This competency checklist outlines the tasks required to operate an AU480 Chemistry Analyzer. It includes loading reagents, performing calibrations, running quality control samples, processing patient samples, and reviewing results. Trainees must demonstrate proficiency in these tasks, as measured by direct observation, tests, or other means. A trainer then signs off to confirm the trainee has achieved each task.
This competency checklist outlines the tasks required to operate an AU480 Chemistry Analyzer. It includes loading reagents, performing calibrations, running quality control samples, processing patient samples, and reviewing results. Trainees must demonstrate proficiency in these tasks, as measured by direct observation, tests, or other means. A trainer then signs off to confirm the trainee has achieved each task.
This competency checklist outlines the tasks required to operate an AU480 Chemistry Analyzer. It includes loading reagents, performing calibrations, running quality control samples, processing patient samples, and reviewing results. Trainees must demonstrate proficiency in these tasks, as measured by direct observation, tests, or other means. A trainer then signs off to confirm the trainee has achieved each task.
This competency checklist outlines the tasks required to operate an AU480 Chemistry Analyzer. It includes loading reagents, performing calibrations, running quality control samples, processing patient samples, and reviewing results. Trainees must demonstrate proficiency in these tasks, as measured by direct observation, tests, or other means. A trainer then signs off to confirm the trainee has achieved each task.
Achieved? Trainee Trainer Task Resources How Measured? N/A Date Y N Initial Initial Reagents Direct Observation Check reagent status Test Other __________ AU480 User’s Guide Direct Observation Load reagent bottles in the Chapter 5 Daily Startup Test refrigerators 5.5 Check Reagent Status Other __________ Direct Observation Perform a reagent check Test Other __________ AU480 User’s Guide Direct Observation Check ISE reagent status Chapter 8 Maintenance Test 8.19 ISE As Needed Other __________ Maintenance Direct Observation Load ISE reagents 8.19.5 Replacing ISE Test Reagents Other __________ AU480 User’s Guide Chapter 7 System Monitoring and Direct Observation Assign a reagent to fixed Results Test position 7.4 Reagent Management Other __________ 7.4.1 Fix (Assign) a Reagent Position Direct Observation Reagent Instructions for Use Identify reagent preparation Reagent Preparation Test Other __________ Calibration AU480 User’s Guide Direct Observation Determine analyzer calibration Chapter 5 Daily Startup Test status 5.5 Check Reagent Status Other __________ AU480 User’s Guide Direct Observation Perform analyzer calibration Chapter 5 Daily Startup Test 5.6 Perform Calibration Other __________ AU480 User’s Guide Direct Observation Chapter 8 Maintenance Perform ISE calibration 8.12 ISE Daily Maintenance Test Other __________ 8.12.2 ISE Calibration AU480, Customer, Competency Checklist Page 1 of 4 Version 1.0 (June 2016) Beckman Coulter Professional Development Competency Checklist
AU480 Chemistry Analyzer
Achieved? Trainee Trainer Task Resources How Measured? N/A Date Y N Initial Initial Process QC Direct Observation Perform daily QC Test Other __________ AU480 User’s Guide Direct Observation Order QC for multiple bottles Chapter 5 Daily Startup Test (Individual Requisition) 5.7 Perform Quality Control Other __________ (QC) Direct Observation Order and process QC for Test specific tests Other __________ Process Patient Samples Identify correct sample racks AU480 User’s Guide Direct Observation and containers for sample Chapter 6 Sample Programming Test processing and Processing Other __________ 6.1 Prepare Samples for Direct Observation Process bar coded samples in Analysis Test racks 6.2 Placing Racks on the Rack Other __________ Supply Unit Direct Observation Manually order samples for 6.3 Requisition for Routine and Test processing in racks Emergency Samples Other __________ Direct Observation Process bar coded samples in AU480 User’s Guide Test the STAT table Chapter 6 Sample Programming Other __________ and Processing Direct Observation Manually order sample for 6.5 Priority STAT Samples Test processing in the STAT table Other __________ Review Results AU480 User’s Guide Direct Observation Review Calibration Monitor Chapter 7 System Monitoring and Test Results Other __________ 7.3 Check Results Direct Observation 7.3.4 Check the Reagent Review QC Monitor Blank and Calibration Test Other __________ 7.3.5 Check QC
AU480, Customer, Competency Checklist Page 2 of 4
Version 1.0 (June 2016) Beckman Coulter Professional Development Competency Checklist
AU480 Chemistry Analyzer
Achieved? Trainee Trainer Task Resources How Measured? N/A Date Y N Initial Initial Review Results, continued AU480 User’s Guide Chapter 7 System Monitoring and Direct Observation Monitor Sample Status Results Test 7.1 Monitoring Analysis Other __________ 7.1.3 Sample Status Menu AU480 User’s Guide Direct Observation Chapter 6 Sample Programming Print results and Processing Test Other __________ 6.7 Print Results Direct Observation AU480 User’s Guide Identify flags Chapter 9 Error Flags Test Other __________ Maintenance Direct Observation Perform Daily Maintenance Test (ISE and Analyzer) Other __________ Direct Observation Perform Weekly Maintenance Test (ISE and Analyzer) Other __________ Direct Observation Perform ISE Every Other Week AU480 User’s Guide Test Maintenance (ISE only) Chapter 8 Maintenance Other __________ 8.3 Daily Maintenance Direct Observation Perform Monthly Maintenance 8.4 Weekly Maintenance Test (Analyzer only) 8.5 Monthly Maintenance Other __________ 8.6 Quarterly Maintenance Direct Observation Perform ISE Every Other Month 8.7 6-Month Maintenance Test Maintenance (ISE only) ISE (Option) Maintenance Other __________ Direct Observation Perform Quarterly Maintenance Test (ISE and Analyzer) Other __________ Direct Observation Perform 6-Month Maintenance Test (ISE and Analyzer) Other __________
AU480, Customer, Competency Checklist Page 3 of 4
Version 1.0 (June 2016) Beckman Coulter Professional Development Competency Checklist
AU480 Chemistry Analyzer
Achieved? Trainee Trainer Task Resources How Measured? N/A Date Y N Initial Initial Maintenance, continued AU480 User’s Guide Direct Observation Perform Yearly Maintenance Chapter 8 Maintenance Test (Analyzer only) 8.8 Yearly or As Needed Other __________ Maintenance Additional Procedures AU480 User’s Guide Direct Observation Set a new index Chapter 5 Daily Startup Test 5.1.2 Set the Start Conditions Other __________ AU480 User’s Guide Direct Observation Check Analyzer Status Chapter 5 Daily Startup Test 5.3 Check Analyzer Status Other __________ AU480 User’s Guide Chapter 7 System Monitoring and Direct Observation Perform an End Process Results Test 7.10 System Shutdown (End Other __________ Process) AU480 User’s Guide Chapter 7 System Monitoring and Direct Observation Perform and recover from an Results Test Emergency Stop 7.14 Perform an Emergency Other __________ Stop Direct Observation Test Other __________ Direct Observation Test Other __________ Direct Observation Test Other __________ Direct Observation Test Other __________
AU480, Customer, Competency Checklist Page 4 of 4
Version 1.0 (June 2016) Beckman Coulter Professional Development