Professional Documents
Culture Documents
Form Technical Bid Evaluation (Tbe) Propan Raya Plant 3 - Pre-Engineered Building
Form Technical Bid Evaluation (Tbe) Propan Raya Plant 3 - Pre-Engineered Building
Form Technical Bid Evaluation (Tbe) Propan Raya Plant 3 - Pre-Engineered Building
No. Description
Design Loads/Parameters/Deflection limit:
1 Live Load on Frame = 0.2 kN/m2
2 Live Load on Purlin/Roof = 0.57 kN/m2
3 Wind Load = 0.5 kN/m2
4 Seismic Load/Earthquake Zone = Based on SNI 1726:2012
5 Additional Collateral Load = 0.1 kN/m2
6 Live Load on Mezzanine at Office Area 3 kN/m2 as per SNI 1727-2013
7 Live Load on Mezzanine at Tank Area 5 kN/m2 as per SNI 1727-2013
8 Live Load on Mezzanine at Genset Area = 3 kN/m2 as per SNI 1727-2013
9 Vertical Deflection for Rafter = Span/150
10 Vertical Deflection for Purlin = Span/150
11 Lateral Deflection for Column = H/45
Dead Load for Tank at Tank Area = 5 Ton (All tank shall calculate 5 Ton and load distributed equal to All Leg Support)
12 Concrete Thickness = 120mm (Supplier Must Consider 150mm in Design Calculation)