07 08 09 10 11 12 13 14
360°C round Cassette FCU 2-pipe 4-way cassette FCU-C series 4-pipe 4-way cassette FCU-A series 4-pipe 4-way cassette FCU-A series
FAN COIL UNIT-for water system
15 16 17 18 19 20 21 22
4-pipe 4-way cassette FCU-A series Marine Duty 4-way Cassette FCU Self-Drainage 4-way Cassette FCU 1-way Cassette FCU-Normal type
亿 莱 德
23 24 25 26 27 28 29 30
1-way cassette FCU-Slim type 2-way cassette FCU 2-pipe 6-way cassette FCU Ultra-thin, ceiling concealed FCU
31 32 33 36 37 38 39 40
Floor standing/wall mounted FCU Ceiling concealed FCU-12Pa/30Pa/30Pa High static pressure Duct type FCU Universal FCU
41 44 45 48
Floor Covector Chilled Beam
Refrigerant Indoor Unit
51 52 53 54 55 56 57 58
Floor Standing Indoor Unit 360°C round cassette indoor unit Ultra-thin concealed duct indoor unit 1-way cassette indoor unit-slim type
59 60 61 62 63 64
1-way cassette indoor unit-normal type 2-way cassette indoor unit 4-way cassette indoor unit
FAN COIL UNIT
- for hot/chilled water systerm
Page
Page0515
Cassette Fan Coil Unit
Yilaide’s cassette fan coil units are terminals of a hydronic system for ceiling installation.
They are suitable for chilled and/or hot water air conditioning system.
Nomenclature
FP-68KM4-V/C-EC
68: Air flow volume, 68x10 CMH
EC: equipped with EC motor
Default AC motor)
1: 1-way
2: 2-way Desin Series:
4: 4-way A series / B series / C series
6: 6-way ACY series: for Marine Duty
Y: Round Z series: for self-drainage units
V: 2-pipe system
P: 4-pipe system
Master-slave network control --- optional for cassette fan coil unit
The Master-slave network control system offers the possibility to control the fan coil unit together:
In this way, it can use wire wall pad or wireless remote control and PCB together to control all the FCUs. One group
can control at most 32 pcs of FCUs.
There are two methods to use the master-slave network control function, one is by remote controller, and the
other is using wire wall pad.
Page 06
360º Round Cassette FCU
Optional
Control System:
1. Wireless remote controller is standard;
2. Wired wall controller is optional;
3. Auto reset, operation mode control; with room sensor & coil
sensor;
4. daily timer or weekly timer
5.auto-diagnose, protections and error code disply; jumpers
configurations on electronic board
6. RS485 ModBus, master-slave network control-Optional
Dimensions: Unit: mm
864 864
832 832
FP-85-136 FP-170-238
416.0 416.0
250.0 290.0
114.0 114.0
Page 07
Design Features
Round Cassette with an innovative 360° airflow ensures optimal air conditioning which also eliminates dead zones. 360 degree directional
wind coming out from circular heat exchanger can deliver air evenly throughout every corner in any space.
Performance Date:
Air Flow: 500 ~ 1400cfm
Cooling Capacity: 4.5KW ~12.6KW
Model: FP-*KMY-V/A FP-85KMY-V/A FP-102KMY-V/A FP-136KMY-V/A FP-170KMY-V/A FP-204KMY-V/A FP-238KMY-V/A
CFM 500 600 800 1000 1200 1400
H m3/h 850 1020 1360 1700 2040 2380
Air Flow Rate M m3/h 640 790 1030 1290 1500 1800
L m3/h 430 520 690 860 1030 1200
H KW 4.5 5.6 7.0 9.1 10.8 12.6
Total Capacity M KW 4.2 4.3 5.7 7.9 8.6 10.0
L KW 3.0 3.6 4.5 6.0 6.8 8.0
H KW
Cooling
Sensible Capacity M KW
L KW
Water flow rate l/h 780 970 1260 1710 1920 2160
Water pressure drop kPa 16 18 19 17 19 22
H KW 7.0 8.4 11.2 13.9 16.7 19.5
Heat
Page 08
2-pipe 4-way Cassette - C series
Optional
Control System:
1. Wireless remote controller is standard;
2. Wired wall controller is optional;
3. Auto reset, operation mode control; with room sensor & coil sensor;
4. daily timer or weekly timer
5.auto-diagnose, protections and error code disply; jumpers configurations
on electronic board
6. Built-in Main PCB: with no function of RS485 ModBus;
7. Main PCB is installed outside of the unit body, then the RS485 ModBus,
master-slave network control can be supplied as Optional
Dimensions: Unit: mm
H
G
E
F
FP-34KM4-V/C FP-170KM4-V/C
FP-51KM4-V/C FP-85KM4-V/C
Dim. FP-102KM4-V/C FP-204KM4-V/C
C
B
A
FP-68KM4-V/C FP-238KM4-V/C
FP-80KM4-V/C FP-136KM4-V/C
Page 09
Design Features
Suitable for hot/chilled water system, ceiling installation;
Standard build-in main board and external control box as optional; (no MBS function in case of the build-in system)
Performance Date:
Air Flow: 200 ~ 1400cfm
Cooling Capacity: 2.0KW~12.6KW
Model: FP-*KM4-V/C FP-34KM4-V/C FP-51KM4-V/C FP-68KM4-V/C FP-80KM4-V/CFP-85KM4-V/C FP-102KM4-V/C FP-136KM4-V/C FP-170KM4-V/C FP-204KM4-V/C FP-238KM4-V/C
CFM 200 300 400 450 500 600 800 1000 1200 1400
H m3/h 340 510 680 800 850 1020 1360 1700 2040 2380
Air Flow Rate M m3/h 280 390 520 600 680 790 1030 1400 1500 1850
L m3/h 180 260 350 410 490 520 590 950 1030 1500
H KW 2.0 2.7 3.7 4.2 4.7 5.8 7.2 9.2 11.0 12.6
Total Capacity M KW 1.7 2.3 2.8 3.3 3.8 4.6 5.8 8.0 9.0 10.5
L KW 1.1 1.4 2.0 2.3 2.7 3.9 4.3 6.5 7.0 9.0
H KW 1.4 1.9 2.5 2.9 3.2 4.0 5.0 6.3 7.6 8.7
Cooling
Sensible Capacity M KW 1.2 1.6 1.9 2.2 3.1 3.2 3.9 5.5 6.0 7.1
L KW 0.8 1.0 1.4 1.7 2.4 2.5 2.8 4.3 4.6 6.1
Water flow rate l/h 345 470 640 720 808 995 1240 1580 1890 2160
Water pressure drop kPa 15 27 15 16 12 16 21 37 40 47
H KW 2.8 4.2 5.6 6.3 7.0 8.4 11.2 13.9 16.7 19.5
Heating Capacity M KW 2.5 3.5 4.2 4.9 5.7 6.9 8.7 12.0 13.5 15.7
Heat
L KW 1.7 2.1 3.0 3.5 4.0 5.8 6.4 9.7 10.5 13.5
Power supply 220~240V/1PH/50Hz(or 60HZ)
Power Input W 39 52 62 65 76 96 132 152 189 220
Sound pressure dB(A) 37 39 41 42 43 45 46 47 50 52
Type Centrifugal Fan
Fan Model Ø315 Ø315 Ø315 Ø315 Ø380 Ø380 Ø380 Ø476 Ø476 Ø476
Quantity Nr. 1 1 1 1 1 1 1 1 1 1
Type 3-speed Motor
Motor
Quantity Nr. 1 1 1 1 1 1 1 1 1 1
Coil Rows Nr. 2
Max. working pressure MPa 1.6
Coil
Tuber Diameter inch 3/8”
Unit body mm 582x582x265 712x712x290 827x827x290
Dimensions Panel assembly
mm 680x680x30 830x830x30 980x980x30
Water inlet/outlet pipe inch ZG3/4” / ZG3/4”
Connection Condensate discharge inch 26
Weight(with feet, with casing) kg 20 20 20 20 26 26 26 36 36 36
Page 10
4-pipe 4-way Cassette - C series
Optional
Control System:
1. Wireless remote controller is standard;
2. Wired wall controller is optional;
3. Auto reset, operation mode control; with room sensor & coil sensor;
4. daily timer or weekly timer
5.auto-diagnose, protections and error code disply; jumpers configurations
on electronic board
6. Built-in Main PCB: with no function of RS485 ModBus;
7. Main PCB is installed outside of the unit body, then RS485 ModBus,
master-slave network control can be supplied as Optional
Dimensions:
A
D
B
C
B
A
Unit: mm
Page 11
Design Features
Suitable for hot/chilled water system, ceiling installation;
External control box
Performance Date:
Air Flow: 400 ~ 1400cfm
Cooling Capacity: 2.7KW~8.8KW
Model: FP-*KM4-P/C FP-68KM4-P/C FP-80KM4-P/C FP-85KM4-P/C FP-102KM4-P/C FP-136KM4-P/C FP-170KM4-P/C FP-204KM4-P/C FP-238KM4-P/C
CFM 400 450 500 600 800 1000 1200 1400
H m3/h 680 800 850 1020 1360 1700 2040 2380
Air Flow Rate M m3/h 520 600 680 790 1030 1290 1500 1800
L m3/h 350 410 490 520 690 860 1030 1200
H KW 2.7 3.1 3.4 3.8 5.0 6.3 7.3 8.8
Total Capacity M KW 2.1 2.4 2.6 2.8 3.8 4.8 5.4 6.7
L KW 1.4 1.6 1.9 2.0 2.6 3.2 3.8 4.5
H KW 1.9 2.2 2.4 2.7 3.6 4.5 5.1 6.2
Cooling
Sensible Capacity M KW 1.5 1.7 1.8 2.0 2.8 3.5 3.9 4.7
L KW 1.0 1.1 1.4 1.5 1.8 2.3 2.8 3.1
Water flow rate l/h 464 504 585 650 860 1080 1255 1513
Water pressure drop kPa 11 13 18 22 24 27 30 35
H KW 3.2 3.8 4.5 5.1 5.8 7.8 8.7 10.5
Heating Capacity M KW
Heat
Page 12
2-pipe 4-way Cassette - A series
Optional
Control System:
1. Wireless remote controller is standard;
2. Wired wall controller is optional;
3. Auto reset, operation mode control; with room sensor & coil sensor;
4. daily timer or weekly timer
5.auto-diagnose, protections and error code disply; jumpers configura-
tions on electronic board
6. RS485 ModBus, master-slave network control is optional
Dimensions: Unit: mm
612
580
FP-85KM4-V/A
FP-102KM4-V/A
FP-136KM4-V/A
FP-34KM4-V/A FP-170KM4-V/A
A
B
FP-51KM4-V/A FP-204KM4-V/A
424
FP-68KM4-V/A FP-238KM4-V/A
FP-80KM4-V/A FP-289KM4-V/A
FP-85KM4-V/A FP-170KM4-V/A FP-289KM4-V/A
FP-340KM4-V/A Dim. FP-102KM4-V/A FP-204KM4-V/A FP-340KM4-V/A
FP-136KM4-V/A FP-238KM4-V/A
A 830 980 1140
B 338 416 488
C 737 864 992
D 705 832 960
290
242
250
215
195
114
Page 13
Design Features
Suitable for hot/chilled water system, ceiling installation;
Performance Date:
Air Flow: 200 ~ 2000cfm
Cooling Capacity: 2.0KW~17.6KW
Model: FP-*KM4-V/A FP-34KM4-V/A FP-51KM4-V/A FP-68KM4-V/A FP-80KM4-V/A FP-85KM4-V/A FP-102KM4-V/A FP-136KM4-V/A FP-170KM4-V/A FP-204KM4-V/A FP-238KM4-V/A FP-289KM4-V/A FP-340KM4-V/A
CFM 200 300 400 450 500 600 800 1000 1200 1400 1700 2000
H m3/h 340 510 680 800 850 1020 1360 1700 2040 2380 2890 3400
Air Flow Rate M m3/h 280 390 520 580 640 790 1030 1290 1500 1800 2100 2600
L m3/h 180 260 350 390 430 520 690 860 1030 1200 1600 1900
H KW 2.0 2.7 3.7 4.2 4.5 5.6 7.0 9.1 10.8 12.6 15.3 17.6
Total Capacity M KW 1.8 2.3 3.1 3.8 4.2 4.3 5.7 7.9 8.6 10.0 11.7 13.5
L KW 1.6 1.8 2.6 2.8 3.0 3.6 4.5 6.0 6.8 8.0 9.3 9.9
H KW 1.5 1.9 2.6 2.9 3.5 3.9 5.0 6.4 7.7 9.0 11.5 14.8
Cooling
Sensible Capacity M KW 1.3 1.7 2.0 2.6 3.2 3.3 4.3 5.9 6.5 7.5 8.4 11.1
L KW 1.2 1.4 1.8 1.9 2.8 2.9 3.6 4.8 5.4 6.4 6.4 7.8
Water flow rate l/h 345 470 640 720 780 970 1260 1710 1920 2160 2640 3027
Water pressure drop kPa 7 9 11 14 16 18 19 17 19 22 36 48
H KW 2.8 4.2 5.6 6.3 7.0 8.4 11.2 13.9 16.7 19.5 23.7 25.5
Heating Capacity M KW 2.5 3.4 4.5 5.5 6.3 6.5 8.5 12.0 12.6 15.6 17.5 18.6
Heat
L KW 2.0 2.7 4.0 4.5 5.0 5.2 6.7 9.0 10.2 12.0 13.8 13
Power supply 220~240V/1PH/50Hz(or 60HZ)
Power Input W 39 52 62 68 76 96 132 152 189 220 330 340
Sound pressure dB(A) 37 39 41 42 43 45 46 47 50 52 57 65
Type Centrifugal Fan
Fan Model Ø315 Ø315 Ø315 Ø315 Ø380 Ø380 Ø380 Ø476 Ø476 Ø476 Ø530 Ø530
Quantity Nr. 1 1 1 1 1 1 1 1 1 1 1 1
Type 3-speed Motor
Motor
Quantity Nr. 1 1 1 1 1 1 1 1 1 1 1 1
Coil Rows Nr. 2
Max. working pressure MPa 1.6
Coil
Tuber Diameter inch 3/8”
Unit body mm 580X580X250 705x705x290 832x832x290 960x960x290
Dimensions Panel assembly
mm 680X680X30 830x830x30 980x980x30 1140x1140x30
Water inlet/outlet pipe inch ZG3/4” / ZG3/4”
Connection Condensate discharge inch 26
Weight(with feet, with casing) kg 20 20 20 20 25 25 25 34 34 34 52 50
Page 14
4-pipe 4-way Cassette - A series
Optional
Control System:
1. Wireless remote controller is standard;
2. Wired wall controller is optional;
3. Auto reset, operation mode control; with room sensor & coil sensor;
4. daily timer or weekly timer
5.auto-diagnose, protections and error code disply; jumpers configurations on
electronic board
6. RS485 ModBus, master-slave network control is optional
Dimensions: Unit: mm
Page 15
Design Features
Suitable for hot/chilled water system, ceiling installation;
Performance Date:
Air Flow: 400~2000cfm
Cooling Capacity: 2.6KW~11.5KW
CFM 400 450 500 600 800 1000 1200 1400 1700 2000
H m3/h 680 800 850 1020 1360 1700 2040 2380 2890 3400
Air Flow Rate M m3/h 520 580 640 790 1030 1290 1500 1800 2100 2600
L m3/h 350 390 430 520 690 860 1030 1200 1600 1900
H KW 2.6 2.8 3.1 3.6 4.8 6.0 7.0 8.4 10.3 11.5
Total Capacity M KW 2.0 2.2 2.4 2.8 3.7 4.7 6.0 6.5 7.5 8.3
L KW 1.4 1.6 1.8 2.1 3.0 3.6 4.6 5.0 5.7 6.3
H KW 1.8 2.0 2.2 2.5 3.4 4.2 4.9 5.9 8.5 9.5
Cooling
Sensible Capacity M KW 1.5 1.6 1.8 2.1 2.8 3.5 4.5 4.9 6.2 6.9
L KW 1.1 1.2 1.4 1.7 2.4 2.9 3.7 4.0 4.7 5.2
Water flow rate l/h 450 468 540 625 830 1050 1400 1500 1800 2000
Water pressure drop kPa 11 13 17 22 24 27 30 35 40 52
H KW 2.6 3.1 3.5 4.3 4.9 6.5 7.2 8.7 11.9 15.2
Heating Capacity M KW 2.0 2.3 2.7 3.2 4.3 5.4 5.6 7.6 8.7 11.3
Heat
L KW 1.4 1.7 2.1 2.5 3.5 4.2 4.3 5.8 6.6 8.7
Power supply 220~240V/1PH/50Hz(or 60HZ)
Power Input W 62 68 76 96 132 152 189 220 330 340
Sound pressure dB(A) 41 42 43 45 46 47 50 52 57 65
Type Centrifugal Fan
Fan Model Ø315 Ø315 Ø380 Ø380 Ø380 Ø476 Ø476 Ø476 Ø530 Ø530
Quantity Nr. 1 1 1 1 1 1 1 1 1 1
Type 3-speed Motor
Motor
Quantity Nr. 1 1 1 1 1 1 1 1 1 1
Coil Rows Nr. 2
Max. working pressure MPa 1.6
Coil
Tuber Diameter inch 3/8”
Unit body mm 580x580x250 705x705x290 832x832x290 980x980x290
Dimensions Panel assembly
mm 680x680x30 830x830x30 980x980x30 1140x1140x30
Water inlet/outlet pipe inch ZG3/4” / ZG3/4”
Connection Condensate discharge
inch 26
Weight(with feet, with casing) kg 21 21 26 26 26 35 35 35 53 53
Page 16
Marine Duty 4-way Cassette FCU
Optional
Control System:
Dimensions: Unit: mm
A view
A view
FP-85KM4-V/ACY FP-170KM4-V/ACY
Dim. FP-102KM4-V/ACY FP-204KM4-V/ACY
FP-136KM4-V/ACY FP-238KM4-V/ACY
A 830 980
B 338 416
C 737 861
D 705 832
E 75 65
(mm)
Page 17
Design Features
Ceiling mounted and suitable for chilled/hot water systems.
Two drain pump design, no spills when the vessel is 22 degree tilted.
Performance Date:
Air Flow: 500 ~ 1400cfm
Cooling Capacity: 4.5KW~12.6KW
Page 18
Self-Drainage 4-way Cassette
Optional
Dimensions: Unit: mm
80
E
397
70
202
118
284
202
F
242
126
617 D
585
C
FP-34KM-V/Z FP-85KM-V/Z
FP-51KM4-V/Z
424
FP-102KM4-V/Z
FP-68KM4-V/Z FP-136KM4-V/Z
FP-170KM4-V/Z
A
FP-204KM4-V/Z
FP-238KM4-V/Z
FP-289KM4-V/Z
680
FP-85KM4-V/Z FP-170KM4-V/Z
尺寸 FP-102KM4-V/Z FP-204KM4-V/Z FP-289KM4-V/Z
FP-136KM4-V/Z FP-238KM4-V/Z
Page 19
Design Features
Free drain pump, Self drainage, for hot/chilled water system and ceiling installation
1.5 1.9 2.6 3.5 3.9 5.0 6.4 7.7 9.0 11.5
Sensible Capacity M KW 1.3 1.7 2.0 3.2 3.3 4.3 5.9 6.5 7.5 8.4
L KW 1.2 1.4 1.8 2.8 2.9 3.6 4.8 5.4 6.4 6.4
Water flow rate l/h 345 470 640 780 970 1260 1710 1920 2160 2640
Water pressure drop kPa 7 9 11 16 18 19 17 19 22 36
H KW 2.8 4.2 5.6 7.0 8.4 11.2 13.9 16.7 19.5 23.7
Heat
Heating Capacity M KW 2.5 .3.4 4.5 6.3 6.5 8.5 12.0 12.6 15.6 17.5
L KW 2.0 2.7 4.0 5.0 5.2 6.7 9.0 10.2 12.0 13.8
Power supply 220~240V/1PH/50Hz(or 60HZ)
Power Input W 39 54 58 71 84 127 170 175 234 330
Sound pressure dB(A) 37 39 41 43 45 46 47 50 52 57
Type Centrifugal Fan
Fan Model Ø315 Ø315 Ø315 Ø380 Ø380 Ø380 Ø476 Ø476 Ø530 Ø530
Quantity Nr. 1 1 1 1 1 1 1 1 1 1
Type 3-speed Motor
Motor
Quantity Nr. 1 1 1 1 1 1 1 1 1 1
Coil Rows Nr. 2
Page 20
1-way Cassette FCU-Normal type
Optional
Control System:
1. Wireless remote controller is standard;
2. Wired wall controller is optional;
3. Auto reset, operation mode control; with room sensor & coil sensor;
4. daily timer or weekly timer
5.auto-diagnose, protections and error code disply; jumpers configurations
on electronic board
6. Built-in Main PCB: with no function of RS485 ModBus;
7. Main PCB is installed outside of the unit body, then RS485 ModBus,
master-slave network control can be supplied as Optional
Dimensions: Unit: mm
Page 21
Design Features
1-way casstte units, which is easy to be installed in the side of ceiling; and the unit which can be installed in a
limited ceiling. (the height of the cassette body is only 235mm)
Performance Date:
Air Flow: 200 ~ 600cfm
Cooling Capacity: 1.9KW ~ 5.4KW
Model: FP-*KM1-V/A FP-34KM1-V/A FP-51KM1-V/A FP-68KM1-V/A FP-80KM1-V/A FP-85KM1-V/A FP-102KM1-V/A
CFM 200 300 400 450 500 600
H m3/h 340 510 680 800 850 1020
Air Flow Rate M m3/h 270 400 520 650 640 750
L m3/h 190 300 400 500 490 600
H KW 1.9 2.7 3.6 4.0 4.5 5.4
Total Capacity M KW 1.5 2.2 2.8 3.3 3.4 4.0
L KW 1.0 1.6 2.2 2.6 2.6 3.2
H KW 1.3 1.9 2.5 2.8 3.2 3.8
Cooling
Page 22
1-way Cassette FCU-Slim type
Optional
Control System:
Dimensions: Unit: mm
A view
A view
Page 23
Design Features
1-way slim type casstte units, the height of the body is only 150mm, which is suitable for some very limited
space and narrow space. It’s panel and body are made by ABS, high production efficiency, exact dimension and
good consistency.
Performance Date:
Air Flow: 300 ~ 450cfm
Cooling Capacity: 3.0KW ~4.2KW
Model: FP-*KM1-V/S FP-51KM1-V/S FP-68KM1-V/S FP-80KM1-V/S
CFM 300 400 450
H m3/h 510 680 750
Air Flow Rate M m3/h 400 520 650
L m3/h 300 400 500
H KW 3.0 3.8 4.2
Total Capacity M KW 2.6 3.1 3.6
L KW 2.2 2.6 3.0
H KW
Cooling
Page 24
2-way Cassette FCU
Optional
Control System:
1. Wireless remote controller is standard;
2. Wired wall controller is optional;
3. Auto reset, operation mode control; with room sensor & coil sensor;
4. daily timer or weekly timer
5.auto-diagnose, protections and error code disply; jumpers configurations
on electronic board
6. Built-in Main PCB: with no function of RS485 ModBus;
7. Main PCB is installed outside of the unit body, then RS485 ModBus,
master-slave network control can be supplied as Optional
Dimensions:
Unit: mm
Page 25
Design Features
Unit Body Condensate Drain Pan
Made of Galvanized steel, with pre-formed expanded polystyrene In thermoforming high density expanded polystyrene, covered
air passages suitable shaped to allow passage of air, thickness with a vacuum forming polyvinyl chloride, fitted with a conden-
enough for thermal and acoustical insulation. sates draining pump and a safety float.
Performance Date:
Air Flow: 400 ~ 800cfm
Cooling Capacity: 3.6KW~7.2KW
Model: FP-*KM2-V/A FP-68KM2-V/A FP-85KM2-V/A FP-102KM2-V/A FP-136KM2-V/A
CFM 400 500 600 800
H m3/h 680 850 1020 1360
Air Flow Rate M m3/h 520 640 765 1050
L m3/h 400 490 600 800
H KW 3.6 4.5 5.4 7.2
Total Capacity M KW 2.8 3.4 4.1 5.6
L KW 2.2 2.6 3.2 4.3
H KW 2.6 3.2 3.8 5.0
Cooling
Page 26
2-pipe 6-way Cassette FCU
Optional
Control System:
1. Wireless remote controller is standard;
2. Wired wall controller is optional;
3. Auto reset, operation mode control; with room sensor & coil sensor;
4. daily timer or weekly timer
5.auto-diagnose, protections and error code disply; jumpers configurations
on electronic board
6. Built-in Main PCB: with no function of RS485 ModBus;
7. Main PCB is installed outside of the unit body, then RS485 ModBus,
master-slave network control can be supplied as Optional
Dimensions: Unit: mm
Page 27
Design Features
Unit Body Condensate Drain Pan
Made of Galvanized steel, with pre-formed expanded polystyrene In thermoforming high density expanded polystyrene, covered
air passages suitable shaped to allow passage of air, thickness with a vacuum forming polyvinyl chloride, fitted with a conden-
enough for thermal and acoustical insulation. sates draining pump and a safety float.
Performance Date:
Air Flow: 500 ~ 1000cfm
Cooling Capacity: 6.0KW~9.0KW
Page 28
Ultra-thin, ceiling concealed FCU
Optional
亿 莱 德
亿 莱 德
亿 莱 德
亿 莱 德
Control System:
1. Wireless remote controller is standard;
2. Wired wall controller is optional;
3. Auto reset, operation mode control; with room sensor & coil sensor;
4. daily timer or weekly timer
5.auto-diagnose, protections and error code disply; jumpers configurations on
electronic board
6. RS485 ModBus, master-slave network control is Optional
Design Features
Ultra-thin, ceiling concealed type FCUs, suitable for hot/chilled water system
Page 29
Performance Date:
Cooling Capacity: 1.8KW ~7.2KW
Static Pressure: 10-30Pa
Model
L
H
Cooling
Capacity M
Cooling
L
Qty.
Power Supply
Current
Sound Pressure
Net Weight
in
Drian pipe(OD)
Page 30
Floor Standing/Wall mounted FCU
Optional
Control System:
Dimensions: Unit: mm
699,2
212,07
598,83
Page 31
Design Features
Suitable for hot/chilled water system
Safety and environmental protection DC Inverter Technolgy
Use new efficient environmental protection refrigerants and clean Both indoor unit and outdoor unit use brushless DC motors for
energy to lead low-carbon life.Without destroying the ozone layer, high efficiency and energy saving. It can reach Class 1 energy
and the ozone layer destruction potential value is 0, it can reduce efficiency at the heating season, and can reduce operating
the greenhouse effect effectively. noise effectively.
H
Cooling M
Capacity
Cooling L
Sound Pressure
Control Wireless Remote Control
Unit Dimensions
Net Weight
in
Water
Connection Out
Drian pipe(OD)
Page 32
Ceiling Concealed -12Pa/30Pa/50Pa
Optional
Drain pan
Nomenclature
FP-68WA-V-PA-EC G30 D1 S L
V: 2 pipe 3 rows
P: 4 pipe 3+1 rows
Drain Pan length
Default: without plenum box S: Standard length drain pan
PB: with plenum box, bottom air inlet E: Extended length drain pan
PR: with plenum box, rear air inlet L: Length can customised as per request
Page 33
Design Features
Centrifugal Fan
Well-known brand centrifugal fans, with galvanized steel and
which is statically and dynamically balanced.
Standard:
-ESP: 12Pa, 30Pa, 50Pa
-Drain pan: Powder coating,standard length
-AC motor
-Without plenum box, without air filter
Dimensions:
464
30
30
Model FP-34WA-V FP-51WA-V FP-68WA-V FP-85WA-V FP-102WA-V FP-136WA-V FP170WA-V FP-204WA-V FP-238WA-V
A (Standard Drain Pan) 620 760 860 940 1040 1370 1470 1670 1820
A (Extended Drain Pan) 739 879 979 1059 1159 1489 1589 1789 1939
B 452 592 692 772 872 1202 1302 1502 1652
C 492 632 732 812 912 1242 1342 1542 1692
D 520 660 760 840 940 1270 1370 1570 1720
E 530 670 770 850 950 1280 1380 1580 1730
Unit: mm
Page 34
Ceiling Concealed FCU-12Pa/30Pa/50Pa
Page 35
Performance Date - 4 pipe 3+1 rows:
Air Flow: 200 ~ 1400cfm
Cooling Capacity: 1.8KW~12.0KW
Sensible Capacity 1.2 1.6 2.1 2.8 3.1 4.2 5.3 6.2 7.4
L KW 0.8 1.2 1.7 2.0 2.4 3.2 4.0 4.8 5.6
Water flow rate l/h 310 464 619 757 911 1169 1462 1754 2064
Water pressure drop kPa 11 15 21 23 32 30 35 30 40
H KW 1.7 2.4 3.3 4.1 5.1 6.2 8.0 9.7 11.2
Heating Capacity M KW 1.5 2.0 2.9 3.5 4.5 5.4 7.0 8.4 9.8
Heat
Page 36
High Static Pressure Duct type FCU
Optional
GFP-136WAV4 G110 D1 L
4 rows
Dimensions:
K
L
Model K L
504 26
504 26
504 26
624 26
624 26
798 26
798 26
798 26
Unit: mm
Page 37
Design Features
Centrifugal Fan High Efficiency Coil
Well-known brand centrifugal fans, with galvanized steel and which Coil are made of copper tubes and high exchange surface area
is statically and dynamically balanced. aluminum blue fins. All coils are 100% tested against leaks by
30bar(3Mpa) air pressure. With pipe connections and air bleed
Condensate Drain Pan vent.
Made of high quality steel plate, shape mould punched suitable for
unit drainage.
Performance Date:
Air Flow: 589 ~ 2982cfm
Cooling Capacity: 6.4KW~32.6KW
ESP: 110Pa
Model: GFP-*WAV-4 GFP-136WAV-4 GFP-170WAV-4 GFP-204WAV-4 GFP-238WAV-4 FP-289WAV-4 GFP-340WAV-4 GFP-408WAV-4 GFP-510WAV-4
CFM 589 892 1207 1415 1921 2111 2416 2982
H m3/h 1001 1516 2053 2406 3267 3590 4108 5070
Air Flow Rate M m3/h 892 1213 1643 1925 2613 2684 3286 3802
L m /h
3
669 910 1232 1444 1960 2013 2465 2851
H KW 6.4 9.1 12.6 15.1 19.8 22.2 25.6 32.6
Total Capacity M KW 5.9 7.8 10.8 12.9 17.0 18.1 21.9 26.6
L KW 4.8 6.4 8.8 10.5 13.8 14.7 17.8 21.5
H KW 4.5 6.5 8.8 10.5 13.9 15.4 17.7 22.3
Cooling
Sensible Capacity M KW 4.1 5.5 7.5 8.9 11.7 12.4 15.0 18.0
L KW 3.3 4.4 6.0 7.1 9.4 9.9 12.0 14.3
Water flow rate l/h 1116 1584 2160 2592 3420 3816 4392 5616
Water pressure drop kPa 11.2 19.2 25.1 36.2 43.2 54.8 56.1 93.4
H KW 9.7 13.7 18.8 22.6 29.7 33.3 38.3 48.9
Heating Capacity M KW 8.9 11.7 16.1 19.3 25.5 27.2 32.8 39.8
Heat
Page 38
Universal FCU
Optional
FP-68UM-V-EC C S FT L
Water pipe connection direction
68: Air flow volume L: Left pipe connection(facing the air outlet)
68x10 CMH R: Right pipe connection(facing the air outlet)
A view
2-pipe system
A view
A view
4-pipe system
Page 39
Design Features
Centrifugal Fan High Efficiency Coil
Well-known brand centrifugal fans, with galvanized steel and Coil are made of copper tubes and high exchange surface area
which is statically and dynamically balanced. aluminum blue fins. All coils are 100% tested against leaks by
30bar(3Mpa) air pressure. with 3/4”pipe connections and air bleed
Condensate Drain Pan vent.
L shaped drain pan, suitable for horizontal and/or vertical
installation.
Performance Date:
Air Flow: 200 ~ 1200cfm
Cooling Capacity: 2.0KW~10.80KW
Model: FP-*UM FP-34UM FP-51UM FP-68UM FP-85UM FP-102UM FP-136UM FP-170UM FP-204UM
CFM 200 300 400 500 600 800 1000 1200
H m3/h 380 510 680 850 1020 1360 1700 2040
Air Flow Rate M m3/h 300 420 550 680 850 1020 1360 1700
L m3/h 250 360 450 550 650 850 1100 1360
H KW 2.0 2.7 3.8 4.5 5.5 7.4 9.0 10.8
Total Capacity M KW 1.6 2.3 3.0 3.8 4.6 5.6 7.3 9.0
L KW 1.3 1.9 2.5 3.0 3.5 4.6 5.9 7.3
H KW 1.6 2.1 3.0 3.6 4.4 5.9 7.2 8.6
Cooling
Sensible Capacity M KW 1.3 1.3 2.4 3.0 3.7 4.4 5.8 7.2
L KW 1.0 1.5 2.0 2.4 2.8 3.7 4.7 5.8
Water flow rate l/h 345 460 650 770 1030 1200 1550 11850
Water pressure drop kPa 10 17 16 18 23 29 38 40
H KW 2.8 4.0 5.4 6.7 8.0 10.8 13.5 15.0
2pipe Heating Capacity M KW 2.2 3.4 4.3 5.4 7.0 8.0 11.0 13.5
L KW 1.8 2.8 3.6 4.3 5.5 7.0 8.9 11.0
H KW 1.7 2.3 3.0 3,7 4.3 5.8 7.4 8.8
Heat
4pipe Heating Capacity M KW 1.3 1.9 2.4 3.0 3.6 4.4 5.9 7.4
L KW 1.1 1.6 2.0 2.4 2.7 3.6 4.8 5.9
Water flow rate l/h 150 200 260 320 370 500 640 760
Water pressure drop kPa 4 6 10 13 17 21 30 35
Power supply 220~240V/1PH/50Hz(or 60HZ)
Power Input W 60 65 67 95 105 156 183 190
Sound pressure dB(A) 37 39 41 43 45 46 50 52
Type Centrifugal Fan
Fan Model SYP130/190J SYP130/190J SYP130/190J SYP130/190J SYP130/190J SYP130/190J SYP130/190J SYP130/190J
Quantity Nr. 1 1 2 2 3 3 4 4
Type 3-speed Motor
Motor
Quantity Nr. 1 1 1 1 2 2 2 2
Coil Rows Nr. 2-pipe system: 3rows; 4-pipe system: 3+1rows
Coil Max. working pressure MPa 1.6
Tuber Diameter inch 3/8”
Water inlet/outlet pipe inch ZG3/4” / ZG3/4“
ConnectionCondensate dischargeinch
26
Weight(with feet) 2-pipe/4-pipe kg 19/20 21/22 26/28 26/28 38/40 38/40 44/48 44/48
Weight(no feet) 2-pipe/4-pipe kg 17/18 19/20 24/26 24/26 36/38 36/38 42/46 42/46