S. & A.S.

LTD
CABIN CONTROL BOARD
VERSION 1.0
REF. CARTOP V1.0

USER’S MANUAL
FOR S/W VERSION 1.00
1510

S. & A. S. LTD
Beirut Office: Headquarters & Factory: Website:
Boutros Building 1st Basement S. & A. S. Building www.sascontrollers.com
Cheikh-el-Ghabi Street Seaside Road
Ghabi Beirut 2068 7808 Jieh Chouf
Lebanon Lebanon Technical Support & Email: 1
Tel: +961 1 216 994 Tel: +961 7 996 333 Tel: +961 71 996 333
Fax:+961 1 339 600 Fax:+961 7 996 116 support@sascontrollers.com
1  GENERAL DESCRIPTION 3 
  MAIN FEATURES 3 
3  TECHNICAL DATA 3 
4  TERMINAL DESCRIPTION 4 

4.1  TERMINAL LAYOUT ................................................................................................................................................ 4 


4.2  CARTOP TERMINALS ............................................................................................................................................. 5 
4.3  INPUT TERMINALS ................................................................................................................................................. 5 
4.4  OUTPUT TERMINALS ............................................................................................................................................. 6 
4.4.1  OUTPUT TERMINALS ...................................................................................................................................... 6 
4.4.2  INDICATOR OUTPUT TERMINALS ................................................................................................................. 6 
4.5  CALL TERMINALS ................................................................................................................................................... 6 
4.6  COMMUNICATION TERMINALS CONNECTION ................................................................................................... 6 
5  DESKTOP FIRMWARE UPGRADE 7 

5.1  INSTALLING THE CARTOP FIRMWARE UPGRADE SOFTWARE ....................................................................... 7 


5.2  INSTALLING THE CARTOP USB DRIVER ............................................................................................................. 7 
5.2.1  DRIVER SETUP FOR WINDOWS VISTA/WIN7 .............................................................................................. 7 
5.2.2  DRIVER SETUP FOR WINDOWS XP .............................................................................................................. 9 
5.3  FIRMWARE UPGRADE PROCESS ...................................................................................................................... 10 
6  GOOGLE STORE FIRMWARE UPGRADE 12 

6.1  INSTALLING THE SASPTOOL FIRMWARE APPLICATION ON THE MOBILE .................................................. 12 
6.2  FIRMWARE UPGRADE PROCESS ...................................................................................................................... 12 
7  APPENDIX A 14 

2
1 GENERAL DESCRIPTION
The CarTop is used with the new CAN communication interface available in the Microzed V3.5 boards. The main aim of
this interface is to simplify the elevator installation procedure and reduce the number of wires needed. Using the
CarTop, the Microzed V3.5 board receives information from the cabin and sends control signals back. Installed on the
cabin, the CarTop is used to register carcalls, process the control signals sent by the main Microzed board, read
different car information (calls,door status…) and send them back to the main Microzed board.

2 MAIN FEATURES
Platform ARM Microcontroller
Communication CAN Open communication interface via CAN bus
Firmware update User desktop interface to upgrade firmware on site
Google store Application: SASPTool

3 TECHNICAL DATA
Supply voltages Board supply: 24vdc +15% -25% - 120mA
Periphery supply: 22vdc +15% -25%
Inputs Each input has a led to indicate its status – all inputs are optically isolated
Input active voltage level is 22vdc
Control outputs Each output has a led to indicate its status – all outputs are dry relay contacts
Rated at 250Vac 10A1
Spare outputs Each output has a led to indicate its status – all outputs are optically isolated
Output voltage level is 0vdc (GND) when active
Call terminals Each call has a led to indicate its status
Each call terminal consists of a combined input/output which is optically isolated
Call active voltage level is zero volts (GND)
Call terminals are capable of driving lamps up to 3 watts operating on 22vdc
Each call terminal is protected by an additional output transistor
Indicator outputs Each output has a led to indicate its status – all outputs are optically isolated
For A,B,C,D,E, LED On: Output voltage level is 22vdc (P)
For arrow up and arrow down LED On: Output voltage level is 22vdc (P)
Connection Screw type, plug-in connectors

1
Care should be taken to add a freewheeling diode in parallel with the coil of each DC contactor or DC relay driven from the board.
3
4 TERMINAL DESCRIPTION
4.1 TERMINAL LAYOUT

CDOOR
CSOP1
CLGT
LGHT

SOP1

CLSE

GND
OPN
P
CM ↑
D2 ↓
D1 E
D
P-CAN C
GND_CAN B
L1 A
H1 HALL-
L2 HALL+
H2 CAR-
CAR+
DZ SOP4
RE OPN SOP3
CLSE SOP2
LSEO
LSEC
INSP UP
INSP DN
INSP EN
RSV
FULL
OVLD
STP
SPI1
SPI2
CT14
CT10
CT11
CT12
CT13

CT15
CT6

CT8
CT9
CT0
CT1
CT2
CT3
CT4
CT5

CT7

4
4.2 CARTOP TERMINALS
P Supply – positive side 22Vdc
GND Supply – negative side

4.3 INPUT TERMINALS


1
DZ Door zone magnetic switch
RE OPN Re-open for automatic door (when inactive) / door closed for swinging door (when active)
CLSE Bypasses reclosing delay in automatic door
LS EO Limit switch end of opening
LS EC Limit switch end of closing
INSP UP Inspection up
INSP DN Inspection down
2
INSP EN Inspection enable (when input is inactive)
RSV Reservation – outside calls are canceled (when input is active)
FULL Full load – only car calls are served with outside calls still being registered (when input is active)
OVLD Overload
2
STP Emergency stop (when input is inactive)
SPI1 Spare Input1
SPI2 Spare Input2

To deactivate emergency stop, both STP inputs on CartTop control and on Microzed main control should be active.

In case RE OPN input is configured as normally closed, both RE OPN inputs on CartTop control and on Microzed main
control should be active to deactivate re-open. Otherwise (i.e. RE OPN is configured as normally open), re-open is
considered active when one of its corresponding inputs on the Microzed main control or the CartTop control is active.

To enable normal operation, both INSP-EN inputs on CartTop control and on Microzed main control should be active.

All the other inputs are considered active when one of their corresponding inputs on the Microzed main control or the
CartTop control is active.

1
This terminal must be connected to DZ of Microzed in main control panel as well.
2
In case this terminal is not used on Microzed main control panel, please connect it to “P”.

5
4.4 OUTPUT TERMINALS
4.4.1 OUTPUT TERMINALS
CLSE Cam contactor1 / Close relay or contactor2
OPN Open door relay or contactor2
CDOOR Common for CLSE and OPN outputs
SOP1 Spare output 1
CSOP1 Common for Spare output 1
LGHT Car light relay
CLGT Common for LGHT output

4.4.2 INDICATOR OUTPUT TERMINALS


↑ Up direction arrow
↓ Down direction arrow
A Floor information A for Gray code indicator
B Floor information B for Gray code indicator
C Floor information C for Gray code indicator
D Floor information D for Gray code indicator
E Floor information E for Gray code indicator

4.5 CALL TERMINALS


CT15 Car 15
CT14 Car 14
CT13 Car 13
CT12 Car 12
CT11 Car 11
CT10 Car 10
CT9 Car 9
CT8 Car 8
CT7 Car 7
CT6 Car 6
CT5 Car 5
CT4 Car 4
CT3 Car 3
CT2 Car 2
CT1 Car 1
CT0 Car 0

4.6 COMMUNICATION TERMINALS CONNECTION


P-CAN CAN Supply – positive side 24Vdc (Taken from separate supply installed in Microzed panel)
GND_CAN CAN Supply – negative side
L1 CAN Low
H1 CAN High
L2 Not used
H2 Not used

1
For swinging door.
2
For automatic door only.
6
5 DESKTOP FIRMWARE UPGRADE
5.1 INSTALLING THE CARTOP FIRMWARE UPGRADE SOFTWARE
In order to upgrade firmware on site, a CD will be provided by S.&A.S.Ltd & the below steps shall be followed:
1. Run file “SAS_Patch.exe” located in “CarTop_PTool\SAS_PTool” folder.
2. Go to the folder “SAS_PTool_Setup” located in “MZ350_PTool\SAS_PTool” folder and double click on
“setup.exe”, then follow the instructions to setup the software “SAS_PTool.exe”.
3. “SAS_PTool” will appear in the programs list. Send it to Desktop as shortcut.

5.2 INSTALLING THE CARTOP USB DRIVER


1. Power off the CarTop board.
2. Make sure that USB cable is connected to PC. Plug in the USB cable and Power on the CarTop.
3. Follow the steps below to setup the driver according to the version of windows on PC.

5.2.1 DRIVER SETUP FOR WINDOWS VISTA/WIN71


The first CarTop plugged into the PC USB port may not launch an automatic start. In this case, right-click my computer
and choose properties. The following window appears. On the left side of the window, click on Device Manager.

1
This will be implemented only one time when the first CarTop is connected to PC through USB.
7
The CarTop device will appear in Other Devices, right-click it and choose Update Driver Software.

Select “Search automatically for updates driver software”.

8
Select “Install this driver software anyway”.

The Driver SETUP procedure will be done only once For Windows vista/Win7.
So, the driver of any new CarTop connected to the PC USB port will be installed automatically.

5.2.2 DRIVER SETUP FOR WINDOWS XP

Each time a new CarTop is plugged into the PC USB port, a “Found New Hardware Wizard” window appears.
Select “Install the software automatically (Recommended)” and click next.

Select “Continue Anyway”.


9
The driver of the new CarTop connected to the PC USB port will be installed automatically.

5.3 FIRMWARE UPGRADE PROCESS


Power off the CarTop board.
Make sure that USB cable is connected to PC. Plug in the USB cable and Power on the CarTop.
Run “SAS_PTool” application.
The following window will appear prompting the user that the CarTop board is detected on the USB port:

10
Click Open to choose the *.sas file that will be used to upgrade the firmware.
A Footnote will appear showing the file name, the software version and its date:

Click upgrade. The upgrade progress is shown as below:

Once the upgrade is complete, the footnote “Firmware upgraded successfully” will appear:

Disconnect the USB cable from CarTop


The user can now process with normal operation of the lift.

11
6 GOOGLE STORE FIRMWARE UPGRADE
6.1 INSTALLING THE SASPTOOL FIRMWARE APPLICATION ON THE MOBILE
In order to upgrade firmware from a mobile, follow the below steps:
1. Search for the application “SASPTool” on google store and install it, or follow the link below: 
https://play.google.com/store/search?q=SASPTool.      

6.2 FIRMWARE UPGRADE PROCESS


Run “SAS_PTool” application from the mobile.
The below window appears showing all *.sas files already saved.

Power off the CarTop board.


Use a USB cable to connect board to the mobile.
Turn CarTop on.

12
Click on the sas file that you need to download.
A Popup window will appear showing the file name, its description and its date:

Click Yes. The downloading starts:

13
Once the downloading is complete, the message “Firmware Downloaded successfully” will appear:

Disconnect the USB cable.


The user can now process with normal operation of the lift.

If you desire to delete any sas file from the mobile list, press on the filename until a Popup window appears showing you
multiple choices:

7 APPENDIX A
This appendix contains all wiring diagrams relevant to assembling the board in a panel.

14
1 2 3 4 5 6

D D

SUPPLY & OUTPUTS INPUTS DOOR INFO CALLS


CARTOP_SUPPLY.Sch CARTOP_INPUTS.Sch CARTOP_DOOR.Sch CARTOP_CALLS.Sch

C C

CARTOP WIRINGS
B B

S. & A.S. Ltd.


BOUTROS BLDG, 1ST BSMT
CHEIKH-EL-GHABY ST.
2068 7808 GHABY - BEIRUT

CARTOP WIRING DIAG

A A

Size FCSM No. DWG No. Rev


B CARTOP-WirDiag.Sch 1

Scale Sheet
1 of 1

1 2 3 4 5 6
1 2 3 4 5 6

1. 220 LINE
2. NEUTRAL
D 3. S1 D
Speed governer
4. S2
Car Door contact
5. S3
Spare (Door step microswitch,
Inspection Box Emergency
stop button) 6. S4

7. SPARE (or 60VDC)


Traveling Cable
8. GND
9. P
10. PP
11. INSP-EN
P P P SOP4
12. INSP-UP
P GND
13. INSP-DN
C GND GND C
14. DZ
DIGITAL INDICATOR
15. EOS-UP (1) (1)

2
P GND (+24V) (-24V) OR DECODER
16. EOS-DN
17. EOSI-UP
18. EOSI-DN LINE

10

10

10
MicroZed v3.5
19. SPARE CAN

20. SPARE
CAR LIGHT
21. +24Vdc (2) (2) (2) (2)
P_CAN GND_CAN L1 H1 CLGT LGHT CSOP1 SOP1 SOP2 SOP3 SOP4
22. -24Vdc P GND
CAB BUS E D C B A
+22V (-) +24V (-24V) UP DN
23. CAN H ARROW ARROW
24. CAN L

B MZ-CARTOP B

S. & A.S. Ltd.


Note: BOUTROS BLDG, 1ST BSMT
CHEIKH-EL-GHABY ST.
(1): Taken from separate supply installed 2068 7808 GHABY - BEIRUT
in MicroZed Panel
CARTOP V1.0 WIRING DIAG:SUPPLY & OUTPUTS
(2): Spare outputs- functions assigned from
MicroZed Menu
A A

Size FCSM No. DWG No. Rev


B CARTOP_SUPPLY.Sch 1

Scale Sheet
1 of 4

1 2 3 4 5 6
1 2 3 4 5 6

D D

ON=RESERVE CAR
OFF=INSPECTION

FULL LOAD SWITCH

OVERLOAD SWITCH

SPARE INPUT1 SWITCH

SPARE INPUT2 SWITCH


(REVISION) ON=NORMAL

STP
C C

INSP INSP INSP RSV FULL OVLD STP SPI1 SPI2


UP DN EN

MZ-CARTOP
B B

S. & A.S. Ltd.


BOUTROS BLDG, 1ST BSMT
CHEIKH-EL-GHABY ST.
2068 7808 GHABY - BEIRUT

CARTOP WIRING DIAG: INPUTS

A A

Size FCSM No. DWG No. Rev


B CARTOP_INPUTS.Sch 1

Scale Sheet
2 of 4

1 2 3 4 5 6
1 2 3 4 5 6

LAST STOP

D D

SWINGING DOOR AUTOMATIC DOOR

P P3 (60Vdc taken from MicroZed Panel) P

20CM

CLOSE WITHOUT DELAY

END OF CLOSING
END OF OPENING
DOOR JAM
SWITCH
C C

PHOTOCELL
CAM
D.C. DOOR DRIVE
FIRST STOP

PP(*)
COM OPN CLSE

REOPEN
GND

To MicroZed Board

B B
RE CLSE CDOOR DZ(1) RE CLSE LS LS CDOOR OPN CLSE
OPN OPN EO EC

MZ-CARTOP

S.& A.S. Ltd.


Note: BOUTROS BLDG, 1ST BSMT
CHEIKH-EL-GHABY ST.
(1): DZ is recomended for automatic door. 2068 7808 GHABY - BEIRUT - LEBANON
(*): "PP" only for magnetic switches
CARTOP WIRING DIAG: DOOR INFO

A A

Size FCSM No. DWG No. Rev


B CARTOP_DOOR.Sch 1

Scale Sheet
3 of 4

1 2 3 4 5 6
1 2 3 4 5 6

CAR CALLS
D P D

15 15
14 14
13 13
12 12
11 11
10 10
9 9
8 8
7 7
6 6

C 5 5 C
4 4
3 3
2 2
1 1
0 0

GND
_ _
+ +
CT CT CT CT CT CT CT CT CT CT CT CT CT CT CT CT HALL CAR
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

MZ-CARTOP
B B

S.& A.S. Ltd.


BOUTROS BLDG, 1ST BSMT
CHEIKH-EL-GHABY ST.
2068 7808 GHABY - BEIRUT - LEBANON

MICROZED V3.4 WIRING DIAG: CALLS

A A

Size FCSM No. DWG No. Rev


B CARTOP_CALLS.Sch 1

Scale Sheet
4 of 4

1 2 3 4 5 6