MXA018 EMERGENCY LIGHT SYSTEM (FOR 12V 7A BATTERY)

MXA018 Ãкºä¿©Ø¡à©Ô¹ (ãªˆä¿ 12 âÇÅ·‹ 7 áÍÁ»†)


FEATURES
- Power supply : 12VDC. 7A. (Battery)
- Max. load : 50W. at 12V. (back-up time y 90 minutes)
- There is switch TEST for test the operation.
- There is LDR sensor for detect the light, When power cut-off in daylight, the circit isn't working.
- In case at emergency light system operate : relay and load cut off when the battery has voltage less than 9V.
- Charger circuit built-in.
- PCB dimensions : 4.45x2.61 inches.

USING
CIRCUIT DIAGRAM
- VR1 used for adjust voltage at the BAT point approx. 13.8V.
- VR2 used for adjust light sensitivity.
- LED POWER indicator AC input.

INSTALLATION OF THE EMERGENCY LIGHT SYSTEM CIRCUIT


- LED CHARGER indicator battery when full battery will blank.
- LED EMER indicator emergency.
LAMP (Watts) TIME (hour)
y 1.30
SW
¤Ø³ÊÁºÑµÔ
50W
ON/OFF
y 3.20
AC IN
25W
12W y 7.00 FUSE
- 㪈¡ÑºáºµàµÍÃÕè 12 âÇÅ·ì´Õ«Õ ¡ÃÐáÊ 7 áÍÁ»ì
- ãªé¡ÑºâËÅ´ÊÙ§ÊØ´ 50 Çѵµì ·Õè 12 âÇÅ·ì (ÃÐÂÐàÇÅÒ㹡ÒÃãªé§Ò¹»ÃÐÁÒ³ 90 ¹Ò·Õ)
- ÁÕÊÇÔµ«ì TEST à¾×èÍ·´Êͺ¡Ò÷ӧҹ 1A
TRANSFORMER
- ÁÕ LDR µÃǨ¨Ñºáʧ àÁ×èÍ俴Ѻ㹵͹¡ÅÒ§Çѹ ǧ¨Ã¨ÐäÁè·Ó§Ò¹ 0 15 15VAC 1A
- ã¹¢³Ð·Õèǧ¨Ãä¿©Ø¡à©Ô¹·Ó§Ò¹ä¿ã¹áºµàµÍÃÕèµèÓ¡ÇèÒ 9 âÇÅ·ì ÃÕàÅÂì¨ÐËÂØ´·Ó§Ò¹áÅеѴ俷Õè¨èÒÂãËéâËÅ´·Ñ¹·Õ
- ÁÕǧ¨ÃªÒÃì¨áºµàµÍÃÕèã¹µÑÇ RED +
- ¢¹Ò´á¼è¹Ç§¨Ã¾ÔÁ¾ì 4.45x2.61 ¹ÔéÇ

¨Ø´µèÍãªé§Ò¹ BLACK - BATT


- VR1 äÇéÊÓËÃѺ»ÃѺáç´Ñ¹·Õè¨Ø´ BAT »ÃÐÁÒ³ 13.8 âÇÅ·ì 12V
- VR2 ÁÕäÇéÊÓËÃѺ»ÃѺ¤ÇÒÁäǢͧáʧ㹡Ò÷ӧҹ
- LED POWER ãªéáÊ´§ä¿à¢éÒ
- LED CHARGER áÊ´§¡ÒêÒÃì¨áºµàµÍÃÕè àÁ×èÍẵàµÍÃÕèàµçÁ ¨Ð´Ñº MXA018 DC LAMP
- LED EMER ¨ÐµÔ´ àÁ×èÍ俴Ѻ 12V