see
page 19). 3
: Always use a lifting crane when handling the pump.
Operation:
: Always read the technical data thoroughly (see
page 19).
Maintenance:
: Always read the technical data thoroughly (see
page 19).
Installation
The instruction manual is part of the delivery. The large pump sizes are very heavy.
Study the instructions carefully. Alfa Laval therefore recommends the use of a lifting
The standard delivery does not include the test crane when handling the pump.
certificate. This can be supplied on request.
1. Unpacking/Delivery
1 2
Remove packing
4 Always use a lifting crane when handling
materials!
the pump (see technical data).
CAUTION!
We cannot be held responsible for incorrect
unpacking.
3 4
Inspection! Caution!
Inspect the pump for visible transport damages. Avoid damaging the inlet and the outlet.
5 Caution! 6
Remove the shroud
before lifting!
Avoid damaging the connections for flushing Always remove the shroud, if fitted, before lifting
liquid, if supplied. the pump.
ï Return to menu
Installation
Study the instructions carefully and pay special The large pump sizes are very heavy.
attention to the warnings! Alfa Laval therefore recommends the use of a lifting
Always check the pump before operation. crane when handling the pump.
- See pre-use check on page 6.
2. Installation
1 2
CAUTION!
We cannot be held responsible for incorrect
installation. Ensure that there is sufficient clearance around
the pump (min. 0.5 m).
3 Outlet 4
Remember
seal rings!
Correct!
Few
Inlet bends!
Correct!
5 Risk of
damage!
Installation
Study the instructions carefully and pay special Check the direction of rotation of the impeller before
attention to the warnings! operation.
LKH UltraPure is without impeller screw as standard - See the indication label on the pump.
but can be supplied with one.
1 2
See the indication Correct!
6 label!
3 4
Correct!
Operation
Study the instructions carefully and pay special The pump is fitted with a warning label indicating
attention to the warnings! correct throttling.
1. Operation/Control
1 2
Burning
7
Always read the technical data thoroughly
(see page 19). danger!
CAUTION!
We cannot be held responsible for incorrect
operation/control.
3 4
Explosion
Do not
danger!
run dry!
Correct!
CAUTION!
Never run the pump with both the suction - The shaft seal must not run dry.
side and the pressure side blocked. - Never throttle the inlet side.
Throttling!
Control:
Reduce the capacity and the power consumption
by means of:
- Throttling the pressure side of the pump.
- Reducing the impeller diameter.
- Reducing the speed of the motor.
ï Return to menu
Operation
2. Fault finding
NOTE!
Study the maintenance instructions carefully
before replacing worn parts. - See page 10!
8
Cavitation:
- Reduce speed
Operation
The pump is designed for cleaning in place (CIP). Study the instructions carefully and pay special
CIP = Cleaning In Place. attention to the warnings!
The pump is designed for steam sterilization in NaOH = Caustic Soda.
place (SIP). HNO3 = Nitric acid.
3. Recommended cleaning
1 2
Caustic danger!
9
Burning
danger!
Always handle lye and acid with great Never touch the pump or the pipelines
care. when sterilizing.
3 4
Examples of cleaning agents: 1. Avoid excessive concentration of the
Use clean water, free from chlorides. cleaning agent
5 6
NOTE!
Always rinse! The cleaning agents must be stored/disposed of
in accordance with current rules/directives.
Maintenance
Maintain the pump carefully. Always keep spare shaft seals and rubber seals in
Study the instructions carefully and pay special stock.
attention to the warnings! See separate motor instructions.
See separate instructions for flushing set - if ordered.
1. General maintenance
1 2
10
Always read the technical data thoroughly
(see page 19).
Burning
danger!
Always disconnect the power supply when
servicing the pump.
NOTE!
All scrap must be stored/disposed of in
accordance with current rules/directives.
3 4
Atmospheric pres-
sure required!
CAUTION!
Fit the electrical connections correctly if they
have been removed from the motor during
service (see pre-use check on page 6).
Never service the pump with pump and
pipelines under pressure. Pay special attention to the warnings!
Maintenance
1. General maintenance
Planned maintenance - Regular inspection for Replace when replacing Yearly inspection is
leakage and smooth the shaft seal recommended
operation - Replace complete
- Keep a record of the bearing if worn
pump - Ensure that the
- Use the statistics for bearing is axially
planning of inspections locked (See motor
instructions)
Replace after leakage:
Complete shaft seal
Pre-use check
CAUTION!
Fit the electrical connections correctly if they
have been removed from the motor during
service.
(See pre-use check on page 6).
Pay special attention to the warnings!
1. Start and stop the motor momentarily.
2. Ensure that the pump operates smoothly.
Lubrication intervals for motors with grease nipples are shown on the information plate on the motor.
The lubrication intervals are based upon 80o C bearing temperature. The values should be halved for
every 15o C increase in the bearing temperature.
Note! Motors with grease nipples should be lubricated before operating the first time!
ï Return to menu
Maintenance
1 2
12
3 4
5 6
Counterhold with a
screwdriver!
If necessary!
Maintenance
7 8
Left hand
thread!
Double mechanical shaft seal:
1. Remove screws (41) and seal housing (40a).
2. Remove rotating seal rings (14) and drive
1. Remove the stationary seal ring (11). ring (52) from spring (13).
2. Remove the O-ring (12) from back plate (25). 3. Remove O-rings (15) from rotating seal rings (14).
9 10
11
Maintenance
1 2
14
3 4
Use the tool
supplied!
Left hand
thread!
1. Fit O-ring (12) on stationary seal ring (11)
and lubricate.
Fit the complete shaft seal on stub shaft (7). 2. Screw the stationary seal ring into back plate
(25).
NOTE! CAUTION!
Make sure that connex pin (8) on the stub shaft Only tighten by hand to avoid deforming the
enters the notch in drive ring (10). stationary seal ring (max. 7 Nm).
5 6
Maintenance
Study the instructions carefully. Lubricate the rubber seals before fitting them.
The items refer to the drawings and the parts list on
the pages 20-23.
7 8
15
Maintenance
Study the instructions carefully. Lubricate the rubber seals before fitting them.
The items refer to the drawings and the parts list on : Relates to the shaft seal.
the pages 20-23.
1 2 1
16
3 4
Maintenance
Study the instructions carefully. Lubricate the rubber seals before fitting them.
The items refer to the drawings and the parts list on : Relates to the shaft seal.
the pages 20-23.
17
9 10
10
Maintenance
Study the instructions carefully. Lubricate the rubber seals before fitting them.
The items refer to the drawings and the parts list on : Relates to the shaft seal.
the pages 20-23.
5. Adjustment of shaft
1 2
10-20 mm
18
3 4
Distance = 0.5 mm
15Nm
Technical data
It is important to observe the technical data during Inform the personnel about the technical data.
installation, operation and maintenance.
1. Technical data
Data
Max. inlet pressure ............................................ 1000 kPa (10 bar)
Temperature range ............................................. -10o C to +140o C (FPM) 19
Noise level .......................................................... 60-80 dB (A)
Materials
Product wetted steel parts ................................. AISI 316L
Other steel parts ................................................ AISI 304
Finish ................................................................. Polished
Product wetted seals ......................................... FPM (standard)
Other O-rings ..................................................... FPM
Alternative seals ................................................. EPDM and FEP
Shaft seal
Seal types .......................................................... External single, double mechanical or John Crane seal
Max. water pressure (double mechanical seal) ... Normally atmospheric (max. 5 bar)
Water consumption (double mechanical seal) .... 0.25-0.5 l/min.
Material, stationary seal ring .............................. Acid resistent steel with sealing surface of Silicon Carbide
Material, rotating seal ring .................................. Silicon Carbide
Material, O-rings ................................................ FPM (standard)
Alternative material, O-rings ............................... EPDM and FEP
Motor
Foot-flanged motor acc. to IEC metric standard
2 poles = 3000/3600 rpm. at 50/60 Hz
IP55 (drain hole with labyrinth plug), insulation class F
(
Voltage and frequency (standard) ....................... 3~, 50 Hz, 220-240VD/380-420VY
3~, 60 Hz, 250-280VD/440-480VY
£ 4 kW
£ 4.6 kW )
(
3~, 50 Hz, 380-420VD/660-690VY
3~, 60 Hz, 440-480VD
³ 5.5 kW
³ 6.3 kW )
Motor sizes (kW), 50 Hz .................................... 1.5, 2.2, 3.0, 4.0, 5.5, 7.5, 11.0, 15.0, 18.5, 22.0
Motor sizes (kW), 60 Hz .................................... 1.75, 2.5, 3.5, 4.6, 6.3, 8.6, 12.5, 17.0, 21.0, 25.0
Max. weight for LKH UltraPure-pumps ................ LKH UltraPure-10: 48 kg, LKH UltraPure-20: 65 kg,
.......................................................................... LKH UltraPure-25: 118 kg, LKH UltraPure-35: 118 kg,
.......................................................................... LKH UltraPure-40: 156 kg
Drawing/Parts list
The drawing and the parts list include all items of the The items are identical with the items in the Spare
pump. Parts List.
When ordering spare parts, please, use the Spare
Parts List.
Parts list
LKH UltraPure-10, -20, -25, -35, -40
Drawing/Parts list
This page shows an exploded drawing of LKH The drawing includes all items of the pump.
UltraPure. They are identical with the items in the Spare Parts
List.
Exploded drawing
Flow meter
21
Drawing/Parts list
The drawing and the parts list include all items of the The items are identical with the items in the Spare
pump. Parts List.
When ordering spare parts, please, use the Spare
Parts List.
Parts list
LKH UltraPure-10, -20, -25, -35, -40
Drawing/Parts list
The drawing shows LKH UltraPure. The items refer to the parts list on the opposite part of
the page.
Drawings
23
Fitting of legs
ï Return to menu