PROPOSED FIVE STORY WITH ROOF DECK

20-UNITS DORMITORY BUILDING

LOCATION:
PULONGBUHANGIN, STA MARIA,
BULACAN

GROUP MEMBERS:

CHAVEZ, PATRICIA ANN Y.


ESPIRITU, CHARLENE M.
GALLARDO, HARLENE V.
TABLE OF CONTENTS
I.
I. INTRODUCTION
STRUCTURAL
DESIGN
CRITERIA
I. DESIGN LOAD CRITERIA
A. DEAD LOAD
CONCRETE 23.56 Kn/m3
STEEL 76.93 Kn/m3
150 mm THK. CHB WALL 2.73 kPa
100 mm THK. CHB WALL 2.11 kPa

B. LIVE LOAD
ROOF 1.00 kPa
CLASSROOMS 1.90 kPa
TOILETS 2.40 kPa
CORRIDORS ABOVE STAIRS 3.80 kPa
CORRIDORS ON GROUND 4.80 kPa

C. WIND LOAD (NSCP 2010)


BASIC WIND VELOCITY, V = 250 KPH
P = qh [(GCpf)-(Gcpi)] (DESIGN WIND PRESSURE)
WHERE: qh = VELOCITY PRESSURE, kPa
GCpf = EXTERNAL PRESSURE COEFFICIENT
Gcpi = INTERNAL PRESSURE COEFFICIENT

D. SEISMIC LOAD (NSCP 2010)


Cvt
V= W (DESIGN BASE SHEAR)
RT

V max = ❑ W V ❑=0.11CvW V ❑= ❑ W
❑ ❑
WHERE W = TOTAL DEAD LOAD
T = NATURAL PERIOD = Cv(Fb)0.5
WHERE C = NUMERICAL COEFFICIENT, Ct = 0.0853 (for steel
moment resisting frames) = 0.0731 (for reinforced concrete moment resisting frames) = 0.0488
(for all other buildings)
h = BUILDING HEIGHT