Project Summary

 Customer : SWITZ LANKA PVT LTD


 Project : Single Storey Layer House
 House
Size : 9m x 95m x 3.4m H (Wall height
600mm by others)
 Location : Sri Lanka
CONCEPTUAL
DESIGN SPECIFICATION
Code of Practise
 Design :
 BS 5950 Structural Use of Steelwork in Building
 BS
5950 Part 1 : 2000 – Code of practice for design in
simple continuous construction
 BS5950 Part 5 : 1998 – Code of practice for design of cold
formed section
 Load :
 BS 6399 : Part 1 : 1996 – for dead load
 BS 5502 : Part 22 : 1993 – for loading of any building for
agriculture
 CP3 : Chapter V : Part 2 : 1972 – for wind load
BUILDING SPECIFICATION
Structure
 Made of 100% galvanized high tensile steel with min 275g/m2 or
180g/m2 galfan bothsides for all steel members which including
column, trusses, purlin bracing and door frame.
 The structure is fully connected with bolt and nut and ruspert
coated self tap screw with no site welding.
 Main Column
 3.4m height made of 150mm x 100mm x 5.0mm hot dipped
galvanized hollow section at 6.0m interval.
 Trusses
 Built up trusses with double C-channel of C10015 for top
chord, C10020 for bottom chord, and C10010 for vertical
and diagonal section.

cont…
…cont
Structure
 Purlin
 Trusses are connected with 150mm x 66mm x 1.2mm thk
G.I C-channel at 1.3m spacing.
 Gable end fan and pad cooling area
 100mm x 50mm x 1.9mm G.I hollow section to reinforce
and enable the fan fixing.
 Wind load capacity
 150km/hour
TYPICAL STRUCTURE
INSTALLATION
Roof & Ceiling
 Roof
 Corrugated Aluzinc AZ 150 of 0.4mm thick TCT metal sheet
with minimum coating 150g/m2 at 11° pitch laid on top of
purlin.
 Roof eave
 0.6m extended from building edge.
 0.9m extended from dock house edge.

cont…
Roof & Ceiling
cont…

 Insulation
 First layer
 50mm thick fibreglass wool (density 10kg/m3) with aluminium
foil laid between metal roof sheet and purlin.
 Second layer
 50mm thick fibreglass wool (density 10kg/m3) above ceiling for
double protection from radiant heat.
 Ceiling
 Corrugated Aluzinc AZ150
0.35mm thick TCT metal sheet on
75mm x 0.8mm G.I frame laid underneath roof truss.
 Insulation R-value
K = 0.044 W/m.K
 R = 12
TYPICAL ROOF SHEET
INSTALLATION
ROOF AND CEILING
INSULATION
TYPICAL CEILING
INSTALLATION
Side & Gable End Wall
 Side wall/ gable end wall
 0.33mm thk PPGI metal cladding
 PVC coated galvanized netting (curtain by others)
 Fan
 Aluminium angle is fixed on the fan opening to enable fan
installation.
 Pad cooling
 A dog house corridor of 1.2m wide is created for cooling pad
installation.
SIDEWALL
TYPICAL DOCKHOUSE
FOR COOLING PAD
GABLE END WALL
Door

 Doors are made of 40mm thick PU panel with


aluminium capping.
 Rubber seal is fixed at door edges for air tightness.
 Door size
 Double leaves 2000mm x 2100mm H (2 sets)
 Single leaf 900mm x 2100mm H (4 sets)
 Single leaf 750mm x 2100mm H (2 sets)
 Hinges
 Heavy duty stainless steel hinges.
DOOR
DOOR ACCESSORIES
Accessories

 Bolt and nut


 Fully galvanized bolt and nut and Class 2 self-tap ruspert
screw.
 Sealing compound
 Non-shrinkable silicon sealant for gap sealing and air
tightness.
 Capping and flashing
 0.38mm thick TCT metal sheet cut and bend to shape for
all edges.
BOLT AND NUTS
TYPICAL INSTALLATION
DETAILS
END