Professional Documents
Culture Documents
Building Specifications For Switz Lanka PVT LTD
Building Specifications For Switz Lanka PVT LTD
Project Summary
cont…
…cont
Structure
Purlin
Trusses are connected with 150mm x 66mm x 1.2mm thk
G.I C-channel at 1.3m spacing.
Gable end fan and pad cooling area
100mm x 50mm x 1.9mm G.I hollow section to reinforce
and enable the fan fixing.
Wind load capacity
150km/hour
TYPICAL STRUCTURE
INSTALLATION
Roof & Ceiling
Roof
Corrugated Aluzinc AZ 150 of 0.4mm thick TCT metal sheet
with minimum coating 150g/m2 at 11° pitch laid on top of
purlin.
Roof eave
0.6m extended from building edge.
0.9m extended from dock house edge.
cont…
Roof & Ceiling
cont…
Insulation
First layer
50mm thick fibreglass wool (density 10kg/m3) with aluminium
foil laid between metal roof sheet and purlin.
Second layer
50mm thick fibreglass wool (density 10kg/m3) above ceiling for
double protection from radiant heat.
Ceiling
Corrugated Aluzinc AZ150
0.35mm thick TCT metal sheet on
75mm x 0.8mm G.I frame laid underneath roof truss.
Insulation R-value
K = 0.044 W/m.K
R = 12
TYPICAL ROOF SHEET
INSTALLATION
ROOF AND CEILING
INSULATION
TYPICAL CEILING
INSTALLATION
Side & Gable End Wall
Side wall/ gable end wall
0.33mm thk PPGI metal cladding
PVC coated galvanized netting (curtain by others)
Fan
Aluminium angle is fixed on the fan opening to enable fan
installation.
Pad cooling
A dog house corridor of 1.2m wide is created for cooling pad
installation.
SIDEWALL
TYPICAL DOCKHOUSE
FOR COOLING PAD
GABLE END WALL
Door