Quality Control Services Testing Lab

RCC LAB LIMITED


House # 135, Road #05,New DOHS, Mohakhali Dhaka – 1206
Mobile: +880 1922114868, Phones: +88 02 8831751
Email: info@rcclab.net, Web: www.rcclab.net

Sieve Analysis of Coarse Aggregates ASTM C136

RCC Ref no : RCC/OCT30/19 Customer Ref no :


Name of Customer: Unigears Ltd. Date of Sample received : 13.11.2019
Project: Konabari, Gazipur Condition on received:
Address: Konabari, Gazipur.

Wt. of Material (gm): 5000

Sieve Material
% Materials Cumulatative
Sieve Number Opening Retained % Finer FM
Retained % Retained
(mm) (gm)
1 inch 25.4 77 1.54 1.54 98.46
3/4 inch 19.05 1017 20.34 21.88 78.12
1/2 inch 12.5 3118 62.36 84.24 15.76
3/8 inch 9.5 638 12.76 97 3
#4 4.75 139 2.78 99.78 0.22
#8 2.36 0 0 99.78 0.22
7.1756
#16 1.19 0 0 99.78 0.22
#30 0.59 0 0 99.78 0.22
#50 0.3 0 0 99.78 0.22
#100 0.15 0 0 99.78 0.22
Pan 11 0.22 100 0
Total 5000 100

Gradation Curve
120

100
% Material Passing

80

60

40 Series1

20

0
0 5 10 15 20 25 30
Partical Size, mm

Test Performed By Head of The Department


Curve Variation With Standard
120

100
% Material Passing

80

60 Lower Limit
Upper Limit
40
Material
20

0
0 5 10 15 20 25 30
Partical Size, mm

Note: Material Curve under the stundard curve. Need to adjust upper graded aggregate.

Test Performed By Head of The Department