PW = 6 x 100w = 600w
PKW = 600w/1000 = 0.6 kw
PKVA = 0.6 kw/1 = 0.6 kva
I = P/V= 600w/120v = 5 amp.
PW = 8 x 100w = 800w
PKW = 800w/1000 = 0.8 kw
PKVA = 0.8kw/1 = 0.8 kva
I = P/V = 800w/120v = 6.67 amp.
PW = 5 x 150w = 750w
PKW = 750w/1000 = 0.75 kw
PKVA = 0.75kw/0.8 = 1.5 kva
I = 750w/120v = 6.25 amp.
PW = 6 x 150w = 900w
PKW = 900w/1000 = 0.9 kw
PKVA = 0.9kw/0.8 = 1.13 kva
I = 900w/120v = 7.5 amp.
Circuito # 6 (1 microondas (1500w) a 120v)
PW = 1500w
PKW = 1500w/1000 = 1.5 kw
PKVA = 1.5kw/1 = 1.5 kva
I = 1500w/120v = 12.5 amp.
PW = 1000w
PKW = 1000w/1000 = 1 kw
PKVA = 1kw/0.8 = 1.25 kva
I = 1000w/120v = 8.33 Amp.
PW = 600w
PKW = 600w/1000 = 0.6 kw
PKVA = 0.6kw/0.8 = 0.75 kva
I = P/V = 600w/120v = 5 amp.
PW = 1000w
PKW = 1000w/1000w = 1.0 kw
PKVA = 1.0kw/0.8 = 1.3 kva
I = P/V = 1000w/240v = 4.167 amp.
PW = 1500w
PKW = 1500w/1000 = 1.5 kw
PKVA = 1.5kw/1 = 1.5 kva
I = P/V = 1500w/120v = 12.5 amp.
PW = 650w
PKW = 650w/1000 = 0.65 kw
PKVA = 0.65kw/0.8 = 0.8125 kva
I = P/V = 650w/120v = 5.42 amp.
PW = 2 x 150w = 300w
PKW = 300w/1000 = 0.3 kw
PKVA = 0.3kw/0.8 = 0.375 kva
I = P/V = 300w/240 = 1.25 amp.
PW = 75w
PKW = 75w/1000 = 0.075 KW
PKVA = 0.075kw/0.8 = 0.094 kva
I = P/V = 75/120V = 0.62 amp
PW = 3000w
PKW = 3000w/1000 = 3 kw
PKVA = 3w/0.8 = 3.75 kva
I = 3000w/120v = 25 amp.
TOTAL DE POTENCIA Y AMPERAJE
PW = 8 x 100w = 800w
PKW = 800w/1000 = 0.8 kw
PKVA = 0.8 kw/1 = 0.8 kva
I = P/V= 800w/120v = 6.67 amp.
PW = 7 x 150w = 1050w
PKW = 1050w/1000 = 1.05 kw
PKVA = 1.05kw/0.8 = 1.3125 kva
I = 1050w/120v = 8.8 amp.
d) 8 T.C a 120v (circ. # 8)
PW = 8 x 150w = 1200w
PKW = 1200w/1000 = 1.2 kw
PKVA = 1.2kw/0.8 = 1.5 kva
I = 1200w/120v = 10 amp.
PW = 1000w
PKW = 1000w/1000 = 1 kw
PKVA = 1kw/0.8 = 1.25 kva
I = 1000w/120v = 8.33 Amp.
PW = 1200w
PKW = 1200w/1000 = 1.2 kw
PKVA = 1.2kw/0.8 = 1.5 kva
I = P/V = 1200w/240v = 5 amp.
PW = 2 x 150w = 300w
PKW = 300w/1000 = 0.3 kw
PKVA = 0.3kw/0.8 = 0.375 kva
I = P/V = 300w/240 = 1.25 amp.
PW = 2 x 150w = 300w
PKW = 300w/1000 = 0.3 kw
PKVA = 0.3kw/0.8 = 0.375 kva
I = P/V = 300w/240 = 1.25 amp.
PW = 2100w
PKW = 2100w/1000 = 2.1 kw
PKVA = 2.1kw/1 = 2.1 kva
I = P/V = 2100w/240v = 8.75 amp.
1.7m + 2.0m + 2.70m + 0.5m + 1.95m + 1.0m + 1.6m + 0.8m + 2.75m + 0.7m +
2.5m + 1.35m + 3.5m + 2.1m + 2.75m + 0.8m + 3.3m + 2.05m = 34.05m x 3.28 =
111.684pl +10% = 122.85pl
2.0m + 2.25m + 2.75m + 2.05m + 1.6m + 1.5m + 2.75m + 2.5m + 3.5m + 2.1m =
23m x 3.28 = 75.44pl + 10% = 82.984pl
2.65m + 0.8m + 3.3m + 2.05m + 2.65m + 1.25m + 3.55m + 3.05m + 4.75m + 2.1m +
5.35m + 2.3m = 33.8m x 3.28 = 110.864 pl + 10% = 121.95 pl
0.8m + 2.05m x (2) + 4.65m + 3.2m + 1.25m x (2) + 3.1m + 2.05m + 2.0m + 2.35m x
(3) = 29.45m x 3.28 = 96.60pl + 10% = 106.26pl
2.65m + 3.3m + 4.65m + 2.6m + 3.2m + 3.55m + 4.8m + 5.3m + 2.0m + 3.9m =
35.95m x 3.28 = 117.92pl + 10% = 129.712pl
Total de pl de conductores # 12
1.30m + 3.20m + 0.20m + 1.40m + 4.10m + 3.10m + 1.20m + 1.40m = 15.9m x 3.28
= 52.152pl + 10% = 57.37pl
1.30m + 3.20m + 0.20m + 1.40m + 4.10m + 3.10m + 1.20m + 1.40m = 15.9m x 3.28
= 52.152pl + 10% = 57.37pl
1.30m + 3.20m + 0.20m + 1.40m + 4.10m + 3.10m + 1.20m + 1.40m = 15.9m x 3.28
= 52.152pl + 10% = 57.37pl
Total de pl de conductor # 10
Total de pl de conductor # 8
4.0m + 3.0m + 5.45m + 4.10m + 9.0m = 25.55m x 3.28 = 83.804pl + 10% = 92.18pl
0.70m + 0.90m + 1.45m + 0.55m + 1.70m + 1.80m + 0.70m x (2) + 1.90m = 10.4m x
3.28 = 34.112pl + 10% = 37.52pl
3.10m + 1.40m + 2.65m + 1.10m + 2.70m + 1.0m + 2.80m + 1.90m + 3.40m + 1.5m
+ 2.40m + 1.80m + 4.70m + 2.40m = 32.85m x 3.28 = 107.748 pl + 10% = 118.52 pl
4.70m + 1.40m x (2) + 1.15m + 1.0m + 1.90m + 1.50m + 1.75m + 2.40m = 17.2m x
3.28 = 56.42pl + 10% = 62.062pl
3.15m + 4.65m + 2.60m + 2.7m + 2.85m + 3.40m + 4.7m + 2.5m = 26.55m x 3.28 =
87.084pl + 10% = 95.79pl
Total de pl de conductores # 12
0.75m + 0.60m + 0.40m + 0.85m + 1.80m + 1.40m + 0.7m + 0.55m + 2.70m + 1.7m
+ 2.50m + 1.80m + 2.5m + 0.8m + 1.9m + 3.20m + 1.40m + 4.60m + 2.60m + 1.20m
+ 2.70m + 0.95m + 2.85m + 1.90m + 3.40m + 1.50m + 2.45m + 1.80m + 4.80m +
2.4m = 58.7m x 3.28 = 192.54pl/19’ = 10.13 = 11 unidad
1.50m + 1.40m + 1.0m + 1.20m + 2.45m + 2.30m + 2.0m + 4.70m = 16.55m x 3.28 =
54.284pl + 10% = 59.71pl
1.50m + 1.40m + 1.0m + 1.20m + 2.45m + 2.30m + 2.0m + 4.70m = 16.55m x 3.28 =
54.284pl + 10% = 59.71pl
1.50m + 1.40m + 1.0m + 1.20m + 2.45m + 2.30m + 2.0m + 4.70m = 16.55m x 3.28 =
54.284pl + 10% = 59.71pl
Circuito # 11 (T.C) conductor # 10
4.50m + 0.5m + 3.80m + 2.90m + 3.75m + 1.90m + 6.20m + 3.0m = 26.55m x 3.28 =
87.084pl + 10% = 95.79pl
4.50m + 0.5m + 3.80m + 2.90m + 3.75m + 1.90m + 6.20m + 3.0m = 26.55m x 3.28 =
87.084pl + 10% = 95.79pl
4.50m + 0.5m + 3.80m + 2.90m + 3.75m + 1.90m + 6.20m + 3.0m = 26.55m x 3.28 =
87.084pl + 10% = 95.79pl
2.85m + 0.20m + 3.50m + 3.45m + 4.30m + 4.30m + 3.0m + 1.5m = 23.1m x 3.28 =
75.77pl + 10% = 83.35pl
2.85m + 0.20m + 3.50m + 3.45m + 4.30m + 4.30m + 3.0m + 1.5m = 23.1m x 3.28 =
75.77pl + 10% = 83.35pl
2.85m + 0.20m + 3.50m + 3.45m + 4.30m + 4.30m + 3.0m + 1.5m = 23.1m x 3.28 =
75.77pl + 10% = 83.35pl
T.C especial 240v (A/A1) conductor # 8
Total de pl de conductor # 10
59.71 (3) pl + 95.79 (3) pl + 13.35 (3) pl + 83.35 (3) = 756.6pl
Total de pl de conductor # 8
½” = 40 unidad
Presupuesto de materiales
Instalaciones Eléctricas
3er Parcial
Para:
José Sepúlvedra
Presentado Por:
22/07/2006