WBC
HumaCount 5L
BAS%
5-Part WBC Differential System
BAS
EOS%
EOS
NEU%
NEU
MON%
Movie Case Study Book
MON
LYM%
Walk-away
Capability
LYM
RBC
MCHC RDWcv RDWsd
HumaCount 5L REF
5-Part-Laser Technology 16430
MCH
(LYM%, MON%, NEU%, BAS%, EOS%)
> Patient ID mapping via barcode reader
> RBC, MCV, MCH, MCHC HGB, HCT, RDWc, PLT,
MPV, PDWc, PCT, RDWsd, PDWsd, P-LCC, P-LCR > Built-in mixer with cap piercer
MCV
> Flag for immature granulocytes and large blasts Small Sample Module 16430/12
HCT
> 60 samples/hour HumaRoll (tube roller) 15460
> Built-in QC software > Burn away of proteins at each measurement cycle
> Open and closed tube sampling > Steady workflow with reliable cell counting
Sample volume Closed- and Open-mode: 110μl Reagents HC5L-Diluent (20 liter)
Optional small sample module: 25 μl HC5L-Lyse (5 liter)
Sample type Human whole blood (K3-EDTA anticoagulant) HC5L-Diff (1 liter)
Tube identification By means of the front panel keyboard Sheath fluid Diluent
(enter ID) Quality control 16- and 64-day Levey-Jennings charts,
By means of the barcode labels separate QC database (6 level)
(manual and/or auto-sampler) Flagging Morphological flags
Sampling method Ceramic shear valve Interpretive flags (Diagnostic flags)
with 3 separated primary loops Lab limits (normal ranges)
Measured Reagents alert Pre-alert-online reagent replacement
parameters CBC+5DIFF mode (26 parameters): System alert Instrument alerts, self check
WBC, LYM, MON, NEU, EOS, BAS, LYM%, MON%, Calibration Manual and SW supported automatic mode
NEU%, EOS%, PLT, PCT, MPV, PDW, BAS%, RBC, Languages available UK-English, US-English, Hungarian, German,
HCT, MCV, HGB, MCH, MCHC, RWDcv, RDWsd, Italian, Polish, Russian, Spanish, Turkish, French
PDWcv, PDWsd, P-LCC, P-LCR Software upgrade Via USB
Throughput 60 tests/hour Data storage
Measurement capacity 100,000 records including flags,
method Volumetric impedance change for WBC, RBC, PLT scatter- and histograms
Spectrophotometry for HGB Data processing VIA C7 1.8GHz processor
Light scattering 4-diff measurement: Data store Embedded XP
LYM, MON, NEU, EOS Display 800 x 600 color graphic LCD, portrait layout
Light scattering BASO measurement External printing Via USB port, any Windows® compatible
Aperture diameter WBC: 80 μm printer
RBC, PLT: 70 μm External keyboard Via PS/2 or USB
HGB measurement Light source: green LED with 540nm wavelength Barcode reader Optional manual barcode reader via USB
Detector: light to frequency converter Built-in barcode reader in the auto sampler
Optical Peripheral ports USB (2.0) 4pc., Ethernet, PS/2
measurement Light source: semiconductor laser diode with Power requirements 110/230VAC; 47 Hz to 63 Hz
650nm wavelength and 10mW Power consumption Maximum 400VA
(Class IIIB laser module) Main fuse F 10A H 250V
Quartz flow cell with hydro-dynamic focusing Operating conditions 15 – 30°C (59 – 98 °F);
981643/2017-01 © 2017 Human
Detector: fiber optic coupled PIN Si photodiodes Maximum relative humidity 80%
Internal safety interlock Weight Instrument 35 kg, auto-sampler 10 kg
Size (h x d x w) Instrument 540 x 460 x 450 mm
Auto-sampler 180 x 270 x 320 mm