Download as pdf or txt
Download as pdf or txt
You are on page 1of 37

KM/CS-2560/3060 Firmware Release Notes

Subject: Firmware Update


Model KM/CS-2560/3060
Updated Machines
N/A
Serial Number:

KM/CS-2560/3060 Combined Firmware Ver 2.49

Problem 1

If the machine enters sleep mode under toner Low conditions (“Toner low” message on display), the following
operation will be repeated.

After 10 seconds, the main unit starts. Æ Warm-up operation runs for 40 seconds and stops.
Æ 10 seconds later, warm-up operation restarts and continues for 40 seconds.

The new security level setting was added in Ver. 2.42. It was programmed that the HD be accessed to read the
security level when renewing the sub-message. When the HDD is accessed after entering sleep mode, the Engine
was instructed to come out of sleep mode.

The following actions shall be repeated.

(1) Enter sleep mode.


(2) Issue the sub-message after detecting a toner low condition.
(3) Access HDD to read the security level setting. 10 sec.
(4) Come out of sleep mode to access HDD (Engine power ON)
(5) Start warm-up operation. 40 sec.
(6) End warm-up operation.
(7) Enter sleep mode.

MAIN F/W: HDD will not be accessed at the sub-message renewal while in the power saver or sleep mode.
MMI2 F/W: Basic information will not be acquired when renewing the sub-message.

Problem 2

After replacing the toner container, “Adding toner” message displays and even when the operation is completed,
“Please wait” or ”Adjusting” message may continue to display disabling the machine.

• There may be no change after 10 minutes or so and pressing the operation unit power button does not turn
the power OFF. Cycling the main power switch will solve this issue.
• Even while “Please wait” or “Adjusting” message are being displayed, FAX reception is available and
function key and status key are responsive.

While the “Replaced toner container?” dialogue is normally displayed from the toner empty display screen when
the front cover is closed after replacing the toner container, in very rare cases, the dialogue may display before the
toner empty screen closes. When the toner empty screen closes in that condition, the dialogue becomes inactive,
disabling the operation panel.

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Preventive Measure

The “Replaced toner container?” dialogue will not be displayed before closing the toner empty screen.

Firmware Information

Program No. Check SUM Version Remarks


MAIN 2H0_2F00.039.001 ---------- 039.001 Å New Upgrade
ENGINE 2H0_1000.014.001 ---------- 014.001
MMI2 2H0_7A00.039.001 ---------- 039.001 *1 *2 Å New Upgrade
* 1 After updating the Firmware, the MMI2 Firmware Version will be displayed two ways depending upon
which Type Operation Panel PCB is installed in the MFP.

Operation Panel PCB MMI2 Version


Old Type 2H0_7000.xxxx
New Type 2H0_7A00.xxxx

* 2: This latest firmware can also be used on the existing Panel PWB (*1).

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Previous Changes

KM/CS-2560/3060 Combined Firmware Ver 2.48

Details of Changes
No. Modification Item Details
1 Measure for font error on While the scanner version on the service status page is supposed to be blank,
Service Status Page meaningless characters may be indicated. This has been corrected to leave the
space blank.

2 Preventing the JOB name When storing the file in Document BOX, if the file name containing umlaut fonts is
error for Document BOX sent through a driver other than the KX driver after setting the file name as a JOB
name, the following problem may occur. This has been corrected.
1) After shifting from “Application” to “KYOcontrol personal pringjob”, the JOBlist (JOB
name) in the Document BOX may become blank.
2) A font error may occur to the JOB name in Document BOX.

[Change]
When storing in Document BOX, it has been modified so the incorrect character is
displayed as “?”.

3 Correcting the returned value Returned value at OID 1.3.6.1.2.1.43.10.2.1.4.1. (Life Counter) is incorrect. This has
at been corrected.
OID1.3.6.1.2.1.43.10.2.1.4.1.
(Life Counter)

4 Measure for the problem When using the option NIC (SEH), a “PCL XL error” may trigger with the PDF file
when option NIC is used printing. This has been corrected.

5 Preventing form overlay After the form overlay output is performed, the form overlay may be applied to the
when outputting the report report output, such as status page, FAX communication report, etc. This has been
corrected. (No problem is expected once the power is turned OFF or the form overlay
is canceled.)

6 Measure for a C0130 error When writing to or reading from EEP-ROM, the file open/close process may fail,
triggering a C0130 error. As a measure, retry process has been changed or added
C0130: for each.
Backup memory (EEP-ROM) [Change]
device problem (Main PWB) • When opening the file: Retry process is increased. 50 Æ 1500 times.
Reading from or writing to • When closing the file: Retry process is added. (1500 times)
EEPROM cannot be
performed

7 Measure for the start key If you open the detail screen from the basic screen in the operation panel and then
malfunction the software keyboard screen within 2 seconds (leaving the software keyboard screen
on for more than 2 seconds), the start key would not become in ready status after
closing the software keyboard screen and changing to the detail screen. This has
been corrected.
(It will recover if you open the detail screen again.)

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Firmware Information
Check
KM-2560/3060 Program No. VERSION Remarks
SUM
MAIN 2H0_2F00.037.001 ---------- 037.001 Å New upgrade
ENGINE 2H0_1000.014.001 ---------- 014.001
MMI2 2H0_7A00.037.002 ---------- 037.002 *1 *2 Å New upgrade

* 1 After updating the Firmware, the MMI2 Firmware Version will be displayed two ways depending upon
which Type Operation Panel PCB is installed in the MFP.

Operation Panel PCB MMI2 Version


Old Type 2H0_7000.xxxx
New Type 2H0_7A00.xxxx

* 2: This latest firmware can also be used on the existing Panel PWB (*1).

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes
Previous Changes
KM/CS-2560/3060 Combined Firmware Ver 2.47A

Details of Changes
No. Item Details
1 Productivity enhancement Firmware is upgraded to improve productivity at production line.
at production line

Firmware Information

Check
KM-2560/3060 Program No. Version Remark
SUM
MAIN 2H0_2F00.036.001 ---------- 036.001
ENGINE 2H0_1000.014.001 ---------- 014.001 Å New upgrade
MMI2 2H0_7A00.035.002 ---------- 035.002 *1 *2

* 1 After updating the Firmware, the MMI2 Firmware Version will be displayed two ways depending upon
which Type Operation Panel PCB is installed in the MFP.

Operation Panel PCB MMI2 Version


Old Type 2H0_7000.xxxx
New Type 2H0_7A00.xxxx

* 2: This latest firmware can also be used on the existing Panel PWB (*1).

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Previous Changes

KM/CS-2560/3060 Combined Firmware Ver 2.45

Details of Changes
Modification Details
Measure for FAX As a preventative measure, Firmware is upgraded for FAX transmission/reception failure
transmission /reception and panel lock-up. It can reset by turning the main switch OFF/ON and the Received
failure and panel lock-up FAX would output normally.

The problem may occur with the following firmware.


F/W Ver. 2.43/2.44
MAIN 2H0_2F00.033.016/ 2H0_2F00.034.003

Firmware Information
Type Program No. Check SUM Version Remark
MAIN 2H0_2F00.034.100 ---------- 034.100 New Upgrade
ENGINE 2H0_1000.013.004 ---------- 013.004
MMI2 2H0_7A00.034.001 ---------- 034.001 *1

* 1 After updating the Firmware, the MMI2 Firmware Version will be displayed two ways depending upon
which Type Operation Panel PCB is installed in the MFP.

Operation Panel PCB MMI2 Version


Old Type 2H0_7000.xxxx
New Type 2H0_7A00.xxxx

Version 2.44 was not released to the field

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Previous Changes

KM/CS-2560/3060 Combined Firmware Ver 2.43

Summary of Changes

1. Measure to prevent both ends of the image from being cut off when receiving FAX data
(Reduction priority setting)
2. New message added during the data processing operation
3. Support for Scan to SFU/DBA
4. Measure for CF423 error
5. Measure for white void area on the image
6. Correcting a failure to delete the document in Twain Scan

Firmware Information

KM-2560/3060 Program No. Check SUM VER. Remarks


MAIN 2H0_2F00.033.016 ---------- 033.016 New Upgrade
ENGINE 2H0_1000.013.004 ---------- 013.004 New Upgrade
MMI2 2H0_7A00.033.014 ---------- 033.014 *1 New Upgrade

* 1 After updating the Firmware, the MMI2 Firmware Version will be displayed two ways depending upon
which Type Operation Panel PCB is installed in the MFP.

Operation Panel PCB MMI2 Version


Old Type 2H0_7000.xxxx
New Type 2H0_7A00.xxxx

Note: Please instruct the end-user not to turn the power OFF while writing/processing data into HDD.

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Details of Changes:
Item Details
1 Measure to prevent both ends (Example)
of image from being cut off When the original of A4 width and undefined length in vertical scanning direction is
when receiving the FAX data received and printed on B5 size paper, the received image will be printed with 100%
(Reduced image as priority magnification rate. As a result, both ends of the image may be cut off. This has been
setting) * corrected.

* Factory setting:
Same size priority
2 New message added during When a machine lockup or system error, etc. occurs, the internal process data is
the data processing operation automatically recorded and saved in HDD and requires approximately 5 minutes. We have
added a new message to instruct end-user not to turn the power OFF.

Self-diagnosing… Please wait.


New message
The system will be restarted automatically.
Do not turn off the main power switch.

3 Support for Scan to SFU/DBA Support for Scan File Utility/ DB assistant.
Please set maintenance mode U510 (Enterprise mode).
Please see details on the next page.
4 Measure for CF423 error When transmitting a Fax using the address book (stored in controller), the address book
information will be transferred to the Fax board to synchronize every time the Fax
transmission is complete. If an internal error occurs due to a data error, etc., a CF423
error may trigger. The following change has been carried out to address the issue.
[Change]
If there is no change on the Address Book information. The data will no longer be sent to
the Fax board.
5 Measure for a white void In very rare cases, a white void may occur on a printer output image, approximately 36mm
image wide in the main scanning direction.
(This does not occur to the same position or every print)

If a task is duplicated in the internal processing, the temporary data is overwritten. As a


result, the image starting point may be located outside of the printable image area, causing
the white void to occur. This has been corrected.
Approx.
Output direction 36mm

6 Correcting the failure to delete Even if Twain Scan is executed with the setting of “delete after acquiring data” using Adobe
the document in Twain Scan acrobat, an error message “The document deletion is failed” may display, failing to delete
the data in the BOX. This has been corrected.

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes
Support for DB assistant
To activate the DB assistant, please set to “3” in Maintenance mode U510 (Enterprise mode).

MAITENANCE MODE
SELECT THE MAINTENANCE U510
SET ENTERPRISE MODE

MODE 3 +

-
Set the MODE to 2 or 3.
+/-

Setting in U510 (Enterprise mode)

MODE Setting KYOCaputure Scan File Utility DBA


0 OFF OFF OFF
1 ON OFF OFF
2 OFF ON OFF
3 OFF OFF ON

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Previous Changes
KM/CS-2560/3060 Combined Firmware Ver 2.42A

Details of Changes
Item Details
1 Addition of flash memory The Numonyx flash memory device is now supported.
device

2 Support for Fax System (M2) FAX SYSTEM (M2) is supported. Fax System (M2) replaces Fax System (M) and is
compatible with the 2560/3060 only. The combined Firmware Pack 2.42A will include
both the Fax System (M) and Fax System (M2) Firmware and will upgrade each
accordingly

3 Equitrac system support Equitrac system support is implemented.


(Activation by AC-1 is
required. *1) Equitrac system configuration:
Equitrac Office4, Equitrac Express4, IC card reader by Equitrac

*1: The AC-1 is not required for a trial mode.

4 Addition of Security Level “Security Level” and “System Administrator” are newly added for the security level items.
setting See the following page.

Firmware Information
2560/3060 Program No. Check SUM Version Remark
MAIN 2H0_2F00.032.004 ---------- 032.004 New upgrade
ENGINE 2H0_1000.012.001 ---------- 012.001
MMI2 2H0_7A00.032.004 ---------- 032.004 *1 New upgrade
FAX APL M 3KH_5100.011.001 011.001 For type M
FAX BOOT M 3KH_5000.009.001 009.001 For type M
FAX APL M2 3KH_5100.N04.003 N04.003 For type M2
FAX BOOT M2 3KH_5000.001.022 001.022 For type M2

* 1 After updating the Firmware, the MMI2 Firmware Version will be displayed two ways depending upon
which Type Operation Panel PCB is installed in the MFP.

Operation Panel PCB MMI2 Version


Old Type 2H0_7000.xxxx
New Type 2H0_7A00.xxxx

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

・ Addition of Security Level setting (Not to be changed in normal circumstances.)


Addition of “Security Level” ----- Default: High
System menu Æ Security level Æ (Login ID/Login password Æ Low or High

System

Network Next Parallel setting Change

Restart Execute

Network security Next Security level Change


New addition, Security Level

Adding the “Device Administrator”

A Device Administrator can change the SECURITY Level to a High or Low Setting from the System Menu,
under Security Level, by the addition of “Device Admin” under the User Login/Job Accounting Local User
List

FAX System (M) and Fax System (M2) Compatibility

The Fax System Firmware is upgraded to prevent a Firmware compatibility issue (C0700 Error) with a Fax
System (M2) installed to a 2560/3060.

The C0700 Error can occur when you are upgrading Firmware using an older version Combined Upgrade
Pack of 2.40 or below which contains Fax System (M) Firmware and is loaded on a MFP with the new Fax
System (M2) installed.

The combined Firmware Pack 2.42A will include both the Fax System (M) and Fax System (M2) Firmware
and will upgrade each accordingly.
Precaution:

Fax System (M) and Fax System (M2) cannot be combined into the same MFP. You must use two
Fax System (M)’s or two Fax System (M2)’s.

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Identifying FAX SYSTEM (M) / FAX SYSTEM (M2)

A Blue Dot Label is applied on the mount of Fax PWB.

The color of the connector at the Fax PWB side is different.

FAX System (M) FAX System (M2)


Color of connector (Fax board side) Black Gray
Identification ----- Blue Dot

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes
Previous Changes
KM/CS-2560/3060 Combined Firmware is upgraded to Version 2.40.

Details of Changes
No. Item Content
1 Measure for noise The fixing heater control is a phase control to prevent flickering of the fluorescent lights in
generating from the Power the room. However, it came to our attention that noise may generate from the Power
Supply PCB Supply PCB in conjunction with the phase control.
We have added a new maintenance mode to set the phase control ON/OFF during the
stand-by mode only.

Maintenance mode U198 (Setting the fuser phase control)


ON: Phase control enabled (Default: Same as now) OFF: Phase control disabled

Note: You may experience flickering of the fluorescent lights when selecting the OFF
setting. The OFF setting disables the phase control for fixing heater during a stand-by
mode.

2 Measure to prevent a Received FAX image data will be compressed when storing to the HDD. In some cases
CF323 error (an image with a large percentage of gray background), the compressed data may be
larger than the available size in HDD. In this case, a process time-out occurs, triggering
a CF323 error. This has been corrected.

3 Measure for an output AppleTalk cannot print a certain PDF file which displays a f timeout error or job stop
failure of a certain PDF message. This has been corrected.
file by Apple Talk

4 Measure for a failure to At the machine startup, the emulation setting, PCL6, cannot be changed. This has been
change emulation at corrected.
machine startup
5 Support for enabling
JAVA application
installation

Firmware Information
KM-2560/3060 Program No. Check SUM Version Remarks
MAIN 2H0_2F00.030.001 ---------- 030.001 New upgrade
ENGINE 2H0_1000.012.001 ---------- 012.001 New upgrade
MMI2 2H0_7A00.030.001 ---------- 030.001 *1 New upgrade
* 1 After updating the Firmware, the MMI2 Firmware Version will be displayed two ways depending upon
which Type Operation Panel PCB is installed in the MFP.

With Old Panel PCB installed: 2H0_7000. ***.*** With New Panel PCB installed: 2H0_7A00. ***.***

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Previous Changes

KM/CS-2560/3060 Combined Firmware 07/09

Details of Changes
No. Item Details
1 Measure for a C6050 An error code C6050 may trigger after pressing the start key to make a reserved copy or
sending a Job from the printer during the machine warm-up or immediately after coming out
of sleep mode. This has been corrected.
C6050: [Measure]
Abnormally low fuser Control temperature during the drum refresh operation has been increased to 165 degree
temperature C, same as in the stand-by mode.

2 Measure to prevent a If a printer Job is received during the drum refresh operation, output will not occur locking in
printer output failure a Job process mode. This has been corrected
locking in a Job process
mode

Firmware Information
KM-2560/3060 Program No. Check SUM VERSION Remarks
MAIN 2H0_2F00.024.001 ---------- 024.001
ENGINE 2H0_1000.012.001 ---------- 012.001 Upgraded
MMI2 2H0_7A00.024.001 ---------- 024.001 *1

* 1 After updating the Firmware, the MMI2 Firmware Version will be displayed two ways depending upon
which Type Operation Panel PCB is installed in the MFP.

Operation Panel PCB MMI2 Version


Old Type 2H0_7000.xxxx
New Type 2H0_7A00.xxxx

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Previous Changes
KM/CS-2560/3060 Combined Firmware is upgraded to Version 2.20D1.

Details of Changes
Item Details
1 Measure for C0630 In some cases, a C630 may trigger after feeding the final original from the DP. This has been
corrected.
C0630:DMA problem

2 Energy Star Compliant The duration when the fixing heater is ON has been changed to reduce power consumption.

Firmware Information
Type Program No. Check SUM Version Remarks
MAIN 2H0_2F00.024.001 ---------- 024.001
ENGINE 2H0_1000.011.003 ---------- 011.003 Updated
MMI2 2H0_7A00.024.001 ---------- 024.001 *1

* 1 After updating the Firmware, the MMI2 Firmware Version will be displayed two ways depending upon
which Type Operation Panel PCB is installed in the MFP.

Operation Panel PCB MMI2 Version


Old Type 2H0_7000.xxxx
New Type 2H0_7A00.xxxx

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Previous Changes
The KM/CS-2560/3060 Combined Firmware is upgraded to Version 2.20D.

Summary of changes:

1. Measure to prevent a problem with a FAX RX JOB/CF47F/CF46F.


2. Measure to prevent a problem with a FAX TX/RX JOB.
3. Support when DNS1 is down (not functioning)

Details of changes:
Item Details
1 Measure to prevent a There might be the possibility that a FAX RX JOB does not output during processing
problem with a FAX RX or a CF47F/CF46F might occur.
JOB/CF47F/CF46F. This has been is corrected.

2 Measure to prevent a When sending a FAX, after selecting the destination and the scanning operation
problem with a FAX completes, TX JOB does not connect but keeps processing. An RX Job can be
TX/RX JOB completed correctly but the RX JOB cannot be output and keeps processing. This
has been corrected.

3 Support when DNS1 is Even if both the primary DNS (DNS1) and secondary DNS (DNS2) is set, if DNS1
down (not functioning) is down (not functioning), there may be the possibility that it will not access DNS2
and a communication will not occur. This has been corrected.

Firmware Information

Type Program No. Check SUM VER. Remarks


MAIN 2H0_2F00.024.001 ---------- 024.001 Upgraded
ENGINE 2H0_1000.010.004 ---------- 010.004
MMI2 2H0_7A00.024.001 ---------- 024.001 *1 Upgraded

* 1 After updating the Firmware, the MMI2 Firmware Version will be displayed two ways depending upon
which Type Operation Panel PCB is installed in the MFP.

Operation Panel PCB MMI2 Version


Old Type 2H0_7000.xxxx
New Type 2H0_7A00.xxxx

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes
Previous Changes
The KM/CS-2560/3060 Combined Firmware is upgraded to Version 2.20C.
Summary of Changes:

1. Addition of new display for total remaining capacity on the FAX Box screen.
2. Scanner image quality enhancement.
3. Correction on U632 (DIS 4BYTE) ON/OFF setting
4. Correcting a problem with iFAX reception/mail print from certain servers.
5. Change of font size for JAM code display.
6. Measure for Fax reception/print failure after entering the partial operation control mode.
7. Change to JOB display while waiting for FAX re-dial.
8. Measure for a lockup during FAX reception.
9. Measure for missing image at the left edge with certain PCL data.
10. Measure for panel lock with the software keyboard.
11. Measure for decrease in panel response speed.
12. Font error may occur when printing the data (Unicode spool file) that is output under a SAP
environment.
13. Measure for partial background image when printing certain PDF data.
14. Measure for KPDL error.
15. Measure for CF33F.
16. Measure for CF620.
17. Changing the method of displaying/resetting the error code C6020 (abnormally high fuser unit
thermistor temperature)
18. Panel response enhancement.
19. Improving panel operation.
20. Measure for CF423/CF323.
21. Measure for CFB2C.
22. Measure to prevent a lockup after changing the setting from system menu.
23. Measure for an incorrect message when staple setting is made without setting originals.

Firmware Information
Type Program No. Check SUM Version Remark
MAIN 2H0_2L00.014.006 ---------- 014.006 New upgrade
ENGINE 2H0_1000.010.004 ---------- 010.004
MMI2 2H0_7A00.014.014 ---------- 014.014 *1 New upgrade

FAX APL ---------- ---------- 3KH_5100011001


FAX BOOT ---------- ---------- 3KH_5000009001
FAX BOOT/APL S2KH_5500011001 ---------- ----------
MIX F/W

Please upgrade all firmware to the latest versions at the same time whenever upgrading firmware and/or
replacing the board.

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

* 1 After updating the Firmware, the MMI2 Firmware Version will be displayed two ways depending upon
which Type Operation Panel PCB is installed in the MFP.

Operation Panel PCB MMI2 Version


Old Type 2H0_7000.xxxx
New Type 2H0_7A00.xxxx

(Details of Changes)

1. Addition of new display for total remaining capacity on the FAX Box screen

When the CF backup kit is installed, the remaining capacity has been added on the FAX Box screen.
In addition, a change is made to display number of stored document per BOX.

Display the total remaining capacity for FAX confidential BOX on the FAX Box screen.
Display the used capacity by each Box of FAX Box

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

2. Scanner image quality enhancement

A change is made to the image process filter to improve the Color scanner image with (JPEG, PDF,
TIFF). New Maintenance mode U470 has been added so the compression ratio setting can be
changed.

JPEG/PDF/TIFF image quality setting (5 steps)

U470 [Set JPEG Compression rate] has been added to make the compression ratio for each step
changeable.

Default setting
Set compression rate 1 2 3 4 5
Old 10 30 50 70 90
New 30 40 50 80 95

Image Example: Resolution: 300dpi, Compression ratio: 1, TEXT/PHOTO mode

Before change After change (Noise or moiré are reduced)

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

3. Correction on U632 (DIS 4BYTE) ON/OFF setting

The actual operation of maintenance mode U632 (DIS 4BYTE: DIS signal 4 bite fixed) differs from
the service manual and other existing models and the ON/OFF setting works conversely in the actual
operation. This has been corrected.

Operation before change Operation after change

ON --> DIS will not be controlled (Default) ON --> DIS will be 4byte
OFF --> DIS will be 4byte OFF --> DIS will not be controlled (Default)

U632 Setting Operation Contents


--> DIS will not be controlled
Actual operation ON Execute to move after Bit33 of DIS/DTC signal (Default)
--> DIS will be 4byte
(Current) OFF Do not execute to move after Bit33 of DIS/DTC signal


↕ Operation of ON/OFF is different
Contents is different from the setting

--> DIS will be 4byte
Service Manual ON Do not execute to move after Bit33 of DIS/DTC signal
--> DIS will not be controlled
Existing model OFF Execute to move after Bit33 of DIS/DTC signal

4. Correcting a problem with iFAX reception/mail print from certain server

iFAX RX/mail print cannot be received correctly through certain providers. This has been corrected.
(The problem occurs when the amount of data specified by server and the actual data do not match.)

5. Change of font size for JAM Code display

The Font size of the error code on JAM screen and Service Call screen has been changed from 16p
to 24p.

6. Measure for Fax reception/print failure after entering the partial operation control mode

If the paper cassette for printing the received FAX enters the partial operation control mode, even if
FAX is received, it may fail to be printed due to unavailability of applicable size paper. It has been
modified so in this situation, an "Out of paper" message will be displayed.

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

7. Change to JOB display while waiting for FAX Re-dial

During the Fax transmission when waiting for re-dial on the JOB, status screen displays “Sending”.
This is confusing and not clear whether the JOB is still waiting to be sent or is actually being sent and
ultimately it may be mistaken as a machine lockup. The status screen message for waiting for FAX
re-dial has been changed from "Sending" to "Waiting".

8. Measure for a lockup during FAX reception

If a Print Over Run occurs during the FAX RX printing, the panel may lockup instead of displaying an
error message. This has been corrected.

9. Measure for missing image at the left edge with certain PCL data

The image at the left edge may not be printed when using certain PCL data. This has been corrected.

10. Measure for panel lock with the software keyboard

The panel may lockup if the software keyboard is opened immediately after turning the power source
ON, etc. This has been corrected.

11. Measure to increase panel response speed

When using the machine continuously for a long period of time, the panel may lock up or the panel
response speed may decrease due to memory shortage or damage to the memory. This has been
corrected.

12. Font error may occur when printing the data (Unicode spool file) that is output under a SAP
environment

13. Measure for partial background when printing certain PDF data

When printing certain PDF data, the image may be printed with background. This has been
corrected.

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

14. Measure for KPDL error

A KPDL error may occur when printing certain file. This has been corrected.

15. Measure for CF33F

A CF33F may trigger when printing with KM Driver in certain settings. This has been corrected.

16. Measure for CF620

When receiving long size Fax, a CF620 error code may trigger. This has been corrected.

17. Changing the method of displaying/resetting the error code C6020 (abnormally high
fuser unit thermistor temperature)

The displaying and resetting of a C6020 error code (Abnormally high fuser unit thermistor
temperature) has been changed as illustrated below.

If a C6020 is detected, it will be displayed as a system error and can be reset by turning the
power OFF and then ON. (Up to two detections)

The third time when a C6020 is detected, it will be displayed as a service call as before. (Please
reset it in maintenance mode U163.)

The number of occurrence above will be reset (to “0”) when the main unit enters ready mode.

[Example]

18. Panel response enhancement

The panel response has been improved as illustrated below.

Copy screen: Entire screen


Send screen: All basic screens, Addressee tab, Some detail screens. Continuous operation of the
scroll one touch key for the address book.
Box screen: Mainly those frequently used functions such as all basic screens, Box
printing, Box transmission, Box saving, etc.

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes
19. Improving the panel operation

Optimized the internal processing

20. Measure for CF423/CF323

In rare cases, a CF423 or CF323 may occur when the data is sent to main unit after changing the
setting using Launcher software.

21. Measure for CFB2C

CFB2C may trigger due to various causes. This has been corrected.

22. Measure to prevent a lockup after changing the setting from the system menu

In rare cases, the CD icon may remain on the panel after changing the setting from the system menu.
This has been corrected.

23. Measure for an incorrect message when staple setting is made without setting originals

When the staple setting is made with the DF-710 (*1) or DF-750 installed, unless the original is set
and depending on the combination of settings, a "Cannot staple this size" message displays even if
the size combination of original and paper for copying/stapling is correct. This message is also
displayed during the copy operation and it is misguiding. A Modification has been carried out to
resolve the problem.

[The message will now display only when the original is set with non-operable combinations.

(*1) The message will not display with one point stapling on the DF-710.

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Previous Changes

The KM/CS-2560/3060 Combined Firmware 08/08 is upgraded

1. Measure for a JS-670 Detection Failure after recovering from sleep mode

Under the following conditions, the machine fails to detect the JS-670 after recovering from sleep
mode (it does not recognize the JS-670 is installed). This has been corrected.

2. Measure for a Panel Lockup when a copy is made with the original holder open

After copying with the original holder open, if you press the start key before the lamp goes back to
home position, the operation panel may lock up. This has been corrected.

Firmware Information
Type Program No. Check SUM Version Remarks
MAIN 2H0_2F00.011.006 ---------- 011.006
ENGINE 2H0_1000.010.004 ---------- 010.004 Updated
MMI2 2H0_7A00.011.006 ---------- 011.006 *1

Please upgrade all firmware to the latest version at the same time when upgrading firmware.

* 1 After updating the Firmware, the MMI2 Firmware Version will be displayed two ways depending upon
which Type Operation Panel PCB is installed in the MFP.

Operation Panel PCB MMI2 Version


Old Type 2H0_7000.011.006
New Type 2H0_7A00.011.006

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Fax Firmware
1. Measure for Resetting of Data on the Action List

When the firmware was upgraded to the last update Ver. 009.001, the data on the following list reset
to "0". This has been corrected.

Counter data on Action List


Error communication history on Error List
Data on Protocol List

2. Measure to prevent the original from outputting twice

When receiving multiple pages, the same page may output twice, adding one extra page in total.
This has been corrected.

(Example) When receiving two pages, the first page may output twice.
(Total output : 3)

Firmware Information
Type Program No. Check SUM Version Remarks
FAX APL ---------- ---------- 3KH_5100010002 Updated
FAX BOOT ---------- ---------- 3KH_5000009001
FAX BOOT/APL S3KH_5500010002 ---------- ---------- F/W provided Updated
MIX F/W

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Previous Changes
The Firmware is updated to 2.05A
Details of changes for Engine Ver 9.001
No Item Content
1 Measure for original detection If the machine is left idle for 2 to 3 hours, there may be a possibility
failure when setting the original when the original is set on the contact glass, the original is not detected
on the contact glass or an incorrect size is detected. This has been corrected.

Details of changes for FaxBoot/APL Ver 9.001


No Item Content
1 Measure to reduce Due to line conditions, the transmission speed to some destinations
communication errors to may slow down during V17 transmission, communicating in 4.8kbps
destinations (V27ter) or a transmission error may occur. Changes have been made
to compensate for the poor line conditions to reduce transmission
errors.

Firmware Information
Type Program No. VER. Remarks
MAIN 2H0_2F00.011.006 ---------- 011.006
ENGINE 2H0_1000.009.001 ---------- 009.001 Updated
MMI2 2H0_7A00. 011.006 ---------- 011.006 *1
Fax BOOT/APL 3KH_5500.009.001 ----------- 009.001 Updated

* 1 After updating the Firmware, the MMI2 Firmware Version 11.006 will be displayed two ways
depending upon which Type Operation Panel PCB is installed in the MFP.

Operation Panel PCB MMI2 Version


Old Type 2H0_7000.011.006
New Type 2H0_7A00.011.006

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Upgrading Firmware
MFP with New Type Operation Panel PCB

When upgrading Firmware to MAIN/MMI2 Ver. 11.006 (2.05A Combined Firmware) on an MFP with the
New Type Panel PWB installed, a Server Error message will display when the MAIN/MMI is Ver.10.029
or below. The MFP must be cycled OFF, wait at least five seconds, and then cycled ON again. The
Firmware upgrade will start and the Firmware will be upgraded successfully. A Compact Flash must be
used for this Upgrade. USB is not supported for this Update. Compact Flash or USB can be used
for subsequent updates from Version 11.006 and above.

If you try to downgrade Firmware below MAIN/MMI2 Ver. 10.029, on an MFP with a New Operation
Panel 2 PWB a CFB30 error will trigger. If this occurs, load MAIN/MMI2 Ver. 11.006 (2.05A Combined
Firmware or above) to recover from the error.

MFP with Old Type Operation Panel PCB

MAIN/MMI2 Firmware Ver. 11.006 (2.05A Combined Firmware or above) can be updated in the normal
manner. When updating firmware on an Old Type Panel PWB, firmware can be updated using Compact
Flash Card or USB for this update.

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Recovery Procedure if you lose Power during Firmware Update


If you lose power (Power failure, Main switch is turned OFF, etc.) during the Firmware Update Process
on an MFP with the new Panel 2 PWB, the Panel may not power up once the MFP regains power.
Follow the procedure below to restore the Panel so you can continue the Firmware Update.

1. Turn the Main Switch OFF and then unplug the Power Cord.
2. Remove CF or USB Memory Stick.
3. Remove the screw on the Operation Panel Lower Cover to remove the Cover.
Change the Switch on the Operation Panel PCB from "NORMAL" to "BOOT".
4. Plug in the Power Cord and then turn the Main Switch ON.
5. After the Memory Lamp lights, it will take approximately 1 minute to complete the reboot of
the old firmware to the Operation Panel PCB for restoration.
6. Turn the Main Switch OFF. Unplug the Power Cord.
7. Change the Switch on the Operation Panel PCB from "BOOT" to "NORMAL".
Reinstall the Operation Panel Lower Cover and secure it using the screw.
8. Insert the CF or USB memory stick containing the Firmware Update. Plug in the Power Cord
and turn the Main Switch ON to restart the Firmware update.

NORMAL BOOT

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Previous Changes (Combined Firmware not released with these changes)


Summery of changes

1. Support for change to the Operation Panel PWB.


2. Correction when the machine goes into sleep mode with the front cover open
3. Correction for a problem before memory overflow occurs
4. Correction for resetting multiple destinations
5. Correcting a problem when “<” character displays incorrectly.
6. Correction for a lockup problem when deleting the shortcut on the Document BOX screen
7. Correcting the FONT color when using BOX storage on the [Windows image and FAX viewer]
8. Correcting the problem of no. of FAX destinations on the Accessibility command
9. Correcting a display error after setting the Bypass
10. Correction for a lockup problem when removing/installing MK-2
11. Correction for a lockup problem when installing MK-2 and recovering from sleep mode
12. Correction for a problem where the Document BOX storage setting will not clear
13. Correction for [ON Hook] key on the SEND screen
14. Correcting a lockup problem when printing from the Document BOX
15. Measure for JAM05

Type Program No. Check SUM VER. Remarks


MAIN 2H0_2F00.011.006 ---------- 011.006 Updated
ENGINE 2H0_1000.008.002 ---------- 008.002
MMI2 2H0_7A00. 011.006 ---------- 011.006 *1 Updated

* 1 After updating the Firmware, the MMI2 Firmware Version 11.006 will be displayed two ways
depending opon which Type Operation Panel PCB is installed in the MFP.

Operation Panel PCB MMI2 Version


Old Type 2H0_7000.011.006
New Type 2H0_7A00.011.006

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Details of changes
No. Item Contents
1 Support for changing Please refer to the KM/CS-2560/3060 Technical Bulletin #3.
Operation Panel PWB

2 Correction when the If the machine enters the sleep mode with front cover open and then front cover is
machine goes into sleep closed after coming out sleep mode, the machine may lockup. This is corrected.
mode with the front cover
open
3 Correction for a problem During Scan to memory and before a memory overflow occurs, the display shows
before memory overflow Cancel and an Error Message displays at the same time. Copy or Send Functions or
occurs a Panel Lockup condition occurs. This has been corrected

4 Correction for resetting When sending a Fax to multiple destinations, the destinations will not be cleared on
multiple destinations the fax screen, once the screen is reset and the screen may lockup. This has been
corrected

5 Correcting a problem when When naming a custom media type the “<” character displayed garbled. Common
“<” character displays Setting - Original/Paper Setup - Media Type Setting - Media Type Name
incorrectly This has been corrected.
6 Correction for a lockup When you “Register a Shortcut” and “try to delete it under the Document BOX screen
problem when deleting the the display may lockup a show [Deleting]. This has been corrected.
shortcut on the Document
.
BOX screen
7 Correcting the FONT color Once open the detail screen of the JOB which is stored by the JOB BOX using KPDL
when using BOX storage mini Driver at [Windows image and FAX viewer], the FONT become white. This has
on the [Windows image been corrected.
and FAX viewer]
8 Correcting the problem of When you register the destination FAX number at the FAX TX on the Accessibility
no. of FAX destinations on Display, the number of destinations showing on the top right position of the screen
the Accessibility command shows “0”. This has been corrected.
9 Correcting a display error After selecting the bypass tray and you go back to “Quick Setup” tab, the cassette
after setting the Bypass shows “Tray 1”. This has been corrected.
[Orig./Paper/Finishing] tab ( [Paper Selection] (MP Tray Setting ( Size Entry.)
10 Correction for a lockup If you remove/install MK-2 card during when the disc icon on the login screen is
problem when displayed, the panel may lockup. This has been corrected.
removing/installing MK-2
11 Correction for a lockup With the MK-2 is installed, if the sleep key ON/OFF t is pressed to recover from sleep
problem when installing mode right after switching to the different screen from the default screen or to the
MK-2 and recovering from main menu, the disc icon may never stop turning and a lockup condition occurs. This
sleep mode has been corrected.
12 Correction for a problem After storing setting for the new Document BOX s, the previous setting still remains.
where the Document BOX This has been corrected.
storage setting will not
clear

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

No. Item Contents


13 Correction for [ON Hook] If you register or delete the shortcut key at the Send screen, the [ON Hook] key might
key on the SEND screen turn to gray. This has been corrected.
14 Correcting a lockup When printing from the Document Box and you press the [Paper Selection] button at
problem when printing from the screen does not open and the panel may lockup. This has been corrected.
the Document BOX
15 Measure for JAM05 When outputting JOB’s to the printer and the output of Job’s sent to print increase, a
JAM05 may trigger. This has been corrected.

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Previous Changes
The KM/CS-2560/3060 Combined Firmware 03/08A

Details of Changes

1. Change to C6000 error code detection conditions (Fuser heater problem)

If the power source voltage decreases (less than 90% of rated voltage) and the MFP is in a low
temperature environment (10ºC or less during the warm-up operation), a C6000 error code may
trigger. As a preventative measure, the detection conditions are changed.

(Specification: Power source --- Rated voltage ± 10%, Temperature --- 10ºC ~ 32.5ºC)

Error Triggers [Before Change]

During the warm-up/stand-by mode: When the center fixing temperature is equal or drops below
70ºC and remains for 10 seconds.

During the warm-up/stand-by mode: When the edge fixing temperature is equal or drops below
40ºC and remains for 10 seconds.

Error Triggers [After Change]

During the warm-up/stand-by mode: When the center fixing temperature is equal or drops below
70ºC and remains for 14 seconds.

During the warm-up/stand-by mode: When edge fixing temperature is equal or drops below 50ºC
and remains for 14 seconds.

The conditions during the warm-up mode continue for 140 seconds or more.
.

2. Measure for drive failure after continuous job printing is completed

After performing multiple print jobs using the DF-670 as one of the eject destinations and if the final
job eject destination is different, the main unit drive will stop but the finisher will continue. This has
been corrected.

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

3. Measure for a JAM after cancelling a job while printing in duplex mode

While performing multiple print jobs with different eject destinations, if you cancel a print job in duplex
mode between the jobs when the eject destination changes, the paper in the duplex unit may remain.
As a result, a paper jam occurs. This has been corrected.

4. Disabling U161 (READY DISP TIME)

The setting for U161 has been disabled.

5. Measure for a CF620 code that may trigger when API data is executed
MAIN

After API data is executed/printed and then various operations are carried out, a CF620 code may
trigger. This has been corrected.

One example is as follows. A CF-620 code triggers if the status page is printed multiple times from
the operation panel.

Firmware Information
Type Program No. Check SUM Version Remarks
MAIN 2H0_2F00.006.002 --------- 006.002 - UPDATED
ENGINE 2H0_1000.008.002 ---------- 008.002 - UPDATED
MMI 2H0_7000.006.001 ---------- 006.001 UPDATED

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes
Previous Changes
Summary of changes

1. Measure for C6020 when opening and closing the cover.


2. Correcting detection error on Job Separator when recovering from sleep mode.
3. Correcting the movement of bypass lift plate during the installation of toner.
4. Correction for recovering from sleep mode
5. Measure for malfunction at auto sleep mode
6. Measure for CF620 at address book list output
7. Correction for print overrun at panel reset
9. Correction for panel lock on the send screen.

Firmware Information
Type Program No. Check VER. Remarks
SUM
MAIN 2H0_2F00.005.003 ---------- 005.003 Å Upgraded
ENGINE 2H0_1000.007.002 ---------- 007.002 Å Upgraded
MMI 2H0_7000.005.001 ---------- 005.001 Å Upgraded
When upgrading firmware or replacing board etc., please upgrade each firmware (MAIN, ENGINE, MMI) to the
latest version at the same time.

Details of Changes
No Item Contents
1 Measure for C6020 when After turning ON the power switch, when recovering from sleep mode or when the
opening and closing the cover is opened and closed, a C6020 (abnormally high fixing unit temperature) is
cover. detected within 20 sec. when the machine starts to warm-up and comes to ready.

This is caused when the main heater does not turn off. This has been corrected.)

2 Correcting of detection error When recovering from sleep mode, the message "Job Separator is not connected"
of Job Separator when may display even if it is connected. This has been corrected.
recovering from sleep mode.
3 Correcting the movement of The Bypass lift plate keeps going up and down during the auto installation of toner
bypass lift plate during the when the power switch is turned ON for the first time during installation. (Normally, it
installation of toner. goes up and down only once.) This has been corrected.
4 Correction for recovering from When the machine wakes up from the sleep mode from a network pooling
sleep mode signal, the engine drives even if the LCD panel is OFF.) This has been
corrected.

5 Measure for malfunction at When pressing the start key at the same time when the machine goes into sleep
auto sleep mode mode, “Wait for a while” may remain displayed. This has been corrected.
6 Measure for CF620 at address When you output the list for the address book, CF620 may occur. This has been
book list output corrected.
7 Correction for print overrun at When pressing the start key after pressing the reset key or entering auto panel reset,
panel reset “Print Overrun” occurs. Now, it's been corrected.
8 Correction for panel lock on The panel may lock during certain operations in the send menu. This has been
the send screen corrected.

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Previous Changes
The KM/CS-2560/3060 Firmware package is upgraded to 01/30/08
Summary of changes

1. Measure for malfunction for auto sleep


2. Measure for CF26F
3. Change of Command Center
5. Change of name of option printed on the status page
6. Correction at PG output
7. Measure for CF445 in auto sleep
8. Measure for not shifting into sleep mode
9. Correction at continuing operation from energy save key to power key
10. Measure for lock during continuous JOB reception
11. Measure for not feeding from correct cassette slot in a certain application
12. Measure at Network authentication
14. Measure for no FAX communication
15. Making a void for SIOP0 command
16. Measure for panel lock after recovering from sleep mode
17. Correction for operation panel lock
18. Preventing a faint image at leading edge during bypass feeding

Firmware Information
Type Program No. Check SUM VER. Remarks
MAIN 2H0_2F00.004.005 ---------- 004.005 Å Upgraded
ENGINE 2H0_1000.006.001 ---------- 006.001 Å Upgraded
MMI 2H0_7000.004.006 ---------- 004.006 Å Upgraded
When upgrading firmware or replacing board etc., please upgrade each firmware (MAIN, ENGINE,MMI) to the latest version at
the same time.

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Details of changes
No Item Content
1 Measure for malfunction When the start key is pressed while shifting into auto sleep, the machine keeps showing
for auto sleep “Wait for a While”. This is corrected.
2 Measure for CF26F Correction is made since CF26F occurs immediately after continuous chain JAM.
3 Change of Command
Applicable to option language at Command Center
Center
4 Change of name of option [Security Kit] ⇒ [Data Security Kit (C)]
printed on the status page In order to obtain ISO15408, it is necessary to print out the name of option as an
application.
5 Correction at PG output After PG output by U089 (MIP-PG output), C0630 error (DMA abnormal) might occur. This
is corrected.
6 Measure for CF445 at When drum heater turns ON, CF445 might occur when the start key is pressed while
auto sleep shifting into auto sleep. This is corrected.
7 Measure for not shifting The correction is made so the machine shifts into the sleep mode even after
into sleep mode passing the set time.
8 Correction at continuing When importing the address book data by KM-NET VIEWR, if the power save key is
operation from energy pressed and then the power key continuously back and forth, the panel may lock or a
save key to power key CF630 may occur. This is corrected.
9 Measure for lock during When approx 1200pages print out continuously from as 1 Job, the printing speed will
continuous JOB reception decrease and eventually the print JOB locks. When the lock is cancelled, a CF000 occurs.
This is corrected.
10 Measure for not feeding The paper feeding is not possible with the correct cassette at duplex mixed data with
from correct cassette slot different output sizes (example Letter – R/Legal) using the certain application. This is
with a certain application corrected
11 Measure at Network The correction is made for Private Print (Job Retention function). It may not be available to
authentication use at Network authentication.
12 Measure for no FAX Reception is not possible since FAX transmission JOB keeps on processing. (Copy/Print
communication out put is possible). This is corrected
13 A void is made for SIOP0
-------------------------------
command
14 Measure for panel lock The correction is made since the CD icon keeps displaying and the panel lock condition
after recovering from sleep occurs after recovering from sleep. (The auto clear process is not properly performed and
mode the CD icon is incorrectly displayed.)
15 Correction for operation The correction is made since JOB cancel button can be pressed even if the operation
panel lock panel lock is set to ON in the Command Center.
16 Preventing a faint image at At bypass feeding, the 4.5mm becomes a faint since the transfer ON timing at bypass
leading edge during feeding is delayed. This is corrected so Transfer ON timing is set same as a cassette)
bypass feeding

Kyocera Mita Corporation


KM/CS-2560/3060 Firmware Release Notes

Previous Changes

Details of changes
Item Contents
1 Support for sleep mode During the low power mode, with FAX timer TX set, FAX poling TX, network FAX TX job,
the machine does not go into the sleep mode after the job is finished. This is corrected.
2 Support for FRPO When setting the FRPO command D6 [Set Jam Retry Timing] to 01 (set Jam Retry
command D6 [Set Jam Timing at the timing of reaching fuser section), if a double feed Jam occurs, the
Retry Timing] machine will be waiting to eject the paper and drive does not stop. This is corrected.
(The default setting for FRPO command D6 is 03: Jam Retry Timing is set at completing
output)
3 Support for A5 When A5 (lateral)/LETTER (lateral) is set on the bypass with paper size auto detection
(lateral)/LETTER set, as A5 (lateral)/LETTER (lateral) is out of specification and they are detected as
(lateral) when setting A4R/LETTER R.
them on the bypass This is corrected.

4 Corrected the operation Main Motor (MM) and Feeding Motor (PFM) drive starts by [MOTOR ON] in U032
for [MOTOR ON] in the [Check Clutch Operation]. However, it turns OFF at 1 sec. This will now operate
U032 [Check Clutch correctly.
Operation]
5 Improving white spots Because of the gap between charge and discharge (cleaning), there may be the
at the leading edge possibility to skip the image laterally at the leading edge of a gray image. The charge
section with gray image timing is corrected.
[Change] After 200ms from cleaning lamp ON, the charge will be ON Æ after 100ms
from cleaning lamp ON, the charge will be ON.
6 Review transfer timing Currently transfer ON timing does not have any tolerance (close to the leading edge of
ON only the paper).
[Change] The transfer ON timing is delayed for about 10msec.

Firmware Information

Type Program No. Check SUM VER. Remarks


MAIN 2H0_2F00.003.001 ---------- 003.001 Upgraded
ENGINE 2H0_1000.005.002 ---------- 005.002 Upgraded
MMI 2H0_7000.002.022 ---------- 002.022
When upgrading firmware or replacing board etc., please upgrade firmware to the latest version posted on
KMAconnect.

Kyocera Mita Corporation

You might also like