Pesco: Isometrics For Raw Water and Service Water Distribution System Aden Power Plant - Phase 1

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6 7 8

PART MATERIAL DESCRIPTION SIZE ITEM CODE QTY. SPEC


No

ERECTION MATERIALS
N
1 Plain piping, Grooved end, 150 PAAZZCIAEABAABOAAZZUS 0.3 M
Galvanized,ASME-B36.10M,
A53-B, ERW, S-40
A 2 Victaulic No.53 Concentric 150X100 MBCZZCIAEAAEBGWZZUS 1 B10F A
Swaged Nipple, Male grooved
end, Galvanized,ASTM A536
Grade 80-55-06, NREQD
3 Victaulic Style 75, Flex 150 MAKZZDXZZDAYBOKZZUM 2 B10F
Coupling, Female Grooved Ends,
403 150X150DN
4 Victaulic Style 75, Flex 100 MAKZZDXZZDAYBOKZZUM 1 B10F
Coupling, Female Grooved Ends, C3
403
5 Victaulic No.45F Flange 100 FAIAHAAZZAADBGWZZUS 1 B10F SEE ISO
10PCB04BR001
Adapter Nipple, Flat face E 297835
flanged end x Grooved End, N 334325
ASTM A536 Grade 80-55-06, EL +2102
6 Flat gasket, non-metallic, 100 ADAHANAABGYUS 1 B10F
CL150, 3.2mm, ASME-B16.21,
B Compressed Non Asbestors Fiber B
7 Stud Bolt, ASME-B18.2.1, ASTM 5/8 BAZZZZZZAAYBEZZUS 8 B10F
A193-B7, hot Dip Galvanised,
With 2 heavy Hex nuts A194

<1> 1
Gr.2H (Hot dip Galvanised) and
2 washers - 100 mm Length

C C

229
456
150DN
D D

CONN TO
C3 10PCB02AP001/PUMP DISCHARGE
2 100 MM RFFE 150
150X100DN E 297835
N 334325
C4 EL +1639

PUMP PESCO
91
E F5 G6 B7 E
128
OWNER

VENDOR
DISTRIBUTION W/C
MATRIX

1 229 150 SQ.CUT SQ.CUT PAAZZCIAEABAABOAAZZUS NOTES:- EPC


PIECE
NO
LENGTH
MM
SIZE
MM
END PREP END PREP ITEM CODE
1. ALL DIMENSIONS AND ELEVATIONS ARE IN MILLIMETERS
2. FINISHED GROUND LEVEL (FGL) OF PLANT IS (-)0.300 WHICH
CORRESPONDS TO MSL (+)8.50M
PESCO
3. FOR PAINTING & SURFACE PREPARATION DETAILS REFER "TECHNICAL
SPECIFICATION FOR PAITING" DOC NO. TCE.11191A-SP-3903 MAIN PLANT EQUIPMENT SUPPLIER
4. FOR INSULATION DETAILS REFER "TECHNICAL SPECIFICATION FOR
INSULATION" DOC NO. TCE.11191A-SP-3902
5. ALL ELEVATIONS INDICATED ARE CENTER LINE OF PIPES UNLESS
OTHERWISE NOTED. PROJECT NAME
6. SMALL BORE PIPING (DN 50 & BELOW) ARE FIELD RUN. ISOMETRICS
ISSUED FOR THE SAME IS INDICATIVE AND MAY BE ADJUSTED TO SUIT ADEN POWER PLANT - PHASE 1
F SITE CONDITIONS. F
7. FOR SUPPORT ARRANGEMENT, REFER TYPICAL STANDARD SKETCH
DRAWING - TCE.11191A-D-4909 DRAWING TITLE ISOMETRICS FOR RAW WATER AND SERVICE
8. VICTAULIC PIPE FITTINGS SHALL NOT REST ON SUPPORTS AND SHALL
R0
WATER DISTRIBUTION SYSTEM
HAVE AMPLE CLEARANCE FROM SUPPORT.
10PCB02BR002 01 of 01
P&ID NO. ENGINEERING JOB No. DRAWING NUMBER REV
PIPING LAYOUT DRAWING NO. No. DATE REVISION DESCRIPTION BY CHK APPR Civil Mech Elect I/C PIP HSE PROS
11191A TCE.11191A-D-4916 R0
FILE NAME 10PCB02BR002.SHA DATE : DESIGNED : DRAWN : CHEF ENGR : TATA CONSULTING ENGINEERS LIMITED

1 2 3 4 5 6 7 8