In the approved Hydraulic particulars Distributory and off - taking sluice minor is proposed on
left/right side at K.M 0.640 to irrigate an ayacut of 110.510 Acres.
Assuming a section of 0.45m x 0.375 m with side slopes 1:1 and bed fall of 1:4000
width = 0.450 m
depth = 0.375 m
side slopes = 1:1
n = 0.025
Bed Slope = 4000
2
cross sectional area(A) = (0.45+0.45+0.375+0.375)x0.375 = 0.309 m
wetted perimeter ( P) = 0.45+ 2 x 0.375 x SQRT(1+1) = 1.511 m
Hydraulic mean depth( 'R) = A /P = 0.205 m
velocity (v) = 1/n x R 2/3 x( 1/S) 1/2
= (1/0.025x0.205^2/3x (1/4000)^1/ = 0.219 m/s
3
Discharge designed = AxV = 0.309 x 0.219 = 0.068 m /sec
3
Discharge required = 0.064 m /sec
3
Discharge designed = 0.068 m /sec
3
Discharge required = 0.064 m /sec
Section = 0.45 m x 0.375 m
velocity = 0.219 m/s
Bed fall = 1 in 4000
B) Percentage of discharge:-
3
Discharge of parent canal = 0.441 m /sec
3
Discharge of O.T Sluice = 0.068 m /sec
Percentage of discharge = 0.068 / 0.441 x 100 = 15.33%
Select the percentage of O.T.Sluice discharge to parent canal discharge is in between above 15% and parent canal
FSD is below 1.22m
Hence the height of the sill level should be fixed at 0.07 m above the bed level of the parent canal.
For Off taking sluice taking of from parent channel of discharge less than 0.71 m 3 /sec upto 0.04 m 3 /sec
However the sill level of O.T.Sluice will be fixed at 118.850 m considering minimum driving head of 0.15m.
Hence sill level of O.T.Sluice + 118.850 m rear FSL of O.T.Sluice +119.225 m
VENT WAY
+119.9 1.00 m
Q = 2.86 x A x h ^2 Where, Q = Discharge through vent 'h'
h = . minimum driving head 1.025 m
A = Area of vent way required +118.875
0.08 = 2.86 x A x 0.15 ^0.5) L
2
A = 0.072 m L= 1.00 + 2 x 3/2 x 1.025 = 4.075
Hence provide (L) = 4.1 m
Hence provide 300mm RCC hume pipes of NP2 class with aperture
Length of pipe 4.1m and thickness of pipe 25mm
Parent canal side R = 1.356 x ( q2 / ft )(1/3) Where, R = depth of scour below water tabel
q = discharge per meter width
=
f = silt factor 1.1
factor of safety = 1.50
R= 0.895 = 1.00
ON OT Sluice SIDE
Maximum scour depth = 1.5 x 1.356 x (0.15^2/1.1)^(1/3) r = 0.150
= 0.557 m
NM
AD
ER
ES
GOV
H
FORMATION OF RESERVOIR a/c KONDALAYAGEDDA
Design report of OFF TAKE SLUICE at K.M 1.190
In the approved Hydraulic particulars Distributory and off - taking sluice minor is proposed on
left/right side at K.M 1.190 to irrigate an ayacut of 342.760 Acres.
Assuming a section of 0.6m x 0.375 m with side slopes 1:1 and bed fall of 1:4000
width = 0.600 m
depth = 0.375 m
side slopes = 1:1
n = 0.025
Bed Slope = 4000
2
cross sectional area(A) = (0.6+0.6+0.375+0.375)x0.375 / 2 = 0.366 m
wetted perimeter ( P) = 0.6+ 2 x 0.375 x SQRT(1+1) = 1.661 m
Hydraulic mean depth( 'R) = A /P = 0.220 m
velocity (v) = 1/n x R 2/3 x( 1/S) 1/2
= (1/0.025x0.22^2/3x (1/4000)^1/2) = 0.229 m/s
3
Discharge designed = AxV = 0.366 x 0.229 = 0.084 m /sec
3
Discharge required = 0.149 m /sec
3
Discharge designed = 0.084 m /sec
3
Discharge required = 0.149 m /sec
Section = 0.6 m x 0.375 m
velocity = 0.229 m/s
Bed fall = 1 in 4000
B) Percentage of discharge:-
3
Discharge of parent canal = 0.441 m /sec
3
Discharge of O.T Sluice = 0.084 m /sec
Percentage of discharge = 0.084 / 0.441 x 100 = 19.02%
Select the percentage of O.T.Sluice discharge to parent canal discharge is in between above 15% and parent canal
FSD is below 1.22m
Hence the height of the sill level should be fixed at 0.07 m above the bed level of the parent canal.
For Off taking sluice taking of from parent channel of discharge less than 0.71 m 3 /sec upto 0.04 m 3 /sec
However the sill level of O.T.Sluice will be fixed at 106.650 m considering minimum driving head of 0.15m.
Hence sill level of O.T.Sluice + 106.650 m rear FSL of O.T.Sluice +107.025 m
VENT WAY
+107.63 1.00 m
Q = 2.86 x A x h ^2 Where, Q = Discharge through vent 'h'
h = . minimum driving head 1.025 m
A = Area of vent way required +106.605
0.1 = 2.86 x A x 0.15 ^0.5) L
2
A = 0.090 m L= 1.00 + 2 x 3/2 x 1.025 = 4.075
Hence provide (L) = 4.1 m
Hence provide 300mm RCC hume pipes of NP2 class with aperture
Length of pipe 4.1m and thickness of pipe 25mm
Parent canal side R = 1.356 x ( q2 / ft )(1/3) Where, R = depth of scour below water tabel
q = discharge per meter width
=
f = silt factor 1.1
factor of safety = 1.50
R= 0.895 = 1.00
ON OT Sluice SIDE
Maximum scour depth = 1.5 x 1.356 x (0.14^2/1.1)^(1/3) r = 0.140
= 0.531 m
NM
AD
ER
ES
GOV
H
FORMATION OF RESERVOIR a/c KONDALAYAGEDDA
Design report of OFF TAKE SLUICE at K.M 1.560
In the approved Hydraulic particulars Distributory and off - taking sluice minor is proposed on
left/right side at K.M 1.560 to irrigate an ayacut of 99.590 Acres.
Assuming a section of 0.45m x 0.375 m with side slopes 1:1 and bed fall of 1:4000
width = 0.450 m
depth = 0.375 m
side slopes = 1:1
n = 0.025
Bed Slope = 4000
2
cross sectional area(A) = (0.45+0.45+0.375+0.375)x0.375 /2 = 0.309 m
wetted perimeter ( P) = 0.45+ 2 x 0.375 x SQRT(1+1) = 1.511 m
Hydraulic mean depth( 'R) = A /P = 0.205 m
velocity (v) = 1/n x R 2/3 x( 1/S) 1/2
= (1/0.025x0.205^2/3x (1/4000)^1/2) = 0.219 m/s
3
Discharge designed = AxV = 0.309 x 0.219 = 0.068 m /sec
3
Discharge required = 0.066 m /sec
3
Discharge designed = 0.068 m /sec
3
Discharge required = 0.066 m /sec
Section = 0.45 m x 0.375 m
velocity = 0.219 m/s
Bed fall = 1 in 4000
B) Percentage of discharge:-
3
Discharge of parent canal = 0.276 m /sec
3
Discharge of O.T Sluice = 0.068 m /sec
Percentage of discharge = 0.068 / 0.2756 x 100 = 24.54%
Select the percentage of O.T.Sluice discharge to parent canal discharge is in between above 15% and parent canal
FSD is below 1.22m
Hence the height of the sill level should be fixed at 0.07 m above the bed level of the parent canal.
For Off taking sluice taking of from parent channel of discharge less than 0.71 m 3 /sec upto 0.04 m 3 /sec
However the sill level of O.T.Sluice will be fixed at 105.880 m considering minimum driving head of 0.15m.
Hence sill level of O.T.Sluice + 105.880 m rear FSL of O.T.Sluice +106.255m
VENT WAY
+106.76 1.00 m
Q = 2.86 x A x h ^2 Where, Q = Discharge through vent 'h'
h = . minimum driving head 1.025 m
A = Area of vent way required +105.735
0.08 = 2.86 x A x 0.15 ^0.5) L
2
A = 0.072 m L= 1.00 + 2 x 3/2 x 1.025 = 4.075
Hence provide (L) = 4.1 m
Hence provide 300mm RCC hume pipes of NP2 class with aperture
Length of pipe 4.1m and thickness of pipe 25mm
Parent canal side R = 1.356 x ( q2 / ft )(1/3) Where, R = depth of scour below water tabel
q = discharge per meter width
f = silt factor = 1.1
factor of safety = 1.50
R= 0.895 = 1.00
ON OT Sluice SIDE
Maximum scour depth = 1.5 x 1.356 x (0.15^2/1.1)^(1/3) r = 0.150
= 0.557 m
NM
AD
ER
ES
GOV
H
FORMATION OF RESERVOIR a/c KONDALAYAGEDDA
Design report of OFF TAKE SLUICE at K.M 1.800
In the approved Hydraulic particulars Distributory and off - taking sluice minor is proposed on
left/right side at K.M to irrigate an ayacut of 89.680 Acres.
Assuming a section of 0.45m x 0.35 m with side slopes 1:1 and bed fall of 1:4000
width = 0.450 m
depth = 0.350 m
side slopes = 1:1
n = 0.025
Bed Slope = 4000
2
cross sectional area(A) = (0.45+0.45+0.35+0.35)x0.35 / 2 = 0.280 m
wetted perimeter ( P) = 0.45+ 2 x 0.35 x SQRT(1+1) = 1.440 m
Hydraulic mean depth( 'R) = A /P = 0.194 m
velocity (v) = 1/n x R 2/3 x( 1/S) 1/2
= (1/0.025x0.194^2/3x (1/4000)^1/2) = 0.211 m/s
3
Discharge designed = AxV = 0.28 x 0.211 = 0.059 m /sec
3
Discharge required = 0.056 m /sec
3
Discharge designed = 0.059 m /sec
3
Discharge required = 0.056 m /sec
Section = 0.45 m x 0.35 m
velocity = 0.211 m/s
Bed fall = 1 in 4000
B) Percentage of discharge:-
3
Discharge of parent canal = 0.276 m /sec
3
Discharge of O.T Sluice = 0.059 m /sec
Percentage of discharge = 0.059 / 0.2756 x 100 = 21.45%
Select the percentage of O.T.Sluice discharge to parent canal discharge is in between above 15% and parent canal
FSD is below 1.22m
Hence the height of the sill level should be fixed at 0.07 m above the bed level of the parent canal.
For Off taking sluice taking of from parent channel of discharge less than 0.71 m 3 /sec upto 0.04 m 3 /sec
However the sill level of O.T.Sluice will be fixed at 101.680 m considering minimum driving head of 0.15m.
Hence sill level of O.T.Sluice + 101.680 m rear FSL of O.T.Sluice +102.055 m
VENT WAY
+102.56 1.00 m
Q = 2.86 x A x h ^2 Where, Q = Discharge through vent 'h'
h = . minimum driving head 1m
A = Area of vent way required +101.56
0.07 = 2.86 x A x 0.15 ^0.5) L
2
A = 0.063 m L= 1.00 + 2 x 3/2 x 1.025 = 4
Hence provide (L) = 4.1 m
Hence provide 300mm RCC hume pipes of NP2 class with aperture
Length of pipe 4.1m and thickness of pipe 25mm
Parent canal side R = 1.356 x ( q2 / ft )(1/3) Where, R = depth of scour below water tabel
q = discharge per meter width
=
f = silt factor 1.1
factor of safety = 1.50
R= 0.895 = 1.00
ON OT Sluice SIDE
Maximum scour depth = 1.5 x 1.356 x (0.131^2/1.1)^(1/3) r = 0.131
= 0.509 m
NM
AD
ER
ES
GOV
H
FORMATION OF RESERVOIR a/c KONDALAYAGEDDA
Design report of OFF TAKE SLUICE at K.M 0.020
In the approved Hydraulic particulars Distributory and off - taking sluice minor is proposed on
left/right side at K.M to irrigate an ayacut of 196.720 Acres.
Assuming a section of 0.575m x 0.455 m with side slopes 1:1 and bed fall of 1:4000
width = 0.575 m
depth = 0.455 m
side slopes = 1:1
n = 0.025
Bed Slope = 4000
2
cross sectional area(A) = (0.575+0.575+0.455+0.455)x0.455 = 0.469 m
wetted perimeter ( P) = 0.575+ 2 x 0.455 x SQRT(1+1) = 1.862 m
Hydraulic mean depth( 'R) = A /P = 0.252 m
velocity (v) = 1/n x R 2/3 x( 1/S) 1/2
= (1/0.025x0.252^2/3x (1/4000)^1/2) = 0.251 m/s
3
Discharge designed = AxV = 0.469 x 0.251 = 0.118 m /sec
3
Discharge required = 0.116 m /sec
3
Discharge designed = 0.118 m /sec
3
Discharge required = 0.116 m /sec
Section = 0.575 m x 0.455 m
velocity = 0.251 m/s
Bed fall = 1 in 4000
B) Percentage of discharge:-
3
Discharge of parent canal = 0.630 m /sec
3
Discharge of O.T Sluice = 0.118 m /sec
Percentage of discharge = 0.118 / 0.63 x 100 = 18.67%
Select the percentage of O.T.Sluice discharge to parent canal discharge is in between above 15% and parent canal
FSD is below 1.22m
Hence the height of the sill level should be fixed at 0.07 m above the bed level of the parent canal.
For Off taking sluice taking of from parent channel of discharge less than 0.71 m 3 /sec upto 0.04 m 3 /sec
However the sill level of O.T.Sluice will be fixed at 125.070 m considering minimum driving head of 0.15m.
Hence sill level of O.T.Sluice + 125.070 m rear FSL of O.T.Sluice +125.525 m
VENT WAY
+126.1 1.00 m
Q = 2.86 x A x h ^2 Where, Q = Discharge through vent 'h'
h = . minimum driving head 1.105 m
A = Area of vent way required +124.995
0.141 = 2.86 x A x 0.15 ^0.5) L
2
A = 0.127 m L= 1.00 + 2 x 3/2 x 1.025 = 4.315
Hence provide (L) = 4.1 m
Hence provide 450mm RCC hume pipes of NP2 class with aperture
Length of pipe 4.1m and thickness of pipe 25mm
Parent canal side R = 1.356 x ( q2 / ft )(1/3) Where, R = depth of scour below water tabel
q = discharge per meter width
f = silt factor= 1.1
factor of safety = 1.50
R= 0.895 = 1.00
ON OT Sluice SIDE
Maximum scour depth = 1.5 x 1.356 x (0.205^2/1.1)^(1/3) r = 0.205
= 0.684 m
NM
AD
ER
ES
GOV
H
FORMATION OF RESERVOIR a/c KONDALAYAGEDDA
Design report of OFF TAKE SLUICE at K.M 0.150 - 1L Distributory
In the approved Hydraulic particulars Distributory and off - taking sluice minor is proposed on
left/right side at K.M 0.150 to irrigate an ayacut of 149.450 Acres.
Assuming a section of 0.475m x 0.425 m with side slopes 1:1 and bed fall of 1:4000
width = 0.475 m
depth = 0.425 m
side slopes = 1:1
n = 0.025
Bed Slope = 4000
2
cross sectional area(A) = (0.475+0.475+0.425+0.425)x0.425 / 2 = 0.383 m
wetted perimeter ( P) = 0.475+ 2 x 0.425 x SQRT(1+1) = 1.677 m
Hydraulic mean depth( 'R) = A /P = 0.228 m
velocity (v) = 1/n x R 2/3 x( 1/S) 1/2
= (1/0.025x0.228^2/3x (1/4000)^1/2) = 0.235 m/s
3
Discharge designed = AxV = 0.383 x 0.235 = 0.090 m /sec
3
Discharge required = 0.087 m /sec
3
Discharge designed = 0.090 m /sec
3
Discharge required = 0.087 m /sec
Section = 0.475 m x 0.425 m
velocity = 0.235 m/s
Bed fall = 1 in 4000
B) Percentage of discharge:-
3
Discharge of parent canal = 0.177 m /sec
3
Discharge of O.T Sluice = 0.090 m /sec
Percentage of discharge = 0.09 / 0.177 x 100 = 50.77%
Select the percentage of O.T.Sluice discharge to parent canal discharge is in between above 15% and parent canal
FSD is below 1.22m
Hence the height of the sill level should be fixed at 0.07 m above the bed level of the parent canal.
For Off taking sluice taking of from parent channel of discharge less than 0.71 m 3 /sec upto 0.04 m 3 /sec
However the sill level of O.T.Sluice will be fixed at 125.160 m considering minimum driving head of 0.15m.
Hence sill level of O.T.Sluice + 125.160 m rear FSL of O.T.Sluice +125.585 m
VENT WAY
+126.04 1.00 m
Q = 2.86 x A x h ^2 Where, Q = Discharge through vent 'h'
h = . minimum driving head 1.075 m
A = Area of vent way required +124.965
0.11 = 2.86 x A x 0.15 ^0.5) L
2
A = 0.099 m L= 1.00 + 2 x 3/2 x 1.025 = 4.225
Hence provide (L) = 4.1 m
Hence provide 450mm RCC hume pipes of NP2 class with aperture
Length of pipe 4.1m and thickness of pipe 25mm
Parent canal side R = 1.356 x ( q2 / ft )(1/3) Where, R = depth of scour below water tabel
q = discharge per meter width
f = silt factor = 1.1
factor of safety = 1.50
R= 0.895 = 1.00
ON OT Sluice SIDE
Maximum scour depth = 1.5 x 1.356 x (0.189^2/1.1)^(1/3) r = 0.189
= 0.649 m
NM
AD
ER
ES
GOV
H
FORMATION OF RESERVOIR a/c KONDALAYAGEDDA