amploc

current sensors

805/964-9119 FAX 805/967-8789


AMP50 50 Ampere Rating Box 152, Goleta, CA 93116
e-mail:sales@amploc.com
Hall effect linear sensors. (-40 to +125C) www.amploc.com

Sensed +Vs
Current Vs= +5V Vs= +5V
Sensor (Amps ∆Vo at peak Sensitivity 1
Style Fig. peak) rated current * mV/A * 3
AMP50 1 50 1.14V 23 Sensor Vo
Null Offset=Vs/2
2
Linear to 90A
* proportional to Vs

Figure 1 AMP50

Magnetic Sense
.83 Circuit
.36 Circuit
+Is

.16 .51 +Vs


.36
.29 Sensed
123 Current 1 2 3
Dimensions: Inches Supply Gnd. Output
Terminals: .025 sq., 0.1 spacing.
Caution: Do not reverse supply voltage polarity.
Weight: 3 grams.

ELECTRICAL CHARACTERISTICS

Supply voltage, Vs........................ +4.5 to +10.0Vdc


Supply Current................................. 10mA max.
+ Output Current..................................... 2mA max.
Vo Offset Voltage, Vo (Sensed Current= 0A.)...Vs/2±2%
Output Voltage, Vo is proportional to Vs.
Temperature Error
Null Offset= Vs/2 Null................... ....................................... .03%/C
Gain........................................................ .03%/C
0 Temperature Range..........................-40C to + 125C
Response Time.......................................... 3µSec.
-Ip I= Sensed Current (A) +Ip
Linearity (Full Scale).......................................... 1%
Accuracy (Full Scale)........................................ ±2%
A. C. Hysterisis Error....................................... 0.5%