Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

FINISHED GRADE

SPECIFIED
PAVEMENT PAVEMENT
RESTORATION

MIN
300
CEMENT

MINIMUM
STABILIZED FILL

1000
IN ACCORDANCE COMPACTED
WITH CW 2160 EXCAVATED

VARIES
MATERIAL
CLASS 2 BACKFILL:

VARIES
COMPACTED
COMPACTED OR TYPE 1 FILL
FLOODED, JETTED CLASS 3 BACKFILL:
AND TAMPED FLOODED, JETTED
TYPE 1 FILL AND TAMPED
TYPE 1 FILL

BEDDING AND
BEDDING AND
INITIAL BACKFILL
INITIAL BACKFILL
IN ACCORDANCE
IN ACCORDANCE
WITH SD-001
WITH SD-001

CLASS 1 BACKFILL CLASS 2 AND CLASS 3 BACKFILL

SPECIFIED
RESTORATION

FINISHED GRADE

CLASS 4 BACKFILL:
COMPACTED
EXCAVATED MATERIAL

CLASS 5 BACKFILL:
VARIES

FLOODED, JETTED
AND TAMPED
EXCAVATED MATERIAL

BEDDING AND
INITIAL BACKFILL
(SEE SD-001)

CLASS 4 AND CLASS 5 BACKFILL

DIMENSIONS IN MILLIMETERS

THE CITY OF WINNIPEG Reference Spec. No.


CW 2030 CW 2160
WATER & WASTE DEPARTMENT
Designed By: Drawn By: Scale:
TW BH N.T.S.
STANDARD TRENCH AND Checked By: Date: 04-02-16
Drawing No.
EXCAVATION BACKFILL TW Revision: 2

CLASSES Approved:
SD-002
UNDERGROUND WORKS COMMITTEE