CÁLCULOS DE POTENCIA DE APARATOS ELECTRICOS 1er NIVEL

Circuito #1 (14Luminaria incandescente a 120 v)

a) 6 luminaria incandescente (circuito C1)

PW = 6 x 100w = 600w
PKW = 600w/1000 = 0.6 kw
PKVA = 0.6 kw/1 = 0.6 kva
I = P/V= 600w/120v = 5 amp.

b) 8 luminaria incandescente (C2)

PW = 8 x 100w = 800w
PKW = 800w/1000 = 0.8 kw
PKVA = 0.8kw/1 = 0.8 kva
I = P/V = 800w/120v = 6.67 amp.

(11 T.C de uso general a 120v)

a) 5 T.C a 120v (circuito C4)

PW = 5 x 150w = 750w
PKW = 750w/1000 = 0.75 kw
PKVA = 0.75kw/0.8 = 1.5 kva
I = 750w/120v = 6.25 amp.

b) 6 T.C a 120v (circ. # 19)

PW = 6 x 150w = 900w
PKW = 900w/1000 = 0.9 kw
PKVA = 0.9kw/0.8 = 1.13 kva
I = 900w/120v = 7.5 amp.
Circuito # 6 (1 microondas (1500w) a 120v)

PW = 1500w
PKW = 1500w/1000 = 1.5 kw
PKVA = 1.5kw/1 = 1.5 kva
I = 1500w/120v = 12.5 amp.

Circuito # 9,11 (1 A/A, 1 de (1000w)

a) A/A1 (1000w) a 120v (circuito 6)

PW = 1000w
PKW = 1000w/1000 = 1 kw
PKVA = 1kw/0.8 = 1.25 kva
I = 1000w/120v = 8.33 Amp.

Circuito # 8 (1 nevera de 600w a 120v)

PW = 600w
PKW = 600w/1000 = 0.6 kw
PKVA = 0.6kw/0.8 = 0.75 kva
I = P/V = 600w/120v = 5 amp.

Circuito # 18,20 (1 bomba de H2O de 1000w)

PW = 1000w
PKW = 1000w/1000w = 1.0 kw
PKVA = 1.0kw/0.8 = 1.3 kva
I = P/V = 1000w/240v = 4.167 amp.

Circuito # 6 (1 tostadora de 1500w a 120v)

PW = 1500w
PKW = 1500w/1000 = 1.5 kw
PKVA = 1.5kw/1 = 1.5 kva
I = P/V = 1500w/120v = 12.5 amp.

Circuito # 7 (1 lavadora a 120v)

PW = 650w
PKW = 650w/1000 = 0.65 kw
PKVA = 0.65kw/0.8 = 0.8125 kva
I = P/V = 650w/120v = 5.42 amp.

Circuito # 9,11 (2 T.C a 240v) (especial)

PW = 2 x 150w = 300w
PKW = 300w/1000 = 0.3 kw
PKVA = 0.3kw/0.8 = 0.375 kva
I = P/V = 300w/240 = 1.25 amp.

Circuito # 24 (Timbre (75 W) a 120 v)

PW = 75w
PKW = 75w/1000 = 0.075 KW
PKVA = 0.075kw/0.8 = 0.094 kva
I = P/V = 75/120V = 0.62 amp

Circuito # 6 (T.C sobre meseta a 120 v)

PW = 3000w
PKW = 3000w/1000 = 3 kw
PKVA = 3w/0.8 = 3.75 kva
I = 3000w/120v = 25 amp.
TOTAL DE POTENCIA Y AMPERAJE

POTENCIA EN WATTS = 12,675 watts

POTENCIA EN KWATTS = 12.675 kwatts

POTENCIA EN KVA = 15.3615 kva

AMPERAJE TOTAL = 100.207 amp.

CÁLCULOS DE POTENCIA DE APARATOS ELECTRICOS 2do NIVEL

Circuito C3 (8Luminaria incandescente a 120 v)

c) 8 luminaria incandescente (circuito # 3)

PW = 8 x 100w = 800w
PKW = 800w/1000 = 0.8 kw
PKVA = 0.8 kw/1 = 0.8 kva
I = P/V= 800w/120v = 6.67 amp.

Circuito #10(15T.C de uso general a 120v)

c) 7 T.C a 120v (circuito #10).

PW = 7 x 150w = 1050w
PKW = 1050w/1000 = 1.05 kw
PKVA = 1.05kw/0.8 = 1.3125 kva
I = 1050w/120v = 8.8 amp.
d) 8 T.C a 120v (circ. # 8)

PW = 8 x 150w = 1200w
PKW = 1200w/1000 = 1.2 kw
PKVA = 1.2kw/0.8 = 1.5 kva
I = 1200w/120v = 10 amp.

Circuito # 13,15 y 14,16 (2 A/A, 1 de (1000w) y otro (1200w) a 120v y 240v

b) A/A1 (1000w) a 120v (circuito 13,15)

PW = 1000w
PKW = 1000w/1000 = 1 kw
PKVA = 1kw/0.8 = 1.25 kva
I = 1000w/120v = 8.33 Amp.

c) A/A2 (1200w) a 240v (circ. 14,16)

PW = 1200w
PKW = 1200w/1000 = 1.2 kw
PKVA = 1.2kw/0.8 = 1.5 kva
I = P/V = 1200w/240v = 5 amp.

Circuito #17,19 (2 T.C a 240v) (especial)

PW = 2 x 150w = 300w
PKW = 300w/1000 = 0.3 kw
PKVA = 0.3kw/0.8 = 0.375 kva
I = P/V = 300w/240 = 1.25 amp.

Circuito 18,20 (2 T.C a 240v) (especial)

PW = 2 x 150w = 300w
PKW = 300w/1000 = 0.3 kw
PKVA = 0.3kw/0.8 = 0.375 kva
I = P/V = 300w/240 = 1.25 amp.

d) A/A2 (1900w) a 240v (circ. 17,19)


PW = 1900w
PKW = 1900w/1000 = 1.9 kw
PKVA = 1.9kw/0.8 = 2.38 kva
I = P/V = 1900w/240v = 7.92 amp.

Calentado circ. 21,23 H2O (1 CH2O C 21,23)(1200) a 240

PW = 2100w
PKW = 2100w/1000 = 2.1 kw
PKVA = 2.1kw/1 = 2.1 kva
I = P/V = 2100w/240v = 8.75 amp.

TOTAL DE POTENCIA Y AMPERAJE

POTENCIA EN WATTS = 9,850 watts

POTENCIA EN KWATTS = 9.850 kwatts

POTENCIA EN KVA = 11.5825 kva

AMPERAJE TOTAL = 58.22 amp.

Circuito # 14 Cálculos de alambres luminaria incandescente 1er nivel

Fase (alambre rojo) conductor # 12

1.7m + 2.0m + 2.70m + 0.5m + 1.95m + 1.0m + 1.6m + 0.8m + 2.75m + 0.7m +
2.5m + 1.35m + 3.5m + 2.1m + 2.75m + 0.8m + 3.3m + 2.05m = 34.05m x 3.28 =
111.684pl +10% = 122.85pl

Retorno (alambre amarillo) conductor # 12


1.7m x (2) + 2.25m + 0.6m + 0.9m + 0.8m x (2) + 1.5m + 0.75m + 1.4m + 2.1m =
14.5m x 3.28 = 47.56pl + 10% = 52.32pl

Neutro (alambre blanco) conductor # 12

2.0m + 2.25m + 2.75m + 2.05m + 1.6m + 1.5m + 2.75m + 2.5m + 3.5m + 2.1m =
23m x 3.28 = 75.44pl + 10% = 82.984pl

Circuito # 10 (luminaria) conductor # 12

Fase (alambre rojo) conductor # 12

2.65m + 0.8m + 3.3m + 2.05m + 2.65m + 1.25m + 3.55m + 3.05m + 4.75m + 2.1m +
5.35m + 2.3m = 33.8m x 3.28 = 110.864 pl + 10% = 121.95 pl

Retorno (alambre amarillo) conductor # 12

0.8m + 2.05m x (2) + 4.65m + 3.2m + 1.25m x (2) + 3.1m + 2.05m + 2.0m + 2.35m x
(3) = 29.45m x 3.28 = 96.60pl + 10% = 106.26pl

Neutro (alambre blanco) conductor # 12

2.65m + 3.3m + 4.65m + 2.6m + 3.2m + 3.55m + 4.8m + 5.3m + 2.0m + 3.9m =
35.95m x 3.28 = 117.92pl + 10% = 129.712pl

Total de pl de conductores # 12

122.85pl + 52.32pl + 82.984pl + 121.95pl + 106.26pl + 129.712pl = 616.08pl

Cantidad de tubería de ½” de luminaria (conductor # 12)


2.0m + 1.7m + 2.25m + 2.75m + 0.7m + 2.05m + 0.9m + 1.55m + 0.85m + 1.5m +
2.75m + 0.75m + 2.5m + 1.4m + 3.5m + 2.1m + 2.6m + 0.85m + 3.3m + 2.05m +
4.7m + 2.65m + 1.25m + 3.2m + 3.55m + 3.1m + 4.75m + 2.1m + 5.15m + 2.45m +
2.3m + 3.95m = 77.2m x 3.28 = 253.216pl/19’ = 13.33 = 14 unidad

Circuito # 17 (cantidad de conductores de T.C a 120v) conductor # 10

Fase (alambre rojo) conductor # 10

1.30m + 3.20m + 0.20m + 1.40m + 4.10m + 3.10m + 1.20m + 1.40m = 15.9m x 3.28
= 52.152pl + 10% = 57.37pl

Neutro (alambre blanco) conductor # 10

1.30m + 3.20m + 0.20m + 1.40m + 4.10m + 3.10m + 1.20m + 1.40m = 15.9m x 3.28
= 52.152pl + 10% = 57.37pl

Tierra (verde) conductor # 10

1.30m + 3.20m + 0.20m + 1.40m + 4.10m + 3.10m + 1.20m + 1.40m = 15.9m x 3.28
= 52.152pl + 10% = 57.37pl

Circuito # 19 (T.C) conductor # 10

Fase (alambre rojo) conductor # 10


3.80m + 1.40m + 3.90m + 3.90m + 1.90m + 4.80m + 3.70m + 4.40m + 1.20m +
0.20m + 2.30m + 3.05m + 0.75m + 3.0m + 3.30m = 41.6m x 3.28 = 136.45pl + 10%
= 150.095pl

Neutro (alambre blanco) conductor # 10

3.80m + 1.40m + 3.90m + 3.90m + 1.90m + 4.80m + 3.70m + 4.40m + 1.20m +


0.20m + 2.30m + 3.05m + 0.75m + 3.0m + 3.30m = 41.6m x 3.28 = 136.45pl + 10%
= 150.095pl

Tierra (alambre verde) conductor # 10

3.80m + 1.40m + 3.90m + 3.90m + 1.90m + 4.80m + 3.70m + 4.40m + 1.20m +


0.20m + 2.30m + 3.05m + 0.75m + 3.0m + 3.30m = 41.6m x 3.28 = 136.45pl + 10%
= 150.095pl

Circuito # 2 (T.C) conductor # 10

Fase (alambre rojo) conductor #10

0.40m = 0.40m x 3.28 = 1.312pl + 10% = 1.44pl

Neutro (alambre blanco) conductor # 10

0.40m = 0.40m x 3.28 = 1.312pl + 10% = 1.44pl

Tierra (alambre verde) conductor # 10

0.40m = 0.40m x 3.28 = 1.312pl + 10% = 1.44pl

T.C especial 240v (A/A1) conductor # 8


7.0m = 7.0m x 3.28 = 22.96pl + 10% = 25.26pl

T.C especial 240v (A/A2) conductor # 8

7.80m = 7.80m x 3.28 = 25.584pl + 10% = 28.14pl

Total de pl de conductor # 10

57.37 (3) pl + 150.095 (3) pl + 1.44 (3) pl = 626.715pl

Total de pl de conductor # 8

25.26 pl + 28.14 pl = 53.4pl

Cantidad de tubería de T.C (conductor # 10)

Tubería de ½” = 626.715pl/19’ = 32.98 = 33 unidad

Cantidad de tubería de T.C (conductor # 8)

Tubería de ¾” = 53.4’/20’ = 2.67 = 3 unidad

Cantidad de conductores de timbre (conductor # 10)

7.80m = 7.80m x 3.28 = 25.584pl (2) = 51.17pl + 10 % = 56.29pl

Cantidad de tubo de timbre (conductor # 10)


Tubería de ½” = 56.29pl/19’ = 2.96 = 3 unidad

Cantidad de conductores de teléfonos (conductor # 8)

9.50m + 1.50m + 11.0m = 22m x 3.28 = 72.16pl + 10% = 79.38pl

Cantidad de tubo de teléfono (conductor # 8)

Tubería de ¾” = 79.38’/20’ = 3.97 = 4 unidad

Cantidad de conductores de antena y cable (conductor # 10)

4.0m + 3.0m + 5.45m + 4.10m + 9.0m = 25.55m x 3.28 = 83.804pl + 10% = 92.18pl

Cantidad de tubo de antena y cable (conductor # 10)

Tubería de ½” = 92.18’/19’ = 4.85 = 5 unidad

Cantidad total de tubería:

½” = 14 unidad + 33 unidad + 3 unidad + 5 unidad = 55 unidad

¾” = 4 unidad + 3 unidad = 7 unidad

Circuito # 2 Cálculos de alambres luminaria incandescente 2do nivel

Fase (alambre rojo) conductor # 12


0.60m + 0.80m + 2.40m + 0.9m + 1.80m + 1.50m + 3.70m + 0.6m + 2.70m + 1.7m +
2.5m + 0.70m + 2.5m + 1.9m = 24.3m x 3.28 = 79.704pl + 10% = 87.67pl

Retorno (alambre amarillo) conductor # 12

0.70m + 0.90m + 1.45m + 0.55m + 1.70m + 1.80m + 0.70m x (2) + 1.90m = 10.4m x
3.28 = 34.112pl + 10% = 37.52pl

Neutro (alambre blanco) conductor # 12

0.60m + 2.40m + 1.80m + 3.70m + 2.80m + 2.50m + 1.80m + 2.55m = 18.15m x


3.28 = 59.532pl + 10% = 65.48pl

Circuito # 4 (luminaria) conductor # 12

Fase (alambre rojo) conductor # 12

3.10m + 1.40m + 2.65m + 1.10m + 2.70m + 1.0m + 2.80m + 1.90m + 3.40m + 1.5m
+ 2.40m + 1.80m + 4.70m + 2.40m = 32.85m x 3.28 = 107.748 pl + 10% = 118.52 pl

Retorno (alambre amarillo) conductor # 12

4.70m + 1.40m x (2) + 1.15m + 1.0m + 1.90m + 1.50m + 1.75m + 2.40m = 17.2m x
3.28 = 56.42pl + 10% = 62.062pl

Neutro (alambre blanco) conductor # 12

3.15m + 4.65m + 2.60m + 2.7m + 2.85m + 3.40m + 4.7m + 2.5m = 26.55m x 3.28 =
87.084pl + 10% = 95.79pl
Total de pl de conductores # 12

87.67pl + 37.52pl + 65.48pl + 118.52pl + 62.062pl + 95.79pl = 467.042pl

Cantidad de tubería de ½” de luminaria (conductor # 12)

0.75m + 0.60m + 0.40m + 0.85m + 1.80m + 1.40m + 0.7m + 0.55m + 2.70m + 1.7m
+ 2.50m + 1.80m + 2.5m + 0.8m + 1.9m + 3.20m + 1.40m + 4.60m + 2.60m + 1.20m
+ 2.70m + 0.95m + 2.85m + 1.90m + 3.40m + 1.50m + 2.45m + 1.80m + 4.80m +
2.4m = 58.7m x 3.28 = 192.54pl/19’ = 10.13 = 11 unidad

Circuito # 9(cantidad de conductores de T.C a 120v) conductor # 10

Fase (alambre rojo) conductor # 10

1.50m + 1.40m + 1.0m + 1.20m + 2.45m + 2.30m + 2.0m + 4.70m = 16.55m x 3.28 =
54.284pl + 10% = 59.71pl

Neutro (alambre blanco) conductor # 10

1.50m + 1.40m + 1.0m + 1.20m + 2.45m + 2.30m + 2.0m + 4.70m = 16.55m x 3.28 =
54.284pl + 10% = 59.71pl

Tierra (verde) conductor # 10

1.50m + 1.40m + 1.0m + 1.20m + 2.45m + 2.30m + 2.0m + 4.70m = 16.55m x 3.28 =
54.284pl + 10% = 59.71pl
Circuito # 11 (T.C) conductor # 10

Fase (alambre rojo) conductor # 10

4.50m + 0.5m + 3.80m + 2.90m + 3.75m + 1.90m + 6.20m + 3.0m = 26.55m x 3.28 =
87.084pl + 10% = 95.79pl

Neutro (alambre blanco) conductor # 10

4.50m + 0.5m + 3.80m + 2.90m + 3.75m + 1.90m + 6.20m + 3.0m = 26.55m x 3.28 =
87.084pl + 10% = 95.79pl

Tierra (alambre verde) conductor # 10

4.50m + 0.5m + 3.80m + 2.90m + 3.75m + 1.90m + 6.20m + 3.0m = 26.55m x 3.28 =
87.084pl + 10% = 95.79pl

Circuito # 12 (T.C) conductor # 10

Fase (alambre rojo) conductor #10

3.70m = 3.70m x 3.28 = 12.136pl + 10% = 13.35pl

Neutro (alambre blanco) conductor # 10


3.70m = 3.70m x 3.28 = 12.136pl + 10% = 13.35pl

Tierra (alambre verde) conductor # 10

3.70m = 3.70m x 3.28 = 12.136pl + 10% = 13.35pl

Circuito # 6 (T.C) conductor # 10

Fase (alambre rojo) conductor #10

2.85m + 0.20m + 3.50m + 3.45m + 4.30m + 4.30m + 3.0m + 1.5m = 23.1m x 3.28 =
75.77pl + 10% = 83.35pl

Neutro (alambre blanco) conductor # 10

2.85m + 0.20m + 3.50m + 3.45m + 4.30m + 4.30m + 3.0m + 1.5m = 23.1m x 3.28 =
75.77pl + 10% = 83.35pl

Tierra (alambre verde) conductor # 10

2.85m + 0.20m + 3.50m + 3.45m + 4.30m + 4.30m + 3.0m + 1.5m = 23.1m x 3.28 =
75.77pl + 10% = 83.35pl
T.C especial 240v (A/A1) conductor # 8

9.0m = 9.0m x 3.28 = 29.52pl + 10% = 32.472pl

T.C especial 240v (A/A2) conductor # 8

5.20m = 5.20m x 3.28 = 17.056pl + 10% = 18.76pl

Total de pl de conductor # 10
59.71 (3) pl + 95.79 (3) pl + 13.35 (3) pl + 83.35 (3) = 756.6pl

Total de pl de conductor # 8

32.472 pl + 18.76 pl = 51.232pl

Cantidad de tubería de T.C (conductor # 10)

Tubería de ½” = 756.6pl/19’ = 39.82 = 40 unidad

Cantidad de tubería de T.C (conductor # 8)

Tubería de ¾” = 51.232’/20’ = 2.56 = 3 unidad

Cantidad de conductores de teléfonos (conductor # 8)

5.0m + 11.80m + 6.90m = 23.7m x 3.28 = 77.74pl + 10% = 85.514pl

Cantidad de tubo de teléfono (conductor # 8)

Tubería de ¾” = 85.514’/20’ = 4.27 = 5 unidad

Cantidad de conductores de antena y cable (conductor # 8)

5.10m + 13.25m + 5.30m = 23.65m x 3.28 = 77.572pl + 10% = 85.33pl

Cantidad de tubo de antena y cable (conductor # 8)


Tubería de ¾” = 85.33’/19’ = 4.49 = 5 unidad

Cantidad total de tubería:

½” = 40 unidad

¾” = 3 unidad + 5 unidad + 5 unidad = 13 unidad

Presupuesto de materiales

Cant. Artículo Precio RD$ Total


7 unid. Breaker 30/2 Amp. $150.00 $1,050
11 unid. Breaker 20 Amp. $300.00 $3,300
25 unid. Salida Tomacorriente 120 V $10.50 $262.
2unid. Cut-out 100 amp $1,930.70 $3,861.4
1unid. Fusible 10 amp $58.63 $58.63
1unid. Fusible de 5.20 amp $22.36 $22.36
2unid. Pararrayo 9 kv $1,463.30 $2,926
1unid. Salida de Timbre $85.25 $85.25
1unid. Salida de Pulsador de Timbre $46.79 $46.79
2unid. Caja de breaker $1,459.89 $2,919.78
6 unid. Salida de Teléfono $38.45 $230.7
6 unid. Salida de Telecable $47.73 $286.38
1 unid. Inst. de Transformador $11,000 $11,000
1unid. Porta Contador $500.00 $500
1unid. Inst. Panel de Distribución $600.00 $600
1unid. Conexión Ede- Norte $7,500 $7500
47 unid. Tubo PVC semi-presión ½” $133.0 $6,251
6 unid. Tubo PVC semi-presión ¾” $152.0 $912
¼ Gls Cemento PVC $75.0 $18.75
612.86p Alambre # 12 $19.0 $11,644.34
621.05p Alambre # 10 $13.95 $8,663.65
98.70p Alambre # 8 $8.50 $838.95
150 pl Cable de aluminio AAAC 2/0 $4.70 $705
1unid. Transformador 25 kva $15,200 $15,200
2 unid. Viento completo $1,403.36 $2,806.72
1unid. Conector varilla Aterrizaje # 4 $36.45 $36.45
2 unid Palometa cabeza de poste $150.0 $300
2 unid Aislador tipo pin $130.0 $260
4 unid Aislador de suspensión $165.36 $661.44
1unid. Varilla de aterrizaje 5/8” x 8 $243.36 $243.36
31 unid Tuerca guardacabo 5/8” x 14 $63.0 $1953
27 unid Tapa plástica p/T.C $3.25 $87.75
2 unid Tornillo guardacabo 5/8” x 14 $77.0 $154
17 unid Caja de registro octagonal ½” $26.0 $442
3 unid Caja de registro 8” x 8” x 4’ $53.95 $161.85
25 unid Caja para T.C 2 x 4” ½” $24.0 $600
2 unid Caja para T.C 2 x 4” ¾” $36.0 $72
13 unid Caja de interruptor 2 x 4 ½” $24.0 $312
4 unid Interruptor sencillo $36.0 $144
2 unid Interruptor sencillo (3W) $75.85 $151.7
4 unid Interruptor doble $70.0 $280
1 unid Interruptor triple $95.0 $95
17 unid Roseta de porcelana $33.90 $576.3
17 unid Bombillo incandescente 100w $12.0 $204
1unid. Percha completa $280.0 $280
3 unid Tornillo 5/8” x 16’percha $162.0 $486
3 unid Arandela 2 x 4 para percha $4.25 $12.75
1unid. Porta contador acero (150 amp.) $1,200 $1,200
1unid. Poste 35’ (Transp., instalación) $6,850.0 $6,850
2 unid Tornillo de ojo 5/8 x 12 $65.0 $130
4 unid Tornillo 5/8 x 14 $75.0 $300
1unid. Cleivi completo $150.0 $150
2 unid Salida de T.C de 240v $16.30 0
1unid. Condulet EMT 1 ½” $148.58 $185
70 unid Curva PVC ½” $2.65 $1,6065
4 unid Curva PVC 2” $27.560 $172
13 unid Curva PVC ¾” $6.13 $480.35
2unid Tubo Conduit Galv. IMC 1 ½ x10 $1,384.52 s2,769,04
Total $95,526.18

Costo de salida y mano de obra


HONORARIOS

Costo de materiales + mano de obra =


RD$95,526.18 + RD$= 33,876.8 = $129,402.98 (costo total de la obra)
CANT. MANO DE OBRA PRECIO P/UNIDAD TOTAL
2 unid Salida Interruptor Sencillo y (3W) RD$400.00 RD$800
4 unid Salida Interruptor Doble RD$350.00 RD$1,400
1 unid Salida Interruptor Triple RD$300.00 RD$300
25 unid Salida de T.C 120v RD$200.00 RD$5,000
17 unid Salida de Rosetas RD$300.00 RD$5,100
2 unid Salida de Toma Corriente 240v RD$350.00 RD$700
1 unid Salida Panel de Distribución RD$1,500.00 RD$1,500
2 unid Salida Acondicionador de Aire RD$600.00 RD$1,200
1 unid Salida Calentador de Agua RD$600.00 RD$600
1 unid Salida Bomba de Agua RD$600.00 RD$600
191.34m2 Diseño Plano Eléctrico RD$20.00 RD$3,826.8
1 unid Instalación Porta Contador RD$1,500.00 RD$1,500
1 unid Interconexión Transformador RD$4,000.00 RD$4,000
8 unid Breaker Doble RD$350.00 RD$2,800
13 unid Breaker Sencillo RD$150.00 RD$1,950
1 unid Salida Timbre RD$300.00 RD$300
1 unid Transporte de Grúa Para Poste RD$3,000.00 RD$3,000
2 unid Hoyos de 6 Pies Para Poste RD$350.00 RD$700
2 unid Hoyos Para Viento RD$300.00 RD$600
2 unid Parada de Poste RD$500.00 RD$1000
TOTAL RD$33,876.8

DESCRIPCION COSTO COBRO % TOTAL


TRANSP. Y VIATICO RD$129,402.98 5% RD$6,470.15
INGENIERO RD$129,402.98 12% RD$15,528.36
IMPREVISTO RD$129,402.98 5% RD$6,470.15
SUPERVISION RD$129,402.98 11% RD$14,234.33

Universidad Tecnológica De Santiago


“UTESA”

Instalaciones Eléctricas

3er Parcial

Para:

José Sepúlvedra

Presentado Por:

Jhonatan Antonio Pérez


1-04-3487

22/07/2006

Santiago De Los Caballeros


R.D.

You might also like