Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

7/5/2016 S600

Prover CSV
________________________________________________________________________________ 

                     METER PROOF REPORT                      13/05/2016 17:30:07 
________________________________________________________________________________ 

CERTIFICATION DATE        20/12/2014    PROVER COMPANY                    Brooks 
                                        PROVER UNIT SERIAL NO    8710‐14332‐11‐2 
BASE PROVER VOLUME bbl        0.7106 
________________________________________________________________________________ 

METER SERIAL NO             EB122822    MANUFACTURER                 SMITH METER 
METER ID                     FQ‐3303    METER MODEL                  PDM‐JA10‐S3 
LOCATION                BLENDING CB9 
                                        FLUID CALCS                CTL:   API54B 
METER K‐FACTOR    pls/b   1000.000000                              CPL: API1121M 
________________________________________________________________________________ 

FLOW RATE         bbl/h        0.000    TEMP & PRESS SOURCE                METER 
STANDARD DENSITY  kg/m3        0.000    DENSITY SOURCE                KPD STD DN 
________________________________________________________________________________ 

PASSES/RUN    3 

RUN NUMBER                      1          2          3          4          5 
AVERAGE DATA 
 METER PULSES     pls         687.44     688.62     687.06     687.75     687.27 
 PROVER TEMP      Deg.F       161.70     161.72     161.73     161.74     161.75 
 CTSp                       1.001236   1.001237   1.001237   1.001237   1.001237 
 CTLp                       0.953154   0.953145   0.953141   0.953133   0.953129 
 PROVER PRESSURE  psig         23.73      23.73      23.74      23.77      23.78 
 CPSp                       1.000012   1.000012   1.000012   1.000012   1.000012 
 CPLp                       1.000159   1.000159   1.000159   1.000159   1.000159 
 METER TEMP       Deg.F       161.34     161.36     161.42     161.44     161.44 
 CTLm                       0.953321   0.953313   0.953283   0.953276   0.953273 
 METER PRESSURE   psig        121.40     121.50     121.59     121.50     121.43 
 CPLm                       1.000813   1.000814   1.000815   1.000814   1.000814 
 METER K FACTOR   pls/b    966.944409 968.605781 966.384030 967.349536 966.681889 

 PROVER VOLUME    bb         0.67831    0.67830    0.67830    0.67829    0.67829 
 = BPV * CTSp * CPSp * CTLp * CPLp 
 METER VOLUME     bb         0.65589    0.65701    0.65550    0.65615    0.65569 
 = (Pls / KF) * CTLm * CPLm 
 METER FACTOR               1.034186   1.032412   1.034785   1.033752   1.034466 
 = Prover Volume / Meter Volume 
________________________________________________________________________________ 

FINAL METER FACTOR                     0.000000 
 = Avg of above meter factors 
REPEATABILITY     %                    0.099909 
 = (avg ‐ run) * 100 / avg                
   [API Method 1]    

                        ___________________________________          __________ 
                                   Signature                            Date 

http://169.254.1.1/d10ce37/fpdf.cgi 1/1