Air Ducts Desgin

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

1/25/2020 Air ducts desgin

CUSTOM SEARCH ENGINE

Email Address
Custom Search
SUBSCRIBE

POPULAR POSTS

Home About Privacy Policy 


Requirements for installa
re sprinkler
Powered by Blogger
March 05, 2019
MEKASMART.club
LABELS FM-200 System .
March 03, 2019
 BOOKS FIRE FIGHTING

 Electrical
CENTRAL AIR CONDITION
HOME PDF  MEGA MENU  PDF FIRE VIDEOS DESIGN 
 Fire Fighting January 17, 2019

 HVAC
Home  HVAC  Air ducts desgin
 Programs
CATEGORIES
Air ducts desgin  SAFETY

MEP Engineering - January 03, 2019  VIDEOS

TAGS

SOCIAL PLUGIN
Air ducts design

How to design air ducts design    

  
Method of designing and calculating that weigh of the air duct

Now i will explain briefly the design of Air ducts and calculate its weight by FOLLOW BY EMAIL

example . Get all latest content delivered straight to
CUSTOM SEARCH ENGINEyour inbox.
https://www.mekasmart.club/2019/01/design-design-duct-design.html 1/10
1/25/2020 Air ducts desgin
CUSTOM SEARCH ENGINE
Air duct uses air conditioning systems to transfer cold air from the internal unit
to the place to be conditioning . Email Address
Custom Search

SUBSCRIBE

The duct is divided into

 Supply Air Duct ( S.A.D) POPULAR POSTS

 Return Air Duct ( R.A.D) Requirements for installa


re sprinkler
 Fresh Air Duct (F.A.D) Powered by Blogger
March 05, 2019
 Exhaust Air Duct (EX.A.D)
LABELS FM-200 System .
March 03, 2019
The Material from which the duct is made  BOOKS FIRE FIGHTING
 Galvanized steel  Electrical
CENTRAL AIR CONDITION
 stainless steel  Fire Fighting January 17, 2019
 textile (Fabric )  HVAC

 Aluminum Cladding  Programs


CATEGORIES
 SAFETY

 VIDEOS
Several factors must be considered when designing a duct system . Generally
in order of importance , they are as follows : TAGS

 Space availability
 Installation cost
 Air friction loss
 Noise level
 Duct heat transfer and air flow leakage
 Codes and standards requirements
Suppose That
1 T.R Take from (300 CFM TO 400 CFM ) but these number are appreciated .
Example
Assume that after calculation ( space area ) its needed to :
 3 T.R
 1200 CFM ( Assume 1 T.R take 400 cfm )
 Velocity = 600 fpm this value from velocity tables ( SMACNA code )

SOCIAL PLUGIN

   

  

FOLLOW BY EMAIL

Get all latest content delivered straight to
CUSTOM SEARCH ENGINEyour inbox.
https://www.mekasmart.club/2019/01/design-design-duct-design.html 2/10
1/25/2020 Air ducts desgin
CUSTOM SEARCH ENGINE

Velocity Table Email Address


Custom Search
SUBSCRIBE

POPULAR POSTS

Requirements for installa


re sprinkler
Powered by Blogger
March 05, 2019

LABELS FM-200 System .


March 03, 2019
 BOOKS FIRE FIGHTING

 Electrical
CENTRAL AIR CONDITION
 Fire Fighting January 17, 2019

 HVAC

 Programs
CATEGORIES
 SAFETY

 VIDEOS

TAGS

This part is pass it air flow rate (1200 cfm) . and the velocity it 600 fpm .
Enter the program
 Enter air flow rate = 1200 cfm.
 Enter the velocity = 600 fpm

SOCIAL PLUGIN

   

  

FOLLOW BY EMAIL

Get all latest content delivered straight to
CUSTOM SEARCH ENGINEyour inbox.
https://www.mekasmart.club/2019/01/design-design-duct-design.html 3/10
1/25/2020 Air ducts desgin
CUSTOM SEARCH ENGINE

Email Address
Custom Search
SUBSCRIBE

POPULAR POSTS

Requirements for installa


re sprinkler
Powered by Blogger
March 05, 2019

LABELS FM-200 System .


March 03, 2019
Click here ( on calculation ) to know friction
 BOOKS FIRE FIGHTING

 Electrical
CENTRAL AIR CONDITION
 Fire Fighting January 17, 2019

 HVAC

 Programs
CATEGORIES
 SAFETY

 VIDEOS

TAGS

Aspect ratio ( Width / high less than or equal 1 : 4)

Choose any value or according to aspect ratio


I choose 550 * 350 mm

1200 cfm divided to 600 cfm in first branch and 600 cfm in second branch

SOCIAL PLUGIN

   

  

FOLLOW BY EMAIL

Get all latest content delivered straight to
CUSTOM SEARCH ENGINEyour inbox.
https://www.mekasmart.club/2019/01/design-design-duct-design.html 4/10
1/25/2020 Air ducts desgin
CUSTOM SEARCH ENGINE
Enter the program the new value
Email Address
 Air flow rate = 600 cfm Custom Search
SUBSCRIBE
 Air velocity = 800 fpm

POPULAR POSTS

Requirements for installa


re sprinkler
Powered by Blogger
March 05, 2019

LABELS FM-200 System .


March 03, 2019
 BOOKS FIRE FIGHTING

 Electrical
CENTRAL AIR CONDITION
 Fire Fighting January 17, 2019

 HVAC

 Programs
CATEGORIES
 SAFETY

 VIDEOS
choose 550 * 200 mm TAGS

Assume that ( duct thickness 1 mm )

Vibration isolators (canves )

Its used to prevent vibrations resulting from the indoor unit to the related duct
with indoor unit ( FCU or AHU)

SOCIAL PLUGIN

   

  

Volume control dampers (VCD )


FOLLOW BY EMAIL

Get all latest content delivered straight to
CUSTOM SEARCH ENGINEyour inbox.
https://www.mekasmart.club/2019/01/design-design-duct-design.html 5/10
1/25/2020 Air ducts desgin
CUSTOM SEARCH ENGINE

Email Address
Custom Search

SUBSCRIBE

Volume damper is used to control the amount of air outside from the outlet air
POPULAR POSTS
Type of Volume damper :
 Manual Volume damper . Requirements for installa
re sprinkler
 Motorized Volume damper . Powered by Blogger
March 05, 2019

LABELS FM-200 System .


March 03, 2019
 BOOKS FIRE FIGHTING

 Electrical
CENTRAL AIR CONDITION
 Fire Fighting January 17, 2019

 HVAC

 Programs
CATEGORIES
Fir damper (F.D)  SAFETY

Fire Damper is installed on return duct . to prevent smoke from entering the  VIDEOS
AHU and passing smoke from place to place during Fire .
TAGS

Plenum box
Plenum box is installed on diffuser

SOCIAL PLUGIN

   
Flexible duct
Its a flexible duct used to connected the outlet air and the duct and easy move   
the outlet air

FOLLOW BY EMAIL

Get all latest content delivered straight to
CUSTOM SEARCH ENGINEyour inbox.
https://www.mekasmart.club/2019/01/design-design-duct-design.html 6/10
1/25/2020 Air ducts desgin
CUSTOM SEARCH ENGINE

Email Address
Custom Search
SUBSCRIBE

POPULAR POSTS

Type of flexible duct Requirements for installa


 Air connector Powered by Blogger
re sprinkler
March 05, 2019
 Air duct
LABELS FM-200 System .

Duct leakage Test March 03, 2019


 BOOKS FIRE FIGHTING
 Smoke Test .
 Electrical
CENTRAL AIR CONDITION
 Light Test.
 Fire Fighting January 17, 2019
 Pressure Test .
 HVAC

 Programs
Duct Wight CATEGORIES
 SAFETY

Wight = 2 * ( W + H ) * L * T * density  VIDEOS

TAGS
 W : duct wight
 H : duct depth
 L : duct Length
 Duct thickness
 Density = 7850 kg / kg3

Air Terminal Outlet


Advantages of uses Air Terminal outlet
 Distribute the air place well
 Give an aesthetic shape to the place

Type and shape of Air Terminal outlet :


SOCIAL PLUGIN
 Square diffuser
 Round diffuser
   
 Swirl diffuser
 Slot diffuser   
 Jet diffuser
 Perforated diffuser
FOLLOW BY EMAIL
 Air grille and register 
Get all latest content delivered straight to
CUSTOM SEARCH ENGINEyour inbox.
https://www.mekasmart.club/2019/01/design-design-duct-design.html 7/10
1/25/2020 Air ducts desgin
CUSTOM SEARCH ENGINE
 Fresh air lover
Email Address
 Disk Valve Custom Search

SUBSCRIBE
 Door grille and under cut

Factors that influence the selection of air outlet


 Ceiling Type and Decoration
POPULAR POSTS
 Ceiling high
 Construction Requirements for installa
re sprinkler
Powered by Blogger
March 05, 2019
Square Diffuser
LABELS FM-200 System .
March 03, 2019
 BOOKS FIRE FIGHTING

 Electrical
CENTRAL AIR CONDITION
 Fire Fighting January 17, 2019

 HVAC

 Programs
CATEGORIES
 SAFETY

 VIDEOS

TAGS

Square diffuser : two size ( neck size and face size ) .

Factors influencing the determination of output size


 Air flow Rate ( CFM)
 Noise Criteria (NC)
 Throw
To determine the nick size (from catalogue or equation) .

Q=A*V
Q : air flow rate cfm
A :diffuser area ( X * Y ) SOCIAL PLUGIN

V: velocity
   

  

FOLLOW BY EMAIL

Get all latest content delivered straight to
CUSTOM SEARCH ENGINEyour inbox.
https://www.mekasmart.club/2019/01/design-design-duct-design.html 8/10
1/25/2020 Air ducts desgin
CUSTOM SEARCH ENGINE

Email Address
Custom Search
SUBSCRIBE

POPULAR POSTS

Requirements for installa


re sprinkler
Powered by Blogger
March 05, 2019

LABELS FM-200 System .


March 03, 2019
 BOOKS FIRE FIGHTING

 Electrical
CENTRAL AIR CONDITION
 Fire Fighting January 17, 2019

 HVAC

 Programs
CATEGORIES
 SAFETY

 VIDEOS

TAGS

To download the program Ductulator

DOWNLOAD
SOCIAL PLUGIN

Thank You
   
Tags HVAC
  
REACTIONS

 Facebook  Twitter      FOLLOW BY EMAIL



Get all latest content delivered straight to
your inbox.
https://www.mekasmart.club/2019/01/design-design-duct-design.html 9/10
1/25/2020 Air ducts desgin
funny (0) interesting (0) cool (0) YOU MAY LIKE THESE POSTS
Email Address

HVAC HVAC HVAC


SUBSCRIBE

Chiller and Chilled Water Pumps


POPULAR POSTS
pumps Hock System January 22, 2019
up March 10, 2019
Requirements for installa
August 19, 2019
re sprinkler
March 05, 2019
POST A COMMENT
FM-200 System .
March 03, 2019
0 Comments

CENTRAL AIR CONDITION


Enter your comment... January 17, 2019

CATEGORIES
RECENT POSTS CATEGORIES FEATURED POST

Electrical Current Basics  BOOKS FIRE FIGHTING 3


HVAC TAGS
August 25, 2019  HVAC 9

 Programs 3

How Inverters Work


August 23, 2019 TAGS

BOOKS FIRE FIGHTING HVAC Programs


How Electricity Works
August 22, 2019
CENTRAL AIR CONDITIONING
January 17, 2019
CUSTOM SEARCH ENGINE

Custom Search

Copyright © 2020 MEKASMART.club Home About Privacy Policy

https://www.mekasmart.club/2019/01/design-design-duct-design.html 10/10